Shopping Cart

No products in the cart.

MN Mechanical FuelGas PlumbingCode 2000

$30.33

Minnesota State Mechanical, Fuel Gas and Plumbing Code

Published By Publication Date Number of Pages
MN 2000 372
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Minnesota State Mechanical, Fuel Gas and Plumbing Code is based on the 2000 IMC®, 2000 IFGC® and the Minnesota Plumbing Code

PDF Catalog

PDF Pages PDF Title
1 COVER
2 COPYRIGHT
3 TABLE OF CONTENTS – MINNESOTA RULES, CHAPTER 1300
5 MINNESOTA RULES, CHAPTER 1300
1300.0010 – ADMINISTRATION
1300.0020 – TITLE
1300.0030 – PURPOSE AND APPLICATION
1300.0040 – SCOPE
1300.0050 – CHAPTERS OF MINNESOTA STATE BUILDING CODE
6 1300.0060 – OPTIONAL ADMINISTRATION
1300.0070 – DEFINITIONS
7 1300.0080 – CODE ADOPTION AND AMENDMENTS
1300.0090 – DEPARTMENT OF BUILDING SAFETY
1300.0110 – DUTIES AND POWERS OF BUILDING OFFICIAL
9 1300.0120 – PERMITS
10 1300.0130 – CONSTRUCTION DOCUMENTS
11 1300.0140 – VIOLATIONS
1300.0150 – VIOLATIONS, PENALTY
12 1300.0160 – FEES
13 1300.0170 – STOP WORK ORDER
1300.0180 – UNSAFE BUILDINGS OR STRUCTURES
1300.0190 – TEMPORARY STRUCTURES AND USES
1300.0210 – INSPECTIONS
14 1300.0220 – CERTIFICATE OF OCCUPANCY
15 1300.0230 – BOARD OF APPEALS
1300.0240 – DISCLAIMER CAUSE
1300.0250 – SEVERABILITY
17 TABLE OF CONTENTS – MINNESOTA MECHANICAL CODE
21 MINNESOTA RULES, CHAPTER 1346 – MINNESOTA MECHANICAL CODE
1346.0050 – INCORPORATION BY REFERENCE
1346.0060 – REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES
23 CHAPTER 1 – ADMINISTRATION
SECTION 101 – SCOPE
SECTION 102 – EXISTING INSTALLATIONS
SECTION 103 – MAINTENANCE
SECTION 104 – ADDITIONS, ALTERATIONS, RENOVATIONS, OR REPAIRS
SECTION 105 – WORK EXEMPT FROM PERMIT
SECTION 106 – REQUIRED INSPECTIONS
24 SECTION 107 – TESTING
SECTION 108 – AUTHORITY TO CONDEMN MECHANICAL SYSTEMS
SECTION 109 – AUTHORITY TO ORDER DISCONNECTION OF ENERGY SOURCES
SECTION 110 – CONNECTION AFTER ORDER TO DISCONNECT
25 CHAPTER 2 – DEFINITIONS
SECTION 201 – GENERAL
SECTION 202 – GENERAL DEFINITIONS
35 CHAPTER 3 – GENERAL REGULATIONS
SECTION 301 – GENERAL
36 SECTION 302 – PROTECTION OF STRUCTURE
SECTION 303 – EQUIPMENT AND APPLIANCE LOCATION
37 SECTION 304 – INSTALLATION
38 SECTION 305 – PIPING SUPPORT
TABLE 305.4 – PIPING SUPPORT SPACINGa
SECTION 306 – ACCESS AND SERVICE SPACE
40 SECTION 307 – CONDENSATE DISPOSAL
SECTION 308 – CLEARANCE REDUCTION
41 TABLE 308.6 – CLEARANCE REDUCTION METHODS
[B] SECTION 309 – TEMPERATURE CONTROL
42 [F] SECTION 310 – EXPLOSION CONTROL
[F] SECTION 311 – SMOKE AND HEAT VENTS
SECTION 312 – HEATING AND COOLING LOAD CALCULATIONS
43 CHAPTER 4 – VENTILATION
SECTION 401 – GENERAL
TABLE 401.6 – OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
[B] SECTION 402 – NATURAL VENTILATION
44 SECTION 403 – MECHANICAL VENTILATION
(Equation 4-1)
45 SECTION 404 – GARAGES
SECTION 405 – SYSTEMS CONTROL
SECTION 406 – VENTILATION OF UNINHABITED SPACES
47 CHAPTER 5 – EXHAUST SYSTEMS
SECTION 501 – GENERAL
48 TABLE 501.4.1 – PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN DWELLINGS
49 TABLE 501.4.2 – MAKEUP AIR OPENING SIZING TABLE FOR NEW AND EXISTING DWELLINGS
50 TABLE 501.4.3(1) – PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN EXISTING DWELLINGS
51 TABLE 501.4.3(2) – PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN DWELLINGS
52 TABLE 501.4.3(3) – PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST IN EXISTING DWELLINGS
53 SECTION 502 – REQUIRED SYSTEMS
59 SECTION 503 – MOTORS AND FANS
SECTION 504 – CLOTHES DRYER EXHAUST
60 SECTION 505 – DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION 506 – COMMERCIAL KITCHEN GREASE DUCTS AND EXHAUST EQUIPMENT
61 SECTION 507 – COMMERCIAL KITCHEN HOODS
62 SECTION 508 – COMMERCIAL KITCHEN MAKEUP AIR
63 SECTION 509 – FIRE SUPRESSION SYSTEMS
SECTION 510 – HAZARDOUS EXHAUST SYSTEMS
64 TABLE 510.8 – MINIMUM DUCT THICKNESS
TABLE 510.8.2 – CLEARANCE TO COMBUSTIBLES
SECTION 511 – DUST, STOCK AND REFUSE CONVEYING SYSTEMS
65 TABLE 511.2 – CONSTRUCTION, CLEARANCE AND TERMINATION REQUIRED FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 – SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 – SMOKE CONTROL SYSTEMS
67 (Equation 5-2)
(Equation 5-3)
(Equation 5-4)
68 (Equation 5-5)
(Equation 5-6)
(Equation 5-7)
(Equation 5-8)
(Equation 5-9)
69 (Equation 5-10)
71 CHAPTER 6 – DUCT SYSTEMS
SECTION 601 – GENERAL
SECTION 602 – PLENUMS
72 SECTION 603 – DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.3 – DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITS
74 SECTION 604 – INSULATION
75 SECTION 605 – AIR FILTERS
SECTION 606 – SMOKE DETECTION SYSTEMS CONTROL
[B] SECTION 607 – DUCTS AND AIR TRANSFER OPENINGS
76 TABLE 607.3.1 – FIRE DAMPER RATING
79 TABLE 1-10 INTERMEDIATE REINFORCEMENT
80 TABLE 4-1 RECTANGULAR DUCT HANGERS MINIMUM SIZE
81 TABLE 4-2 MINIMUM HANGER SIZES FOR ROUND DUCT
82 TABLE 3-2A ROUND DUCT GAGE UNREINFORCED POSITIVE PRESSURE
83 TABLE 3-2B ROUND DUCT GAGE NEGATIVE PRESSURE
84 TABLE 3-4 FLAT OVAL DUCT CONSTRUCTION
85 TABLE 1-5 E4 – TRANSVERSE JOINT REINFORCEMENT
86 TABLE 1-5 E5 – TRANSVERSE JOINT RENIFORCEMENT
87 TABLE 1-4 E4 – TRANSVERSE JOINT REINFORCEMENT
88 TABLE 1-4 E5 – TRANSVERSE JOINT RENIFORCEMENT
89 CHAPTER 7 – COMBUSTION AIR
SECTION 701 – GENERAL
SECTION 702 – INSIDE AIR
SECTION 703 – OUTDOOR AIR
90 SECTION 704 – COMINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 1)
SECTION 705 – COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2)
SECTION 706 – FORCED COMBUSTION AIR SUPPLY
SECTION 707 – DIRECT CONNECTION
SECTION 708 – COMBUSTION AIR DUCTS
91 SECTION 709 – OPENING OBSTRUCTIONS
SECTION 710 – OPENING LOCATION AND PROTECTION
93 CHAPTER 8 – CHIMNEY S AND VENTS
SECTION 801 – GENERAL
94 SECTION 802 – VENTS
TABLE 802.2 – VENT APPLICATIONS
95 SECTION 803 – CONNECTORS
TABLE 803.9(1) – MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) – MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
96 TABLE 803.10.4 – CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCESa,b,c,d
TABLE 803.10.6 – CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 – DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
97 SECTION 805 – FACTORY-BUILT CHIMNEYS
SECTION 806 – METAL CHIMNEYS
99 CHAPTER 9 – SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 – GENERAL
SECTION 902 – MASONRY FIREPLACES
SECTION 903 – FACTORY-BUILT FIREPLACES
SECTION 904 – PELLET FUEL-BURNING APPLIANCES
SECTION 905 – FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 – FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 – INCINERATORS AND CREMATORIES
SECTION 908 – COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
100 SECTION 909 – VENTED WALL FURNACES
SECTION 910 – FLOOR FURNACES
SECTION 911 – DUCT FURNACES
SECTION 912 – INFRARED RADIANT HEATERS
101 SECTION 913 – CLOTHES DRYERS
SECTION 914 – SAUNA HEATERS
SECTION 915 – ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 – POOL AND SPA HEATERS
SECTION 917 – COOKING APPLIANCES
SECTION 918 – FORCED-AIR WARM-AIR FURNACES
102 SECTION 919 – CONVERSION BURNERS
SECTION 920 – UNIT HEATERS
SECTION 921 – VENTED ROOM HEATERS
SECTION 922 – KEROSENE AND OIL-FIRED STOVES
103 SECTION 923 – SMALL CERAMIC KILNS
SECTION 924 – STATIONARY FUEL CELL POWER PLANTS
105 CHAPTER 10 – BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 – GENERAL
SECTION 1002 – WATER HEATERS
SECTION 1003 – PRESSURE VESSELS
SECTION 1004 – BOILERS
106 SECTION 1005 – BOILER CONNECTIONS
SECTION 1006 – SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
107 SECTION 1007 – BOILER LOW-WATER CUTOFF
SECTION 1008 – STEAM BLOWOFF VALVE
SECTION 1009 – HOT WATER BOILER EXPANSION TANK
(Equation 10-1)
108 SECTION 1010 – GAUGES
SECTION 1011 – TESTS
109 CHAPTER 11 – REFRIGERATION
SECTION 1101 – GENERAL
SECTION 1102 – SYSTEM REQUIREMENTS
110 SECTION 1103 – REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 – SYSTEM APPLICATION REQUIREMENTS
111 TABLE 1103.1 – REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
113 TABLE 1104.3.2 – MAXIMUM PERMISSABLE QUANTITIES OF REFRIGERANTS
114 SECTION 1105 – MACHINERY ROOM, GENERAL REQUIREMENTS
(Equation 11-1)
(Equation 11-2)
115 SECTION 1106 – MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 – REFRIGERANT PIPING
116 SECTION 1108 – FIELD TEST
[F] SECTION 1109 – PERIODIC TESTING
117 CHAPTER 12 – HYDRONIC PIPING
SECTION 1201 – GENERAL
SECTION 1202 – MATERIAL
TABLE 1202.4 – HYDRONIC PIPE
TABLE 1202.5 – HYDRONIC PIPE FITTINGS
118 SECTION 1203 – JOINTS AND CONNECTIONS
119 SECTION 1204 – PIPE INSULATION
TABLE 1204.2: INSULATION THICKNESS FOR NOMINAL PIPE DIAMETERS
SECTION 1205 – VALVES
120 SECTION 1206 – PIPING INSTALLATION
SECTION 1207 – TRANSFER FLUID
SECTION 1208 – TESTS
SECTION 1209 – EMBEDDED PIPING
123 CHAPTER 13 – FUEL OIL PIPING AND STORAGE
SECTION 1301 – GENERAL
SECTION 1302 – MATERIAL
TABLE 1302.3 – FUEL OIL PIPING
SECTION 1303 – JOINTS AND CONNECTIONS
124 SECTION 1304 – PIPING SUPPORT
SECTION 1305 – FUEL OIL SYSTEM INSTALLATION
SECTION 1306 – OIL GAUGING
125 SECTION 1307 – FUEL OIL VALVES
SECTION 1308 – TESTING
127 CHAPTER 14 – SOLAR SYSTEMS
SECTION 1401 – GENERAL
SECTION 1402 – INSTALLATION
SECTION 1403 – HEAT TRANSFER FLUIDS
128 SECTION 1404 – MATERIALS
129 CHAPTER 15 – REFERENCED STANDARDS
ANSI
ARI
ASHRAE
ASME
130 ASTM
131 AWS
CSA
DOL
132 FS
ICC
IIAR
MSS
133 NAIMA
NFPA
SMACNA
UL
135 CHAPTER 16 – INSTALLATION AND TESTING OF OIL OR LIQUID FUEL-FIRED EQUIPMENT
SECTION 1601 – GENERAL
SECTION 1602 – EQUIPMENT PLACEMENT
SECTION 1603 – PILOT OPERATION
SECTION 1604 – BURNER OPERATION
SECTION 1605 – TEST METHODS
137 SECTION 1606 – EQUIPMENT
139 APPENDIX A – COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGH
FIGURE A-1 – ALL AIR FROM INSIDE THE BUILDING
FIGURE A-2 – ALL AIR FROM OUTDOORS – INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
140 FIGURE A-3 – ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE A-4 – ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS
141 FIGURE A-5 – CHIMNEY CONNECTOR SYSTEMS
143 APPENDIX B – RECOMMENDED PERMIT FEE SCHEDULE
B101 – MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 – FEE FOR REINSPECTION
B103 – TEMPORARY OPERATION INSPECTION FEE
B104 – SELF-CONTAINED UNITS LESS THAN 2 TONS
145 APPENDIX C – RECOMMENDED CAPACITIES FOR DOMESTIC KITCHEN EXHAUST HOODS
IMC APPENDIX C, TABLE C-1 – RECOMMENDED CAPACITIES FOR DOMESTIC KITCHEN EXHAUST HOODS
147 INDEX
151 MINNESOTA FUEL GAS CODE PREFACE
153 TABLE OF CONTENTS – MINNESOTA FUEL GAS CODE
155 MINNESOTA RULES, CHAPTER 1346 – MINNESOTA FUEL GAS CODE
1346.5050 – INCORPORATION BY REFERENCE
157 CHAPTER 2 – DEFINITIONS
SECTION 201 (IFGC) – GENERAL
SECTION 202 (IFGC) – GENERAL DEFINITIONS
167 CHAPTER 3 – GENERAL REGULATIONS
SECTION 301 (IFGC) – GENERAL
168 SECTION 302 (IFGC) – STRUCTURAL SAFETY
SECTION 303 (IFGC) – APPLIANCE LOCATION
169 SECTION 304 (IFGS) – COMBUSTION, VENTILATION, AND DILUTION AIR
171 SECTION 305 (IFGC) – INSTALLATION
SECTION 306 (IFGC) – ACCESS AND SERVICE SPACE
172 SECTION 307 (IFGC) – CONDENSATE DISPOSAL
173 SECTION 308 (IFGS) – CLEARANCE REDUCTION
FIGURE 308.2(1) – EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTIONS
FIGURE 308.2(2) – WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
174 FIGURE 308.2(3) – EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTIONS
SECTION 309 (IFGC) – ELECTRICAL
175 TABLE 308.2a-k – REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
177 CHAPTER 4 – GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) – GENERAL
SECTION 402 (IFGS) – PIPE SIZING
178 TABLE 402.3(1) – MAXIMUM CAPACITY OF PIPE IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 0.3-INCH WATER COLUMN
TABLE 402.3(2) – MAXIMUM CAPACITY OF PIPE IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 0.5-INCH WATER COLUMN
179 TABLE 402.3(3) – PIPE SIZING TABLE FOR 2 PSI PRESSURE CAPCITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 2.0 PSI WITH A 1.0 PSI PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
TABLE 402.3(4) – PIPE SIZING TABLE FOR 5 PSI PRESSURE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 5.0 PSI WITH A 3.5 PSI PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
180 TABLE 402.3(5) – PIPE SIZING TABLE FOR PRESSURES UNDER 1 POUND APPROXIMATE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR WITH PRESSURE DROP OF 0.3-INCH WATER COLUMN AND 0.6 SPECIFIC GRAVITY
TABLE 402.3(6) – PIPE SIZING TABLE FOR PRESSURES UNDER 1 POUND APPROXIMATE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR WITH PRESSURE DROP OF 0.5-INCH WATER COLUMN AND 0.6 SPECIFIC GRAVITY
181 TABLE 402.3(7) – PIPE SIZING TABLE FOR 1 POUND PRESSURE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 1.0 PSI WITH A 10-PERCENT PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
TABLE 402.3(8) – PIPE SIZING TABLE FOR 2 POUNDS CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 2.0 PSI WITH A 10-PERCENT PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
182 TABLE 402.3(9) – PIPE SIZING TABLE FOR 5 POUNDS PRESSURE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 5.0 PSI WITH A 10-PERCENT PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
TABLE 402.3(10) – PIPE SIZING TABLE FOR 10 POUNDS PRESSURE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 10.0 PSI WITH A 10-PERCENT PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
183 TABLE 402.3(11) – PIPE SIZING TABLE FOR 20 POUNDS PRESSURE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 20.0 PSI WITH A 10-PERCENT PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
TABLE 402.3(12) – PIPE SIZING TABLE FOR 50 POUNDS PRESSURE CAPACITY OF PIPES OF DIFFERENT DIAMETERS AND LENGTHS IN CUBIC FEET PER HOUR FOR AN INITIAL PRESSURE OF 50.0 PSI WITH A 10-PERCENT PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY
184 TABLE 402.3(13) – MAXIMUM CAPACITY OF SEMI-RIGID TUBING IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 0.3-INCH WATER COLUMN
TABLE 402.3(14) – MAXIMUM CAPACITY OF SEMI-RIGID TUBING IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 0.5-INCH WATER COLUMN
TABLE 402.3(15) – MAXIMUM CAPACITY OF SEMI-RIGID TUBING IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 1.0-INCH WATER COLUMN
185 TABLE 402.3(16) – MAXIMUM CAPACITY OF SEMI-RIGID TUBING IN CUBIC FEET PER HOUR FOR A GAS PRESSURE OF 2 PSI OR LESS AND A PRESSURE DROP OF 17-INCH WATAER COLUMN
186 TABLE 402.3(17) – MAXIMUM CAPACITY OF SEMI-RIGID TUBING IN CUBIC FEET OF GAS PER HOUR FOR A GAS PRESSURE OF 2.0 PSI OR LESS AND A PRESSURE DRIP OF 1.0 PSI
187 TABLE 402.3(18) – MAXIMUM CAPACITY OF SEMI-RIGID TUBING IN CUBIC FEET OF GAS PER HOUR FOR A GAS PRESSURE OF 5.0 PSI OR LESS AND A PRESSURE DROP OF 3.5 PSI
188 TABLE 402.3(19) – MAXIMUM CAPACITY OF CSST IN CUBIC FEET PER HOUR FOR GAS PRESSURE OF 0.5 PSI OR LESS AND A PRESSURE OF 0.5-INCH WATER COLUMN
TABLE 402.3(20) – MAXIMUM CAPACITY OF CSST IN CUBIC FEET PER HOUR FOR A GAS PRESSURE OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 3-INCH WATER COLUMN
189 TABLE 402.3(21) – MAXIMUM CAPACITY OF CSST IN CUBIC FEET PER HOUR FOR A GAS PRESSURE OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 6-INCH WATER COLUMN
TABLE 402.3(22) – MAXIMUM CAPACITY OF CSST IN CUBIC FEET PER HOUR FOR A GAS PRESSURE OF 2 PSI AND A PRESSURE DROP OF 1 PSI
190 TABLE 402.3(23) – MAXIMUM CAPACITY OF CSST IN CUBIC FEET PER HOUR FOR A GAS PRESSURE OF 5 PSI AND A PRESSURE DROP OF 3.5 PSI
TABLE 402.3(24) – MULTIPLIERS TO BE USED WITH TABLES 402.3(1) THROUGH 402.3(12) WHEN THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
191 TABLE 402.3(25) – PIPE SIZING SIZING BETWEEN FIRST STAGE (HIGH-PRESSURE REGULATOR) AND SECOND STAGE (LOW-PRESSURE REGULATOR)
192 TABLE 402.3(26) – SIZING BETWEEN SINGLE OR SECOND STAGE (LOW-PRESSURE REGULATOR) AND APPLIANCE
193 TABLE 402.3(27) – COPPER TUBE SIZING BETWEEN FIRST STAGE(HIGH-PRESSURE REGULATOR) AND SECOND STAGE (LOW-PRESSURE REGULATOR)
194 TABLE 402.3(28) – COPPER TUBE SIZING BETWEEN SINGLE OR SECOND STAGE (LOW-PRESSURE REGULATOR) AND APPLIANCE
TABLE 402.3(29) – MAXIMUM CAPACITY OF CSST IN THOUSANDS OF BTU PER HOUR OF UNDILUTED LIQUEFIED PETROLEUM GASES AT PRESSURE OF 11-INCH WATER COLUMN AND A PRESSURE DROP OF 0.5-INCH WATER COLUMN
195 TABLE 402.3(30) – MAXIMUM CAPACITY OF CSST IN THOUSANDS OF BTU PER HOUR OF UNDILUTED LIQUEFIED PETROLEUM GASES AT PRSSURE OF 2 PSI AND A PRESSURE DROP OF 1 PSAa
TABLE 402.3(31) – MAXIMUM CAPACITY OF CSST IN THOUSANDS OF BTU PER HOUR OF UNDILUTED LIQUEFIED PETROLEUM GASES AT A PRESSURE OF 5 PSI AND A PRESSURE DROP OF 3.5 PSIa
196 TABLE 402.3(32) – POLYETHYLENE PLASTIC PIPE SIZING SIZING BETWEEN FIRST-STAGE AND SECOND-STAGE REGULATOR
197 TABLE 402.3(33) – POLYETHYLENE PLASTIC TUBE SIZING
198 TABLE 402.3(34) – POLYEHYLENE PLASTIC TUBE SIZING
199 TABLE 402.3(35) – PIPE SIZING TABLE FOR NATURAL GAS
200 TABLE 402.3(36) – PIPE SIZING TABLE FOR NATURAL GAS
201 TABLE 402.3(37) – PIPE SIZING TABLE FOR NATURAL GAS
202 TABLE 402.3(38) – PIPE SIZING TABLE FOR NATURAL GAS
203 SECTION 403 (IFGS) – PIPING MATERIALS
204 TABLE 403.9.2 – SPECIFICATIONS FOR THREADING METALLIC PIPE
205 SECTION 404 (IFGC) – PIPING SYSTEM INSTALLATION
206 SECTION 405 (IFGS) – PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) – INSPECTION, TESTING AND PURGING
208 TABLE 406.7.1 – LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS FOR SERVICING OR MODIFICATION
TABLE 406.7.2 – LENGTH OF PIPING REQUIREING PURGING WITH INERT GAS BEFORE PLACING IN OPERATION
SECTION 407 (IFGC) – PIPING SUPPORT
SECTION 408 (IFGC) – DRIPS AND SLOPED PIPING
209 SECTION 409 (IFGC) – SHUTOFF VALVES
SECTION 410 (IFGC) – FLOW CONTROLS
210 SECTION 411 (IFGC) – APPLIANCE CONNECTIONS
SECTION 412 (IFGC) – LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING STATIONS
211 SECTION 413 (IFGC) – COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING STATIONS
212 TABLE 413.8.2.3 – SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) – SUPPLEMENTAL AND STANDBY GAS PRESSURE
SECTION 415 (IFGS) – PIPING SUPPPORT INTERVALS
TABLE 415.1 – SUPPORT OF PIPING
213 CHAPTER 5 – CHIMNEYS AND VENTS
SECTION 501 (IFGC) – GENERAL
214 SECTION 502 (IFGC) – VENTS
SECTION 503 (IFGS) – VENTING OF EQUIPMENT
216 TABLE 503.4 – TYPE OF VENTING SYSTEM TO BE USED
217 FIGURE 503.5.4 – TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT EQUIPMENT
218 FIGURE 503.6.6 – GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
219 FIGURE 503.6.10.1 – PLAN VIEW OF PRACTICAL SEPARATION METHOD FOR MULTISTORY GAS VENTING
220 TABLE 503.7.7a – CLEARANCES FOR CONNECTORS
222 TABLE 503.10.2.4 – MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 – MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT EQUIPMENT AND COMMERCIAL AND INDUSTRIAL INCENERATORS VENT CONNECTOR SIZE
224 SECTION 504 (IFGS) – SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
226 TABLE 504.2(1) – CAPACITY OF TYPE B DOUBLE-WALL GAS VENTS WHEN CONNECTED DIRECTLY TO A SINGLE CATEGORY I APPLIANCE
228 TABLE 504.2(2) – CAPACITY OF TYPE B DOUBLE-WALL VENTS WITH SINGLE-WALL METAL CONNECTORS SERVING A SINGLE CATEGORY I APPLIANCE
229 TABLE 504.2(3) – CAPACITY OF MASONRY CHIMNEY FLUE WITH TYPE B DOUBLE-WALL VENT CONNECTORS SERVING A SINGLE CATEGORY I APPLIANCE
230 TABLE 504.2(4) – CAPACITY OF MASONRY CHIMNEY FLUE WITH SINGLE-WALL VENT CONNECTORS SERVING A SINGLE CATEGORY I APPLIANCE
231 TABLE 504.2(5) – CAPACITY OF SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENTS SERVING A SINGLE DRAFT HOOD EQUIPPED APPLIANCE
232 TABLE 504.3.2 – MAXIMUM VENT CONNECTOR LENGTH
234 SECTION 505 (IFGC) – DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) – FACTORY-BUILT CHIMNEYS
235 TABLE 504.3(1) – CAPACITY OF TYPE B DOUBLE-WALL VENTS WITH TYPE B DOUBLE-WALL CONNECTORS SERVING TWO OR MORE CATEGORY I APPLIANCES
237 TABLE 504.3(2) – CAPACITY OF TYPE B DOUBLE-WALL VENT WITH SINGLE-WALL CONNECTORS SERVING TWO OR MORE CATEGORY I APPLIANCES
238 TABLE 504.3(3) – CAPACITY OF MASONRY CHIMNEY WITH TYPE B DOUBLE-WALL CONNECTORS SERVING TWO OR MORE CATEGORY I APPLIANCES
239 TABLE 504.3(4) – CAPACITY OF MASONRY CHIMNEY WITH SINGLE-WALL CONNECTORS SERVING TWO OR MORE CATEGORY I APPLIANCES
240 TABLE 504.3(5) – CAPACITY OF SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT SERVING TWO OR MORE DRAFT HOOD-EQUIPPED APPLIANCES
241 TABLE 504.3(6) – EXTERIOR MASONRY CHIMNEY, SINGLE NAT INSTALLATIONS WITH TYPE B DOUBLE-WALL VENT CONNECTORS
242 TABLE 504.3(7) – EXTERIOR MASONRY CHIMNEY, NAT + INSTALLATIONS WITH TYPE B DOUBLE-WALL VENT CONNECTORS
243 TABLE 504.3(8) – EXTERIOR MASONRY CHIMNEY, FAN + NAT INSTALLATIONS WITH TYPE B DOUBLE-WALL VENT CONNECTORS
245 CHAPTER 6 – SPECIFIC APPLIANCES
SECTION 601 (IFGC) – GENERAL
SECTION 602 (IFGC) – DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) – LOG LIGHTERS
SECTION 604 (IFGC) – VENTED DECORATIVE APPLIANCES
SECTION 605 (IFGC) – INCINERATORS AND CREMATORIES
SECTION 606 (IFGC) – COMMERCIAL – INDUSTRIAL INCINERATORS
SECTION 607 (IFGC) – VENTED WALL FURNACES
SECTION 608 (IFGC) – FLOOR FURNACES
246 SECTION 609 (IFGC) – DUCT FURNACES
SECTION 610 (IFGC) – DIRECT-FIRED MAKE-UP AIR HEATERS
247 SECTION 611 (IFGC) – DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 612 (IFGC) – CLOTHES DRYERS
SECTION 613 (IFGC) – CLOTHES DRYER EXHAUST
248 SECTION 614 (IFGC) – SAUNA HEATERS
SECTION 615 (IFGC) – ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 616 (IFGC) – POOL AND SPA HEATERS
SECTION 617 (IFGC) – FORCED-AIR WARM-AIR FURNACES
249 SECTION 618 (IFGC) – CONVERSION BURNERS
SECTION 619 (IFGC) – UNIT HEATERS
250 SECTION 620 (IFGC) – UNVENTED ROOM HEATERS
SECTION 621 (IFGC) – VENTED ROOM HEATERS
SECTION 622 (IFGC) – COOKING APPLIANCES
SECTION 623 (IFGC) – WATER HEATERS
SECTION 624 (IFGC) – REFRIGERATORS
SECTION 625 (IFGC) – GAS-FIRED TOILETS
251 SECTION 626 (IFGC) – AIR CONDITIONING EQUIPMENT
SECTION 627 (IFGC) – ILLUMINATING APPLIANCES
252 SECTION 628 (IFGC) – SMALL CERAMIC KILNS
SECTION 629 (IFGC) – INFRARED RADIANT HEATERS
SECTION 630 (IFGC) – BOILERS
SECTION 631 (IFGC) – EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 632 (IFGS) – CHIMNEY DAMPER OPENING AREA
TABLE 632.1 – FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
253 IFGC/IFGS CHAPTER 7 – REFERENCED STANDARDS
ANSI
254 ASME
ASTM
AWWA
DOTn
255 IAS
ICC
MSS
NFPA
256 UL
257 CHAPTER 8 – INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT
SECTION 801 – GENERAL
SECTION 802 – EQUIPMENT PLACEMENT
SECTION 803 – PILOT OPERATION
SECTION 804 – BURNER OPERATION
258 SECTION 805 – METHOD OF TEST
259 SECTION 806 – PRESSURE REGULATORS
SECTION 807 – EQUIPMENT INFORMATION
261 CHAPTER 9 – MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND INSTALLATION
GENERAL
TABLE 902 – DEMAND FACTORS FOR CALCULATING GAS PIPING SYSTEMS IN MANUFACTURED HOME PARKS AND COMMUNITIES
263 APPENDIX A (IFGS) – SIZING AND CAPACITIES OF GAS PIPING
264 TABLE A-1 – APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
267 APPENDIX B (IFGS) – SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 – TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH TYPE B DOUBLE-WALL VENT
FIGURE B-2 – TYPE B DOUBLE-WALL VENT SYSTEMS SERVING A SINGLE APPLIANCE WITH SINGLE-WALL METAL VENT CONNECTOR
268 FIGURE B-3 – VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 – VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 – ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT HOOD-EQUIPPED APPLIANCE
FIGURE B-6 – VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
269 FIGURE B-7 – VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 – MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 – MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 – ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
270 FIGURE B-11 – USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 – USE OF OFFSET COMMON VENT
FIGURE B-13 – MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 – MULTISTORY VENT SYSTEMS
271 FIGURE B-15 (EX AMPLE 1) – SINGLE DRAFT HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) – SINGLE FAN-ASSISTED APPLIANCE
272 FIGURE B-17 (EXAMPLE 4) – COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES
273 FIGURE B-18 (EXAMPLE 5A) – COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
274 TABLE B-1 – MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
275 APPENDIX C (IFGS) – EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C – EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
277 APPENDIX D (IFGS) – RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
279 IFGC APPENDIX E (IFGS)
280 IFGC APPENDIX E, TABLE E-1
283 INDEX
287 TABLE OF CONTENTS – MINNESOTA PLUMBING CODE
291 MINNESOTA RULES, CHAPTER 4715 MINNESOTA PLUMBING CODE
4715.0100 – DEFINITIONS
296 4715.0200 – BASIC PLUMBING PRINCIPLES
297 4715.0300 – GENERAL REGULATIONS OF PLUMBING CONSTRUCTION
4715.0310 – USE OF PUBLIC SEWER AND WATER SYSTEMS REQUIRED
4715.0320 – CONFORMANCE WITH CODE
4715.0330 – ALTERNATE FIXTURES, APPURTENANCES, MATERIALS, AND METHODS
298 4715.0340 – HEALTH AND SAFETY
299 4715.0400 – QUALITY OF MATERIALS
4715.0410 – IDENTIFICATION OF MATERIALS
4715.0420 – STANDARDS FOR PLUMBING MATERIALS
302 4715.0500 – WATER SUPPLY SYSTEMS
4715.0510 – WATER SERVICE PIPE
4715.0520 – WATER DISTRIBUTION PIPE
303 4715.0530 – BUILDING SEWERS
4715.0540 – STORM WATER AND YARD DRAINAGE (OUTSIDE FOUNDATION WALLS)
4715.0550 – STORM WATER OR CLEAR WATER DRAINAGE (WITHIN BUILDINGS UNDERGROUND)
4715.0560 – STORM WATER OR CLEAR WATER DRAINAGE (WITHIN BUILDINGS ABOVE GROUND)
4715.0570 – SOIL AND WASTE PIPING UNDERGOUND OR EMBEDDED
4715.0580 – SOIL AND WASTE PIPING ABOVE GROUND
304 4715.0590 – VENT PIPING BELOW GROUND
4715.0600 – VENT PIPING ABOVE GROUND
4715.0610 – SPECIAL WASTES
4715.0620 – SUBSOIL DRAINS
4715.0630 – SPECIAL MATERIALS
305 4715.0640 – FIXTURE MATERIALS
306 JOINTS AND CONNECTIONS
4715.0700 – TIGHTNESS
4715.0710 – ASBESTOS CEMENT SEWER PIPE JOINTS
4715.0720 – BITUMIZED FIBER DRAIN PIPE JOINT
4715.0730 – BURNED LEAD JOINTS
4715.0740 – CAULKED JOINTS
4715.0750 – CEMENT MORTAR JOINTS
4715.0760 – COLD JOINT COMPOUND, TAR BASE
4715.0770 – FLARED JOINTS
4715.0780 – GASKET TYPE JOINTS
4715.0790 – HOT-POURED JOINTS
307 4715.0800 – MECHANICAL JOINTS
4715.0805 – PUSH-ON JOINTS
4715.0810 – PLASTIC JOINTS
308 4715.0815 – JOINTS IN CHEMICAL WASTE PIPE
4715.0820 – SOLDERED OR BRAZED JOINTS
4715.0830 – SCREWED JOINTS
4715.0840 – WIPED JOINTS
4715.0850 – USE OF JOINTS
4715.0860 – SPECIAL JOINTS
309 4715.0870 – FLANGED FIXTURE CONNECTIONS
4715.0880 – PROHIBITED JOINTS AND CONNECTIONS
4715.0890 – INCREASERS AND REDUCERS
310 4715.0900 – FIXTURE TRAP REQUIREMENTS
4715.0910 – TRAPS DESCRIBED
4715.0920 – TRAP PROTECTION
4715.0930 – SIZES OF TRAPS
4715.0940 – SLIP JOINTS AND UNIONS
4715.0950 – TRAP SEALS
4715.0960 – TRAPS PROHIBITED
4715.0970 – TRAP CLEANOUTS
4715.1000 – LOCATION
311 4715.1010 – SIZE OF CLEANOUTS
4715.1020 – CLEANOUT MATERIALS
4715.1030 – CLEANOUTS TO BE ACCESSIBLE
312 4715.1100 – INTERCEPTORS AND SEPARATORS REQUIRED
4715.1110 – GREASE INTERCEPTORS FOR COMMERCIAL BUILDINGS
4715.1115 – EXTERIOR GREASE INTERCEPTORS
4715.1120 – OIL AND FLAMMABLE LIQUIDS SEPARATOR
313 4715.1130 – INTERCEPTORS AND SEPARATORS FOR SPECIFIC INSTALLATIONS
4715.1140 – VENTING OF INTERCEPTORS AND SEPARATORS
4715.1150 – MAINTENANCE OF INTERCEPTORS AND SEPARATORS
4715.1160 – BACKWATER VALVES
315 4715.1200 – CONNECTIONS TO PLUMBING SYSTEM REQUIRED
4715.1210 – REQUIRED MINIMUM NUMBER OF FIXTURES
4715.1220 – INSTALLATION OF FIXTURES
4715.1230 – AUTOMATIC CLOTHES WASHERS
4715.1240 – BATHTUBS
4715.1250 – DISHWASHING EQUIPMENT
4715.1260 – DRINKING FOUNTAINS
4715.1300 – FLOOR DRAINS
316 4715.1305 – ELEVATOR PIT DRAIN
4715.1310 – FOOD-WASTE GRINDER UNITS
4715.1320 – FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
4715.1330 – FLUSH TANKS
4715.1340 – FLUSHOMETER VALVES
317 4715.1350 – GARBAGE CAN WASHERS
4715.1360 – LAUNDRY TRAYS
4715.1370 – LAVATORIES
4715.1380 – SHOWERS
4715.1390 – SINKS
4715.1400 – SPECIAL PLUMBING FIXTURES
318 4715.1410 – URINALS
4715.1420 – WATER CLOSETS
319 4715.1430 – HANGERS AND SUPPORTS
4715.1440 – PROTECTION OF PLASTIC PIPE
320 4715.1500 – INDIRECT WASTE CONNECTIONS
4715.1510 – INDIRECT WASTE PIPING
4715.1520 – CONNECTIONS FROM WATER DISTRIBUTION SYSTEM
4715.1530 – STERILIZERS
4715.1540 – POTABLE CLEAR WATER WASTES
4715.1550 – DRINKING FOUNTAINS
4715.1560 – SWIMMING POOLS
4715.1570 – METHOD OF PROVIDING AN AIR GAP
4715.1580 – METHOD OF PROVIDING AN AIR BREAK
4715.1590 – RECEPTORS OR SUMPS
321 4715.1600 – CHEMICAL WASTES
4715.1610 – STEAM AND HOT WATER WASTES
322 4715.1700 – WATER REQUIRED
4715.1710 – WATER SERVICE
4715.1720 – DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
4715.1730 – SIZE OF FIXTURE BRANCH
4715.1740 – WATER PRESSURE
323 4715.1750 – WATER HAMMER
4715.1760 – SUPPLY DEMAND
4715.1770 – MINIMUM PRESSURES REQUIRED IN WATER DISTRIBUTION SYSTEM
4715.1800 – WATER SUPPLY CONTROL VALVES
4715.1810 – WATER PRESSURE BOOSTER SYSTEMS
325 4715.1900 – DESIGN, MAINTENANCE AND INSTALLATION
4715.1910 – IDENTIFICATION OF POTABLE AND NONPOTABLE WATER
4715.1911 – TOXIC MATERIALS AND USED PIPE
4715.1912 – USED WATER RETURN PROHIBITED
4715.1920 – CROSS-CONNECTION CONTROL
4715.1940 – POTABLE WATER CONNECTIONS TO HEATING OR COOLING SYSTEMS
4715.1941 – HEAT EXCHANGERS
326 4715.1950 – PROHIBITED CONNECTIONS TO FIXTURES AND EQUIPMENT
4715.1960 – REFRIGERATING UNIT CONDENSERS AND COOLING JACKETS
4715.2000 – WATER OUTLETS
4715.2010 – MINIMUM REQUIRED AIR GAP
327 4715.2020 – DEVICES OR ASSEMBLIES FOR THE PROTECTION OF THE POTABLE WATER SUPPLY
4715.2030 – APPROVAL OF DEVICES OR ASSEMBLIES
4715.2100 – BACKFLOW PREVENTERS
4715.2110 – TYPES OF DEVICES REQUIRED WHERE AN AIR GAP CANNOT BE PROVIDED1
328 4715.2120 – LOCATION OF BACKFLOW PREVENTERS
4715.2150 – CONNECTIONS NOT SUBJECT TO BACK PRESSURE
329 4715.2160 – CONNECTIONS SUBJECT TO BACK PRESSURE
4715.2161 – INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS
4715.2162 -DOUBLE CHECK – DOUBLE GATE VALVE ASSEMBLIES
4715.2163 – CARBONATED BEVERAGE MACHINES
4715.2165 – CHEMICAL/SOAP DISPENSING SYSTEMS
4715.2170 – BAROMETRIC LOOP
4715.2180 – HOT WATER SUPPLY SYSTEM
4715.2190 – COMBINATION WATER AND SPACE HEATING EQUIPMENT
330 4715.2200 – PRESSURE RELIEF VALVES AND TEMPERATURE RELIEF VALVES DEVICES REQUIRED
4715.2210 – PRESSURE RELIEF VALVES
4715.2215 – THERMAL EXPANSION CONTROL
4715.2220 – HOT WATER STORAGE TANKS
4715.2230 – TANKLESS AND INSTANTANEOUS TYPE HEATERS
4715.2240 – ACCESS TO WATER HEATERS
4715.2250 – DISINFECTION OF POTABLE WATER SYSTEM
331 4715.2280 – WATER METER INSTALLATION
332 4715.2300 – LOAD ON DRAINAGE PIPING
4715.2310 – SELECTING SIZE OF DRAINAGE PIPING
333 4715.2320 – MINIMUM SIZE OF SOIL AND WASTE STACKS
4715.2330 – MINIMUM SIZE OF STACK VENT OR VENT STACK
4715.2340 – PROVISIONS FOR FUTURE FIXTURES
4715.2350 – MINIMUM SIZE OF UNDERGROUND DRAINAGE PIPING
4715.2360 – SIZING OFFSETS ON DRAINAGE PIPING
4715.2370 – FIXTURE CONNECTIONS TO AN OFFSET OF MORE THAN 45 DEGREES OR AT BASE OF STACK
334 4715.2400 – PITCH ON HORIZONTAL DRAINAGE PIPING
4715.2410 – CHANGE IN DIRECTION
4715.2420 – PROHIBITED FITTINGS AND CONNECTIONS
4715.2430 – BUILDING DRAINS BELOW BUILDING SEWER
4715.2440 – DESIGN OF SUMPS
336 4715.2500 – SELECTING SIZE OF VENT PIPING
4715.2510 – PROTECTION OF TRAP SEALS
4715.2520 – VENT STACKS AND STACK VENTS
337 4715.2530 – VENT TERMINALS
4715.2540 – VENT GRADES AND CONNECTIONS
4715.2550 – WET VENTING
338 4715.2560 – STACK VENTING
4715.2570 – INDIVIDUAL FIXTURE REVENTING REQUIRED
4715.2580 – COMMON VENTS
4715.2600 – CIRCUIT AND LOOP VENTING
4715.2610 – FIXTURES BACK-TO-BACK
4715.2620 – FIXTURE VENTS
339 4715.2630 – VENTS FOR FIXTURE TRAP BELOW TRAP DIP
4715.2640 – YOKE VENTS FOR STACKS OF MORE THAN FIVE BRANCH INTERVALS
4715.2650 – COMBINATION WASTE AND VENT SYSTEM
4715.2655 – ISLAND FIXTURE VENTING
4715.2660 – VENTING OF SUMPS AND SEWERS
340 4715.2700 – STORM SEWER SYSTEMS
4715.2710 – SIZE OF BUILDING STORM DRAINS AND LEADERS
4715.2720 – SUBSOIL DRAINS
4715.2730 – BUILDING SUBDRAINS
4715.2740 – TRAPS ON STORM DRAINS AND LEADERS
4715.2750 – CONDUCTORS AND CONNECTIONS
341 4715.2760 – ROOF AND DECK DRAINS
4715.2770 – PROVISIONS FOR EXPANSION
4715.2780 – CONTROL FLOW STORM WATER DRAINAGE FOR DEAD LEVEL LOADS
342 4715.2800 – INSPECTIONS
4715.2810 – NOTIFICATIONS
4715.2820 – METHOD OF TESTING
343 4715.2830 – COVERING OF WORK
4715.2840 – DEFECTIVE WORK
4715.2850 – AIR TEST OF DEFECTIVE PLUMBING
4715.2860 – MAINTENANCE
4715.2870 – DISINFECTION OF WATER PIPING
4715.2880 – BUILDING SEWER
4715.2890 – CERTIFICATE OF APPROVAL
344 4715.3130 – PLANS AND SPECIFICATIONS
4715.3140 – EXAMINATION AND LICENSING OF PLUMBERS
4715.3150 – FEES
4715.3160 – EXPIRATION OF LICENSES
345 4715.3170 – REGISTRATION OF PLUMBERS APPRENTICE
4715.3500 – GENERAL
346 4715.3600 – TOTAL DAILY WATER REQUIREMENTS
347 4715.3700 – DETERMINATION OF PEAK DEMAND
362 4715.3800 – RECOMMENDED GUIDE FOR SIZING WATER SUPPLY SYSTEM
365 4715.4100 – USEFUL INFORMATION
370 4715.5000 – SCOPE AND APPLICABILITY
4715.5100 – DEFINITIONS
4715.5200 – CONNECTION WITH WATER DISTRIBUTION SYSTEM
4715.5300 – EQUIPMENT DRAIN
4715.5400 – LOCATION
4715.5500 – REGENERATION SANITATION PROCEDURES
371 4715.5600 – VARIANCE
4715.5700 – EQUIPMENT AND MATERIALS USED IN INSTALLATIONS
4715.5800 – LICENSING
4715.5900 – FEES
4715.6000 – RENEWAL
MN Mechanical FuelGas PlumbingCode 2000
$30.33