Minnesota Mechanical and Fuel Gas Code with ANSI/ASHRAE Standard 154-2011

Published By Publication Date Number of Pages
MN 2015 371
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a soft cover fully integrated custom Minnesota code based on the 2012 International Mechanical Code® and 2012 International Fuel Gas Code® with ANSI/ASHRAE Standard 154-2011, Ventilation for Commercial Cooking Operations. This code also includes Minnesota chapter 1300 Administration. The PDF is a fully integrated custom Minnesota code based on the 2012 International Mechanical Code® and 2012 International Fuel Gas Code® with ANSI/ASHRAE Standard 154-2011, Ventilation for Commercial Cooking Operations. This code also includes Minnesota chapter 1300 Administration.

PDF Catalog

PDF Pages PDF Title
1 2015 MINNESOTA MECHANICAL AND FUEL GAS CODE WITH ANSI / ASHRAE STANDARD 154-2011
2 2015 MINNESOTA MECHANICAL AND FUEL GAS CODE WITH ANSI / ASHRAE STANDARD 154-2011 TITLE PAGE
3 COPYRIGHT
4 MINNESOTA DEPARTMENT OF LABOR & INDUSTRY
5 IMPORTANT DISCLAIMER
6 2015 MINNESOTA MECHANICAL CODE SYMBOLS AND NOTATIONS IN THE CODE
8 2015 MINNESOTA BUILDING CODE ADMINISTRATION TABLE OF CONTENTS
10 2015 MINNESOTA BUILDING CODE ADMINISTRATION
1300.0010 ADMINISTRATION
1300.0020 TITLE
1300.0030 PURPOSE AND APPLICATION
1300.0040 SCOPE
11 1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE
1300.0060 OPTIONAL ADMINISTRATION
1300.0070 DEFINITIONS
12 1300.0080 CODE ADOPTION AND AMENDMENTS
1300.0090 DEPARTMENT OF BUILDING SAFETY
1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL
14 1300.0120 PERMITS
16 1300.0130 CONSTRUCTION DOCUMENTS
17 1300.0140 VIOLATIONS
1300.0150 VIOLATIONS, PENALTY
1300.0160 FEES
18 1300.0170 STOP WORK ORDER
1300.0180 UNSAFE BUILDINGS OR STRUCTURES
19 1300.0190 TEMPORARY STRUCTURES AND USES
1300.0210 INSPECTIONS
20 1300.0215 PLUMBING
1300.0220 CERTIFICATE OF OCCUPANCY
21 1300.0225 MAINTENANCE
1300.0230 BOARD OF APPEALS
22 1300.0240 DISCLAIMER CLAUSE
1300.0250 SEVERABILITY
24 2015 MINNESOTA MECHANICAL CODE
TABLE OF CONTENTS
28 2015 MINNESOTA MECHANICAL CODE
1346.0050 TITLE; INCORPORATION BY REFERENCE
1346.0060 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES
1346.0101 SCOPE
29 1346.0102 EXISTING INSTALLATIONS
1346.0103 MAINTENANCE
1346.0104 ADDITIONS, ALTERATIONS, RENOVATIONS, OR REPAIRS
1346.0105 WORK EXEMPT FROM PERMIT
1346.0106 REQUIRED INSPECTIONS
1346.0107 (REPEALED)
1346.0108 AUTHORITY TO CONDEMN MECHANICAL SYSTEMS
1346.0109 AUTHORITY TO ORDER DISCONNECTION OF ENERGY SOURCES
1346.0110 CONNECTION AFTER ORDER TO DISCONNECT
30 CHAPTER 1 SCOPE AND ADMINISTRATION DELETED
32 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
44 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
45 SECTION 302 PROTECTION OF STRUCTURE
46 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
48 SECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
50 SECTION 307 CONDENSATE DISPOSAL
TABLE 307.2.2 CONDENSATE DRAIN SIZING
51 [B] SECTION 308 CLEARANCE REDUCTION
SECTION 309 TEMPERATURE CONTROL
52 TABLE 308.6 CLEARANCE REDUCTION METHODSb
[F] SECTION 310 EXPLOSION CONTROL
[F] SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
54 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
SECTION 402 NATURAL VENTILATION
55 SECTION 403 MECHANICAL VENTILATION
56 TABLE 403.3 MINIMUM VENTILATION RATES
57 TABLE 403.3—continued MINIMUM VENTILATION RATES
58 TABLE 403.3—continued MINIMUM VENTILATION RATES
59 EQUATION 4-1
TABLE 403.3.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
60 TABLE 403.3.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
61 SECTION 406 VENTILATION OF UNINHABITED SPACES
62 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
63 TABLE 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN DWELLING UNITS
64 TABLE 501.4.2 MAKEUP AIR OPENING SIZING TABLE FOR NEW AND EXISTING DWELLING UNITS
66 TABLE 501.4.3(1) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN EXISTING DWELLING UNITS (Refer to Item 4 in Section 501.4.3 to determine applicability of this table)
67 TABLE 501.4.3(2) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN EXISTING DWELLING UNITS (Refer to Item 5 in Section 501.4.3 to determine applicability of this table)
68 TABLE 501.4.3(3) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN EXISTING DWELLING UNITS (Refer to Item 6 in Section 501.4.3 to determine applicability of this table)
69 SECTION 502 REQUIRED SYSTEMS
EQUATION 5-1
75 SECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST
76 TABLE 504.6.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
77 SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
78 SECTION 507 COMMERCIAL KITCHEN HOODS
79 TABLE 507.2.1 APPLIANCE DUTY CLASSIFICATIONS BY APPLIANCE TYPE
80 TABLE 507.2.2 TYPE II HOOD REQUIREMENTS BY APPLIANCE DESCRIPTION
81 TABLE 507.2.2.1 TYPE II HOOD MINIMUM NET EXHAUST AIRFLOW RATES
TABLE 507.2.2.2 MINIMUM OVERHANG REQUIREMENTS FOR TYPE II
82 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
84 TABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
85 SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
86 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
87 EQUATION 5-2
EQUATION 5-3
88 EQUATION 5-4
90 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
92 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
93 SECTION 602 PLENUMS
94 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS
96 SECTION 604 INSULATION
97 SECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
98 [B] SECTION 607 DUCT AND TRANSFER OPENINGS
TABLE 607.3.2.1 FIRE DAMPER RATING
104 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
106 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
107 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
108 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCE
109 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCE
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
110 SECTION 805 FACTORY-BUILT CHIMNEYS
111 SECTION 806 METAL CHIMNEYS
112 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
113 SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
114 SECTION 913 CLOTHES DRY
SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIAN
115 SECTION 918 FORCED-AIR WARM-AIR FURNACES
116 SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 RADIANT HEATING SYSTEMS
117 SECTION 928 EVAPORATIVE COOLING EQUIPMENT
118 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
119 SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS
TABLE 1004.3.1 BOILER TOP CLEARANCES
120 SECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF
121 SECTION 1008 STEAM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
SECTION 1010 GAUGES
SECTION 1011 TESTS
122 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS
123 SECTION 1103 REFRIGERATION SYSTEM CLASSIFIC
124 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
125 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
126 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
127 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
128 SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
129 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
EQUATION 11-1
130 EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 REFRIGERANT PIPING
132 SECTION 1108 FIELD TEST
[F] SECTION 1109 PERIODIC TESTI
134 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4—continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS
135 SECTION 1203 JOINTS AND CONNECTIONS
137 SECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
138 SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
140 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS
141 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALL
142 SECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
144 CHAPTER 14 SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION
145 SECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 MATERIALS
146 CHAPTER 15 REFERENCED STANDARDS
ACCA
AHRI
AMCA
ANSI
147 ASHRAE
ASME
ASSE
148 ASTM
149 AWS
AWWA
150 CSA
DOL
FS
ICC
151 IIAR
MSS
NAIMA
NFPA
152 SMACNA
UL
154 CHAPTER 16 INSTALLATION AND TESTING OF OIL OR LIQUID FUEL-FIRED EQUIPMENT
SECTION 1601
SECTION 1602
SECTION 1603
SECTION 1604
SECTION 1605
156 SECTION 1606
158 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
159 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
160 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
162 INDEX
168 ANSI/ASHRAE STANDARD 154-2001 VENTILATION FOR COMMERCIAL COOKING OPERATIONS
169 ASHRAE STANDING STANDARD PROJECT COMMITTEE 154
ASHRAE STANDARDS COMMITTEE 2010–2011
SPECIAL NOTE
DISCLAIMER
ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDS
170 COPYRIGHT
CONTENTS
171 FOREWORD
1. PURPOSE
2. SCOPE
3. DEFINITIONS
175 4. EXHAUST HOODS
176 TABLE 1 TYPE II HOOD REQUIREMENTS BY APPLIANCE DESCRIPTION
177 TABLE 2 TYPE I HOOD REQUIREMENTS BY APPLIANCE TYPE
TABLE 3 MINIMUM OVERHANG REQUIREMENTS FOR TYPE II HOODS
178 TABLE 4 TYPE II HOOD MINIMUM NET EXHAUST AIRFLOW RATES
FIGURE 1 3×3 FT PARTIAL SIDE PANEL
5. EXHAUST SYSTEMS
180 6. REPLACEMENT AIR
181 7. SYSTEM CONTROLS
8. REFERENCES
182 INFORMATIVE APPENDIX A—EXAMPLES OF AIR BALANCING
A1. CONVENTIONAL AIR BALANCING
TABLE A-1 AIR BALANCE FOR CONVENTIONAL RESTAURANT
FIGURE A-1 CONVENTIONAL RESTAURANT AIR BALANCE EXAMPLE
183 A2. BEST PRACTICE AIR BALANCING
TABLE A-2 AIR BALANCE FOR BEST PRACTICE RESTAURANT
FIGURE A-2 BEST PRACTICES RESTAURANT AIR BALANCE EXAMPLE
A3. PRESSURE DIFFERENTIALS
184 INFORMATIVE APPENDIX B—ALTERNATIVE AIRFLOW CALCULATION METHOD
B1. EXHAUST AIRFLOW CALCULATION
EQUATION B-1
TABLE B-1 UNLISTED HOOD EFFECTIVENESS VALUES
TABLE B-2 REDUCTION FACTORS
B2. THERMAL PLUME CALCULATION
EQUATION B-2
EQUATION B-3
EQUATION B-4
B3. AIRFLOW CALCULATION EXAMPLE
185 TABLE B-3 EXAMPLE APPLIANCE SPECIFICATIONS
186 INFORMATIVE APPENDIX C—HOOD ENERGY SAVINGS CALCULATION
EQUATION D-1
187 INFORMATIVE APPENDIX D—USING ASHRAE STANDARD 154 TO DETERMINE HOOD OVERHANGS AND EXHAUST AIRFLOWS
TABLE D-1 MINIMUM HOOD LENGTH
TABLE D-2 MINIMUM HOOD DEPTH
188 TABLE D-3 HOODED APPLIANCE HEAT GAIN ESTIMATIONS
TABLE D-4 UNHOODED APPLIANCE HEAT GAIN ESTIMATIONS
189 INFORMATIVE APPENDIX E—INFORMATIVE BIBLIOGRAPHY
190 INSTRUCTIONS FOR SUBMITTING A PROPOSED CHANGE TO THIS STANDARD UNDER CONTINUOUS MAINTENANCE
ELECTRONIC PREPARATION/SUBMISSION OF FORM FOR PROPOSING CHANG
191 FORM FOR SUBMITTAL OF PROPOSED CHANGE TO AN ASHRAE STANDARD UNDER CONTINUOUS MAINTENANCE
192 POLICY STATEMENT DEFINING ASHRAE’S CONCERN FOR THE ENVIRONMENTAL IMPACT OF ITS ACTIVITIES
193 ABOUT ASHRAE
194 2015 MINNESOTA FUEL GAS CODE
2015 MINNESOTA FUEL GAS CODE SYMBOLS AND NOTATIONS IN THE CODE
196 TABLE OF CONTENTS
198 2015 MINNESOTA FUEL GAS CODE
1346.5050 INCORPORATION BY REFERENCE
1346.5060 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODE
1346.5101 ADMINISTRATION
200 CHAPTER 1 SCOPE AND ADMINISTRATION
202 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
212 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
213 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
214 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
215 TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING
EQUATION 3-1
EQUATION 3-2
217 SECTION 305 (IFGC) INSTALLATION
218 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
219 SECTION 307 (IFGC) CONDENSATE DISPOSAL
220 SECTION 308 (IFGS) CLEARANCE REDUCTION
TABLE 308.2 a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
221 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
222 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
224 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
EQUATION 4-1
EQUATION 4-2
225 TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
TABLE 402.2 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
226 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
227 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
228 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
229 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
230 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
231 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
232 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
233 TABLE 402.4(8) SEMIRIGID COPPER TUBING
234 TABLE 402.4(9) SEMIRIGID COPPER TUBING
235 TABLE 402.4(10) SEMIRIGID COPPER TUBING
236 TABLE 402.4(11) SEMIRIGID COPPER TUBING
237 TABLE 402.4(12) SEMIRIGID COPPER TUBING
238 TABLE 402.4(13) SEMIRIGID COPPER TUBING
239 TABLE 402.4(14) SEMIRIGID COPPER TUBING
240 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
241 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
242 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
243 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
244 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
245 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
246 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
247 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
248 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
249 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
250 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
251 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
252 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
253 TABLE 402.4(29) SEMIRIGID COPPER TUBING
254 TABLE 402.4(30) SEMIRIGID COPPER TUBING
255 TABLE 402.4(31) SEMIRIGID COPPER TUBING
256 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
257 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
258 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
259 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
260 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
261 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
263 SECTION 403 (IFGS) PIPING MATERIALS
264 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
265 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
267 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
268 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
269 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
270 FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION 409 (IFGC) SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
271 SECTION 410 (IFGC) FLOW CONTROLS
272 SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
273 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
274 TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
275 SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
278 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
279 SECTION 502 (IFGC) VENTS
SECTION 503 (IFGS) VENTING OF APPLIANCES
281 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
283 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
286 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
TABLE 503.10.5a CLEARANCES FOR CONNECTORS
289 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
291 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
293 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
294 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
295 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
296 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
297 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
TABLE 504.2(2)-continued TYPE B DOUBLE-WALL GAS VENT
298 TABLE 504.2(3) MASONRY CHIMNEY
299 TABLE 504.2(3)—continued MASONRY CHIMNEY
300 TABLE 504.2(4) MASONRY CHIMNEY
301 TABLE 504.2(4)—continued MASONRY CHIMNEY
302 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
303 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
306 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
307 TABLE 504.3(1)-continued TYPE B DOUBLE-WALL VENT
308 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
309 TABLE 504.3(3) MASONRY CHIMNEY
310 TABLE 504.3(4) MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY-continued
311 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
312 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
313 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
314 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
315 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
316 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
317 TABLE 614.6.5.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
318 SECTION 615 (IFGC) SAUNA HEATERS
SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
319 SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
320 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
321 SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
322 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
323 SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
324 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
325 SECTION 704 (IFGC) PIPING, USE AND HANDLING
326 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
327 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
328 SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
330 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
331 ASME
ASTM
CGA
CSA
332 DOTn
ICC
MSS
NFPA
SUBPART 1 CHAPTER 9 INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPEMENT
SUBPART 2 INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT; GENERAL
SUBPART 3 PLACING EQUIPMENT IN OPERATION
SUBPART 4 PILOT OPERATION
SUBPART 5 BURNER OPERATION
SUBPART 6 METHOD OF TEST
333 UL
334 1346.5900 CHAPTER 9 INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT
SUBPART 7 PRESSURE REGULATORS
SUBPART 8 EQUIPMENT INFORMATION
336 TABLE 1002 DEMAND FACTORS FOR CALCULATING GAS PIPING SYSTEMS IN MANUFACTURED HOME PARKS AND COMMUNITIES
338 1346.6000 CHAPTER 10 MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND APPLIANCE INSTALLATION
SUBPART 1 IFGC CHAPTER 10 MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND APPLIANCE INSTALLATION
TABLE 1002 DEMAND FACTORS FOR CALCULATING GAS PIPING SYSTEMSIN MANUFACTURED HOME PARKS AND COMMUNITIES
SUBPART 2 GENERAL
SUBPART 3 REQUIRED GAS SUPPLY
SUBPART 4 INSTALLATION
SUBPART 5 MANUFACTURED HOME LOT SHUTOFF VALVE
SUBPART 6 MANUFACTURED HOME LOT GAS OUTLET
SUBPART 7 MECHANICAL PROTECTION
SUBPART 8 METERS
339 SUBPART 9 METER SHUTOFF VALVE
SUBPART 10 GAS PIPE SIZING
SUBPART 11 MAINTENANCE
340 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
341 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
342 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
343 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
345 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
346 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 USE OF SIZING CHARTS
347 FIGURE A.6(a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC)
A.7 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
348 FIGURE A.6(b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above)
349 FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM
350 FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
352 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
353 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
354 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
355 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
356 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
357 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
359 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
360 FIGURE B-19
362 1346.6010 APPENDIX C
TABLE C-1 RECOMMENDED CAPACITIES FOR DOMESTIC KITCHEN EXHAUST HOODS
364 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
366 APPENDIX E ( IFGC) WORKSHEET E-1
368 INDEX
MN MechFuelGasCode 2015 2nd
$62.29