Shopping Cart

No products in the cart.

MN MinnesotaFireCode 2015

$45.83

Minnesota Fire Code

Published By Publication Date Number of Pages
MN 2015 586
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom Minnesota code based on the 2012 International Fire Code®

PDF Catalog

PDF Pages PDF Title
1 2015 MINNESOTA STATE FIRE CODE
2 COPYRIGHT
3 MINNESOTA DEPARTMENT OF PUBLIC SAFETY STATE FIRE MARSHAL DIVISION
4 IMPORTANT DISCLAIMER
5 SELECTED MINNESOTA FIRE PREVENTION STATUTES
299F.011 STATE FIRE CODE; ADMINISTRATION AND ENFORCEMENT
6 299F.013 FUEL DISPENSING
299F.014 PETROLEUM STORAGE TANKS; TANK VEHICLE PARKING
7 299F.30 FIRE DRILL IN SCHOOL; DOORS AND EXITS
299F.362 SMOKE DETECTOR; INSTALLATION; RULES; PENALTY
8 299F.50 DEFINITIONS (Carbon Monoxide)
299F.51 REQUIREMENTS FOR CARBON MONOXIDE ALARMS
9 FIRE SPRINKLER STATUTES
299M.01 DEFINITIONS
10 299M.03 LICENSE OR CERTIFICATE REQUIRED
FIRE INVESTIGATIONS AND CRIMINAL STATUTES
299F.04 ORIGIN OF FIRE INVESTIGATED; COMPUTERIZED ARSON DATA
11 299F.08 PREMISES, WHEN ENTERED
12 609.562 ARSON IN THE SECOND DEGREE
609.563 ARSON IN THE THIRD DEGREE
13 609.5631 ARSON IN THE FOURTH DEGREE
609.5632 ARSON IN THE FIFTH DEGREE
609.5633 USE OF IGNITION DEVICES; PETTY MISDEMEANOR
609.564 EXCLUDED FIRES
609.5641 WILDFIRE ARSON
14 609.576 NEGLIGENT FIRES; DANGEROUS SMOKING
609.686 FALSE FIRE ALARMS; TAMPERING WITH OR INJURING FIRE ALARM SYSTEM
15 EFFECTIVE DATES OF MINNESOTA BUILDING AND FIRE CODES
17 OCCUPANCY CLASSIFICATIONS MN STATE FIRE CODE – 2015
19 PREFACE
23 EFFECTIVE USE OF THE INTERNATIONAL FIRE CODE
37 LEGISLATION
39 TABLE OF CONTENTS
49 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—GENERAL PROVISIONS
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 APPLICABILITY
51 PART 2—ADMINISTRATIVE PROVISIONS
SECTION 103 DEPARTMENT OF FIRE PREVENTION
52 SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES
54 SECTION 105 PERMITS
56 TABLE 105.6.8 PERMIT AMOUNTS FOR COMPRESSED GASES
TABLE 105.6.10 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
58 TABLE 105.6.20 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
TABLE 105.6.20—continued PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
61 SECTION 106 INSPECTIONS
SECTION 107 MAINTENANCE
SECTION 108 BOARD OF APPEALS
62 SECTION 109 VIOLATIONS
SECTION 110 UNSAFE BUILDINGS
SECTION 111 STOP WORK ORDER
63 SECTION 112 SERVICE UTILITIES
SECTION 113 FEES
65 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
69 TABLE CARE FACILITY CLASSIFICATIONS
70 TABLE CARE FACILITY CLASSIFICATIONS—(continued)
99 PART II—GENERAL SAFETY PROVISIONS
CHAPTER 3 GENERAL REQUIREMENTS
SECTION 301 GENERAL
SECTION 302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
SECTION 304 COMBUSTIBLE WASTE MATERIAL
100 SECTION 305 IGNITION SOURCES
SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM
SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
101 SECTION 308 OPEN FLAMES
102 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
103 SECTION 310 SMOKING
SECTION 311 VACANT PREMISES
104 SECTION 312 VEHICLE IMPACT PROTECTION
SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS
105 SECTION 315 GENERAL STORAGE
106 SECTION 316 HAZARDS TO FIRE FIGHTERS
SECTION 317 ROOFTOP GARDENS AND LANDSCAPED ROOFS
107 SECTION 318 LAUNDRY CARTS
SECTION 319 CLEARANCE OF VEGETATION FROM STRUCTURES
109 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION 401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS
110 SECTION 404 FIRE SAFETY AND EVACUATION PLANS
111 SECTION 405 EMERGENCY EVACUATION DRILLS
TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
112 SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
SECTION 407 HAZARD COMMUNICATION
SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS
117 PART III—BUILDING AND EQUIPMENT DESIGN FEATURES
CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS
118 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
119 SECTION 505 PREMISES IDENTIFICATION
SECTION 506 KEY BOXES
SECTION 507 FIRE PROTECTION WATER SUPPLIES
120 TABLE 507.3 MINIMUM FIRE FLOW REQUIREMENTS
SECTION 508 FIRE COMMAND CENTER
122 SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE
123 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
SECTION 603 FUEL-FIRED APPLIANCES
126 SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS
128 SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
129 SECTION 606 MECHANICAL REFRIGERATION
131 SECTION 607 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
132 SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS
TABLE 608.1 BATTERY REQUIREMENTS
133 SECTION 609 COMMERCIAL KITCHEN HOODS
134 TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY
SECTION 610 COMMERCIAL KITCHEN COOKING OIL STORAGE
SECTION 611 PEDESTRIAN WALKWAYS, PEDESTRIAN TUNNELS, AND MEZZANINES
135 CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION
136 SECTION 704 FLOOR OPENINGS AND SHAFTS
137 CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS
138 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
139 SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS
140 SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
143 SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
145 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
147 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
148 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
149 SECTION 902 DEFINITIONS
150 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
151 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
154 TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
157 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
160 SECTION 905 STANDPIPE SYSTEMS
163 SECTION 906 PORTABLE FIRE EXTINGUISHERS
TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
164 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa
165 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
175 TABLE 907.5.2.3.3 VISIBLE ALARMS
176 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
178 EQUATION 9-1
EQUATION 9-2
179 EQUATION 9-3
182 SECTION 910 SMOKE AND HEAT REMOVAL
183 EQUATION 9-4
184 TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
185 SECTION 911 EXPLOSION CONTROL
186 TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS
187 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
188 SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
190 TABLE 914.8.2 HANGAR FIRE SUPPRESSION REQUIREMENTS
193 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
194 SECTION 1003 GENERAL MEANS OF EGRESS
195 SECTION 1004 OCCUPANT LOAD
TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
196 SECTION 1005 MEANS OF EGRESS SIZING
197 SECTION 1006 MEANS OF EGRESS ILLUMINATION
SECTION 1007 ACCESSIBLE MEANS OF EGRESS
SECTION 1008 DOORS, GATES AND TURNSTILES
199 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
204 SECTION 1009 STAIRWAYS
209 SECTION 1010 RAMPS
210 SECTION 1011 EXIT SIGNS
211 SECTION 1012 HANDRAILS
212 SECTION 1013 GUARDS
214 SECTION 1014 EXIT ACCESS
215 [B] TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
[B] TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
216 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
[B] TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa
217 SECTION 1017 AISLES
SECTION 1018 CORRIDORS
218 [B] TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
[B] TABLE 1018.2 MINIMUM CORRIDOR WIDTH
219 SECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION
220 [B] TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
[B] TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
221 SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
223 SECTION 1023 EXIT PASSAGEWAYS
SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
225 SECTION 1025 HORIZONTAL EXITS
SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
226 SECTION 1027 EXIT DISCHARGE
227 SECTION 1028 ASSEMBLY
228 [B] TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
230 [B] TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
232 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
233 SECTION 1030 MAINTENANCE OF THE MEANS OF EGRESS
235 ICC 300 BLEACHERS, FOLDING AND TELESCOPIC SEATING, AND GRANDSTANDS
AMERICAN NATIONAL STANDARD
FOREWORD
237 CHAPTER 1 APPLICATION AND ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
SECTION 103 COMPLIANCE ALTERNATIVES
SECTION 104 CONVENTIONS
SECTION 105 INSPECTION
SECTION 106 REFERENCED DOCUMENTS
239 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINED TERMS
241 CHAPTER 3 CONSTRUCTION
SECTION 301 GENERAL
SECTION 302 PERMITTED MATERIALS
SECTION 303 STRUCTURAL DESIGN
TABLE 303.2 DESIGN LOADS
242 EQUATION 3-1
EQUATION 3-2
EQUATION 3-3
EQUATION 3-4
SECTION 304 INTERIOR INSTALLATIONS
SECTION 305 SPACES BENEATH SEATS
SECTION 306 CLEAR HEIGHT
SECTION 307 ROOF HEIGHT
SECTION 308 ELECTRICAL
SECTION 309 FIRE PROTECTION
243 SECTION 310 ACCESSIBILITY
SECTION 311 OPEN SPACES BENEATH FOOTBOARDS AND SEATBOARDS
245 CHAPTER 4 EGRESS
SECTION 401 GENERAL
SECTION 402 TRAVEL
SECTION 403 OCCUPANT LOAD
SECTION 404 GENERAL MEANS OF EGRESS
SECTION 405 AISLES
246 TABLE 404.5(1) WIDTH OF AISLES AND MEANS OF EGRESS FOR INDOOR SMOKE-PROTECTED ASSEMBLY SEATING
TABLE 404.5(2) WIDTH OF AISLES AND MEANS OF EGRESS FOR INDOOR NONSMOKE-PROTECTED ASSEMBLY SEATING
TABLE 404.5(3) WIDTH OF AISLES AND MEANS OF EGRESS FOR OUTDOOR SMOKE-PROTECTED ASSEMBLY SEATING
247 SECTION 406 AISLE STAIRS
SECTION 407 AISLE ACCESSWAYS
248 TABLE 407.5 SMOKE-PROTECTED AISLE ACCESSWAYS
249 SECTION 408 GUARDS
SECTION 409 HANDRAILS
251 CHAPTER 5 EXISTING BLEACHERS, FOLDING AND TELESCOPIC SEATING, AND GRANDSTANDS
253 CHAPTER 11 CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
SECTION 1101 GENERAL
SECTION 1102 DEFINITION
SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
254 TABLE 1103.4 VERTICAL OPENING PROTECTION REQUIRED
256 SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS
257 TABLE 1103.8 SMOKE ALARM REQUIREMENTS
259 TABLE 1104.9 REVOLVING DOOR SPEEDS
260 TABLE 1104.16 DIMENSIONS FOR EXISTING FIRE ESCAPE STAIRS
TABLE 1104.17.1 CORRIDOR FIRE-RESISTANCE RATING
261 TABLE 1104.17.4 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
262 TABLE 1104.22 MINIMUM AISLE AND AISLE ACCESSWAY WIDTHS
TABLE 1104.24 TWO EGRESS DOORS OR EXITS REQUIRED
263 SECTION 1105 REQUIREMENTS FOR OUTDOOR OPERATIONS
SECTION 1106 SEPARATION OF OCCUPANCIES AND HAZARDOUS AREAS
265 CHAPTERS 12 THROUGH 19 RESERVED
267 PART IV—SPECIAL OCCUPANCIES AND OPERATIONS
CHAPTER 20 AVIATION FACILITIES
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 AIRCRAFT MAINTENANCE
268 SECTION 2005 PORTABLE FIRE EXTINGUISHERS
SECTION 2006 AIRCRAFT FUELING
273 SECTION 2007 HELISTOPS AND HELIPORTS
275 CHAPTER 21 DRY CLEANING
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 CLASSIFICATIONS
SECTION 2104 GENERAL REQUIREMENTS
SECTION 2105 OPERATING REQUIREMENTS
276 EQUATION 21-1
SECTION 2106 SPOTTING AND PRETREATING
277 SECTION 2107 DRY CLEANING SYSTEMS
SECTION 2108 FIRE PROTECTION
279 CHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 2201 GENERAL
SECTION 2202 DEFINITION
SECTION 2203 PRECAUTIONS
SECTION 2204 EXPLOSION PROTECTION
TABLE 2204.1 EXPLOSION PROTECTION STANDARDS
281 CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 LOCATION OF DISPENSING DEVICES
SECTION 2304 DISPENSING OPERATIONS
282 SECTION 2305 OPERATIONAL REQUIREMENTS
283 SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
284 TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
288 SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
289 SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
290 TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
292 SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES
293 SECTION 2311 REPAIR GARAGES
297 CHAPTER 24 FLAMMABLE FINISHES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 PROTECTION OF OPERATIONS
299 SECTION 2404 SPRAY FINISHING
302 SECTION 2405 DIPPING OPERATIONS
304 SECTION 2406 POWDER COATING
SECTION 2407 ELECTROSTATIC APPARATUS
305 SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
306 SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS
307 CHAPTER 25 FRUIT AND CROP RIPENING
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 ETHYLENE GAS
SECTION 2504 SOURCES OF IGNITION
SECTION 2505 COMBUSTIBLE WASTE
SECTION 2506 ETHYLENE GENERATORS
SECTION 2507 WARNING SIGNS
309 CHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FIRE SAFETY REQUIREMENTS
311 CHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 2701 GENERAL
SECTION 2702 DEFINITIONS
SECTION 2703 GENERAL SAFETY PROVISIONS
315 SECTION 2704 STORAGE
316 TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
317 TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
SECTION 2705 USE AND HANDLING
318 TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
321 CHAPTER 28 LUMBER YARDS AND WOODWORKING FACILITIES
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 GENERAL REQUIREMENTS
SECTION 2804 FIRE PROTECTION
322 SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 2806 LOG STORAGE AREAS
SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES
323 SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS
325 CHAPTER 29 MANUFACTURE OF ORGANIC COATINGS
SECTION 2901 GENERAL
SECTION 2902 DEFINITION
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION
326 SECTION 2905 PROCESS STRUCTURES
SECTION 2906 PROCESS MILLS AND KETTLES
SECTION 2907 PROCESS PIPING
SECTION 2908 RAW MATERIALS IN PROCESS AREAS
327 SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS
329 CHAPTER 30 INDUSTRIAL OVENS
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
SECTION 3003 LOCATION
SECTION 3004 FUEL PIPING
SECTION 3005 INTERLOCKS
SECTION 3006 FIRE PROTECTION
SECTION 3007 OPERATION AND MAINTENANCE
331 CHAPTER 31 TENTS AND OTHER MEMBRANE STRUCTURES
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
332 TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
333 SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
337 CHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 3201 GENERAL
SECTION 3202 DEFINITIONS
SECTION 3203 COMMODITY CLASSIFICATION
339 SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS
340 FIGURE 3203.7.4 MIXED COMMODITIESa
341 SECTION 3205 HOUSEKEEPING AND MAINTENANCE
SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
342 TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
343 SECTION 3207 SOLID-PILED AND SHELF STORAGE
SECTION 3208 RACK STORAGE
344 TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 3209 AUTOMATED STORAGE
345 SECTION 3210 SPECIALTY STORAGE
347 CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 DEFINITIONS
SECTION 3303 TEMPORARY HEATING EQUIPMENT
SECTION 3304 PRECAUTIONS AGAINST FIRE
SECTION 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS
348 SECTION 3306 FLAMMABLE GASES
SECTION 3307 EXPLOSIVE MATERIALS
SECTION 3308 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 3309 FIRE REPORTING
SECTION 3310 ACCESS FOR FIRE FIGHTING
SECTION 3311 MEANS OF EGRESS
349 SECTION 3312 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3313 STANDPIPES
SECTION 3314 AUTOMATIC SPRINKLER SYSTEM
SECTION 3315 PORTABLE FIRE EXTINGUISHERS
SECTION 3316 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3317 SAFEGUARDING ROOFING OPERATIONS
351 CHAPTER 34 TIRE REBUILDING AND TIRE STORAGE
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 TIRE REBUILDING
SECTION 3404 PRECAUTIONS AGAINST FIRE
SECTION 3405 OUTDOOR STORAGE
352 SECTION 3406 FIRE DEPARTMENT ACCESS
SECTION 3407 FENCING
SECTION 3408 FIRE PROTECTION
SECTION 3409 INDOOR STORAGE ARRANGEMENT
353 CHAPTER 35 WELDING AND OTHER HOT WORK
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
SECTION 3504 FIRE SAFETY REQUIREMENTS
354 SECTION 3505 GAS WELDING AND CUTTING
355 SECTION 3506 ELECTRIC ARC HOT WORK
SECTION 3507 CALCIUM CARBIDE SYSTEMS
SECTION 3508 ACETYLENE GENERATORS
SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
357 CHAPTER 36 MARINAS
SECTION 3601 SCOPE
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL PRECAUTIONS
SECTION 3604 FIRE PROTECTION EQUIPMENT
SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES
359 CHAPTERS 37 THROUGH 49 RESERVED
361 PART V—HAZARDOUS MATERIALS
CHAPTER 50 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION 5001 GENERAL
363 SECTION 5002 DEFINITIONS
364 SECTION 5003 GENERAL REQUIREMENTS
366 TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
367 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
368 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
369 TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
370 TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA
371 TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREA
373 TABLE 5003.8.2 DETACHED BUILDING REQUIRED
374 TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
377 TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES—NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
378 SECTION 5004 STORAGE
379 TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
381 SECTION 5005 USE, DISPENSING AND HANDLING
383 TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
387 CHAPTER 51 AEROSOLS
SECTION 5101 GENERAL
SECTION 5102 DEFINITIONS
SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS
TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
388 TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
389 TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 5105 OUTSIDE STORAGE
TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
SECTION 5106 RETAIL DISPLAY
390 TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
391 TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
SECTION 5107 MANUFACTURING FACILITIES
393 CHAPTER 52 COMBUSTIBLE FIBERS
SECTION 5201 GENERAL
SECTION 5202 DEFINITIONS
SECTION 5203 GENERAL PRECAUTIONS
SECTION 5204 LOOSE FIBER STORAGE
394 SECTION 5205 BALED STORAGE
395 CHAPTER 53 COMPRESSED GASES
SECTION 5301 GENERAL
SECTION 5302 DEFINITIONS
SECTION 5303 GENERAL REQUIREMENTS
398 SECTION 5304 STORAGE OF COMPRESSED GASES
399 SECTION 5305 USE AND HANDLING OF COMPRESSED GASES
SECTION 5306 MEDICAL GAS SYSTEMS
400 SECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED
401 CHAPTER 54 CORROSIVE MATERIALS
SECTION 5401 GENERAL
SECTION 5402 DEFINITION
SECTION 5403 GENERAL REQUIREMENTS
SECTION 5404 STORAGE
SECTION 5405 USE
403 CHAPTER 55 CRYOGENIC FLUIDS
SECTION 5501 GENERAL
SECTION 5502 DEFINITIONS
SECTION 5503 GENERAL REQUIREMENTS
405 SECTION 5504 STORAGE
TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
406 TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 5505 USE AND HANDLING
409 CHAPTER 56 EXPLOSIVES AND FIREWORKS
SECTION 5601 GENERAL
411 TABLE 5601.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES
TABLE 5601.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVES
TABLE 5601.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVES
412 SECTION 5602 DEFINITIONS
SECTION 5603 RECORD KEEPING AND REPORTING
413 SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING
414 TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
415 TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
416 TABLE 5604.5.2(1)-continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
417 TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARD
TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4c
419 SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS
420 TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa
421 SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS
423 SECTION 5607 BLASTING
424 SECTION 5608 FIREWORKS DISPLAY
425 SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS Deleted
427 CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 5701 GENERAL
SECTION 5702 DEFINITIONS
428 SECTION 5703 GENERAL REQUIREMENTS
TABLE 5703.6.2 PIPING STANDARDS
429 TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
430 TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
432 SECTION 5704 STORAGE
443 TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES
444 TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
445 TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
446 TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS
447 TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
448 TABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS OR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
449 TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAY
450 TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESSa, b
451 TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
452 SECTION 5705 DISPENSING, USE, MIXING AND HANDLING
453 TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1)
456 TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREASa, b
458 SECTION 5706 SPECIAL OPERATIONS
469 CHAPTER 58 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 5801 GENERAL
SECTION 5802 DEFINITIONS
SECTION 5803 GENERAL REQUIREMENTS
470 SECTION 5804 STORAGE
SECTION 5805 USE
SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS
471 SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS
473 CHAPTER 59 FLAMMABLE SOLIDS
SECTION 5901 GENERAL
SECTION 5902 DEFINITIONS
SECTION 5903 GENERAL REQUIREMENTS
SECTION 5904 STORAGE
SECTION 5905 USE
SECTION 5906 MAGNESIUM
475 CHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 6001 GENERAL
SECTION 6002 DEFINITIONS
SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
476 SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
479 TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
480 SECTION 6005 OZONE GAS GENERATORS
483 CHAPTER 61 LIQUEFIED PETROLEUM GASES
SECTION 6101 NFPA STANDARD NO. 58 INCORPORATED
SECTION 6102 AMENDMENTS TO NFPA STANDARD NO. 58
485 CHAPTER 62 ORGANIC PEROXIDES
SECTION 6201 GENERAL
SECTION 6202 DEFINITION
SECTION 6203 GENERAL REQUIREMENTS
SECTION 6204 STORAGE
486 TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES
487 SECTION 6205 USE
489 CHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION 6301 GENERAL
SECTION 6302 DEFINITIONS
SECTION 6303 GENERAL REQUIREMENTS
490 SECTION 6304 STORAGE
TABLE 6304.1.2 OXIDIZER LIQUIDS AND SOLIDS—DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
TABLE 6304.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERSa
491 TABLE 6304.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDSa, b
TABLE 6304.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDSa, b
TABLE 6304.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.2.2 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa
492 SECTION 6305 USE
SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE
495 CHAPTER 64 PYROPHORIC MATERIALS
SECTION 6401 GENERAL
SECTION 6402 DEFINITION
SECTION 6403 GENERAL REQUIREMENTS
SECTION 6404 STORAGE
496 TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6405 USE
497 CHAPTER 65 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 6501 GENERAL
SECTION 6502 DEFINITIONS
SECTION 6503 GENERAL REQUIREMENTS
SECTION 6504 STORAGE AND HANDLING
499 CHAPTER 66 UNSTABLE (REACTIVE) MATERIALS
SECTION 6601 GENERAL
SECTION 6602 DEFINITION
SECTION 6603 GENERAL REQUIREMENTS
SECTION 6604 STORAGE
500 SECTION 6605 USE
501 CHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 6701 GENERAL
SECTION 6702 DEFINITION
SECTION 6703 GENERAL REQUIREMENTS
SECTION 6704 STORAGE
502 SECTION 6705 USE
503 CHAPTERS 68 THROUGH 79 RESERVED
505 PART VI—REFERENCED STANDARDS
CHAPTER 80 REFERENCED STANDARDS
AASHTO
AFSI
API
506 ASME
ASTM
507 BHMA
CA
CGA
508 CGR
CPSC
DOC
DOL
DOTn
509 DOTy
EN
EPA
FCC
510 ICC
ISO
511 NEMA
NFPA
513 UL
514 USC
515 CHAPTER 81 ADULT DAY CARE CENTERS, RESIDENTIAL HOSPICE FACILITIES AND SUPERVISED LIVING FACILITIES
SECTION 8101 GENERAL
SECTION 8102 ADULT DAY CARE CENTERS
SECTION 8103 RESIDENTIAL HOSPICE FACILITIES
SECTION 8104 SUPERVISED LIVING FACILITIES
517 PART VII—APPENDICES
APPENDIX A BOARD OF APPEALS
SECTION A101 GENERAL
519 APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
SECTION B104 FIRE-FLOW CALCULATION AREA
SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B106 REFERENCED STANDARDS
520 TABLE B105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS
521 APPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 LOCATION
SECTION C103 NUMBER OF FIRE HYDRANTS
SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION C105 DISTRIBUTION OF FIRE HYDRANTS
TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS
523 APPENDIX D FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
SECTION D103 MINIMUM SPECIFICATIONS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
524 FIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS
525 SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
D108 REFERENCED STANDARDS
527 APPENDIX E HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES
531 SECTION E103 EVALUATION OF HAZARDS
532 SECTION E104 REFERENCED STANDARDS
533 APPENDIX F HAZARD RANKING
SECTION F101 GENERAL
SECTION F102 REFERENCED STANDARDS
534 TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES
535 APPENDIX G CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL
536 TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS
537 APPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS
SECTION H101 HMMP
SECTION H102 HMIS
538 SECTION H103 EMERGENCY PLAN
SECTION H104 REFERENCED STANDARDS
539 FIGURE 1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
540 FIGURE 2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
541 FIGURE 3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C—FACILITY MAP
542 FIGURE 4 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS SUMMARY REPORT
543 FIGURE 5SECTION II — HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS INVENTORY REPORT
545 APPENDIX I FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS
546 SECTION I102 REFERENCED STANDARDS
547 APPENDIX J BUILDING INFORMATION SIGN
SECTION J101 GENERAL
FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN
549 SECTION J102 REFERENCED STANDARDS
551 APPENDIX K FIRES OR BARBECUES ON BALCONIES OR PATIOS
SECTION 1 OPEN FLAME AND FUEL STORAGE PROHIBITED
553 APPENDIX L EMERGENCY RESPONDER RADIO COVERAGE
L101 EMERGENCY RESPONDER RADIO COVERAGE IN EXISTING BUILDINGS
L102 EMERGECY RESPONDER RADIO COVERAGE IN NEW BUILDINGS
L103 PERMIT REQUIRED
L104 TECHNICAL REQUIREMENTS
554 L105 INSTALLATION REQUIREMENTS
L106 MAINTENANCE
557 INDEX
MN MinnesotaFireCode 2015
$45.83