Shopping Cart

No products in the cart.

MN MinnesotaMechFuelGasPlumbingCodes 2009

$54.17

Minnesota State Mechanical, Fuel Gas, and Plumbing Codes Chapters 1346 and 4715

Published By Publication Date Number of Pages
MN 2009 450
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2006 International Mechanical Code and 2006 International Fuel Gas Code®.

PDF Catalog

PDF Pages PDF Title
1 2009 MINNESOTA STATE MECHANICAL, FUEL GAS AND PLUMBING CODES, CHAPTERS 1346 AND 4715
2 COPYRIGHT
3 NOTE TO USERS
5 TABLE OF CONTENTS MINNESOTA RULES, CHAPTER 1300
7 MINNESOTA RULES, CHAPTER 1300
1300.0010 ADMINISTRATION
1300.0020 TITLE
1300.0030 PURPOSE AND APPLICATION
1300.0040 SCOPE
1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE
8 1300.0060 OPTIONAL ADMINISTRATION
1300.0070 DEFINITIONS
9 1300.0080 CODE ADOPTION AND AMENDMENTS
10 1300.0090 DEPARTMENT OF BUILDING SAFETY
1300.0100 [REPEALED, 19 SR 1340]
1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL
11 1300.0120 PERMITS
13 1300.0130 CONSTRUCTION DOCUMENTS
14 1300.0140 VIOLATIONS
1300.0150 VIOLATIONS, PENALTY
1300.0160 FEES
15 1300.0170 STOP WORK ORDER
1300.0180 UNSAFE BUILDINGS OR STRUCTURES
1300.0190 TEMPORARY STRUCTURES AND USES
16 1300.0200 [REPEALED, 19 SR 1340]
1300.0210 INSPECTIONS
17 1300.0220 CERTIFICATE OF OCCUPANCY
1300.0230 BOARD OF APPEALS
18 1300.0240 DISCLAIMER CLAUSE
1300.0250 SEVERABILITY
19 MINNESOTA MECHANICAL CODE
TABLE OF CONTENTS MINNESOTA MECHANICAL CODE
22 SYMBOLS AND NOTATIONS IN THE CODE
23 MINNESOTA RULES CHAPTER 1346 MINNESOTA MECHANICAL CODE
1346.0050 INCORPORATION BY REFERENCE
1346.0060 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES
25 CHAPTER 1 ADMINISTRATION
SECTION 101 SCOPE
SECTION 102 EXISTING INSTALLATIONS
SECTION 103 MAINTENANCE
SECTION 104 ADDITIONS, ALTERATIONS, RENOVATIONS, OR REPAIRS
SECTION 105 WORK EXEMPT FROM PERMIT
SECTION 106 REQUIRED INSPECTIONS
26 SECTION 107 INSPECTIONS AND TESTING
SECTION 108 AUTHORITY TO CONDEMN MECHANICAL SYSTEMS
27 SECTION 109 AUTHORITY TO ORDER DISCONNECTION OF ENERGY SOURCES
SECTION 110 CONNECTION AFTER ORDER TO DISCONNECT
29 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
41 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
42 SECTION 302 PROTECTION OF STRUCTURE
43 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
44 SECTION 305 PIPING SUPPORT
45 TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
47 SECTION 307 CONDENSATE DISPOSAL
SECTION 308 CLEARANCE REDUCTION
48 TABLE 308.6 CLEARANCE REDUCTION METHODS
49 [B] SECTION 309 TEMPERATURE CONTROL
[F] SECTION 310 EXPLOSION CONTROL
[F] SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
51 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
SECTION 402 NATURAL VENTILATION
52 SECTION 403 MECHANICAL VENTILATION
EQUATION 4-1
53 SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
55 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
57 TABLE 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN DWELLINGS
58 TABLE 501.3.2 MAKEUP AIR OPENING SIZING TABLE FOR NEW AND EXISTING DWELLINGS
59 TABLE 501.3.3(1) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN EXISTING DWELLINGS (Refer to Item 4 in Section 501.3.3 to determine applicability of this table)
60 TABLE 501.3.3(2) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN EXISTING DWELLINGS (Refer to Item 5 in Section 501.3.3 to determine applicability of this table)
61 TABLE 501.3.3(3) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST EQUIPMENT IN EXISTING DWELLINGS (Refer to Item 6 in Section 501.3.3 to determine applicability of this table)
62 SECTION 502 REQUIRED SYSTEMS
EQUATION 5-1
68 SECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST
69 SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
70 SECTION 507 COMMERCIAL KITCHEN HOODS
72 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
73 SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
74 TABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
75 SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
76 SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
77 EQUATION 5-2
EQUATION 5-3
78 EQUATION 5-4
79 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
81 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
SECTION 602 PLENUMS
82 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
83 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS
84 DUCT SEALING
SECTION 604 INSULATION
85 MINIMUM REQUIRED DUCT INSULATION (See notes for explanations)
SECTION 605 AIR FILTERS
86 SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
[B] SECTION 607 DUCT AND TRANSFER OPENINGS
87 TABLE 607.3.1 FIRE DAMPER RATING
91 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
SECTION 702 INDOOR AIR
SECTION 703 OUTDOOR AIR
92 SECTION 704 COMBINED USE OF INDOOR AND OUTDOOR AIR (CONDITION 1)
SECTION 705 COMBINED USE OF INDOOR AND OUTDOOR AIR (CONDITION 2)
SECTION 706 FORCED COMBUSTION AIR SUPPLY
93 SECTION 707 DIRECT CONNECTION
SECTION 708 COMBUSTION AIR DUCTS
SECTION 709 OPENING OBSTRUCTIONS
SECTION 710 OPENING LOCATION AND PROTECTION
95 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
96 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
97 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
98 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCESTO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
99 SECTION 805 FACTORY-BUILT CHIMNEYS
100 SECTION 806 METAL CHIMNEYS
101 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
102 SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
103 SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES
104 SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
105 SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
107 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SUBPART 1. DEPARTMENT OF LABOR AND INDUSTRY BOILERS
SUBPART 2. HIGH PRESSURE PIPING FOR BOILERS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
108 SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS
SECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
109 SECTION 1007 BOILER LOW-WATER CUTOFF
SECTION 1008 STEAM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
110 EQUATION 10-1
SECTION 1010 GAUGES
SECTION 1011 TESTS
111 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS
112 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
113 [F] TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
114 [F] TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
115 [F] TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
116 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
117 SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
EQUATION 11-1
118 EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 REFRIGERANT PIPING
119 SECTION 1108 FIELD TEST
120 [F] SECTION 1109 PERIODIC TESTING
121 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4—continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS
122 SECTION 1203 JOINTS AND CONNECTIONS
123 SECTION 1204 PIPE INSULATION
TABLE 1204.2 INSULATION THICKNESS FOR NOMINAL PIPE DIAMETERS
124 SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
SECTION 1207 TRANSFER FLUID
125 SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
127 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS
128 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
129 SECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
131 CHAPTER 14 SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION
SECTION 1403 HEAT TRANSFER FLUIDS
132 SECTION 1404 MATERIALS
133 CHAPTER 15 REFERENCED STANDARDS
ACCA
ANSI
ARI
ASHRAE
ASME
134 ASSE
ASTM
135 AWS
136 CSA
DOL
FS
ICC
137 IIAR
MSS
NAIMA
NFPA
138 SMACNA
UL
141 CHAPTER 16 INSTALLATION AND TESTING OF OIL OR LIQUID FUEL-FIRED EQUIPMENT
SECTION 1601 GENERAL
SECTION 1602 EQUIPMENT PLACEMENT
SECTION 1603 PILOT OPERATION
SECTION 1604 BURNER OPERATION
SECTION 1605 TEST METHODS
143 SECTION 1606 EQUIPMENT
145 APPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING
FIGURE A-2 ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
146 FIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE A-4 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS
147 FIGURE A-5 CHIMNEY CONNECTOR SYSTEMS
148 FIGURE A-5—continued CHIMNEY CONNECTOR SYSTEMS
149 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
151 INDEX
155 2009 MINNESOTA FUEL GAS CODE
2009 MINNESOTA FUEL GAS CODE PREFACE
157 TABLE OF CONTENTS MINNESOTA FUEL GAS CODE
159 MINNESOTA RULES CHAPTER 1346 MINNESOTA FUEL GAS CODE
1346.5050 INCORPORATION BY REFERENCE
161 CHAPTER 1 ADMINISTRATION
SECTION 101 (IFGC) GENERAL
SECTION 102 (IFGC) APPLICABILITY
162 SECTION 103 (IFGC) DEPARTMENT OF INSPECTION
SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL
163 SECTION 105 (IFGC) APPROVAL
SECTION 106 (IFGC) PERMITS
165 SECTION 107 (IFGC) INSPECTIONS AND TESTING
SECTION 108 (IFGC) VIOLATIONS
166 SECTION 109 (IFGC) MEANS OF APPEAL
169 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
177 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
178 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
179 SECTION 304 (IFGC) COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 3-1
EQUATION 3-2
180 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
181 FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
182 SECTION 305 (IFGC) INSTALLATION
183 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
184 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
185 TABLE 308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
186 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
187 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
189 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
TABLE 402.2 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
190 EQUATION 4-1
EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
191 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
192 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
193 TABLE 402.4(2)A PIPE SIZING TABLE FOR NATURAL GAS SCHEDULE 40 METALLIC PIPE
194 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
195 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
196 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
197 TABLE 402.4(6) SEMIRIGID COPPER TUBING
198 TABLE 402.4(7) SEMIRIGID COPPER TUBING
199 TABLE 402.4(8) SEMIRIGID COPPER TUBING
200 TABLE 402.4(9) SEMIRIGID COPPER TUBING
201 TABLE 402.4(10) SEMIRIGID COPPER TUBING
202 TABLE 402.4(11) SEMIRIGID COPPER TUBING
203 TABLE 402.4(12) SEMIRIGID COPPER TUBING
204 TABLE 402.4(13) CORRUGATED STAINLESS STEEL TUBING (CSST)
205 TABLE 402.4(14) CORRUGATED STAINLESS STEEL TUBING (CSST)
206 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
207 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
208 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
209 TABLE 402.4(18) POLYETHYLENE PLASTIC PIPE
210 TABLE 402.4(19) POLYETHYLENE PLASTIC PIPE
211 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
212 TABLE 402.4(21) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(22) POLYETHYLENE PLASTIC TUBING
213 TABLE 402.4(23) SCHEDULE 40 METALLIC PIPE
214 TABLE 402.4(24) SCHEDULE 40 METALLIC PIPE
215 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
216 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
217 TABLE 402.4(27) SEMIRIGID COPPER TUBING
218 TABLE 402.4(28) SEMIRIGID COPPER TUBING
219 TABLE 402.4(29) SEMIRIGID COPPER TUBING
220 TABLE 402.4(30) CORRUGATED STAINLESS STEEL TUBING (CSST)
221 TABLE 402.4(31) CORRUGATED STAINLESS STEEL TUBING (CSST)
222 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
223 TABLE 402.4(33) POLYETHYLENE PLASTIC PIPE
224 TABLE 402.4(34) POLYETHYLENE PLASTIC PIPE
225 TABLE 402.4(35) POLYETHYLENE PLASTIC TUBING
SECTION 403 (IFGS) PIPING MATERIALS
226 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
227 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
228 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
229 SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
230 TABLE 406.7.1 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS FOR SERVICING OR MODIFICATION
TABLE 406.7.2 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS BEFORE PLACING IN OPERATION
231 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
SECTION 409 (IFGC) SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
232 SECTION 410 (IFGC) FLOW CONTROLS
SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
233 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
234 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
236 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
239 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
240 SECTION 502 (IFGC) VENTS
241 SECTION 503 (IFGS) VENTING OF APPLIANCES
242 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
243 FIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT EQUIPMENT
245 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
FIGURE 503.6.10.1 PLAN VIEW OF PRACTICAL SEPARATION METHOD FOR MULTISTORY GAS VENTING
247 TABLE 503.7.7a CLEARANCES FOR CONNECTORS
248 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES AND COMMERCIAL AND INDUSTRIAL INCINERATORS VENT CONNECTOR SIZE
250 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
252 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
253 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
254 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
255 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
256 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
257 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
258 TABLE 504.2(3) MASONRY CHIMNEY
259 TABLE 504.2(3)—continued MASONRY CHIMNEY
260 TABLE 504.2(4) MASONRY CHIMNEY
261 TABLE 504.2(4)—continued MASONRY CHIMNEY
262 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
263 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
265 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
267 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
268 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
269 TABLE 504.3(1)—continued TYPE B DOUBLE-WALL VENT
270 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
271 TABLE 504.3(3) MASONRY CHIMNEY
272 TABLE 504.3(4) MASONRY CHIMNEY
273 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
274 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY—continued
275 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
277 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
278 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
279 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
280 SECTION 615 (IFGC) SAUNA HEATERS
281 SECTION 616 (IFGC) ENGINE AND GAS TURBINE- POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
SECTION 619 (IFGC) CONVERSION BURNERS
282 SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
283 SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING EQUIPMENT
SECTION 628 (IFGC) ILLUMINATING APPLIANCES
284 SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
285 SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
287 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
288 SECTION 704 (IFGC) PIPING, USE AND HANDLING
289 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
290 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
291 SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
293 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
294 ASME
ASTM
CGA
CSA
295 DOTn
ICC
MSS
NFPA
296 UL
297 CHAPTER 9 INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT
SECTION 901 (IFGC) GENERAL
SECTION 902 (IFGC) EQUIPMENT PLACEMENT
SECTION 903 (IFGC) PILOT OPERATION
SECTION 904 (IFGC) BURNER OPERATION
298 SECTION 905 (IFGC) METHOD OF TEST
299 SECTION 906 (IFGC) PRESSURE REGULATORS
SECTION 907 (IFGC) EQUIPMENT INFORMATION
301 CHAPTER 10 MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND INSTALLATION
SECTION 1000 GENERAL
TABLE 1002 DEMAND FACTORS FOR CALCULATING GAS PIPING SYSTEMS IN MANUFACTURED HOME PARKS AND COMMUNITIES
303 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
304 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
305 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
306 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
308 TABLE A.3.4 THOUSANDS OF Btu/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
309 TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
310 FIGURE A.6 (a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (LESS THAN 1.5 PSI)
FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above)
311 FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
312 FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM
FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
313 FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
315 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
316 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
317 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
318 FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
319 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
320 FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
322 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
323 FIGURE B-19
325 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
326 TABLE C-1 RECOMMENDED CAPACITIES FOR DOMESTIC KITCHEN EXHAUST HOODS
327 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
329 IFGC APPENDIX E (IFGC) WORKSHEET E-1
RESIDENTIAL COMBUSTION AIR CALCULATION METHOD
WORKSHEET E-1 RESIDENTIAL COMBUSTION AIR CALCULATION METHOD (For Furnace, Boiler, and/or Water Heater in the Same Space)
330 TABLE E-1 RESIDENTIAL COMBUSTION AIR REQUIRED VOLUME (Requ ired Interior Volume Based on Input Rating of Appliances)
331 TABLE E1 RESIDENTIAL COMBUSTION AIR REQUIRED VOLUME—Continued (Required Interior Volume Based on Input Rating of Appliances)
333 INDEX
337 2009 MINNESOTA PLUMBING CODE
TABLE OF CONTENTS MINNESOTA PLUMBING CODE
341 MINNESOTA RULES, CHAPTER 4715 2009 MINNESOTA PLUMBING CODE
4715.0100 DEFINITIONS
342 FIGURE – BAROMETRIC LOOP
FIGURE – BRANCH INTERVAL
343 FIGURE – COMMON VENTS
FIGURE – CONTINUOUS WASTE
344 FIGURE – COMMON VENT (BACK TO BACK WATER CLOSETS)
FIGURE – INDIVIDUAL VENTS (BACK TO BACK WATER CLOSETS)
345 FIGURE – FIXTURE BRANCH DRAIN/BUILDING DRAIN BRANCH
348 4715.0200 BASIC PLUMBING PRINCIPLES
349 4715.0300 GENERAL REGULATIONS OF PLUMBING CONSTRUCTION
4715.0310 USE OF PUBLIC SEWER AND WATER SYSTEMS REQUIRED
4715.0320 CONFORMANCE WITH CODE
4715.0330 ALTERNATE FIXTURES, APPURTENANCES, MATERIALS, AND METHODS
350 4715.0340 HEALTH AND SAFETY
4715.0400 QUALITY OF MATERIALS
4715.0410 IDENTIFICATION OF MATERIALS
4715.0420 STANDARDS FOR PLUMBING MATERIALS
351 TABLE STANDARDS FOR PLUMBING MATERIALS
352 TABLE STANDARDS FOR PLUMBING MATERIALS-continued
353 TABLE STANDARDS FOR PLUMBING MATERIALS-continued
354 4715.0500 WATER SUPPLY SYSTEMS
4715.0510 WATER SERVICE PIPE
4715.0520 WATER DISTRIBUTION PIPE
4715.0530 BUILDING SEWERS
355 4715.0540 STORM WATER AND YARD DRAINAGE (OUTSIDE FOUNDATION WALLS)
4715.0550 STORM WATER OR CLEAR WATER DRAINAGE (WITHIN BUILDINGS UNDERGROUND)
4715.0560 STORM WATER OR CLEAR WATER DRAINAGE (WITHIN BUILDINGS ABOVE GROUND)
4715.0570 SOIL AND WASTE PIPING UNDERGROUND OR EMBEDDED
4715.0580 SOIL AND WASTE PIPING ABOVE GROUND
4715.0590 VENT PIPING BELOW GROUND
356 4715.0600 VENT PIPING ABOVE GROUND
4715.0610 SPECIAL WASTES
4715.0620 SUBSOIL DRAINS
4715.0630 SPECIAL MATERIALS
4715.0640 FIXTURE MATERIALS
357 4715.0700 TIGHTNESS
4715.0710 ASBESTOS CEMENT SEWER PIPE JOINTS
4715.0720 BITUMINIZED FIBER DRAIN PIPE JOINT
4715.0730 BURNED LEAD JOINTS
4715.0740 CAULKED JOINTS
4715.0750 CEMENT MORTAR JOINTS
4715.0760 COLD JOINT COMPOUND, TAR BASE
4715.0770 FLARED JOINTS
4715.0780 GASKET TYPE JOINTS
4715.0790 HOT-POURED JOINTS
358 4715.0800 MECHANICAL JOINTS
4715.0805 PUSH-ON JOINTS
4715.0810 PLASTIC JOINTS
359 4715.0815 JOINTS IN CHEMICAL WASTE PIPE
4715.0820 SOLDERED OR BRAZED JOINTS
4715.0830 THREADED JOINTS — SCREWED JOINTS
4715.0840 WIPED JOINTS
4715.0850 USE OF JOINTS
360 4715.0860 SPECIAL JOINTS
4715.0870 FLANGED FIXTURE CONNECTIONS
4715.0880 PROHIBITED JOINTS AND CONNECTIONS
4715.0890 INCREASERS AND REDUCERS
361 4715.0900 FIXTURE TRAP REQUIREMENTS
FIGURE – 4715.0900 FIXTURE TRAP REQUIREMENTS
4715.0910 TRAPS DESCRIBED
4715.0920 TRAP PROTECTION
4715.0930 SIZES OF TRAPS
4715.0940 SLIP JOINTS AND UNIONS
4715.0950 TRAP SEALS
362 FIGURE – 4715.0950 TRAP SEALS
4715.0960 TRAPS PROHIBITED
4715.0970 TRAP CLEANOUTS
363 4715.1000 LOCATION
4715.1010 SIZE OF CLEANOUTS
4715.1020 CLEANOUT MATERIALS
4715.1030 CLEANOUTS TO BE ACCESSIBLE
364 4715.1100 INTERCEPTORS AND SEPARATORS REQUIRED
4715.1110 GREASE INTERCEPTORS FOR COMMERCIAL BUILDINGS
FIGURE – 4715.1110 GREASE INTERCEPTORS FOR COMMERCIAL BUILDINGS
4715.1115 EXTERIOR GREASE INTERCEPTORS
365 4715.1120 OIL AND FLAMMABLE LIQUIDS SEPARATOR
4715.1130 INTERCEPTORS AND SEPARATORS FOR SPECIFIC INSTALLATIONS
366 FIGURE – 4715.1120 OIL AND FLAMMABLE LIQUIDS SEPARATOR
4715.1140 VENTING OF INTERCEPTORS AND SEPARATORS
4715.1150 MAINTENANCE OF INTERCEPTORS AND SEPARATORS
4715.1160 BACKWATER VALVES
367 4715.1200 CONNECTIONS TO PLUMBING SYSTEM REQUIRED
4715.1210 REQUIRED MINIMUM NUMBER OF FIXTURES
4715.1220 INSTALLATION OF FIXTURES
4715.1230 AUTOMATIC CLOTHES WASHERS
4715.1240 BATHTUBS
4715.1250 DISHWASHING EQUIPMENT
4715.1260 DRINKING FOUNTAINS
368 FIGURE – 4715.1250 DISHWASHING EQUIPMENT
4715.1300 FLOOR DRAINS
369 FIGURE – 4715.1300 FLOOR DRAINS (Subp. 4)
4715.1305 ELEVATOR PIT DRAIN
4715.1310 FOOD-WASTE GRINDER UNITS
4715.1320 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
4715.1330 FLUSH TANKS
370 4715.1340 FLUSHOMETER VALVES
4715.1350 GARBAGE CAN WASHERS
4715.1360 LAUNDRY TRAYS
4715.1370 LAVATORIES
4715.1380 SHOWERS
4715.1390 SINKS
371 4715.1400 SPECIAL PLUMBING FIXTURES
4715.1410 URINALS
4715.1420 WATER CLOSETS
4715.1430 HANGERS AND SUPPORTS
4715.1440 PROTECTION OF PLASTIC PIPE
372 4715.1500 INDIRECT WASTE CONNECTIONS
4715.1510 INDIRECT WASTE PIPING
4715.1520 CONNECTIONS FROM WATER DISTRIBUTION SYSTEM
4715.1530 STERILIZERS
4715.1540 POTABLE CLEAR WATER WASTES
4715.1550 DRINKING FOUNTAINS
4715.1560 SWIMMING POOLS
4715.1570 METHOD OF PROVIDING AN AIR GAP
4715.1580 METHOD OF PROVIDING AN AIR BREAK
4715.1590 RECEPTORS OR SUMPS
373 FIGURE – 4715.1570 METHOD OF PROVIDING AN AIR GAP
FIGURE 4715.1580 METHOD OF PROVIDING AN AIR BREAK
374 4715.1600 CHEMICAL WASTES
4715.1610 STEAM AND HOT WATER WASTES
375 4715.1700 WATER REQUIRED
4715.1710 WATER SERVICE
4715.1720 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
4715.1730 SIZE OF FIXTURE BRANCH
TABLE OF MINIMUM SIZES OF FIXTURE WATER BRANCH LINES
376 4715.1740 WATER PRESSURE
4715.1750 WATER HAMMER
4715.1760 SUPPLY DEMAND
4715.1770 MINIMUM PRESSURES REQUIRED IN WATER DISTRIBUTION SYSTEM
TABLE OF MINIMUM FLOW PRESSURE AND FLOW RATES
377 4715.1800 WATER SUPPLY CONTROL VALVES
4715.1810 WATER PRESSURE BOOSTER SYSTEMS
378 TABLE – SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
TABLE – SIZE OF DRAIN PIPES FOR WATER TANKS
379 4715.1900 DESIGN, MAINTENANCE, AND INSTALLATION
4715.1910 IDENTIFICATION OF POTABLE AND NONPOTABLE WATER
4715.1911 TOXIC MATERIALS AND USED PIPE
4715.1912 USED WATER RETURN PROHIBITED
4715.1920 CROSS-CONNECTION CONTROL
4715.1930 [RENUMBERED 4715.1911]
4715.1940 POTABLE WATER CONNECTIONS TO HEATING OR COOLING SYSTEMS
4715.1941 HEAT EXCHANGERS
380 4715.1950 PROHIBITED CONNECTIONS TO FIXTURES AND EQUIPMENT
4715.1960 REFRIGERATING UNIT CONDENSERS AND COOLING JACKETS
4715.1970 [RENUMBERED 4715.1912]
381 4715.2000 WATER OUTLETS
4715.2010 MINIMUM REQUIRED AIR GAP
TABLE – MINIMUM AIR GAPS FOR PLUMBING FIXTURES
FIGURE – 4715.2010 MINIMUM REQUIRED AIR GAP
382 4715.2020 DEVICES OR ASSEMBLIES FOR THE PROTECTION OF THE POTABLE WATER SUPPLY
4715.2030 APPROVAL OF DEVICES OR ASSEMBLIES
383 4715.2100 BACKFLOW PREVENTERS
4715.2110 TYPES OF DEVICES REQUIRED WHERE AN AIR GAP CANNOT BE PROVIDED
TABLE 4715.2110 TYPES OF DEVICES REQUIRED WHERE AN AIR GAP CANNOT BE PROVIDED1
384 TABLE 4715.2110—continued TYPES OF DEVICES REQUIRED WHERE AN AIR GAP CANNOT BE PROVIDED
4715.2120 LOCATION OF BACKFLOW PREVENTERS
4715.2130 [REPEALED, 15 SR 76]
4715.2140 [REPEALED, 15 SR 76]
4715.2150 CONNECTIONS NOT SUBJECT TO BACK PRESSURE
TABLE – CROSS-CONNECTIONS WHERE PROTECTIVE DEVICES ARE REQUIRED AND CRITICAL LEVEL (C-L) SETTINGS FOR BACKFLOW PREVENTORS
4715.2160 CONNECTIONS SUBJECT TO BACK PRESSURE
385 4715.2161 INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS
4715.2162 DOUBLE CHECK-DOUBLE GATE VALVE ASSEMBLIES
4715.2163 CARBONATED BEVERAGE MACHINES
4715.2165 CHEMICAL/SOAP DISPENSING SYSTEMS
4715.2170 BAROMETRIC LOOP
4715.2180 HOT WATER SUPPLY SYSTEM
4715.2190 COMBINATION WATER AND SPACE HEATING EQUIPMENT
386 4715.2200 PRESSURE RELIEF VALVES AND TEMPERATURE RELIEF VALVES DEVICES REQUIRED
4715.2210 PRESSURE RELIEF VALVES
4715.2215 THERMAL EXPANSION CONTROL
4715.2220 HOT WATER STORAGE TANKS
4715.2230 TANKLESS AND INSTANTANEOUS TYPE HEATERS
4715.2240 ACCESS TO WATER HEATERS
4715.2250 DISINFECTION OF POTABLE WATER SYSTEM
387 4715.2260 [RENUMBERED 4715.2161]
4715.2270 [RENUMBERED 4715.2162]
4715.2280 WATER METER INSTALLATION
388 4715.2300 LOAD ON DRAINAGE PIPING
TABLE VALUES FOR INTERMITTENT FLOWS
TABLE OF FIXTURE UNITS VALUES
TABLE OF FIXTURE UNITS VALUES—Continued
389 4715.2310 SELECTING SIZE OF GRAVITY DRAINAGE PIPING
TABLE MAXIMUM LOADS FOR HORIZONTAL DRAINS IN FIXTURE UNITS
TABLE MAXIMUM LOADS FOR SOIL AND WASTE STACKS IN FIXTURE UNITS
4715.2320 MINIMUM SIZE OF SOIL AND WASTE STACKS
4715.2330 MINIMUM SIZE OF STACK VENT OR VENT STACK
4715.2340 PROVISION FOR FUTURE FIXTURES
4715.2350 MINIMUM SIZE OF UNDERGROUND DRAINAGE PIPING
4715.2360 SIZING OF OFFSETS ON DRAINAGE PIPING
390 FIGURE 4715.2330 MINIMUM SIZE OF STACK VENT OR VENT STACK
FIGURE 4715.2330 MINIMUM SIZE OF STACK VENT OR VENT STACK
391 FIGURE 4715.2360 SIZING OF OFFSETS ON DRAINAGE PIPING
4715.2370 FIXTURE CONNECTIONS TO AN OFFSET OF MORE THAN 45 DEGREES OR AT BASE OF STACK
392 4715.2400 PITCH ON HORIZONTAL DRAINAGE PIPING
TABLE SIZE OF PIPING AND MINIMUM SLOPE
4715.2410 CHANGE IN DIRECTION
FIGURE 4715.2410 CHANGE IN DIRECTION
4715.2420 PROHIBITED FITTINGS AND CONNECTIONS
4715.2430 DRAINS BELOW BUILDING SEWER
393 4715.2440 DESIGN OF SUMPS
FIGURE 4715.2440 DESIGN OF SUMPS
394 4715.2500 SELECTING SIZE OF VENT PIPING
4715.2510 PROTECTION OF TRAP SEALS
4715.2520 VENT STACKS AND STACK VENTS
FIGURE 4715.2520 VENT STACKS AND STACK VENTS
395 TABLE SIZE AND LENGTH OF VENT STACKS
TABLE SIZE AND LENGTH OF VENTS; INDIVIDUAL, BRANCH, CIRCUIT AND HEADER
FIGURE 4715.2520 VENT STACKS AND STACK VENTS
396 FIGURE 4715.2520 VENT STACKS AND STACK VENTS
FIGURE 4715.2520 VENT STACKS AND STACK VENTS
4715.2530 VENT TERMINALS
397 4715.2540 VENT GRADES AND CONNECTIONS
FIGURE 4715.2540 VENT GRADES AND CONNECTIONS
4715.2550 WET VENTING
4715.2560 STACK VENTING
398 FIGURE 4715.2550 WET VENTING
FIGURE 4715.2550 WET VENTING
4715.2570 INDIVIDUAL FIXTURE REVENTING REQUIRED
4715.2580 COMMON VENTS
399 FIGURE 4715.2560 STACK VENTING
FIGURE 4715.2580 COMMON VENTS
400 FIGURE 4715.2580 COMMON VENTS
401 4716.2600 CIRCUIT AND LOOP VENTING
FIGURE 4716.2600 CIRCUIT AND LOOP VENTING (SUBP.2)
402 FIGURE 4715.2600 CIRCUIT AND LOOP VENTING (SUBP.3)
403 4715.2610 FIXTURES BACK-TO-BACK
4715.2620 FIXTURE VENTS
TABLE DISTANCE OF FIXTURE TRAP FROM VENT
FIGURE 4715.2620 FIXTURE VENTS
FIGURE 4715.2620 FIXTURE VENTS (SUBP. 3)
404 4715.2630 VENTS FOR FIXTURE TRAP BELOW TRAP DIP
4715.2640 YOKE VENTS FOR STACKS OF MORE THAN FIVE BRANCH INTERVALS
FIGURE 4715.2640 YOKE VENT STACKS OF MORE THAN FIVE BRANCH INTERVALS
4715.2650 COMBINATION WASTE AND VENT SYSTEM
FIGURE 4715.2655 ISLAND FIXTURE VENTING
405 4715.2650 COMBINATION WASTE AND VENT SYSTEM
4715.2655 ISLAND FIXTURE VENTING
4715.2660 VENTING OF SUMPS AND SEWERS
406 4715.2700 STORM SEWER SYSTEMS
4715.2710 SIZE OF BUILDING STORM DRAINS AND LEADERS
TABLE HORIZONTAL STORM DRAINS
TABLE SIZE OF VERTICAL LEADERS
FIGURE 4715.2710 SIZE OF BUILDING STORM DRAINS AND LEADERS
4715.2720 SUBSOIL DRAINS
4715.2730 BUILDING SUBDRAINS
407 4715.2740 TRAPS ON STORM DRAINS AND LEADERS
4715.2750 CONDUCTORS AND CONNECTIONS
4715.2760 ROOF AND DECK DRAINS
4715.2770 PROVISIONS FOR EXPANSION
4715.2780 CONTROL FLOW STORM WATER DRAINAGE FOR DEAD LEVEL ROOFS
TABLE SIZE OF VERTICAL LEADERS
TABLE SIZE OF HORIZONTAL STORM DRAINS
408 4715.2800 INSPECTIONS
4715.2810 NOTIFICATIONS
4715.2820 METHOD OF TESTING
409 FIGURE 4715.2820 METHOD OF TESTING
4715.2830 COVERING OF WORK
4715.2840 DEFECTIVE WORK
4715.2850 AIR TEST OF DEFECTIVE PLUMBING
4715.2860 MAINTENANCE
410 4715.2870 DISINFECTION OF WATER PIPING
4715.2880 BUILDING SEWER
4715.2890 CERTIFICATE OF APPROVAL
411 4715.3130 PLANS AND SPECIFICATIONS
4715.3500 GENERAL
4715.3600 TOTAL DAILY WATER REQUIREMENTS.
TABLE DESIGN CRITERIA FOR DAILY WATER REQUIREMENTSBASED ON BUILDING OCCUPANCY
TABLE DESIGN CRITERIA FOR DAILY WATER REQUIREMENTS BASEDON BUILDING OCCUPANCY—CONTINUED
412 TABLE DAILY WATER REQUIREMENTS FOR COMMON FARM ANIMALS
4715.3700 DETERMINATION OF PEAK DEMAND
TABLE SUPPLY FIXTURE UNIT VALUES FOR VARIOUS PLUMBING FIXTURES
413 TABLE SUPPLY DEMAND FOR VARIOUS LOADSIN SUPPLY FIXTURE UNITS
FIGURE GRAPH OF SUPPLY DEMAND FOR VARIOUS LOADS IN SUPPLY FIXTURE UNITS
TABLE SUBP. 6 EXAMPLE TABULATION
414 TABLE SUBP. 7 EXAMPLE TABULATION
415 TABLE LOSS OF PRESSURE THROUGH DISK-TYPE METERS(pounds per square inch)
416 FIGURE GRAPH OF LOSS OF PRESSURE THROUGH DISK-TYPE METERS IN POUNDS PER SQUARE INCH
TABLE ALLOWANCE IN EQUIVALENT LENGTH OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS
TABLE LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH
417 TABLE PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF FAIRLY SMOOTH PIPE
418 FIGURE GRAPH OF PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF FAIRLY SMOOTH PIPE
419 TABLE PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF FAIRLY ROUGH PIPE
420 FIGURE GRAPH OF PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF FAIRLY ROUGH PIPE
421 TABLE PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF ROUGH PIPE
422 FIGURE PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF ROUGH PIPE
423 TABLE PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF COPPER PIPE
424 TABLE PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF COPPER PIPE—continued
425 FIGURE GRAPH OF PRESSURE LOSS OF WATER IN POUNDS PER SQUARE INCH PER 100 FEET OF COPPER PIPE
426 FIGURE ILLUSTRATION
427 TABLE RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
428 4715.3800 RECOMMENDED GUIDE FOR SIZING WATER SUPPLY SYSTEM
FIGURE 4715.3800 RECOMMENDED GUIDE FOR SIZING WATER SUPPLY SYSTEM (Water Closet Flushometers)
429 TABLE EQUIVALENT FIXTURE UNITS, INCLUDING COMBINED HOT AND COLD WATER DEMAND
430 TABLE FIXTURE UNIT TABLE FOR DETERMINING WATER PIPE AND METER SIZES FOR WATER SUPPLY SYSTEMS
431 FIGURE EXAMPLE OF CODE WATER SIZING USING SUBPART. 9
FIGURE EXAMPLE OF HOT WATER SIZING USING SUBPART. 9
432 4715.3900 [REPEALED, 15 SR 76]
4715.4000 [REPEALED, 15 SR 76]
4715.4100 USEFUL INFORMATION
TABLE PRESSURE AND HEAD EQUIVALENTS
433 TABLE DECIMAL EQUIVALENTS OF COMMON FRACTIONS IN INCHES
TABLE DECIMAL EQUIVALENTS OF INCHES IN FEET
FIGURE GEOMETRIC CALCULATIONS
434 TABLE DIAMETER, AREA, CIRCUMFERENCE AND VOLUME
FIGURE ILLUSTRATION OF MEASUREMENTS
435 TABLE PIPE FITTING ANGLE CALCULATIONS
436 4715.5000 SCOPE AND APPLICABILITY
4715.5100 DEFINITIONS
4715.5200 CONNECTION WITH WATER DISTRIBUTION SYSTEM
4715.5300 EQUIPMENT DRAIN
4715.5400 LOCATION
4715.5500 REGENERATION SANITATION PROCEDURES
TABLE MINIMUM CHLORINE RESIDUAL AND TIME COMBINATION
437 4715.5600 [REPEALED, L 2007 c 140 art 13 s 3]
4715.5700 EQUIPMENT AND MATERIALS USED IN INSTALLATIONS
4715.5800 LICENSING
4715.5900 [REPEALED, L 2007 c 140 art 13 s 3]
4715.6000 RENEWAL
439 TABLE OF CONTENTS MISCELLANEOUS MINNESOTA STATUTES RELATED TO PLUMBING
441 MISCELLANEOUS MINNESOTA STATUTES RELATED TO PLUMBING
326B.41 PURPOSE
326B.42 DEFINITIONS
326B.43 PLUMBING STANDARDS; RULES; AGREEMENT WITH MUNICIPALITY; EXEMPTION
443 326B.435 PLUMBING BOARD
446 326B.439B AN ON LEAD IN PLUMBING
326B.44 LOCAL REGULATIONS
326B.45 VIOLATIONS TO BE REPORTED TO COMMISSIONER
326B.46 LICENSING, BOND AND INSURANCE
447 326B.47 PLUMBER’S APPRENTICES
326B.475 RESTRICTED PLUMBER LICENSE
448 326B.48 RECIPROCITY WITH OTHER STATES
326B.49 APPLICATIONS, FEES
449 TABLE INSPECTION FEES
MN MinnesotaMechFuelGasPlumbingCodes 2009
$54.17