Shopping Cart

No products in the cart.

MN MinnesotaResidentialCode 2015

$50.92

Minnesota Residential Code

Published By Publication Date Number of Pages
MN 2015 595
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a soft cover fully integrated custom Minnesota code based on the 2012 International Residential Code® (excluding Chapters 11 thru 43). This code also includes Minnesota chapters 1300 Administration, 1303 Special Provisions and Radon, and 1322 Energy Effective dates: Minnesota Residential Code – January 24, 2015 Chapter 1303 Special Provisions and Radon, Chapter 1322 Energy – February 14, 2015

PDF Catalog

PDF Pages PDF Title
1 2015 MINNESOTA RESIDENTIAL CODE
2 2015 MINNESOTA RESIDENTIAL CODE TITLE PAGE
3 COPYRIGHT
4 MINNESOTA DEPARTMENT OF LABOR & INDUSTRY
5 IMPORTANT DISCLAIMER
6 PREFACE
10 EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE
20 TABLE OF CONTENTS
24 CHAPTER 1 SCOPE AND ADMINISTRATION
26 2015 MINNESOTA BUILDING CODE ADMINISTRATION
1300.0010 ADMINISTRATION
1300.0020 TITLE
1300.0030 PURPOSE AND APPLICATION
1300.0040 SCOPE
27 1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE
1300.0060 OPTIONAL ADMINISTRATION
1300.0070 DEFINITIONS
28 1300.0080 CODE ADOPTION AND AMENDMENTS
1300.0090 DEPARTMENT OF BUILDING SAFETY
1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL
30 1300.0120 PERMITS
32 1300.0130 CONSTRUCTION DOCUMENTS
33 1300.0140 VIOLATIONS
1300.0150 VIOLATIONS, PENALTY
1300.0160 FEES
34 1300.0170 STOP WORK ORDER
1300.0180 UNSAFE BUILDINGS OR STRUCTURES
35 1300.0190 TEMPORARY STRUCTURES AND USES
1300.0210 INSPECTIONS
36 1300.0215 PLUMBING
1300.0220 CERTIFICATE OF OCCUPANCY
37 1300.0225 MAINTENANCE
1300.0230 BOARD OF APPEALS
38 1300.0240 DISCLAIMER CLAUSE
1300.0250 SEVERABILITY
40 2015 MINNESOTA PROVISIONS TO THE MINNESOTA STATE BUILDING CODE (INCLUDING RADON)
1303.1000 TITLE
1303.1100 PURPOSE
1303.1200 RESTROOM FACILITIES IN PUBLIC ACCOMMODATIONS
1303.1300 SPACE FOR COMMUTER VANS
1303.1400 AUTOMATIC GARAGE DOOR OPENING SYSTEMS
1303.1500 RECYCLING SPACE
TABLE 1-A MINIMUM RECYCLING SPACE REQUIREMENTS
41 TABLE 1-A MINIMUM RECYCLING SPACE REQUIREMENTS—continued
1303.1600 FOOTING DEPTH FOR FROST PROTECTION
1303.1700 GROUND SNOW LOAD
1303.1800 (REPEALED)
1303.1900 (REPEALED)
1303.2000 EXTERIOR WOOD DECKS, PATIOS, AND BALCONIES
42 1303.2100 BLEACHER SAFETY
1303.2200 SIMPLIFIED WIND LOADS
TABLE P alt
1303.2300 (REPEALED)
1303.2305 (REPEALED)
1303.2310 (REPEALED)
1303.2320 (REPEALED)
1303.2330 (REPEALED)
1303.2400 PURPOSE AND SCOPE
43 1303.2401 DEFINITIONS
1303.2402 REQUIREMENTS FOR PASSIVE RADON CONTROL SYSTEMS
44 1303.2403 REQUIREMENTS FOR ACTIVE RADON CONTROL SYSTEMS
46 2015 MINNESOTA RESIDENTIAL ENERGY CODE
1322.0010 ADOPTION OF INTERNATIONAL ENERGY CONSERVATION CODE (IECC) BY REFERENCE
1322.0015 ADMINISTRATION AND PURPOSE
1322.0030 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES
1322.0040 ADMINISTRATIVE PROCEDURE CRITERIA
1322.0100 ADMINISTRATION FOR RESIDENTIAL ENERGY
47 1322.0103 CONSTRUCTION DOCUMENTS
48 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
50 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
51 FIGURE R301.1 CLIMATE ZONES
52 TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HU
53 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
54 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
55 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
56 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
57 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
58 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
59 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMIDDESIGNATIONS BY STATE, COUNTY AND TERRITORY
60 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
61 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMIDDESIGNATIONS BY STATE, COUNTY AND TERRITORY
62 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
63 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
64 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
65 SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
66 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
69 TABLE R402.1.3 EQUIVALENT U-FACTORSa
70 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
71 SECTION R403 SYSTEMS
72 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION
73 TABLE R403.2.1 MINIMUM REQUIRED DUCT AND PLENUM INSULATION FOR DWELLING UNITS
TABLE R403.4.2 MAXIMUM RUN LENGTH (feet)a
74 TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY
TABLE R403.5.2 NUMBER OF BEDROOMS
76 TABLE R403.5.17 CLIMATIC DATA DESIGN CONDITIONS
77 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
79 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
80 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
81 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
82 CHAPTER 5 [RE] REFERENCED STANDARDS
AAMA
ACCA
ASHRAE
ASTM
CSA
83 HVI
ICC
NFRC
US-FTC
WDMA
84 MINNESOTA RULES, CHAPTER 1309
1309.0010 ADOPTION OF INTERNATIONAL RESIDENTIAL CODE (IRC) BY REFERENCE
1309.0020 REFERENCES TO OTHER ICC CODES
85 1309.0030 ADMINISTRATIVE PROCEDURE CRITERIA
1309.0100 CHAPTER 1, ADMINISTRATION
86 CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
102 CHAPTER 3 BUILDING PLANNING
SECTION R300 CLASSIFICATION
TABLE R300.1 OCCUPANCY CLASSIFICATIONS
SECTION R301 DESIGN CRITERIA
103 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
104 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf)
105 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
FIGURE R301.2(1) ISOLINES OF THE 971/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F)
106 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES—SITE CLASS D
107 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
108 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
109 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
110 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
111 FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETEa
112 FIGURE R301.2(4)A BASIC WIND SPEEDS
113 FIGURE R301.2(4)B REGIONS WHERE WIND DESIGN IS REQUIRED
114 FIGURE R301.2(4)C WIND-BORNE DEBRIS REGIONS
115 FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP
116 FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa
TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa
118 TABLE R301.2.1.5.1 BASIC WIND MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT
FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
119 FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION
TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
120 TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa
122 TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
123 TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSb, c
SECTION R302 FIRE-RESISTANT CONSTRUCTION
TABLE R302.1(1) EXTERIOR WALLS
124 TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS WITH FIRE SPRINK
126 TABLE R302.6 DWELLING/GARAGE SEPARATION
128 SECTION R303 LIGHT, VENTILATION AND HEATING
129 SECTION R304 MINIMUM ROOM AREAS
SECTION R305 CEILING HEIGHT
130 SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
131 TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
133 SECTION R309 GARAGES AND CARPORTS
SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
134 SECTION R311 MEANS OF EGRESS
137 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS
138 SECTION R314 SMOKE ALARMS
139 SECTION R315 CARBON MONOXIDE ALARMS
SECTION R316 FOAM PLASTIC
141 SECTION R317 PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY
142 SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES
143 SECTION R319 SITE ADDRESS
SECTION R320 ACCESSIBILITY (DELETED)
SECTION R321 ELEVATORS AND PLATFORM LIFTS (DELETED)
SECTION R322 FLOOD-RESISTANT CONSTRUCTION (DELETED)
SECTION R323 STORM SHELTERS
144 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
SECTION R402 MATERIALS
145 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
146 FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS
147 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
148 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
149 TABLE R403.1 MINIMUM WIDTH OF CONCRETE, PRECAST OR MASONRY FOOTINGS (inches)a
FIGURE R403.1.3.2 DOWELS FOR SLABS-ON-GROUND WITH TURNED-DOWN FOOTINGS
151 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
153 FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST PROTECTED FOOTINGS IN HEATED BUILDINGS
TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
154 FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
155 TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
156 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
157 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
158 TABLE R403.3(2)—continuedAIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
159 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
160 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
161 FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (inches)
162 FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
SECTION R404 FOUNDATION AND RETAINING WALLS
163 TABLE R404.1(1) MAXIMUM ANCHOR BOLT AND BLOCKING SPACING FOR SUPPORTED FOUNDATION WALL
TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS
164 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHESa, c
165 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHESa, c
166 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHESa, c
167 TABLE R404.1.1(5) CANTILEVERED CONCRETE AND MASONRY FOUNDATION WALLS
168 TABLE R404.1.1(6) CANTILEVERED CONCRETE AND MASONRY FOUNDATION WALLS
169 TABLE R404.1.1(7) CANTILEVERED CONCRETE AND MASONRY FOUNDATION WALLS
171 TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLSa, b
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
172 TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLS
173 TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
174 TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS
175 TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS
176 TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLS
177 TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLS
178 TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL
182 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
184 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
185 SECTION R405 FOUNDATION DRAINAGE
TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
186 SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING
SECTION R407 COLUMNS
187 SECTION R408 UNDER-FLOOR SPACE
188 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
189 FIGURE R502.2 FLOOR CONSTRUCTION
190 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
191 TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
192 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
193 TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
194 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY
196 TABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
197 TABLE R502.5(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R502.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
198 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
199 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
200 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND)
201 SECTION R505 STEEL FLOOR FRAMING
TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES
202 TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
FIGURE R505.2(1) C-SHAPED SECTION
FIGURE R505.1.2 IN-LINE FRAMING
203 FIGURE R505.2(2) TRACK SECTION
TABLE R505.2.4 SCREW SUBSTITUTION FACTOR
204 FIGURE R505.2.5.1 FLOOR JOIST WEB HOLES
FIGURE R505.2.5.3 WEB HOLE PATCH
205 TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS
FIGURE 505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION
206 TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
207 FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION
208 FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
209 FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
210 FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
211 TABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE SPANSa, b, c, d 33 ksi STEEL
212 TABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b, c, d, e, f 33 ksi STEEL
213 TABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b, c, d, e, f 50 ksi STEEL
214 FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP)
215 FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
216 FIGURE R505.3.4(2) BEARING STIFFENER
TABLE R505.3.4(1) CLIP ANGLE BEARING STIFFENERS (20 psf equivalent snow load)
217 TABLE R505.3.4(2) CLIP ANGLE BEARING STIFFENERS (30 psf equivalent snow load)
TABLE R505.3.4(3) CLIP ANGLE BEARING STIFFENERS (50 psf equivalent snow load)
218 TABLE R505.3.4(4) CLIP ANGLE BEARING STIFFENERS (70 psf equivalent snow load)
FIGURE R505.3.7 TRACK SPLICE
219 FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION: 6-FOOT FLOOR OPENING
SECTION R506 CONCRETE FLOORS (ON GROUND)
220 FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING
FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
221 FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
SECTION R507 DECKS
222 TABLE R507.2 FASTENER SPACING FOR A SOUTHERN PINE OR HEM-FIR DECK LEDGER AND A 2-INCH-NOMINAL SOLID-SAWN SPRUCE-PINE-FIR BAND JOISTc, f, g (Deck live load = 40 psf, deck dead load = 10 psf)
TABLE 507.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS
FIGURE R507.2.1(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS
223 FIGURE R507.2.1(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS
FIGURE 507.2.3 DECK ATTACHMENT FOR LATERAL LOADS
224 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
225 TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
226 TABLE R602.3(1)—continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
227 TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
228 TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS
229 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
230 FIGURE R602.3(2) FRAMING DETAILS
231 TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 90 MPH OR LESS Where conditions are not within the parameters of footnotes b, c, d, e, f, g, h, and i, design is required.
232 TABLE R602.3.1—continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 90 MPH OR LESS
233 TABLE R602.3.1—continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2
235 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
236 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
237 TABLE R602.7.1 SPANS FOR MINIMUM No.2 GRADE SINGLE HEADER
238 FIGURE R602.7.1(1) SINGLE MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE R602.7.1(2) ALTERNATIVE SINGLE MEMBER HEADER WITHOUT CRIPPLE
239 TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERS
FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
240 FIGURE R602.10.1.1 BRACED WALL LINES
TABLE R602.10.1.3 BRACED WALL LINE SPACING
241 FIGURE R602.10.1.4 ANGLED WALLS
242 FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS
243 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
244 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
245 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
246 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
247 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
248 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
249 TABLE R602.10.4 BRACING METHODS
250 TABLE R602.10.4—continued BRACING METHODS
252 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
253 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
254 FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL
FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS
255 FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
256 FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
257 TABLE R602.10.6.4 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHOD PFH, PFG AND CS-PF BRACED WALL PANELS
258 TABLE R602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS
259 FIGURE R602.10.6.5 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2
260 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
261 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
262 FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
263 FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
FIGURE R602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
264 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
265 FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION
266 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
267 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
268 FIGURE R602.12.5 BRACING UNIT DISTRIBUTION
SECTION R603 STEEL WALL FRAMING
269 FIGURE R603.1.2 IN-LINE FRAMING
FIGURE R603.2(1) C-SHAPED SECTION
FIGURE R603.2(2) TRACK SECTION
270 TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES
TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
TABLE R603.2.4 SCREW SUBSTITUTION FACTOR
271 FIGURE R603.2.5.1 WEB HOLES
FIGURE R603.2.5.3 STUD WEB HOLE PATCH
272 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS
TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS
273 TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTS
FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
274 FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
275 TABLE R603.3.2(1) WALL FASTENING SCHEDULE
TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL
276 TABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 50 KSI STEEL
277 TABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL
278 TABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 50 KSI STEEL
279 TABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL
280 TABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL
281 TABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL
282 TABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL
283 TABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL
284 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL
285 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL
286 TABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL
287 TABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL
288 TABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL
289 TABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL
290 TABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL
291 TABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL
292 TABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL
293 TABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL
294 TABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL
295 TABLE R603.3.2(22) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL
296 TABLE R603.3.2(23) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL
297 TABLE R603.3.2(24) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL
298 TABLE R603.3.2(25) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL
299 TABLE R603.3.2(26) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL
300 TABLE R603.3.2(27) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL
301 TABLE R603.3.2(28) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL
302 TABLE R603.3.2(29) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL
303 TABLE R603.3.2(30) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL
304 TABLE R603.3.2(31) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL
305 TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa, b, c 33 KSI STEEL
306 TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa, b, c 50 KSI STEEL
307 TABLE R603.3.2.1(3) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa, b, c 33 KSI STEEL
308 TABLE R603.3.2.1(4) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa, b, c 50 KSI STEEL
309 FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
310 FIGURE R603.3.5 TRACK SPLICE
FIGURE R603.4 CORNER FRAMING
311 FIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(2) BACK-TO-BACK HEADER
312 TABLE R603.6(1) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a, b
313 TABLE R603.6(2) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a, b
314 TABLE R603.6(3) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a, b
315 TABLE R603.6(4) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a, b
316 TABLE R603.6(5) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b
317 TABLE R603.6(6) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b
318 TABLE R603.6(7) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b
319 TABLE R603.6(8) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b
320 TABLE R603.6(9) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b
321 TABLE R603.6(10) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a, b
322 TABLE R603.6(11) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b
323 TABLE R603.6(12) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a,b
324 TABLE R603.6(13) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a,b
325 TABLE R603.6(14) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a,b
326 TABLE R603.6(15) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a, b
327 TABLE R603.6(16) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a, b
328 TABLE R603.6(17) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b
329 TABLE R603.6(18) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b
330 TABLE R603.6(19) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b
331 TABLE R603.6(20) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b
332 TABLE R603.6(21) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b
333 TABLE R603.6(22) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a, b
334 TABLE R603.6(23) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b
335 TABLE R603.6(24) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a, b
336 FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
337 TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTSa
FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
338 TABLE R603.8 HEAD AND SILL TRACK SPAN Fy = 33 KSI
FIGURE R603.9.2 CORNER STUD HOLD-DOWN DETAIL
339 TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa, b
TABLE R603.9.2(2) FULL HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
340 SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
SECTION R606 GENERAL MASONRY CONSTRUCTION
341 TABLE R606.5 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
342 TABLE R606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
343 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
344 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
345 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1, OR D2
346 TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
347 TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
348 TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.15.1 MINIMUM CORROSION PROTECTION
SECTION R607 UNIT MASONRY
349 TABLE R607.1 MORTAR PROPORTIONSa, b
SECTION R608 MULTIPLE-WYTHE MASONRY
350 SECTION R609 GROUTED MASONRY
351 TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
352 SECTION R610 GLASS UNIT MASONRY
353 FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
SECTION R611 EXTERIOR CONCRETE WALL CONSTRUCTION
354 TABLE R611.3 DIMENSIONAL REQUIREMENTS FOR WALLSa, b
355 FIGURE R611.3(1) FLAT WALL SYSTEM
FIGURE R611.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE R611.3(3) SCREEN-GRID WALL SYSTEM
357 TABLE R611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
FIGURE R611.5.4(1) LAP SPLIC
358 FIGURE R611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
FIGURE R611.5.4(3) STANDARD HOOKS
359 TABLE R611.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND/OR ALTERNATIVE GRADE OF STEELa, b, c
360 FIGURE R611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE
FIGURE R611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY
361 FIGURE R611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING
362 TABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLSa, b, c, d, e
363 TABLE R611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS
364 TABLE R611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLSa, b, c, d, e
365 TABLE R611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l
366 EQUATION R6-1
EQUATION R6-2
367 TABLE R611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
368 TABLE R611.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
369 TABLE R611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
370 TABLE R611.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
371 TABLE R611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
372 TABLE R611.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
373 TABLE R611.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
TABLE R611.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEETa, b
374 TABLE R611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLSa, c
375 FIGURE R611.7(1) MINIMUM SOLID WALL LENGTH
377 FIGURE R611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
378 FIGURE R611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
379 FIGURE R611.8(1) REINFORCEMENT OF OPENINGS
380 FIGURE R611.8(2) LINTEL FOR FLAT WALLS
FIGURE R611.8(3) LINTELS FOR WAFFLE-GRID WALLS
381 FIGURE R611.8(4) LINTELS FOR SCREEN-GRID WALLS
382 TABLE R611.8(1) LINTEL DESIGN LOADING CONDITIONSa, b, d
383 TABLE R611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
384 TABLE R611.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEE
385 TABLE R611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
386 TABLE R611.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
387 TABLE R611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
388 TABLE R611.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
389 TABLE R611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
390 TABLE R611.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
391 TABLE R611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
392 TABLE R611.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
393 TABLE R611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
394 TABLE R611.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
395 TABLE R611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
396 TABLE R611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h
397 TABLE R611.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h
TABLE R611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSc, d, e, f, g
399 FIGURE R611.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
400 TABLE R611.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c
401 FIGURE R611.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL
402 TABLE R611.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b
403 FIGURE R611.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR
404 TABLE R611.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
405 FIGURE R611.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL
406 TABLE R611.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
407 FIGURE R611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
408 TABLE R611.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d
409 FIGURE R611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
410 TABLE R611.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b, c, d
411 FIGURE R611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR
412 TABLE R611.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
413 FIGURE R611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
414 TABLE R611.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
415 FIGURE R611.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
416 TABLE R611.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
417 FIGURE R611.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PARALLEL
418 TABLE R611.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
419 FIGURE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
420 TABLE R611.9(11) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
421 FIGURE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
422 TABLE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
423 SECTION R612 EXTERIOR WINDOWS AND DOORS
424 FIGURE R612.7.2(1) THROUGH THE FRAME
FIGURE R612.7.2(2) FRAME CLIP
FIGURE R612.7.2(3) THROUGH THE FRAME
FIGURE R612.7.2(4) FRAME CLIP
425 FIGURE R612.7.2(5) THROUGH THE FLANGE
FIGURE R612.7.2(6) THROUGH THE FLANGE
FIGURE R612.7.2(7) FRAME CLIP
FIGURE R612.7.2(8) THROUGH THE FLANGE
426 SECTION R613 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
TABLE R613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE
TABLE R613.3.2 MINIMUM PROPERTIESa FOR ORIENTED STRAND BOARD FACER MATERIAL IN SIP WALLS
427 FIGURE R613.4 SIP WALL PANEL
428 TABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY (inches)a
429 TABLE R613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (inches)a
430 FIGURE R613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
431 FIGURE R613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R613.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
432 FIGURE R613.5(5) SIP WALL-TO-WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only)
FIGURE R613.5.1 SIP WALL FRAMING CONFIGURATION
433 FIGURE R613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE R613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS
434 FIGURE R613.9 SIP CORNER FRAMING DETAIL
TABLE R613.10 MAXIMUM SPANS FOR 11 7/8-INCH-DEEP SIP HEADERS (feet)a
436 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
437 TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
438 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
439 TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
440 TABLE R702.7.1 CLASS III VAPOR RETARDERS
SECTION R703 EXTERIOR COVERING
442 TABLE R703.4 WEATHER-RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
443 TABLE R703.4—continued WEATHER-RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
444 TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c
445 FIGURE R703.7 MASONRY VENEER WALL DETAILS
446 FIGURE R703.7—continued MASONRY VENEER WALL DETAILS
447 TABLE R703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.7(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, WOOD FRAMING, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
448 FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
449 TABLE R703.7.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d
TABLE R703.7.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
FIGURE R703.7.3.2 MASONRY VENEER OPENING
450 TABLE R703.7.4 TIE ATTACHMENT AND AIR SPACE REQUIREMENTS
454 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
456 TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
457 TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
458 TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
459 TABLE R802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
460 TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
461 TABLE R802.5.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
462 TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
463 TABLE R802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
464 TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
465 TABLE R802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
466 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)
467 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)
468 TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
469 TABLE R802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
470 TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)
471 TABLE R802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)
472 TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
473 TABLE R802.5.1(7)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
474 TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
475 TABLE R802.5.1(8)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
476 TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS
477 FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION
478 FIGURE R802.7.1.1 RAFTER NOTCH
FIGURE R802.7.1.2 CEILING JOIST TAPER CUT
480 SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
SECTION R804 STEEL ROOF FRAMING
481 TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (POUNDS PER CONNECTION
482 TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (POUNDS PER CONNECTIO
483 FIGURE R804.1.2 IN-LINE FRAMING
TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES
TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
484 FIGURE R804.2(1) C-SHAPED SECTION
FIGURE R804.2(2) TRACK S
TABLE R804.2.4 SCREW SUBSTITUTION FACTOR
485 FIGURE R804.2.5.1 WEB HOLES
FIGURE R804.2.5.3 WEB HOLE PATCH
486 FIGURE R804.3 STEEL ROOF CONSTRUCTION
487 TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa
TABLE R804.3.1.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 KSI STEEL
488 TABLE R804.3.1.1(2) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 KSI STEEL
489 TABLE R804.3.1.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 KSI STEEL
490 TABLE R804.3.1.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 KSI STEEL
491 TABLE R804.3.1.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b 33 KSI STEEL
492 TABLE R804.3.1.1(6) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a,b 33 KSI STEEL
493 TABLE R804.3.1.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 KSI STEEL
494 TABLE R804.3.1.1(8) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 KSI STEEL
495 TABLE R804.3.1.1(9) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
FIGURE R804.3.1.1(1) JOIST TO RAFTER CONNECTION
496 FIGURE R804.3.1.1(2) BEARING STIFFENER
FIGURE R804.3.1.4(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL
498 FIGURE R804.3.1.4(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
FIGURE R804.3.1.5 SPLICED CEILING JOISTS
499 TABLE R804.3.2.1(1) ROOF RAFTER SPANSa, b, c 33 KSI STEEL
500 TABLE R804.3.2.1(2) ROOF RAFTER SPANSa, b, c 50 KSI STEEL
501 TABLE R804.3.2.1(3) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
502 FIGURE R804.3.2.4 HIP MEMBER OR RIDGE MEMBER CONNECTION
TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTER TO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
503 TABLE R804.3.3.2 HIP MEMBER SIZES, 33 ksi STEEL
TABLE R804.3.3.3 HIP SUPPORT COLUMN SIZES
505 TABLE R804.3.3.4(1) UPLIFT STRAP CONNECTION REQUIREMENTS HIP SUPPORT COLUMN AT CEILING LINE
FIGURE R804.3.3.4(1) JACK RAFTER CONNECTION AT EAVE
506 TABLE R804.3.3.4(2) CONNECTION REQUIREMENTS HIP MEMBER TO HIP SUPPORT COLUMN
FIGURE R804.3.3.4(2) HIP SUPPORT COLUMN
507 TABLE R804.3.3.4(3) UPLIFT STRAP CONNECTION REQUIREMENTS HIP MEMBER TO WALL
FIGURE R804.3.3.4(3) HIP CONNECTIONS AT RIDGE
508 FIGURE R804.3.3.4(4) HIP CONNECTIONS AT RIDGE AND BOX COLUMN
509 FIGURE R804.3.3.4(5) HIP MEMBER CONNECTION AT WALL CORNER
FIGURE R804.3.6(1) ROOF OR CEILING OPENING
510 FIGURE R804.3.6(2) HEADER TO TRIMMER CONNECTION
TABLE R804.3.8(1) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEETa, b, c, d, e, f
511 FIGURE R804.3.8(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
TABLE R804.3.8(2) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED CEILING HEIGHT = 9 OR 10 FEETa, b, c, d, e, f
512 FIGURE R804.3.8(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
TABLE R804.3.8(3) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS WOOD STRUCTURAL PANEL SHEATHED CEILING HEIGHT = 8, 9 OR 10 FEETa, b, c, d
513 FIGURE R804.3.8(3) ROOF BLOCKING DETAIL
SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
514 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
SECTION R807 ATTIC ACCESS
516 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 ROOF CLASSIFICATION
SECTION R903 WEATHER PROTECTION
517 SECTION R904 MATERIALS
SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
TABLE R905.2.4.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158
TABLE R905.2.4.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
519 TABLE R905.2.8.2 VALLEY LINING MATERIAL
520 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
522 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
523 TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
524 TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
525 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS
526 TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS
527 SECTION R906 ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 REROOFING
528 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
529 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
530 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
531 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
SECTION R1002 MASONRY HEATERS
532 SECTION R1003 MASONRY CHIMNEYS
534 TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
535 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
536 FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
FIGURE R1003.20 CHIMNEY CRICKET
TABLE R1003.20 CRICKET DIMENSIONS
SECTION R1004 FACTORY-BUILT FIREPLACES
537 SECTION R1005 FACTORY-BUILT CHIMNEYS
SECTION R1006 EXTERIOR AIR SUPPLY
538 CHAPTER 11 [RE] ENERGY EFFICIENCY
540 CHAPTER 12 MECHANICAL ADMINISTRATION
542 CHAPTER 25 PLUMBING ADMINISTRATION
544 SECTION P2904 DWELLING UNIT FIRE SPRINKLER SYSTEMS
TABLE P2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
546 FIGURE P2904.2.4.2 MINIMUM ALLOWABLE DISTANCE BETWEEN SPRINKLER AND OBSTRUCTION
EQUATION 29-1
548 TABLE P2904.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a, b
TABLE P2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
549 TABLE P2904.6.2(3) ELEVATION LOSS (PLe)
TABLE P2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING
550 TABLE P2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
551 TABLE P2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
552 TABLE P2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
553 TABLE P2904.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX AND PE-RT TUBING
554 TABLE P2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX AND PE-RT TUBING
556 CHAPTER 34 GENERAL REQUIREMENTS
558 CHAPTER 44 REFERENCED STANDARDS
AAMA
ACI
ACCA
559 AFPA
AISI
AITC
ANSI
560 APA
561 APSP
ASCE/SEI
ASHRAE
ASME
563 ASSE
ASTM
572 AWPA
AWS
AWWA
CGSB
573 CISPI
CPA
CPSC
CSA
575 CSSB
DASMA
DOC
DOTn
FEMA
576 FM
GA
HPVA
HVI
ICC
577 ISO
MSS
NAIMA
NCMA
NFPA
578 NSF
PCA
SBCA
SMACNA
579 TMS
TPI
UL
580 ULC
581 US-FTC
WDMA
582 APPENDIX K SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIR-BORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
584 APPENDIX L PERMIT FEES
586 INDEX
594 NEW TOOLS FOR YOUR RESIDENTIAL CODE
MN MinnesotaResidentialCode 2015
$50.92