MN PlumbingCode 2020
$57.42
Minnesota Plumbing Code
Published By | Publication Date | Number of Pages |
MN | 2020 |
The new 2020 Minnesota Plumbing Code contains many new provisions and amendments that every user will need to purchase and become familiar with. Some of the key updates to the Minnesota Plumbing Code include: • New sound transmission provisions for plumbing piping systems. New provisions for trenching excavation and backfill, rehabilitation of piping systems, and Schedule 40 PVC and ABS DWV and storm pipe expansion table (Chapter 3) • New product standards for plumbing fixtures such as wall hung fixtures, waste fittings, lavatories, showers, bathtubs and whirlpool bathtubs, flushometer valves, sinks and eyewash stations; and signage for single use toilet facilities (Chapter 4) • New backflow protection provisions for chemical dispensers, new material provisions for pipes, tubes, fittings and joint methods for water supply and distribution, piping Insulation, and new pressure testing for the hot and cold-water supply system (Chapter 6) • New material requirements for drain, waste, vent pipe and fittings (Chapter 7) • New provisions for condensate waste and control (Chapter 8) • Circuit venting (Chapter 9) • Methods of testing storm drainage systems (Chapter 11) • Updated ASSE Series 5000 testing procedures • Appendix I — Installation standard for PEX tubing systems for hot- and cold-water distribution • New Useful Tables As Chapter 4714 of the Minnesota State Building Code, this will be enforced as law effective December 17, 2021.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
4 | Copyright |
6 | MINNESOTA DISCLAIMER ACKNOWLEDGEMENTS |
7 | FOREWORD REVISION MARKINGS |
8 | UPC NOTICES AND DISCLAIMERS |
9 | 2018 UPC FOREWORD |
11 | TABLE OF CONTENTS |
23 | TITLE: INCORPORATION BY REFERENCE 4714.0050 Title: Incorporation by Reference |
25 | BASIC PLUMBING PRINCIPLES 4714.0100 Basic Plumbing Principles |
27 | CONFORMANCE WITH CODE 4714.0101 Conformance with Code |
29 | CHAPTER 1 ADMINISTRATION (DELETED |
31 | CHAPTER 2 DEFINITIONS 201.0 General 201.1 Applicability 202.0 Definition of Terms 202.1 General |
43 | CHAPTER 3 GENERAL REGULATIONS 301.0 General 301.1 Applicability 301.2 Minimum Standards 301.3 Alternate Materials and Methods of Construction Equivalency 301.4 Flood Hazard Areas |
44 | 301.5 Alternative Engineered Design 302.0 Iron Pipe Size (IPS) Pipe 302.1 General 303.0 Disposal of Liquid Waste 303.1 General 304.0 Connections to Plumbing System Required 304.1 General 305.0 Damage to Drainage System or Public Sewer 305.1 Unlawful Practices 306.0 Industrial Wastes 306.1 Detrimental Wastes 306.2 Safe Discharge |
45 | 307.0 Location 307.1 System 307.2 Ownership 308.0 Improper Location 308.1 General 309.0 Workmanship 309.1 Engineering Practices 309.2 Concealing Imperfections 309.3 Burred Ends 309.4 Installation Practices 309.5 Sound Transmission 310.0 Prohibited Fittings and Practices 310.1 Fittings 310.2 Drainage and Vent Piping 310.3 Waste Connection 310.4 Use of Vent and Waste Pipes 310.5 Obstruction of Flow 310.6 Dissimilar Metals 310.7 Direction of Flow 310.8 Screwed Fittings 311.0 Use of Public Sewer and Water Systems Required 311.1 General 312.0 Protection of Piping, Materials, and Structures 312.1 General |
46 | 312.2 Installation 312.3 Building Sewer and Drainage Piping 312.4 Corrosion, Erosion, and Mechanical Damage 312.5 Protectively Coated Pipe 312.6 Freezing Protection 312.7 Fire-Resistant Construction 312.8 Waterproofing of Openings 312.9 Steel Nail Plates 312.10 Sleeves 312.11 Structural Members 312.12 Rodentproofing 313.0 Hangers and Supports 313.1 General 313.2 Material 313.3 Suspended Piping 313.4 Alignment 313.5 Underground Installation 313.6 Hanger Rod Sizes |
47 | Table 313.6 Hanger Rod Sizes 314.0 Trenching, Excavation, and Backfill 314.1 Trenches 314.2 Tunneling and Driving 314.3 Open Trenches 314.4 Excavations 315.0 Joints and Connections 315.1 Unions 315.2 Prohibited Joints and Connections 316.0 Increasers and Reducers 316.1 General 317.0 Food-Handling Establishments 317.1 General 318.0 Test Gauges 318.1 General 318.2 Pressure Tests (10 psi or less 318.3 Pressure Tests (greater than 10 psi to 100 psi |
48 | 318.4 Pressure Tests (exceeding 100 psi 318.5 Pressure Range 319.0 Medical Gas and Vacuum Systems (Deleted 320.0 Rehabilitation of Piping Systems 320.1 General |
49 | Table 313.3 Hangers and Supports |
50 | Table 313.3.1 Schedule 40 PVC and ABS DWV and Storm Expansion Table |
51 | CHAPTER 4 PLUMBING FIXTURES AND FIXTURE FITTINGS 401.0 General 401.1 Applicability 401.2 Quality of Fixtures 402.0 Installation 402.1 Cleaning 402.2 Joints 402.3 Securing Fixtures 402.4 Wall-Hung Fixtures 402.5 Setting 402.6 Flanged Fixture Connections 402.7 Supply Fittings 402.8 Installation |
52 | 402.9 Design and Installation of Plumbing Fixtures 402.10 Slip Joint Connections 402.11 Future Fixtures 403.0 Accessible Plumbing Facilities 403.1 General 403.2 Fixtures and Fixture Fittings for Persons with Disabilities 403.3 Exposed Pipes and Surfaces 404.0 Waste Fittings and Overflows 404.1 Waste Fittings 404.2 Overflows 405.0 Prohibited Fixtures 405.1 Prohibited Water Closets 405.2 Prohibited Urinals 406.0 Special Fixtures and Specialties 406.1 Water and Waste Connections 406.2 Special Use Sinks 406.3 Special Use Fixtures 406.4 Zinc Alloy Components 407.0 Lavatories 407.1 Application 407.2 Water Consumption 407.3 Limitation of Hot Water Temperature for Public Lavatories |
53 | 407.5 Waste Outlet 407.6 Overflow 408.0 Showers 408.1 Application 408.2 Water Consumption 408.3 Individual Shower and Tub-Shower Combination Control Valves 408.4 Waste Outlet 408.5 Finished Curb or Threshold 408.6 Shower Compartments 408.7 Lining for Showers and Receptors |
54 | 408.8 Public Shower Floors 408.9 Location of Valves and Heads 408.10 Water Supply Riser 409.0 Bathtubs and Whirlpool Bathtubs 409.1 Application 409.2 Waste Outlet 409.3 Overflow 409.4 Limitation of Hot Water in Bathtubs and Whirlpool Bathtubs 409.5 Backflow Protection |
55 | 409.6 Installation and Access 410.0 Bidets 410.1 Application 410.2 Backflow Protection 410.3 Limitation of Water Temperature in Bidets 411.0 Water Closets 411.1 Application 411.2 Water Consumption 411.3 Water Closet Seats 411.4 Personal Hygiene Devices 412.0 Urinals 412.1 Application 412.2 Backflow Protection 413.0 Flushing Devices 413.1 Where Required 413.2 Flushometer Valves |
56 | 413.3 Flush Tanks 413.4 Water Supply for Flush Tanks 413.5 Overflows in Flush Tanks 414.0 Dishwashing Machines 414.1 Application 414.2 Backflow Protection 414.3 Drainage Connection 415.0 Drinking Fountains 415.1 Application 415.2 Public Use Fountains 415.3 Drainage Connection 415.4 Location 416.0 Emergency Eyewash and Shower Equipment 416.1 Application 416.2 Water Supply 416.3 Installation 416.4 Location 416.5 Drain 417.0 Faucets and Fixture Fittings 417.1 Application 417.2 Deck Mounted Bath/Shower Valves 417.3 Handheld Showers 417.4 Faucets and Fixture Fittings with Hose Connected Outlets |
57 | 417.5 Separate Controls for Hot and Cold Water 417.6 Low Pressure Water Dispenser 418.0 Floor Drains 418.1 Application 418.2 Strainer 418.3 Location of Floor Drains 418.4 Food Storage Areas 418.5 Floor Slope 418.6 Elevator Pit Drain 418.7 Garage and Parking Area Floor Drains 419.0 Food Waste Disposers 419.1 Application 419.2 Drainage Connection 419.3 Water Supply 420.0 Sinks 420.1 Application 420.2 Water Consumption 420.3 Pre-Rinse Spray Valve 420.4 Waste Outlet |
58 | 421.0 Floor Sinks 421.1 Application 421.2 Strainers 422.0 Minimum Number of Required Fixtures 422.1 Required Minimum Number of Fixtures 423.0 Trench Drains 423.1 Trench Drains |
59 | CHAPTER 5 WATER HEATERS 501.0 General 501.1 Applicability Table 501.1(1) Water Heaters 502.0 Permits 502.1 General 503.0 Inspection (Deleted 504.0 Water Heater Requirements 504.3 Clearance Table 501.1(2) First Hour Rating 504.4 Pressure-Limiting Devices 504.5 Temperature-Limiting Devices 504.6 Temperature, Pressure, and Vacuum Relief Devices 505.0 Oil-Burning and Other Water Heaters 505.1 Water Heaters |
60 | 505.2 Safety Devices 505.3 Oil-Fired Water Heaters 505.4 Indirect-Fired Water Heaters 506.0 Air for Combustion and Ventilation (Deleted 507.0 Appliance and Equipment Installation Requirements 507.1 Dielectric Insulator 507.2 Seismic Provisions 507.3 Appliance Support 507.4 Ground Support 507.5 Drainage Pan 507.12 Flammable Vapors 507.13 Installation in Residential Garages |
61 | 507.24 Installation Instructions 507.25 Protection of Outdoor Appliances 507.26 Accessibility for Service 507.27 Clearance to Combustible Materials 508.0 Appliances on Roofs 508.4 Appliances in Attics and Under-Floor Spaces 509.0 Venting of Appliances (Deleted 510.0 Sizing of Category I Venting (Deleted |
63 | CHAPTER 6 WATER SUPPLY AND DISTRIBUTION 601.0 Hot and Cold Water Required 601.1 Applicability 601.2 General 601.3 Identification of a Potable and Nonpotable Water System Table 601.3.2 Minimum Length of Color Field and Size of Letters 602.0 Unlawful Connections 602.1 Prohibited Installation |
64 | 602.2 Cross-Contamination 602.3 Backflow Prevention 602.4 Approval by Authority 603.0 Cross-Connection Control 603.1 General 603.2 Approval of Devices or Assemblies 603.3 Backflow Prevention Devices, Assemblies, and Methods |
65 | Table 603.2 Backflow Prevention Devices, Assemblies, and Methods |
67 | Table 603.3.1 Minimum Air Gaps for Water Distribution 603.4 General Requirements |
68 | 603.5 Specific Requirements |
71 | 604.0 Materials 604.1 Pipe, Tube, and Fittings Table 604.1 Materials for Building Supply and Water Distribution Piping and Fittings |
72 | 604.2 Lead Content 604.3 Copper or Copper Alloy Tube 604.4 Hard-Drawn Copper or Copper Alloy Tubing 604.5 Flexible Connectors 604.6 Cast-Iron Fittings 604.7 Malleable Iron Fittings 604.8 Previously Used Piping and Tubing 604.9 Epoxy Coating 604.10 Plastic Materials 604.11 Solder 604.12 Flexible Corrugated Connectors 604.13 Water Heater Connectors 605.0 Joints and Connections 605.1 Copper or Copper Alloy Pipe, Tubing, and Joints |
73 | 605.2 CPVC Plastic Pipe and Joints |
74 | 605.3 CPVC/AL/CPVC Plastic Pipe and Joints 605.4 Ductile Iron Pipe and Joints 605.5 Galvanized Steel Pipe and Joints 605.6 PE Plastic Pipe/Tubing and Joints |
75 | 605.7 PE-AL-PE Plastic Pipe/Tubing and Joints 605.8 PE-RT 605.9 PEX Plastic Tubing and Joints 605.10 PEX-AL-PEX Plastic Tubing and Joints 605.11 Polypropylene (PP) Piping and Joints |
76 | 605.12 PVC Plastic Pipe and Joints 605.13 Stainless Steel Pipe and Joints 605.14 Slip Joints 605.15 Dielectric Unions 605.16 Joints Between Various Materials 606.0 Valves 606.1 General 606.2 Fullway Valve |
77 | 606.3 Multidwelling Units 606.4 Multiple Openings 606.5 Control Valve 606.6 Accessible 606.7 Multiple Fixtures 607.0 Potable Water Supply Tanks 607.1 General 607.2 Potable Water Tanks 607.3 Venting 607.4 Overflow 607.5 Valves 608.0 Water Pressure, Pressure Regulators, Pressure Relief Valves, and Vacuum Relief Valves 608.1 Inadequate Water Pressure 608.2 Excessive Water Pressure 608.3 Expansion Tanks, and Combination Temperature and Pressure-Relief Valves |
78 | 608.4 Pressure Relief Valves 608.5 Discharge Piping 608.6 Water-Heating Devices 608.7 Vacuum Relief Valves 609.0 Installation, Testing, Unions, and Location 609.1 Installation 609.2 Trenches 609.3 Under Concrete Slab 609.4 Testing 609.5 Unions |
79 | 609.6 Location 609.7 Abutting Lot 609.8 Low-Pressure Cutoff Required on Booster Pumps for Water Distribution Systems 609.9 Disinfection of Potable Water System 609.10 Water Hammer 609.11 Pipe Insulation 609.12 Water Meters |
80 | 610.0 Size of Potable Water Piping 610.1 Size 610.2 Pressure Loss 610.3 Quantity of Water 610.4 Sizing Water Supply and Distribution Systems 610.5 Sizing per Appendices A and C 610.6 Friction and Pressure Loss 610.7 Conditions for Using Table 610.4 610.8 Size of Meter and Building Supply Pipe Using Table 610.4 610.9 Size of Branches 610.10 Sizing for Flushometer Valves |
81 | Table 610.10 Flushometer Fixture Units for Water Sizing Using Table 610.3 610.11 Sizing Systems for Flushometer Tanks 610.12 Sizing for Velocity 610.13 Exceptions |
82 | Table 610.3 Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes |
83 | Table 610.4 Fixture Unit Table for Determining Water Pipe and Meter Sizes |
84 | 611.0 Water Conditioning Equipment 611.1 Application 611.2 Air Gap Discharge 611.3 Connection Tubing 611.4 Sizing of Residential Softeners Table 611.4 Sizing of Residential Water Softeners 611.5 Isolation and Bypass 612.0 Multipurpose Potable Water Piping Systems 612.1 General |
85 | CHAPTER 7 SANITARY DRAINAGE PART I Drainage Systems 701.0 Materials 701.1 Applicability 701.2 Drainage Piping 701.3 Drainage Fittings 701.4 Continuous Wastes 701.5 Lead 701.6 Caulking Ferrules 701.7 Soldering Bushings Table 701.6 Caulking Ferrules Table 701.7 Soldering Bushings 702.0 Fixture Unit Equivalents 702.1 Trap Size 702.2 Intermittent Flow 702.3 Continuous Flow |
86 | Table 701.2 Materials for Drain, Waste, Vent Pipe and Fittings |
87 | Table 702.1 Drainage Fixture Unit Values (DFU |
88 | Table 702.2(1) Maximum Drainage Fixture Units for a Trap and Trap Arm Table 702.2(2) Discharge Capacity in Gallons Per Minute for Intermittent Flow Only 703.0 Size of Drainage Piping 703.1 Minimum Size 703.2 Maximum Number of Fixture Units 703.3 Sizing per Appendix C 704.0 Fixture Connections (Drainage 704.1 Inlet Fittings 704.2 Single Vertical Drainage Pipe 704.3 Commercial Dishwashing Machines and Sinks 705.0 Joints and Connections 705.1 ABS and ABS Co-Extruded Plastic Pipe and Joints 705.2 Cast-Iron Pipe and Joints |
89 | Table 703.2 Maximum Unit Loading and Maximum Length of Drainage and Vent Piping 705.3 Copper or Copper Alloy Pipe (DWV) and Joints |
90 | 705.4 Galvanized Steel Pipe and Joints 705.5 Polyethylene (PE) Sewer Pipe 705.6 PVC and PVC Co-Extruded Plastic Pipe and Joining Methods 705.7 Stainless Steel Pipe and Joints |
91 | 705.8 Vitrified Clay Pipe and Joints 705.9 Special Joints 705.10 Joints Between Various Materials 706.0 Changes in Direction of Drainage Flow 706.1 Approved Fittings 706.2 Horizontal to Vertical 706.3 Horizontal to Horizontal 706.4 Vertical to Horizontal 707.0 Cleanouts 707.1 Plug |
92 | Table 707.1 Cleanouts 707.2 Approved 707.3 Watertight and Gastight 707.4 Location 707.5 Cleaning 707.6 Extension 707.7 Interceptor 707.8 Access 707.9 Clearance 707.10 Fittings 707.11 Pressure Drainage Systems 707.12 Countersunk Cleanout Plugs 707.13 Hubless Blind Plugs 707.14 Trap Arms 708.0 Grade of Horizontal Drainage Piping 708.1 General 709.0 Gravity Drainage Required 709.1 General 710.0 Drainage of Fixtures Located Below the Next Upstream Manhole or Below the Main Sewer Level 710.1 Backflow Protection |
93 | 710.2 Sewage Discharge 710.3 Sewage Ejector and Pumps 710.4 Discharge Line 710.5 Size of Building Drains and Sewers 710.6 Backwater Valves 710.7 Drainage and Venting Systems 710.8 Sump and Receiving Tank Construction 710.9 Alarm 710.10 Sump and Receiving Tank Covers and Vents 710.11 Air Tanks |
94 | 710.12 Grinder Pump Ejector 710.13 Macerating Toilet Systems 711.0 Suds Relief 711.1 General 712.0 Testing 712.1 Media 712.2 Water Test 712.3 Air Test 712.4 Negative Test 712.5 Finished Plumbing 712.6 Test Plugs or Caps PART II Building Sewers 713.0 Sewer Required 713.1 Where Required 713.2 Private Sewage Disposal System |
95 | 713.3 Public Sewer 713.4 Public Sewer Availability 713.6 Lot 713.7 Installation 714.0 Damage to Public Sewer or Private Sewage Disposal System 714.1 Unlawful Practices 714.2 Prohibited Water Discharge 714.3 Prohibited Sewer Connection 714.4 Commercial Food Waste Disposer 714.5 Tanks 715.0 Building Sewer Materials 715.1 Materials 715.2 Joining Methods and Materials 715.3 Existing Sewers 716.0 Markings 716.1 General 717.0 Size of Building Sewers 717.1 General 718.0 Grade, Support, and Protection of Building Sewers 718.1 Slope |
96 | Table 717.1 Maximum/Minimum Fixture Unit Loading on Building Sewer Piping 718.2 Support 718.3 Protection from Damage 719.0 Cleanouts 719.1 Locations 719.2 No Additional Cleanouts 719.3 Building Sewer Cleanouts 719.4 Cleaning 719.5 Access 719.6 Manholes 720.0 Sewer and Water Pipes 720.1 General 721.0 Location 721.1 Building Sewer 721.2 Abutting Lot |
97 | Table 721.1 Minimum Horizontal Distance Required from Building Sewer 722.0 Abandoned Sewers and Sewage Disposal Facilities (Deleted 723.0 Building Sewer Test 723.1 General 724.0 Recreational Vehicle Sanitary Disposal Station 724.1 Construction 724.2 Flushing Device 724.3 Drainage Pipe Sizes Table 724.3 Drainage Pipe Sizes |
99 | CHAPTER 8 INDIRECT WASTES 801.0 General 801.1 Applicability 801.2 Air Gap or Air Break Required 801.3 Food and Beverage Handling Establishments 801.5 Connections from Water Distribution System 801.6 Sterilizers 801.7 Drip or Drainage Outlets 802.0 Approvals 802.1 General 803.0 Indirect Waste Piping 803.1 Materials 803.2 Copper and Copper Alloys 803.3 Pipe Size and Length |
100 | 804.0 Indirect Waste Receptors 804.1 Standpipe Receptors 804.2 Domestic or Culinary Type Fixtures Prohibited as Receptors 805.0 Pressure Drainage Connections 805.1 General 806.0 Sterile Equipment 806.1 General 807.0 Appliances 807.1 Non-Classed Apparatus 807.2 Undiluted Condensate Waste 807.3 Domestic Dishwashing Machine 808.0 Cooling Water 808.1 General 809.0 Drinking Fountains 809.1 General 810.0 Steam and Hot Water Drainage Condensers and Sumps 810.1 High-Temperature Discharge 810.2 Sumps, Condensers, and Intercepting Tanks |
101 | 810.3 Cleaning 810.4 Strainers 811.0 Chemical Wastes 811.1 Pretreatment 811.2 Waste and Vent Pipes 811.3 Joining Materials 811.4 Access 811.5 Permanent Record 811.6 Chemical Vent 811.7 Discharge 811.8 Diluted Chemicals 811.9 Waste and Vent 812.0 Clear Water Wastes 812.1 General 813.0 Swimming Pools 813.1 General 814.0 Condensate Waste and Control 814.1 Condensate Disposal 814.2 Condensate Control |
102 | 814.4 Appliance Condensate Drains 814.5 Point of Discharge 814.6 Condensate Waste From Air-Conditioning Coils 814.7 Plastic Fittings |
103 | CHAPTER 9 VENTS 901.0 General 901.1 Applicability 901.2 Vents Required 901.3 Trap Seal Protection 902.0 Vents Not Required 902.1 Interceptor 903.0 Materials 903.1 Applicable Standards 903.2 Use of Copper or Copper Alloy Tubing 903.3 Changes in Direction 904.0 Size of Vents 904.1 Size 904.2 Length 905.0 Vent Pipe Grades and Connections 905.1 Grade 905.2 Horizontal Drainage Pipe 905.3 Vent Pipe Rise |
104 | 905.4 Roof Termination 905.5 Location of Opening 905.6 Common Vertical Pipe 906.0 Vent Termination 906.1 Roof Termination 906.2 Clearance 906.3 Use of Roof 906.4 Outdoor Installations 906.5 Joints 906.6 Lead 906.7 Frost or Snow Closure 907.0 Vent Stacks and Relief Vents 907.1 Drainage Stack 907.2 Yoke Vent 908.0 Wet Venting 908.1 Vertical Wet Venting 908.2 Horizontal Wet Venting for a Bathroom Group |
105 | 909.0 Special Venting for Island Fixtures 909.1 General 910.0 Combination Waste and Vent Systems 910.1 Where Permitted 910.2 Approval 910.3 Vents 910.4 Size 910.5 Vertical Waste Pipe 910.6 Cleanouts 910.7 Fixtures 911.0 Circuit Venting 911.1 Circuit Vent Permitted 911.2 Vent Size and Connection 911.3 Slope and Size of Horizontal Branch |
106 | 911.4 Relief Vent 911.5 Additional Fixtures 912.0 Engineered Vent System 912.1 General 912.2 Minimum Requirements |
107 | CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 General 1001.1 Applicability 1001.2 Where Required 1002.0 Traps Protected by Vent Pipes 1002.1 Vent Pipes 1002.2 Fixture Traps Table 1002.2 Horizontal Lengths of Trap Arms 1002.3 Change of Direction 1002.4 Vent Pipe Opening 1003.0 Traps — Described 1003.1 General Requirements 1003.2 Slip Joint Fittings 1003.3 Size 1004.0 Traps 1004.1 Prohibited |
108 | 1004.2 Movable Parts 1005.0 Trap Seals 1005.1 General 1006.0 Floor Drain Traps 1006.1 General 1007.0 Trap Seal Protection (Deleted 1008.0 Building Traps (Deleted 1009.0 Interceptors (Clarifiers) and Separators 1009.1 Where Required 1009.2 Approval 1009.3 Design 1009.4 Relief Vent 1009.5 Location 1009.6 Maintenance of Interceptors 1009.7 Discharge 1010.0 Slaughterhouses, Packing Establishments, etc 1010.1 Slaughterhouses 1011.0 Minimum Requirements for Auto Wash Racks 1011.1 General 1012.0 Commercial and Industrial Laundries 1012.1 General 1013.0 Bottling Establishments 1013.1 General 1014.0 Grease Interceptors 1014.1 General |
109 | 1014.2 Hydromechanical Grease Interceptors Table 1014.2.1 Hydromechanical Grease Interceptor Sizing Using Gravity Flow Rates |
110 | 1014.3 Gravity Grease Interceptors Table 1014.3.6 Gravity Grease Interceptor Sizing |
111 | 1015.0 FOG (Fats, Oils, and Greases) Disposal System 1015.1 Purpose 1015.2 Components, Materials, and Equipment 1015.3 Sizing and Installation 1015.4 Performance 1016.0 Sand Interceptors 1016.1 Discharge 1016.2 Authority Having Jurisdiction 1016.3 Construction and Size 1016.4 Separate Use 1017.0 Oil and Flammable Liquid Interceptors 1017.1 Interceptors Required 1017.2 Design of Interceptors |
113 | CHAPTER 11 STORM DRAINAGE 1101.0 General 1101.1 Applicability 1101.2 Where Required 1101.3 Storm Water Drainage to Sanitary Sewer Prohibited 1101.4 Material Uses Table 1101.4.6 Materials for Subsoil Drain Pipe and Fittings 1101.5 Expansion Joints Required 1101.6 Subsoil Drains |
114 | 1101.7 Building Subdrains 1101.8 Areaway Drains 1101.9 Window Areaway Drains 1101.10 Filling Stations and Motor Vehicle Washing Establishments 1101.11 Paved Areas 1101.12 Roof Drainage 1101.13 Cleanouts 1101.14 Rainwater Sumps 1101.15 Traps on Storm Drains and Leaders |
115 | 1101.16 Leaders, Conductors, and Connections 1102.0 Roof Drains 1102.1 Applications 1102.2 Dome Strainers Required 1102.3 Roof Drain Flashings 1103.0 Size of Leaders, Conductors, and Storm Drains 1103.1 Vertical Conductors and Leaders 1103.2 Size of Horizontal Storm Drains and Sewers 1103.3 Reduction in Size Prohibited 1103.4 Side Walls Draining onto a Roof 1104.0 Values for Continuous Flow 1104.1 General 1105.0 Controlled-Flow Roof Drainage 1105.1 Application |
116 | Table 1105.1(1) Controlled-Flow Maximum Roof Water Depth Table 1105.1(2) Distance of Scupper Bottoms Above Roof 1105.2 Setback Roofs 1106.0 Siphonic Roof Drainage System 1106.1 General Requirements 1106.2 Design Criteria |
117 | 1106.3 Proof of Suitability 1107.0 Testing 1107.1 Testing Required 1107.2 Methods of Testing Storm Drainage Systems |
118 | Table 1103.1 Sizing Roof Drains, Leaders, and Vertical Rainwater Piping |
119 | Table 1103.2 Sizing of Horizontal Rainwater Piping |
120 | Table 1103.3 Size of Gutters |
121 | CHAPTER 12 FUEL GAS PIPING (DELETED |
123 | CHAPTER 13 HEALTH CARE FACILITIES AND MEDICAL GAS AND VACUUM SYSTEMS (DELETED |
125 | CHAPTER 14 FIRESTOP PROTECTION (DELETED |
127 | CHAPTER 15 ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS (DELETED |
129 | CHAPTER 16 NONPOTABLE RAINWATER CATCHMENT SYSTEMS 1601.0 General 1601.1 Applicability 1601.2 System Design 1601.3 Permit 1601.4 Component Identification 1601.5 Maintenance and Inspection Table 1601.5 Minimum Alternate Water Source Testing, Inspection, and Maintenance Frequency |
130 | 1601.6 Operation and Maintenance Manual 1601.7 Minimum Water Quality Requirements 1601.8 Material Compatibility 1601.9 System Controls 1601.10 Separation Requirements 1601.11 Abandonment 1601.12 Sizing 1602.0 Nonpotable Rainwater Catchment Systems 1602.1 General 1602.2 Plumbing Plan Submission 1602.3 System Changes 1602.4 Connections to Potable or Reclaimed (Recycled) Water Systems |
131 | 1602.5 Initial Cross-Connection Test 1602.6 Sizing 1602.7 Rainwater Catchment System Materials 1602.8 Rainwater Catchment System Color and Marking Information 1602.9 Design and Installation 1603.0 Rainwater Storage Tanks 1603.1 General |
132 | 1603.2 Construction 1603.3 Location 1603.4 Above Grade 1603.5 Below Grade 1603.6 Drainage and Overflow 1603.7 Animals and Insects 1603.8 Marking 1603.9 Storage Tank Venting 1603.10 Pumps 1603.11 Roof Drains 1603.12 Water Quality Devices and Equipment 1603.13 Freeze Protection 1603.14 Debris Removal 1604.0 Signs 1604.1 General 1604.2 Commercial, Industrial, and Institutional Restroom Signs |
133 | 1604.3 Equipment Room Signs 1605.0 Inspection and Testing 1605.1 General 1605.2 Supply System Inspection and Test 1605.3 Cross-Connection Inspection and Testing |
135 | CHAPTER 17 REFERENCED STANDARDS 1701.0 General 1701.1 Standards Table 1701.1 Referenced Standards |
147 | 1701.2 Standards, Publications, Practices, and Guides Table 1701.2 Standards, Publications, Practices, and Guides |
155 | APPENDICES TABLE OF CONTENTS |
157 | Appendix A Recommended Rules for Sizing the Water Supply System |
171 | Appendix B Explanatory Notes on Combination Waste and Vent Systems |
173 | Appendix I Installation Standard for PEX Tubing Systems for Hot- and Cold-Water Distribution |
181 | USEFUL TABLES |
195 | CHAPTER 4716 PLUMBER LICENSING AND APPRENTICE REGISTRATION |
203 | ADMINISTRATION |
215 | MISCELLANEOUS STATUTES RELATED TO THE MINNESOTA PLUMBING CODE 144.3855 326B.41 – 326B.59 |
231 | ASSE SERIES 5000 FIELD TEST PROCEDURES ASSE 1013 3 Valve Test Procedure |
233 | ASSE 1015 3 Valve Test Procedure |
235 | ASSE 1020 3 Valve Test Procedure |
237 | ASSE 1056 3 Valve Test Procedure |
239 | INDEX |