MN Residential PlumbingCode 2000
$28.60
Minnesota State Residential and Plumbing Code
Published By | Publication Date | Number of Pages |
MN | 2000 | 398 |
Minnesota State Residential and Plumbing Code is based on the 2000 IRC® and the Minnesota Plumbing Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | COVER |
2 | Copyright |
3 | Title Page |
5 | PREFACE |
7 | TABLE OF CONTENTS |
13 | Part I – Administrative CHAPTER 1 – ADMINISTRATION |
15 | MINNESOTA RULES, CHAPTER 1300 1300.0010 – ADMINISTRATION 1300.0020 – TITLE 1300.0030 – PURPOSE AND APPLICATION 1300.0040 – SCOPE 1300.0050 – CHAPTERS OF MINNESOTA STATE BUILDING CODE |
16 | 1300.0060 – OPTIONAL ADMINISTRATION 1300.0070 – DEFINITIONS |
17 | 1300.0080 – CODE ADOPTION AND AMENDMENTS 1300.0090 – DEPARTMENT OF BUILDING SAFETY 1300.0110 – DUTIES AND POWERS OF BUILDING OFFICIAL |
19 | 1300.0120 – PERMITS |
20 | 1300.0130 – CONSTRUCTION DOCUMENTS |
21 | 1300.0140 – VIOLATIONS 1300.0150 – VIOLATIONS, PENALTY |
22 | 1300.0160 – FEES |
23 | 1300.0170 – STOP WORK ORDER 1300.0180 – UNSAFE BUILDINGS OR STRUCTURES 1300.0190 – TEMPORARY STRUCTURES AND USES 1300.0210 – INSPECTIONS |
24 | 1300.0220 – CERTIFICATE OF OCCUPANCY |
25 | 1300.0230 – BOARD OF APPEALS 1300.0240 – DISCLAIMER CLAUSE 1300.0250 – SEVERABILITY |
27 | MINNESOTA RULES, CHAPTER 1303 1303.1000 – TITLE 1303.1100 – PURPOSE 1303.1200 – RESTROOM FACILITIES IN PUBLIC ACCOMODATIONS 1303.1300 – SPACE FOR COMMUTER VANS 1303.1400 – AUTOMATIC GARAGE DOOR OPENING SYSTEMS 1303.1500 – RECYCLING SPACE Subp. 5. TABLE 1-A MINIMUM RECYCLING SPACE REQUIREMENTS |
28 | 1303.1600 – FOOTING DEPTH FOR FROST PROTECTION 1303.1700 – GROUND SNOW LOAD 1303.1800 – RADIAL ICE ON TOWERS 1303.1900 – CONVENTIONAL FOUNDATION CONSTRUCTION TABLE 2-A – FOUNDATION WALL REINFORCEMENT REQUIREMENTS OF 12-INCH THICK HOLLOW UNIT MASONRY OR 8-INCH THICK CAST-IN-PLACE (CIP) CONCRETE. |
29 | TABLE 2-B – TYPES OF SOILS AND THEIR PROPERTIES 1303.2000 – EXTERIOR WOOD DECKS, PATIOS, AND BALCONIES |
30 | 1303.2100 – BLEACHER SAFETY |
31 | MINNESOTA RULES, CHAPTER 1309 1309.0010 – ADOPTION OF INTERNATIONAL RESIDENTIAL CODE (IRC) BY REFERENCE 1309.0020 – REFERENCES TO OTHER ICC CODES 1309.0030 – ADMINISTRATIVE PROCEDURE CRITERIA |
32 | 1309.0040 – VIOLATION |
33 | Part II – Definitions CHAPTER 2 – DEFINITIONS SECTION R201 – GENERAL SECTION R202 – DEFINITIONS |
45 | Part III – Building Planning and Construction CHAPTER 3 – BUILDING PLANNING SECTION R301 – DESIGN CRITERIA TABLE R301.2(1) – CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA |
46 | TABLE R301.2(2) – COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B |
47 | TABLE R301.2(3) – HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) FIGURE R301.2(1) – ISOLINES OF THE 97 1/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (FARENHEIT) |
48 | FIGURE R301.2(2) – INTERNATIONAL RESIDENTIAL CODE SEISMIC DESIGN CATEGORIES – SITE CLASS D |
51 | FIGURE R301.2(3) – WEATHERING PROBABILITY MAP FOR CONCRETE |
52 | FIGURE R301.2(4) – BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL |
56 | FIGURE R301.2(5) – Not adopted by the state of Minnesota |
57 | FIGURE R301.2(6) – TERMITE INFESTATION PRABABILITY MAP |
58 | FIGURE R301.2(7) – DECAY PROBABILITY MAP |
59 | FIGURE R301.2(8) – COMPONENT AND CLADDING PRESSURE ZONES |
60 | TABLE R301.2.1.2 – WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS a,b,c,d TABLE R301.2.1.3 – EQUIVALENT BASIC WIND SPEEDSa |
61 | TABLE R301.2.2.1.1 -SEISMIC DESIGN CATEGORY DETERMINATION |
62 | TABLE R301.2.2.4 – WALL-BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa |
63 | TABLE R301.4 – MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) |
64 | TABLE R301.5 – MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION TABLE R301.6 – ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS SECTION R302 – LOCATION ON LOT SECTION R303 – LIGHT, VENTILATION AND HEATING |
65 | SECTION R304 – MINIMUM ROOM AREAS SECTION R305 – CEILING HEIGHT SECTION R306 – SANITATION |
66 | SECTION R307 – TOILET, BATH AND SHOWER SPACES FIGURE R307.2 – MINIMUM FIXTURE CLEARANCES |
67 | SECTION R308 – GLAZING TABLE R308.3 – MINIMUM CATEGORY CLASSIFICATION OF GLAZING |
68 | SECTION R309 – GARAGES AND CARPORTS |
69 | SECTION R310 – EMERGENCY ESCAPE AND RESCUE OPENINGS |
70 | SECTION R311 – EXITS SECTION R312 – LANDINGS SECTION R313 – RAMPS SECTION R314 – STAIRWAYS |
71 | SECTION R315 – HANDRAILS SECTION R316 – GUARDS SECTION R317 – SMOKE ALARMS |
72 | SECTION R318 – FOAM PLASTIC |
73 | SECTION R319 – FLAME SPREAD AND SMOKE DENSITY SECTION R320 – INSULATION SECTION R321 – DWELLING UNIT SEPARATION |
74 | SECTION R322 – MOISTURE VAPOR RETARDERS |
75 | SECTION R323 – PROTECTION AGAINST DECAY SECTION R324 – PROTECTION AGAINST TERMITES |
76 | SECTION R325 – SITE ADDRESS SECTION R326 – ACCESSIBILITY SECTION R327 – FLOOD-RESISTANT CONSTRUCTION |
79 | CHAPTER 4 – FOUNDATIONS SECTION R401 – GENERAL TABLE R401.4.1 – PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa SECTION R402 – MATERIALS |
80 | SECTION R403 – FOOTINGS |
81 | TABLE R402.2 – MINIIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE TABLE R403.1 – MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS (inches) |
82 | FIGURE R403.1(1) – CONCRETE AND MASONRY FOUNDATION DETAILS |
83 | FIGURE R403.1(2) – PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION |
84 | FIGURE R403.1(3) – PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION |
85 | FIGURE R403.1.7.1 – FOUNDATION CLEARANCE FROM SLOPES |
86 | TABLE R403.3 – MINIMUM INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS a |
87 | FIGURE R403.3(1) – INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS |
88 | FIGURE R403.3(2) – AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD SECTION R404 – FOUNDATION WALLS |
89 | TABLE R404.1.1(1) – PLAIN CONCRETE AND MASONRY WALLS (Not adopted by the state of Minnesota) TABLE R404.1.1(2) – REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS |
90 | TABLE R404.1.1(3) – REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS TABLE R404.1.1(4) – REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS |
91 | FIGURE R404.1.5(1) – FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS |
93 | TABLE R404.2.3d – PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION |
94 | TABLE R404.4(1) – 5.5-INCH THICK FLAT ICF FOUNDATION WALLSa,b,c |
95 | TABLE R404.4(2) – 7.5-INCH THICK FLAT ICF FOUNDATION WALLSa,b,c,d TABLE R404.4(3) – 9.5-INCH THICK FLAT ICF FOUNDATION WALLSa,b,c,d |
96 | TABLE R404.4(4) – WAFFLE GRID ICF FOUNDATION WALLSa,b,c,d |
97 | TABLE R404.4(5) – SCREEN-GRID ICF FOUNDATION WALLSa,b,c |
98 | SECTION R405 – FOUNDATION DRAINAGE TABLE R405.1 – PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM |
99 | SECTION R406 – FOUNDATION WATERPROOFING AND DAMPPROOFING SECTION R407 – COLUMNS |
100 | SECTION R408 – UNDER-FLOOR SPACE |
101 | CHAPTER 5 – FLOORS SECTION R501 – GENERAL SECTION R502 – WOOD FLOOR FRAMING |
102 | FIGURE R502.2 – FLOOR CONSTRUCTION |
103 | TABLE R502.3.1(1) – FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES |
104 | TABLE R502.3.1(2) – FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES |
105 | TABLE R502.5(1) – GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS |
106 | TABLE R502.5(2) – GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS |
107 | FIGURE R502.8 – CUTTING, NOTCHING AND DRILLING |
108 | SECTION R503 – FLOOR SHEATHING |
109 | TABLE R503.1 – MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING TABLE R503.2.1.1(1) – ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa,b,c |
110 | TABLE R503.2.1.1(2) – ALLOWABLE SPANS FOR PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa SECTION R504 – PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND) SECTION R505 – STEEL FLOOR FRAMING |
111 | TABLE R505.2(1) – COLD-FORMED STEEL JOIST SIZES TABLE R505.2(2) – MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS TABLE R505.2(3) – MAXIMUM HOLE DIMENSIONS AND SPACING IN JOIST WEBS |
112 | FIGURE R505.2(1) – C-SECTION FIGURE R505.2(2) – TRACK SECTION FIGURE R505.2(3) – FLOOR JOIST WEB HOLES |
113 | TABLE R505.2.4 – SCREW SUBSTITUTION FACTOR FIGURE R505.3 – STEEL-FLOOR CONSTRUCTION |
115 | TABLE R505.3.1(1) – FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS a,b,c TABLE R505.3.1(2) – FLOOR FASTENING SCHEDULEa |
116 | FIGURE R505.3.1(1) – FLOOR TO LOAD-BEARING WALL STUD CONNECTION FIGURE R505.3.1(2) – FLOOR TO WOOD SILL CONNECTION |
117 | FIGURE R505.3.1(3) – FLOOR TO FOUNDATION CONNECTION FIGURE R505.3.1(4) – FLOOR CANTILEVER TO LOAD-BEARING WALL CONNECTION |
118 | FIGURE R505.3.1(5) – FLOOR CANTILEVER TO WOOD SILL CONNECTION |
119 | FIGURE R505.3.1(6) – FLOOR CANTILEVER TO FOUNDATION CONNECTION |
120 | FIGURE R505.3.1(7) – CONTINUOUS JOIST SPAN SUPPORTED ON STUD FIGURE R505.3.1(8) – LAPPED JOISTS SUPPORTED ON STUD |
121 | TABLE R505.3.2 – ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTSa,b |
122 | FIGURE R505.3.4 – BEARING STIFFENER FIGURE R505.3.6 – HOLE PATCH |
123 | SECTION R506 – CONCRETE FLOORS (ON GROUND) FIGURE R505.3.8 – TRACK SPLICE |
125 | CHAPTER 6 – WALL CONSTRUCTION SECTION R601 – GENERAL SECTION R602 – WOOD WALL FRAMING |
126 | TABLE R602.3(1) – FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
128 | TABLE R602.3(2) – ALTERNATE ATTACHMENTS |
129 | TABLE R602.3(3) – ALLOWABLE STUD SPACING FOR WOOD STRUCTURAL PANEL WALL SHEATHING TABLE R602.3(4) – ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa TABLE R602.3(5) – MAXIMUM STUD SPACING |
130 | FIGURE R602.3(1) – TYPICAL WALL, FLOOR AND ROOF FRAMING |
131 | FIGURE R602.3(2) – FRAMING DETAILS |
132 | TABLE R602.3.1 – MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A,B,C and Da,b,c |
135 | FIGURE R602.6(1) – NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS |
136 | FIGURE R602.6(2) – NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NOBEARING WALLS |
137 | FIGURE R602.6.1 – TOP PLATE FRAMING TO ACCOMODATE PIPING TABLE R602.7.2 – MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa |
138 | FIGURE R602.7.2 – TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION |
140 | TABLE R602.10.3 – WALL BRACING |
141 | TABLE R602.10.5 – LENGTH REQUIREMENTS FOR BRACED WALL PANELS IN A CONTINUOUSLY SHEATHED WALLa,b FIGURE R602.10.5 – EXTERIOR CORNER FRAMING |
143 | FIGURE R602.11.3 STEPPED FOUNDATION CONSTRUCTION |
144 | SECTION R603 STEEL WALL FRAMING TABLE R603.2(1) – LOAD-BEARING COLD-FORMED STEEL STUD SIZES TABLE R603.2(2) – MINIMUM THICKNESS OF COLD-FORMED STEEL STUDS |
145 | FIGURE R603.2(1) – C-SECTION FIGURE R603.2(2) – TRACK SECTION |
146 | FIGURE R603.2(3) – WEB HOLES |
147 | TABLE R603.2.4 – SCREW SUBSTITUTION FACTOR FIGURE R603.3 – STEEL WALL CONSTRUCTION |
148 | TABLE R603.3.1 – WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b,c FIGURE R603.3.1(1) – WALL TO FOUNDATION CONNECTION |
149 | FIGURE R603.3.1(2) – WALL TO WOOD SILL CONNECTION TABLE R603.3.2(1) – WALL FASTENING SCHEDULEa |
150 | TABLE R603.3.2(2) – COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS |
151 | TABLE R603.3.2(3) – COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS |
152 | TABLE R603.3.2(4) – COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS |
153 | TABLE R603.3.2(5) – COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS |
154 | TABLE R603.3.2(6) – COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS |
155 | TABLE R603.3.2(7) – COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS |
156 | TABLE R603.3.2(8) – COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS |
157 | TABLE R603.3.2(9) – COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS |
158 | TABLE R603.3.2(10) – COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS |
159 | TABLE R603.3.2(11) – COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS |
160 | TABLE R603.3.2(12) – COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS |
161 | TABLE R603.3.2(13) – COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS |
162 | FIGURE R603.3.5 – HOLE PATCH FIGURE R603.3.6 – TRACK SPLICE |
163 | FIGURE R603.4 – CORNER FRAMING |
164 | TABLE R603.6(1) – ALLOWABLE HEADER SPANSa,b Headers supporting roof and ceiling only (33 ksi steel) |
165 | TABLE R603.6(2) – ALLOWABLE HEADER SPANSa,b Headers supporting one floor, roof and ceiling )33 ksi steel) TABLE R603.6(3) – ALLOWABLE HEADER SPANSa,b,c Headers supporting one floor, roof and ceiling first story of a two-story building with center load bearing beam (33 ksi steel) |
166 | TABLE R603.6(4) – TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING TABLE R603.6(5) – HEADER TO KING STUD CONNECTION REQUIREMENTSa,b,c,d,e |
167 | FIGURE R603.6 – HEADER DETAIL |
168 | TABLE R603.7 – MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b,c,d,e |
169 | FIGURE R603.8.1 – BUILDING CONFIGURATION TABLE R603.8.1.2 – EDGE SCREW SPACING SHEARWALL LENGTH ADJUSTMENT FACTORS |
170 | FIGURE R603.8.1.2 – TYPE I AND TYPE II BRACED WALLS |
171 | TABLE R603.8.1.2.2 – TYPE II BRACED WALL LINE LENGTH ADJUSTMENT FACTORS TABLE R603.8.1.3 – REQUIRED HOLD-DOWN ANCHOR FORCE |
172 | FIGURE R603.8.1.3 – CORNER STUD HOLD-DOWN TABLE R603.8.1.4(1) TOP TRACK SPLICE SCREW SCHEDULE |
173 | TABLE R603.8.1.4(2) – REQUIRED SHEAR ANCHORAGE FOR BRACED WALLS FIGURE R603.8.1.4(1) – GABLE ROOF SHEATHING ATTACHMENT TO BRACE WALLS |
174 | FIGURE R603.8.1.4(2) – STRAP AND BLOCKING DIAPHRAGM LOAD TRANSFER AT ROOF EAVE |
175 | FIGURE R603.8.1.4(3) – FLOOR DIAPHRAGM – ATTACHMENT TO BRACED WALLS |
176 | TABLE R603.8.2.2 – LIGHT WEIGHT ROOF AND LIGHT WEIGHT EXTERIOR WALL TYPE I LENGTH ADJUSTMENT FACTORS |
177 | FIGURE R603.8.2(1) – SDC D1 SINGLE STORY OR TOP OF TWO STORY |
178 | FIGURE R603.8.2(2) – SDC D1 BOTTOM OF TWO STORY |
179 | FIGURE R603.8.2(3) – SDC D2 SINGLE STORY OF TOP OF TWO STORY |
180 | FIGURE R603.8.2(4) – SDC D2 BOTTOM OF TWO STORY |
181 | TABLE R603.8.3.1(1) – RANGE OF ALLOWABLE SIDEWALL LENGTHS ONE-STORY SLAB ON GRADE TABLE R603.8.3.1(2) – RANGE OF ALLOWABLE SIDEWALL LENGTHS ALL OTHER CASES |
182 | TABLE R603.8.3.1(3) – TYPE I BRACED WALL PANEL SIDEWALL SHEATHING LENGTH REQUIREMENTS TABLE R603.8.3.1(4) – TYPE I BRACED WALL PANEL ENDWALL SHEATHING LENGTH REQUIREMENTS |
184 | TABLE R603.8.3.2.1(1) – REQUIRED UPLIFT CAPACITY ROOF TRUSS OR RAFTER TO WALL TABLE R603.8.3.2.1(2) – UPLIFT STRAP CONNECTION REQUIREMENTS ROOF RAFTER OR TRUSS TO WALL |
185 | TABLE R603.8.3.2.2(1) – REQUIRED UPLIFT CAPACITY WALL ASSEMBLY TO WALL ASSEMBLY TABLE R603.8.3.2.2(2) – UPLIFT STRAP CONNECTION REQUIREMENTS WALL ASSEMBLY TO WALL ASSEMBLY |
186 | TABLE R603.8.3.2.3(1) – REQUIRED UPLIFT CAPACITY WALL ASSEMBLY TO FOUNDATION OR FLOOR ASSEMBLY TABLE R603.8.3.2.3(2) – UPLIFT STRAP CONNECTION REQUIREMENTS WALL ASSEMBLY TO FOUNDATION OR FLOOR ASSEMBLY |
187 | FIGURE R603.8.3.2.3 – WIND UPLIFT CONNECTOR SECTION R604 – WOOD STRUCTURAL PANELS SECTION R605 – PARTICLEBOARD SECTION R606 – GENERAL MASONRY CONSTRUCTION |
189 | TABLE R606.4 – ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY TABLE R606.8 – SPACING OF LATERAL SUPPORT FOR MASONRY WALLS |
191 | FIGURE R606.10(1) – ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF |
192 | FIGURE R606.10(2) – REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C |
193 | FIGURE R606.10(3) – REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D1 OR D2 |
194 | TABLE R606.11.3.2 – MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D1 |
195 | TABLE R606.11.4.1 – MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 TABLE R606.11.4.2 – MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 TABLE R606.14.1 – MINIMUM CORROSION PROTECTION SECTION R607 – UNIT MASONRY |
196 | TABLE R607.1 – MORTAR PROPORTIONSa,b |
197 | SECTION R608 – MULTIPLE WYTHE MASONRY SECTION R609 – GROUTED MASONRY |
198 | TABLE R609.1.1 – GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION TABLE R609.1.2 – GROUT SPACE DIMENSIONS AND POUR HEIGHTS |
199 | SECTION R610 – GLASS UNIT MASONRY |
200 | FIGURE R610.4.1 – GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE |
201 | SECTION R611 – INSULATING CONCRETE FORM WALL CONSTRUCTION |
202 | TABLE R611.3 – MINIMUM VERTICAL WALL REINFORCEMENT FOR FLAT ICF ABOVE-GRADE WALLSa,b,c,d FIGURE R611.3 – FLAT ICF WALL SYSTEM |
203 | TABLE R611.4(1) – MINIMUM VERTICAL WALL REINFORCEMENT FOR WAFFLE-GRID ICF ABOVE-GRADE WALLSa,b,c,d,e TABLE R611.4(2) – DIMENSIONAL REQUIREMENTS FOR CORES AND WEBS IN WAFFLE-GRID AND SCREEN-GRID ICF WALLSa,b |
204 | FIGURE R611.4 – WAFFLE-GRID ICF WALL SYSTEM TABLE R611.5 – MINIMUM VERTICAL WALL REINFORCEMENT FOR SCREEN-GRID ICF ABOVE-GRADE WALLSa,b,c,d,e |
205 | FIGURE R611.5 – SCREEN-GRID IFC WALL SYSTEM TABLE R611.7(1) – MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS |
206 | TABLE R611.7(2) – MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT AND SCREEN-GRID LOAD-BEARING WALLSa,b,c,d NO. 4 BOTTOM SIZE |
207 | TABLE R611.7(3) – MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT AND SCREEN-GRID LOAD-BEARING WALLSa,b,c,d NO. 5 BOTTOM BAR SIZE |
208 | TABLE R611.7(4) – MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d NO. 4 BOTTOM BAR SIZE |
209 | TABLE R611.7(5) – MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d NO. 5 BOTTOM BAR SIZE |
210 | TABLE R611.7(6) – MINIMUM BOTTOM BAR ICF LINTEL REINFORCEMENT FOR LARGE CLEAR SPANS IN LOAD-BEARING WALLSa,b,c,d TABLE R611.7(7) – MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS IN NONLOAD-BEARING WALLS a,b,c NO. 4 BOTTOM BAR SIZE |
211 | TABLE R611.7(8) – MINIMUM PERCENTAGE OF SOLID WALL LENGTH ALONG EXTERIOR WALL LINESa,b,c |
212 | TABLE R611.7(9) – MINIMUM PERCENTAGE OF SOLID WALL LENGTH FOR SEISMIC DESIGN CATEGORY Ca FIGURE R611.7(1) – ICF WALL CONSTRUCTION |
213 | FIGURE R611.7(2) – REINFORCEMENT OF OPENINGS FIGURE R611.7(3) – ICF LINTELS FOR FLAT AND SCREEN-GRID WALLS |
214 | FIGURE R611.7(4) – SINGLE FORM HEIGHT WAFFLE-GRID LINTEL FIGURE R611.7(5) – DOUBLE FORM HEIGHT WAFFLE-GRID LINTEL |
216 | TABLE R611.8 – FLOOR LEDGER-ICF WALL CONNECTION (SIDE-BEARING CONNECTION) REQUIREMENTSa,b,c |
217 | FIGURE R611.8(1) – SECTION CUT THROUGH FLAT WALL OR VERTICAL CORE OF WAFFLE- OR SCREEN-GRID WALL FIGURE R611.8(2)ÅICF WALL CONNECTION (SIDE-BEARING CONNECTION) – FLOOR LEDGER – ICF WALL CONNECTION (SIDE-BEARING CONNECTION) |
218 | FIGURE R611.8(3)ÅICF WALL CONNECTION (SIDE-BEARING CONNECTION) – FLOOR LEDGER – ICF WALL CONNECTION (SIDE-BEARING CONNECTION) FIGURE R611.8(4)ÅICF WALL SYSTEM CONNECTION – WOOD FLOOR LEDGER – ICF WALL SYSTEM CONNECTION (THROUGH-BOLT CONNECTION) |
219 | FIGURE R611.8(5) – WOOD FLOOR LEDGER TO ICF WALL SYSTEM CONNECTION DETAIL FIGURE R611.9 – ICF WALL TO TOP SILL PLATE (ROOF) CONNECTION |
220 | SECTION R612 – CONVENTIONALLY FORMED CONCRETE WALL CONSTRUCTION SECTION R613 – EXTERIOR WINDOWS AND GLASS DOORS |
221 | FIGURE R613.5(1) – THROUGH THE FRAME FIGURE R613.5(2) – FRAME CLIP FIGURE R613.5(3) – THROUGH THE FRAME FIGURE R613.5(4) – FRAME CLIP FIGURE R613.5(5) – THROUGH THE FRAME FIGURE R613.5(6) – THROUGH THE FRAME FIGURE R613.5(7) – FRAME CLIP FIGURE R613.5.(8) – THROUGH THE FLANGE |
223 | CHAPTER 7 – WALL COVERINGS SECTION R701 – GENERAL SECTION R702 – INTERIOR COVERING TABLE R702.1(1) – THICKNESS OF PLASTER TABLE R702.1(2) – GYPSUM PLASTER PROPORTIONSa |
224 | TABLE R702.1(3) – PORTLAND CEMENT PLASTER |
225 | TABLE R702.3.5 – MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD |
226 | SECTION R703 – EXTERIOR COVERING |
227 | TABLE R703.4 – WEATHER-RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESSa,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p,q |
229 | TABLE R703.5.2 – MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa,b,c |
230 | TABLE R703.7.3 – ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa,b,c |
231 | FIGURE R703.7 – MASONRY VENEER WALL DETAILS |
233 | FIGURE R703.7.1 – EXTERIOR MASONRY VENEER SUPPORT BY WOOD CONSTRUCTION (Not adopted by the State of Minnesota) |
235 | CHAPTER 8 – ROOF-CEILING CONSTRUCTION SECTION R801 – GENERAL SECTION R802 – WOOD ROOF FRAMING |
236 | TABLE R802.4(1) – CEILING JOIST SPANS FOR COMMON LUMBER SPECIES |
238 | TABLE R802.4(2) – CEILING JOIST SPANS FOR COMMON LUMBER SPECIES |
240 | TABLE R802.5.1(1) – RAFTER SPANS FOR COMMON LUMBER SPECIES |
242 | TABLE R802.5.1(2) – RAFTER SPANS FOR COMMON LUMBER SPECIES |
244 | TABLE R802.5.1(3) – RAFTER SPANS FOR COMMON LUMBER SPECIES |
246 | TABLE R802.5.1(4) – RAFTER SPANS FOR COMMON LUMBER SPECIES |
248 | TABLE R802.5.1(5) – RAFTER SPANS FOR COMMON LUMBER SPECIES |
250 | TABLE R802.5.1(6) – RAFTER SPANS FOR COMMON LUMBER SPECIES |
252 | TABLE R802.5.1(7) – RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD |
254 | TABLE R802.5.1(8) – RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD |
256 | TABLE R802.5.1(9) – RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa,b,c,d,e,f |
257 | FIGURE R802.5.1 – BRACED RAFTER CONSTRUCTION |
258 | TABLE R802.11 – REQUIRED STRENGTH OF TRUSS OR RAFTER TIE-DOWN CONNECTIONS TO RESIST WIND UPLIFT FORCESa,b,c,d |
259 | SECTION R803 – ROOF SHEATHING TABLE R803.1 – MINIMUM THICKNESS OF LUMBER ROOF SHEATHING SECTION R804 – STEEL ROOF FRAMING |
260 | TABLE R804.2(1) – LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES TABLE R804.2(2) – MINIMUM THICKNESS OF COLD-FORMED STEEL ROOF FRAMING MEMBERS FIGURE R804.2(1) – -C-SECTION FIGURE R804.2(2) – TRACK SECTION FIGURE R804.2(3) – WEB HOLES |
261 | TABLE R804.2.4 – SCREW SUBSTITUTION FACTOR TABLE R804.3 – ROOF FRAMING FASTENING SCHEDULEa,b |
262 | FIGURE R804.3 – STEEL ROOF CONSTRUCTION |
263 | TABLE R804.3.1(1) – ALLOWABLE SPANS FOR COLD-FORMED STEEL CEILING JOISTSa,b,c 10 psf live load (no attic storage) TABLE R804.3.1(2) – ALLOWABLE SPANS FOR COLD-FORMED STEEL CEILING JOISTSa,b,c 20 psf live load (Limited attic storage where development of future rooms is not possible) |
264 | TABLE R804.3.1(3) – NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO RAFTER CONNECTIONa FIGURE R804.3.1(1) – JOIST TO RAFTER CONNECTION |
265 | TABLE R804.3.3(1) – ALLOWABLE HORIZONTAL RAFTER SPANSa,b TABLE R804.3.3(2) – BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSIONa |
266 | TABLE R804.3.3.1 – NUMBER OF SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR RAFTER TO RIDGE MEMBER CONNECTIONa TABLE R804.3.3.1.1(1) – RIDGE TENSION STRAP CONNECTION REQUIREMENTS PER FOOT OF RIDGE SPANc |
267 | TABLE R804.3.3.1.1(2) – MINIMUM SIZE OF RIDGE STRAP FIGURE R804.3.3.1 – RIDGE BOARD CONNECTION |
268 | FIGURE R804.3.6 – HOLE PATCHING FIGURE R804.3.7(1) – SPLICED CEILING JOISTS |
269 | FIGURE R804.3.7(2) – TRACK SPLICE FIGURE R804.3.8 – BEARING STIFFENER |
270 | FIGURE R804.3.10(1) – ROOF OPENING SECTION R805 – CEILING FINISHES |
271 | FIGURE R804.3.10(2) – HEADER TO TRIMMER CONNECTION SECTION R806 – ROOF VENTILATION SECTION R807 – ATTIC ACCESS SECTION R808 – INSULATION CLEARANCE |
273 | CHAPTER 9 – ROOF ASSEMBLIES SECTION R901 – GENERAL SECTION R902 – ROOF CLASSIFICATION SECTION R903 – WEATHER PROTECTION SECTION R904 – MATERIALS |
274 | SECTION R905 – REQUIREMENTS FOR ROOF COVERINGS |
275 | TABLE R905.2.8.2 – VALLEY LINING MATERIAL TABLE R905.3.5 – TRANSVERSE BREAKING STRENGTH OF CONCRETE ROOF TILE |
276 | TABLE R905.3.7 – CLAY AND CONCRETE TILE ATTACHMENT |
277 | TABLE R905.6.5 – SLATE SHINGLE HEADLAP TABLE R905.7.4 – WOOD SHINGLE MATERIAL REQUIREMENTS TABLE R905.7.5 – WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
278 | TABLE R905.8.5 – WOOD SHAKE MATERIAL REQUIREMENTS TABLE R905.8.6 – WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE |
279 | TABLE R905.9.2 – BUILT-UP ROOFING MATERIAL STANDARDS |
280 | TABLE R905.10.3 – METAL ROOF COVERINGS STANDARDS AND INSTALLATION TABLE R905.11.2 – MODIFIED BITUMEN ROOFING MATERIAL STANDARDS |
281 | SECTION R906 – ROOF INSULATION SECTION R907 – REROOFING |
282 | FIGURE R907.3 – HAIL RISK MAPa,b |
283 | CHAPTER 10 – CHIMNEYS AND FIREPLACES SECTION R1001 – MASONRY CHIMNEYS |
284 | TABLE R1001.11(1) – NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa TABLE R1001.11(2) – NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZESa |
285 | FIGURE R1001.12.2 – FLUE SIZES FOR MASONRY CHIMNEYS |
286 | TABLE R1001.17 – CRICKET DIMENSIONS FIGURE R1001.15 – CLEARANCE FROM COMBUSTIBLES FIGURE R1001.17 – CHIMNEY CRICKET |
287 | SECTION R1002 – FACTORY-BUILT CHIMNEYS SECTION R1003 – MASONRY FIREPLACES |
288 | TABLE R1003.1 – SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS |
289 | FIGURE R1003.1 – FIREPLACE AND CHIMNEY DETAILS |
291 | FIGURE R1003.12 – CLEARANCE FROM COMBUSTIBLES SECTION R1004 – FACTORY-BUILT FIREPLACES SECTION R1005 EXTERIOR AIR SUPPLY |
293 | Part IV – Energy Conservation CHAPTER 11 – ENERGY (Provisions for energy, energy conservation, or references to the International Energy Conservation Code are deleted and replaced with Minnesota Statutes, section 16B.617. |
295 | Part V – Mechanical CHAPTER 12 – MECHANICAL (Provisions for mechanical or references to the International Mechanical Code, which include Chapters 12 through 24 of the IRC, are deleted and replaced with Minnesota Rules, Chapter 1346, the Minnesota Mechanical Code. |
297 | Part VII – Plumbing CHAPTER 25 – PLUMBING ADMINISTRATION ( Provisions for plumbing or references to ICC Plumbing Code, which include Chapters 25 through 32 of the IRC, shall be deleted and replaced with Minnesota Rules, Chapter 4715, the Minnesota Plumbing Code. |
299 | Part VIII – Electrical CHAPTER 34 – ELECTRICAL (Provisions for electrical or references to the ICC Electrical Code, which include Chapters 34 through 42 of the IRC, shall be deleted and replaced with Minnesota Rules, Chapter 1315 of the Minnesota Electrical Code. |
301 | Part IX – Referenced Standards CHAPTER 43 – REFERENCED STANDARDS AAMA ACI ACCA AFPA AGA |
302 | AHA ANSI |
303 | ASCE ASHRAE ASME ASSE |
304 | ASTM |
309 | AWPA CDA CGSB |
310 | CISPI CPSC CSA CSSB DOC EWA |
311 | FEMA FM GA HPVA ICC |
312 | NCMA NFPA NFRC NSF NSPI |
313 | RMA SAE SMACNA TPI UL |
314 | ULC WDMA |
315 | APPENDIX K – SOUND TRANSMISSION SECTION AK101 – GENERAL SECTION AK102 – AIRBORNE SOUND SECTION AK103 – STRUCTURAL-BORNE SOUND |
317 | MINNESOTA RULES, CHAPTER 4715 4715.0100 – DEFINITIONS |
322 | 4715.0200 – BASIC PLUMBING PRINCIPLES |
323 | 4715.0300 – GENERAL REGULATIONS OF PLUMBING CONSTRUCTION 4715.0310 – USE OF PUBLIC SEWER AND WATER SYSTEMS REQUIRED 4715.0320 – CONFORMANCE WITH CODE 4715.0330 – ALTERNATIVE FIXTURES, APPURTENANCES, MATERIALS, AND METHODS |
324 | 4715.0340 – HEALTH AND SAFETY |
325 | 4715.0400 – QUALITY OF MATERIALS 4715.0410 – IDENTIFICATION OF MATERIALS 4715.0420 – STANDARDS FOR PLUMBING MATERIALS |
328 | 4715.0500 – WATER SUPPLY SYSTEMS 4715.0510 – WATER SERVICE PIPE 4715.0520 – WATER DISTRIBUTION PIPE |
329 | 4715.0530 – BUILDING SEWERS 4715.0540 – STORM WATER AND YARD DRAINAGE (OUTSIDE FOUNDATION WALLS) 4715.0550 – STORM WATER OR CLEAR WATER DRAINAGE (WITHIN BUILDINGS UNDERGROUND) 4715.0560 – STORM WATER OR CLEAR WATER DRAINAGE (WITHIN BUILDINGS ABOVE GROUND) 4715.0570 – SOIL AND WASTE PIPING UNDERGROUND OR EMBEDDED 4715.0580 – SOIL AND WASTE PIPING ABOVE GROUND |
330 | 4715.0590 – VENT PIPING BELOW GROUND 4715.0600 – VENT PIPING ABOVE GROUND 4715.0610 – SPECIAL WASTES 4715.0620 – SUBSOIL DRAINS 4715.0630 – SPECIAL MATERIALS |
331 | 4715.0640 – FIXTURE MATERIALS |
332 | 4715.0700 – TIGHTNESS 4715.0710 – ASBESTOS CEMENT SEWER PIPE 4715.0720 – BITUMINIZED FIBER DRAIN PIPE JOINT 4715.0730 – BURNED LEAD JOINTS 4715.0740 – CAULKED JOINTS 4715.0750 – CEMENT MORTAR JOINTS 4715.0760 – COLD JOINT COMPOUND, TAR BASE 4715.0770 – FLARED JOINTS 4715.0780 – GASKET TYPE JOINTS 4715.0790 – HOT-POURED JOINTS |
333 | 4715.0800 – MECHANICAL JOINTS 4715.0805 – PUSH-ON JOINTS 4715.0810 – PLASTIC JOINTS |
334 | 4715.0815 – JOINTS IN CHEMICAL WASTE PIPE 4715.0820 – SOLDERED OR BRAZED JOINTS 4715.0830 – THREADED JOINTS – SCREWED JOINTS 4715.0840 – WIPED JOINTS 4715.0850 – USE OF JOINTS 4715.0860 – SPECIAL JOINTS |
335 | 4715.0870 – FLANGED FIXTURE CONNECTIONS 4715.0880 – PROHIBITED JOINTS AND CONNECTIONS 4715.0890 – INCREASERS AND REDUCERS |
336 | 4715.0900 – FIXTURE TRAP REQUIREMENTS 4715.0910 – TRAPS DESCRIBED 4715.0920 – TRAP PROTECTION 4715.0930 – SIZES OF TRAPS 4715.0940 – SLIP JOINTS AND UNIONS 4715.0950 – TRAP SEALS 4715.0960 – TRAPS PROHIBITED 4715.0970 – TRAP CLEANOUTS 4715.1000 – LOCATION |
337 | 4715.1010 – SIZE OF CLEANOUTS 4715.1020 – CLEANOUT MATERIALS 4715.1030 – CLEANOUTS TO BE ACCESSIBLE |
338 | 4715.1100 – INTERCEPTORS AND SEPERATORS REQUIRED 4715.1110 – GREASE INTERCEPTORS FOR COMMERCIAL BUILDINGS 4715.1115 – EXTERIOR GREASE INTERCEPTORS 4715.1120 – OIL AND FLAMMABLE LIQUIDS SEPARATOR |
339 | 4715.1130 – INTERCEPTORS AND SEPARATORS FOR SPECIFIC INSTALLATIONS 4715.1140 – VENTING OF INTERCEPTORS AND SEPARATORS 4715.1150 – MAINTENANCE OF INTERCEPTORS AND SEPARATORS 4715.1160 – BACKWATER VALVES |
341 | 4715.1200 – CONNECTIONS TO PLUMBING SYSTEM REQUIRED 4715.1210 – REQUIRED MINIMUM NUMBER OF FIXTURES 4715.1220 – INSTALLATION OF FIXTURES 4715.1230 – AUTOMATIC CLOTHES WASHERS 4715.1240 – BATHTUBS 4715.1250 – DISHWASHING EQUIPMENT 4715.1260 – DRINKING FOUNTAINS 4715.1300 – FLOOR DRAINS |
342 | 4715.1305 – ELEVATOR PIT DRAIN 4715.1310 – FOOD-WASTE GRINDER UNITS 4715.1320 – FLUSHING DEVICES FOR WATER CLOSETS AND URINALS 4715.1330 – FLUSH TANKS 4715.1340 – FLUSHOMETER VALVES |
343 | 4715.1350 – GARBAGE CAN WASHERS 4715.1360 – LAUNDRY TRAYS 4715.1370 – LAVATORIES 4715.1380 – SHOWERS 4715.1390 – SINKS 4715.1400 – SPECIAL PLUMBING FIXTURES |
344 | 4715.1410 – URINALS 4715.1420 – WATER CLOSETS |
345 | 4715.1430 – HANGERS AND SUPPORTS 4715.1440 – PROTECTION OF PLASTIC PIPE |
346 | 4715.1500 – INDIRECT WASTE CONNECTIONS 4715.1510 – INDIRECT WASTE PIPING 4715.1520 – CONNECTIONS FROM WATER DISTRIBUTION SYSTEM 4715.1530 – STERILIZERS 4715.1540 – POTABLE CLEAR WATER WASTES 4715.1550 – DRINKING FOUNTAINS 4715.1560 – SWIMMING POOLS 4715.1570 – METHOD OF PROVIDING AN AIR GAP 4715.1580 – METHOD OF PROVIDING AN AIR BREAK 4715.1590 – RECEPTORS OR SUMPS |
347 | 4715.1600 – CHEMICAL WASTES 4715.1610 – STEAM AND HOT WATER WASTES |
348 | 4715.1700 – WATER REQUIRED 4715.1710 – WATER SERVICE 4715.1720 – DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM 4715.1730 – SIZE OF FIXTURE BRANCH 4715.1740 – WATER PRESSURE |
349 | 4715.1750 – WATER HAMMER 4715.1760 – SUPPLY DEMAND 4715.1770 – MINIMUM PRESSURES REQUIRED IN WATER DISTRIBUTION SYSTEM 4715.1800 – WATER SUPPLYY CONTROL VALVES 4715.1810 – WATER PRESSURE BOOSTER SYSTEMS |
351 | 4715.1900 – DESIGN, MAINTENANCE, AND INSTALLATION 4715.1910 – IDENTIFICATION OF POTABLE AND NONPOTABLE WATER 4715.1911 – TOXIC MATERIALS AND USED PIPE 4715.1912 – USED WATER RETURN PROHIBITED 4715.1920 – CROSS-CONNECTION CONTROL 4715.1940 – POTABLE WATER CONNECTIONS TO HEATING OR COOLING SYSTEMS 4715.1941 – HEAT EXCHANGERS |
352 | 4715.1950 – PROHIBITED CONNECTIONS TO FIXTURES AND EQUIPMENT 4715.1960 – REFRIGERATING UNIT CONDENSERS AND COOLING JACKETS 4715.2000 – WATER OUTLETS 4715.2010 – MINIMUM REQUIRED AIR GAP |
353 | 4715.2020 – DEVICES OR ASSEMBLIES FOR THE PROTECTION OF THE POTABLE WATER SUPPLY 4715.2030 – APPROVAL OF DEVICES OR ASSEMBLIES 4715.2100 – BACKFLOW PREVENTERS 4715.2110 – TYPES OF DEVICES REQUIRED WHERE AN AIR GAP CANNOT BE PROVIDED1 |
354 | 4715.2120 – LOCATION OF BACKFLOW PREVENTERS 4715.2150 – CONNECTIONS NOT SUBJECT TO BACK PRESSURE |
355 | 4715.2160 – CONNECTIONS SUBJECT TO BACK PRESSURE 4715.2161 – INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS 4715.2162 – DOUBLE GATE VALVE ASSEMBLIES 4715.2163 – CARBONATED BEVERAGE MACHINES 4715.2165 – CHEMICAL/SOAP DISPENSING SYSTEMS 4715.2170 – BAROMETRIC LOOP 4715.2180 – HOT WATER SUPPLY SYSTEM 4715.2190 – COMBINATION WATER AND SPACE HEATING EQUIPMENT |
356 | 4715.2200 – PRESSURE RELIEF VALVES AND TEMPERATURE RELIEF VALVES DEVICES REQUIRED 4715.2210 – PRESSURE RELIEF VALVES 4715.2215 – THERMAL EXPANSION CONTROL 4715.2220 – HOT WATER STORAGE TANKS 4715.2230 – TANKLESS AND INSTANTANEOUS TYPE HEATERS 4715.2240 – ACCESS TO WATER HEATERS 4715.2250 – DISINFECTION OF POTABLE WATER SYSTEM |
357 | 4715.2280 – WATER METER INSTALLATION |
358 | 4715.2300 – LOAD ON DRAINAGE PIPING 4715.2310 – SELECTING SIZE OF DRAINAGE PIPING |
359 | 4715.2320 – MINIMUM SIZE OF SOIL AND WASTE STACKS 4715.2330 – MINIMUM SIZE OF STACK VENT OR VENT STACK 4715.2340 – PROVISION FOR FUTURE FIXTURES 4715.2350 – MINIMUM SIZE OF UNDERGROUND DRAINAGE PIPING 4715.2360 – SIZING OF OFFSETS ON DRAINAGE PIPING 4715.2370 – FIXTURE CONNECTIONS TO AN OFFSET OF MORE THAN 45 DEGREES OR AT BASE OF STACK |
360 | 4715.2400 – PITCH ON HORIZONTAL DRAINAGE PIPING 4715.2410 – CHANGE IN DIRECTION 4715.2420 – PROHIBITED FITTINGS AND CONNECTIONS 4715.2430 – BUILDING DRAINS BELOW BUILDING SEWER 4715.2440 – DESIGN OF SUMPS |
362 | 4715.2500 – SELECTING SIZE OF VENT PIPING 4715.2510 – PROTECTION OF TRAP SEALS 4715.2520 – VENT STACKS AND STACK VENTS |
363 | 4715.2530 – VENT TERMINALS 4715.2540 – VENT GRADES AND CONNECTIONS 4715.2550 – WET VENTING |
364 | 4715.2560 – STACK VENTING 4715.2570 – INDIVIDUAL FIXTURE REVENTING REQUIRED 4715.2580 – COMMON VENTS 4715.2600 – CIRCUIT AND LOOP VENTING 4715.2610 – FIXTURES BACK-TO-BACK 4715.2620 – FIXTURE VENTS |
365 | 4715.2630 – VENTS FOR FIXTURE TRAP BELOW TRAP DIP 4715.2640 – YOKE VENTS FOR STACKS OF MORE THAN FIVE BRANCH INTERVALS 4715.2650 – COMBINATION WASTE AND VENT SYSTEM 4715.2655 – ISLAND FIXTURE VENTING 4715.2660 – VENTING OF SUMPS AND SEWERS |
366 | 4715.2700 – STORM SEWER SYSTEMS 4715.2710 – SIZE OF BUILDING STORM DRAINS AND LEADERS 4715.2720 – SUBSOIL DRAINS 4715.2730 – BUILDING SUBDRAINS 4715.2740 – TRAPS ON STORM DRAINS AND LEADERS 4715.2750 – CONDUCTORS AND CONNECTIONS |
367 | 4715.2760 – ROOF AND DECK DRAINS 4715.2770 -PROVISIONS FOR EXPANSION 4715.2780 – CONTROL FLOW STORM WATER DRAINAGE FOR DEAD LEVEL ROOFS |
368 | 4715.2800 – INSPECTIONS 4715.2810 – NOTIFICATIONS 4715.2820 – METHOD OF TESTING |
369 | 4715.2830 – COVERING OF WORK 4715.2840 – DEFECTIVE WORK 4715.2850 – AIR TEST OF DEFFECTIVE PLUMBING 4715.2860 – MAINTENANCE 4715.2870 – DISINFECTION OF WATER PIPING 4715.2880 – BUILDING SEWER 4715.2890 – CERTIFICATE OF APPROVAL |
370 | 4715.3130 – PLANS AND SPECIFICATIONS 4715.3140 – EXAMINATION AND LICENSING OF PLUMBERS 4715.3150 – FEES 4715.3160 – EXPIRATION OF LICENSES |
371 | 4715.3170 – REGISTRATION OF PLUMBER’S APPRENTICE 4715.3500 – GENERAL |
372 | 4715.3600 – TOTAL DAILY REQUIREMENTS |
373 | 4715.3700 – DETERMINATION OF PEAK DEMAND |
388 | 4715.3800 – RECOMMENDED GUIDE FOR SIZING WATER SUPPLY SYSTEM |
391 | 4715.4100 – USEFUL INFORMATION |
396 | 4715.5000 – SCOPE AND APPLICABILITY 4715.5100 – DEFINITONS 4715.5200 – CONNECTION WITH WATER DISTRIBUTION SYSTEM 4715.5300 – EQUIPMENT DRAIN 4715.5400 – LOCATION 4715.5500 – REGENERATION SANITATION PROCEDURES |
397 | 4715.5600 – VARIANCE 4715.5700 – EQUIPMENT AND MATERIALS USED IN INSTALLATIONS 4715.5800 – LICENSING 4715.5900 – FEES 4715.6000 – RENEWAL |