Shopping Cart

No products in the cart.

NC ExistingBuildingCode 2015

$43.33

North Carolina State Building Code: Existing Building

Published By Publication Date Number of Pages
NC 2015 290
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2012 International Existing Building Code.

PDF Catalog

PDF Pages PDF Title
1 NORTH CAROLINA STATE BUILDING CODE: EXISTING BUILDING CODE
2 COPYRIGHT
3 NORTH CAROLINA STATE BUILDING CODE COUNCIL
4 NORTH CAROLINA DEPARTMENT OF INSURANCE
5 ACKNOWLEDGEMENTS
7 PREFACE
11 EFFECTIVE USE OF THE INTERNATIONAL EXISTING BUILDING CODE
15 TABLE OF CONTENTS
19 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
20 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF CODE OFFICIAL
SECTION 105 PERMITS
21 SECTION 106 CONSTRUCTION DOCUMENTS
SECTION 107 TEMPORARY STRUCTURES AND USES
SECTION 108 FEES
SECTION 109 INSPECTIONS
SECTION 110 CERTIFICATE OF OCCUPANCY
SECTION 111 SERVICE UTILITIES
SECTION 112 BOARD OF APPEALS
SECTION 113 VIOLATIONS
SECTION 114 STOP WORK ORDER
SECTION 115 UNSAFE BUILDINGS AND EQUIPMENT
SECTION 116 EMERGENCY MEASURES
SECTION 117 DEMOLITION
23 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
25 CHAPTER 3 COMPLIANCE METHODS
SECTION 301 COMPLIANCE METHODS
TABLE 301.1.4.1 PERFORMANCE CRITERIA FOR IBC—LEVEL SEISMIC FORCES OCCUPANCY
26 TABLE 301.1.4.2 PERFORMANCE CRITERIA FOR REDUCED IBC—LEVEL SEISMIC FORCES RISK CATEGORY
27 CHAPTER 4 PRESCRIPTIVE COMPLIANCE METHOD
SECTION 401 GENERAL
SECTION 402 ADDITIONS
28 SECTION 403 ALTERATIONS
29 SECTION 404 REPAIRS
30 SECTION 405 FIRE ESCAPES
SECTION 406 GLASS REPLACEMENT
SECTION 407 CHANGE OF OCCUPANCY
TABLE 407.1 RELATIVE OCCUPANCY HAZARD
31 SECTION 408 HISTORIC BUILDINGS
SECTION 409 MOVED STRUCTURES
SECTION 410 ACCESSIBILITY FOR EXISTING BUILDINGS
32 TABLE 410.8.5 RAMPS
35 CHAPTER 5 CLASSIFICATION OF WORK
SECTION 501 GENERAL
SECTION 502 REPAIRS
SECTION 503 ALTERATION—LEVEL 1 (Renovation)
SECTION 504 ALTERATION—LEVEL 2 (Alteration)
SECTION 505 ALTERATION—LEVEL 3 (Reconstruction)
SECTION 506 CHANGE OF OCCUPANCY
SECTION 507 ADDITIONS
SECTION 508 HISTORIC BUILDINGS
SECTION 509 RELOCATED BUILDINGS
37 CHAPTER 6 REPAIRS
SECTION 601 GENERAL
SECTION 602 BUILDING ELEMENTS AND MATERIALS
SECTION 603 FIRE PROTECTION
SECTION 604 MEANS OF EGRESS
SECTION 605 ACCESSIBILITY
SECTION 606 STRUCTURAL
SECTION 607 ELECTRICAL
38 SECTION 608 MECHANICAL
SECTION 609 PLUMBING
SECTION 610 ENERGY CONSERVATION
39 CHAPTER 7 ALTERATIONS—LEVEL 1 (Former Rehab Code designation – Renovation)
SECTION 701 GENERAL
SECTION 702 BUILDING ELEMENTS AND MATERIALS
SECTION 703 FIRE PROTECTION
SECTION 704 MEANS OF EGRESS
SECTION 705 ACCESSIBILITY (Deleted)
SECTION 706 STRUCTURAL
40 SECTION 707 ENERGY CONSERVATION
41 CHAPTER 8 ALTERATIONS—LEVEL 2 (Former Rehab Code designation – Alteration)
SECTION 801 GENERAL
SECTION 802 SPECIAL USE AND OCCUPANCY
SECTION 803 BUILDING ELEMENTS AND MATERIALS
43 SECTION 804 FIRE PROTECTION
45 SECTION 805 MEANS OF EGRESS
46 TABLE 805.2.1a,b CAPACITY PER UNIT OF EGRESS WIDTH
50 SECTION 806 ACCESSIBILITY
TABLE 806.1.4 RAMPS
51 SECTION 807 STRUCTURAL
52 SECTION 808 ELECTRICAL
53 SECTION 809 MECHANICAL
SECTION 810 PLUMBING
SECTION 811 ENERGY CONSERVATION
55 CHAPTER 9 ALTERATIONS—LEVEL 3 (Former Rehab Code designation – Reconstruction)
SECTION 901 GENERAL
SECTION 902 SPECIAL USE AND OCCUPANCY
SECTION 903 BUILDING ELEMENTS AND MATERIALS
56 SECTION 904 FIRE PROTECTION
SECTION 905 MEANS OF EGRESS
SECTION 906 ACCESSIBILITY
57 SECTION 907 STRUCTURAL
SECTION 908 ENERGY CONSERVATION
59 CHAPTER 10 CHANGE OF OCCUPANCY
SECTION 1001 GENERAL
SECTION 1002 SPECIAL USE AND OCCUPANCY
SECTION 1003 BUILDING ELEMENTS AND MATERIALS
SECTION 1004 FIRE PROTECTION
SECTION 1005 MEANS OF EGRESS
SECTION 1006 ACCESSIBILITY
SECTION 1007 STRUCTURAL
60 TABLE 1007.1 STRUCTURAL LOAD CATEGORIES
61 SECTION 1008 ELECTRICAL
SECTION 1009 MECHANICAL
SECTION 1010 PLUMBING
SECTION 1011 OTHER REQUIREMENTS
SECTION 1012 CHANGE OF OCCUPANCY CLASSIFICATION
62 TABLE 1012.2.1 HAZARD CATEGORIES AND CLASSIFICATIONS
TABLE 1012.4 MEANS OF EGRESS HAZARD CATEGORIES
63 TABLE 1012.5 HEIGHTS AND AREAS HAZARD CATEGORIES
64 TABLE 1012.6 EXPOSURE OF EXTERIOR WALLS HAZARD CATEGORIES
67 CHAPTER 11 ADDITIONS
SECTION 1101 GENERAL
SECTION 1102 HEIGHTS AND AREAS
SECTION 1103 STRUCTURAL
68 SECTION 1104 SMOKE ALARMS AND CARBON MONOXIDE ALARMS IN ONE- AND TWO-FAMILY DWELLINGS
SECTION 1105 ACCESSIBILITY
SECTION 1106 ENERGY CONSERVATION
69 CHAPTER 12 HISTORIC BUILDINGS
SECTION 1201 GENERAL
SECTION 1202 REPAIRS
70 SECTION 1203 FIRE SAFETY
SECTION 1204 ALTERATIONS
SECTION 1205 CHANGE OF OCCUPANCY
71 SECTION 1206 STRUCTURAL
73 CHAPTER 13 RELOCATED OR MOVED BUILDINGS
SECTION 1301 GENERAL
SECTION 1302 REQUIREMENTS
75 CHAPTER 14 PERFORMANCE COMPLIANCE METHODS
SECTION 1401 GENERAL
76 EQUATION 14-1
EQUATION 14-2
EQUATION 14-3
77 EQUATION 14-4
TABLE 1401.6.3 COMPARTMENTATION VALUES
TABLE 1401.6.4 SEPARATION VALUES
78 TABLE 1401.6.5 CORRIDOR WALL VALUES
TABLE 1401.6.6(1) VERTICAL OPENING PROTECTION VALUE
TABLE 1401.6.6(2) CONSTRUCTION-TYPE FACTOR
EQUATION 14-5
79 TABLE 1401.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 1401.6.9 FIRE ALARM SYSTEM VALUES
TABLE 1401.6.10 SMOKE CONTROL VALUES
80 TABLE 1401.6.11 MEANS OF EGRESS VALUESa
TABLE 1401.6.12 DEAD-END VALUES
EQUATION 14-6
81 TABLE 1401.6.14 ELEVATOR CONTROL VALUES
TABLE 1401.6.15 MEANS-OF-EGRESS EMERGENCY LIGHTING VALUES
TABLE 1401.6.16 MIXED OCCUPANCY VALUESa
82 TABLE 1401.6.17 SPRINKLER SYSTEM VALUES
TABLE 1401.6.18 STANDPIPE SYSTEM VALUES
[B] TABLE 1401.8 MANDATORY SAFETY SCORESa
83 TABLE 1401.6.19 INCIDENTAL USE AREA VALUES
84 [B] TABLE 1401.7 SUMMARY SHEET-BUILDING CODE
85 [B] TABLE 1401.9 EVALUATION FORMULASa
87 CHAPTER 15 CONSTRUCTION SAFEGUARDS
SECTION 1501 GENERAL
TABLE 1501.6 PROTECTION OF PEDESTRIANS
88 SECTION 1502 PROTECTION OF ADJOINING PROPERTY
SECTION 1503 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 1504 FIRE EXTINGUISHERS
89 SECTION 1505 MEANS OF EGRESS
SECTION 1506 STANDPIPE SYSTEMS
SECTION 1507 AUTOMATIC SPRINKLER SYSTEM
SECTION 1508 ACCESSIBILITY
SECTION 1509 WATER SUPPLY FOR FIRE PROTECTION
91 CHAPTER 16 REFERENCED STANDARDS
ASCE/SEI
ASHRAE
ASME
ASTM
92 DOC
ICC
NFPA
93 APPENDIX A: GUIDELINES FOR THE SEISMIC RETROFIT OF EXISTING BUILDINGS
CHAPTER A1 SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS
SECTION A101 PURPOSE
SECTION A102 SCOPE
SECTION A103 DEFINITIONS
SECTION A104 SYMBOLS AND NOTATIONS
94 SECTION A105 GENERAL REQUIREMENTS
95 SECTION A106 MATERIALS REQUIREMENTS
96 EQUATION A1-1
EQUATION A1-2
EQUATION A1-3
97 SECTION A107 QUALITY CONTROL
SECTION A108 DESIGN STRENGTHS
EQUATION A1-4
EQUATION A1-5
98 EQUATION A1-6
SECTION A109 ANALYSIS AND DESIGN PROCEDURE
SECTION A110 GENERAL PROCEDURE
EQUATION A1-7
SECTION A111 SPECIAL PROCEDURE
99 EQUATION A1-9
EQUATION A1-10
EQUATION A1-11
EQUATION A1-12
EQUATION A1-13
EQUATION A1-14
EQUATION A1-15
EQUATION A1-16
EQUATION A1-17
100 EQUATION A1-18
EQUATION A1-19
SECTION A112 ANALYSIS AND DESIGN
EQUATION A1-20
EQUATION A1-21
EQUATION A1-22
EQUATION A1-23
EQUATION A1-24
EQUATION A1-25
101 SECTION A113 DETAILED SYSTEM DESIGN REQUIREMENTS
102 SECTION A114 WALLS OF UNBURNED CLAY, ADOBE OR STONE MASONRY
[B] TABLE A1-A ELEMENTS REGULATED BY THIS CHAPTER
[B] TABLE A1-B ALLOWABLE VALUE OF HEIGHT-TO-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS
103 [B] TABLE A1-C HORIZONTAL FORCE FACTOR, Cp
[B] TABLE A1-D STRENGTH VALUES FOR EXISTING MATERIALS
104 [B] TABLE A1-E STRENGTH VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION
[B] TABLE A1-F MAXIMUM ALLOWABLE HEIGHT-TO-THICKNESS RATIOS FOR PARAPETS
[B] TABLE A1-G MAXIMUM HEIGHT-TO-THICKNESS RATIOS FOR ADOBE OR STONE WALLS
105 [B] FIGURE A1-1 ACCEPTABLE DIAPHRAGM SPAN
106 [B] FIGURE A1-2 ANALYSIS OF URM WALL IN-PLANE SHEAR FORCES
107 CHAPTER A2 EARTHQUAKE HAZARD REDUCTION IN EXISTING REINFORCED CONCRETE AND REINFORCED MASONRY WALL BUILDINGS WITH FLEXIBLE DIAPHRAGMS
SECTION A201 PURPOSE
SECTION A202 SCOPE
SECTION A203 DEFINITIONS
SECTION A204 SYMBOLS AND NOTATIONS
SECTION A205 GENERAL REQUIREMENTS
108 SECTION A206 ANALYSIS AND DESIGN
109 SECTION A207 MATERIALS OF CONSTRUCTION
111 CHAPTER A3 PRESCRIPTIVE PROVISIONS FOR SEISMIC STRENGTHENING OF CRIPPLE WALLS AND SILL PLATE ANCHORAGE OF LIGHT,WOOD-FRAME RESIDENTIAL BUILDINGS
SECTION A301 GENERAL
SECTION A302 DEFINITIONS
112 SECTION A303 STRUCTURAL WEAKNESSES
SECTION A304 STRENGTHENING REQUIREMENTS
115 [B] TABLE A3-A SILL PLATE ANCHORAGE AND CRIPPLE WALL BRACING
[B] TABLE A3-B SILL PLATE ANCHORAGE FOR VARIOUS LENGTHS OF SILL PLATEa,b
116 [B] FIGURE A3-1 NEW REINFORCED CONCRETE FOUNDATION SYSTEM
117 [B] FIGURE A3-2 NEW MASONRY CONCRETE FOUNDATION
118 [B] FIGURE A3-3 SILL PLATE BOLTING TO EXISTING FOUNDATION
119 [B] FIGURE A3-4A ALTERNATE SILL PLATE ANCHORING IN EXISTING FOUNDATION—WITHOUT CRIPPLE WALLS AND FLOOR FRAMING NOT PARALLEL TO FOUNDATIONS
120 [B] FIGURE A3-4B ALTERNATE SILL PLATE ANCHOR TO EXISTING FOUNDATION WITHOUT CRIPPLE WALL AND FLOOR FRAMING PARALLEL TO FOUNDATIONS
[B] FIGURE A3-4C SILL PLATE ANCHORING TO EXISTING FOUNDATION—ALTERNATE CONNECTION FOR BATTERED FOOTING
121 [B] FIGURE A3-5 CRIPPLE WALL BRACING WITH NEW WOOD STRUCTURAL PANEL ON EXTERIOR FACE OF CRIPPLE STUDS
122 [B] FIGURE A3-6 CRIPPLE WALL BRACING WITH WOOD STRUCTURAL PANEL ON INTERIOR FACE OF CRIPPLE STUDS
123 [B] FIGURE A3-7 PARTIAL CRIPPLE STUD WALL ELEVATION
124 [B] FIGURE A3-8A TYPICAL FLOOR TO CRIPPLE WALL CONNECTION (FLOOR JOISTS NOT PARALLEL TO FOUNDATIONS)
125 [B] FIGURE A3-8B TYPICAL FLOOR TO CRIPPLE WALL CONNECTION (FLOOR JOISTS PARALLEL TO FOUNDATIONS)
126 [B] FIGURE A3-8C TYPICAL FLOOR TO MUDSILL CONNECTIONS
127 [B] FIGURE A3-9 ALTERNATE FLOOR FRAMING TO CRIPPLE WALL CONNECTION
128 [B] FIGURE A3-10—FLOOR PLAN-CRIPPLE WALL BRACING LAYOUT
129 CHAPTER A4 EARTHQUAKE RISK REDUCTION IN WOOD-FRAME RESIDENTIAL BUILDINGS WITH SOFT, WEAK OR OPEN FRONT WALLS
SECTION A401 GENERAL
SECTION A402 DEFINITIONS
SECTION A403 ANALYSIS AND DESIGN
131 SECTION A404 PRESCRIPTIVE MEASURES FOR WEAK STORY
SECTION A405 MATERIALS OF CONSTRUCTION
132 SECTION A406 INFORMATION REQUIRED TO BE ON THE PLANS
SECTION A407 QUALITY CONTROL
133 CHAPTER A5 EARTHQUAKE HAZARD REDUCTION IN EXISTING CONCRETE BUILDINGS
SECTION A501 PURPOSE
SECTION A502 SCOPE
SECTION A503 GENERAL REQUIREMENTS
SECTION A504 SITE GROUND MOTION
SECTION A505 TIER 1 ANALYSIS PROCEDURE
134 SECTION A506 TIER 2 ANALYSIS PROCEDURE
135 EQUATION A5-1
SECTION A507 TIER 3 ANALYSIS PROCEDURE
137 CHAPTER A6 REFERENCED STANDARDS
ASCE/SEI
ASTM
DOC
ICC
139 APPENDIX B SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS FOR EXISTING BUILDINGS AND FACILITIES
SECTION B101 QUALIFIED HISTORICAL BUILDINGS AND FACILITIES
SECTION B102 FIXED TRANSPORTATION FACILITIES AND STATIONS
140 SECTION B103 DWELLING UNITS AND SLEEPING UNITS
SECTION B104 REFERENCED STANDARDS
141 APPENDIX C GUIDELINES FOR THE WIND RETROFIT OF EXISTING BUILDINGS (Deleted)
CHAPTER C1 GABLE END RETROFIT FOR HIGH-WIND AREAS (Deleted)
CHAPTER C2 ROOF DECK FASTENING FOR HIGH-WIND AREAS (Deleted)
143 RESOURCE A RECOMMENDED GUIDELINES ON FIRE RATINGS OF ARCHAIC MATERIALS AND ASSEMBLIES
INTRODUCTION
PURPOSE
144 1 FIRE-RELATED PERFORMANCE OF ARCHAIC MATERIALS AND ASSEMBLIES
1.1 FIRE PERFORMANCE MEASURES
145 1.2 COMBUSTIBLE CONSTRUCTION TYPES
2 BUILDING EVALUATION
2.1 PRELIMINARY EVALUATION
146 FIGURE 1 PRELIMINARY EVALUATION FIELD NOTES
147 FIGURE 2 PRELIMINARY EVALUATION WORKSHEET
148 2.2 FIRE RESISTANCE OF EXISTING BUILDING ELEMENTS
2.3 EFFECTS OF PENETRATIONS IN FIRE RESISTANT ASSEMBLIES
3 FINAL EVALUATION AND DESIGN SOLUTION
149 3.1 THE EXPERIMENTAL APPROACH
3.2 THE THEORETICAL APPROACH
HARMATHY’S TEN RULES
151 ILLUSTRATION OF HARMATHY’S RULES
EXAMPLE APPLICATION OF HARMATHY’S RULES
153 3.3 “THICKNESS DESIGN” STRATEGY
3.4 EVALUATION OF DOORS
154 FIGURE 3 MODIFICATION DETAILS
155 4 SUMMARY
157 APPENDIX
RESOURCE A TABLE OF CONTENTS
159 PURPOSE AND PROCEDURE
160 SECTION I – WALLS
FIGURE 1.1.1 MASONRY WALLS 0″ TO LESS THAN 4″ THICK
TABLE 1.1.1 MASONRY WALLS 0″ TO LESS THAN 4″ THICK
161 TABLE 1.1.1—continued MASONRY WALLS 0″ TO LESS THAN 4″ THICK
162 TABLE 1.1.1—continued MASONRY WALLS 0″ TO LESS THAN 4″ THICK
163 FIGURE 1.1.2 MASONRY WALLS 4″ TO LESS THAN 6″ THICK
TABLE 1.1.2 MASONRY WALLS 4″ TO LESS THAN 6″ THICK
164 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
165 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
166 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
167 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
168 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
169 TABLE 1.1.2—continued MASONRY WALLS 4″ TO LESS THAN 6″ THICK
170 FIGURE 1.1.3 MASONRY WALLS 6″ TO LESS THAN 8″ THICK
TABLE 1.1.3 MASONRY WALLS 6″ TO LESS THAN 8″ THICK
171 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
172 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
173 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
174 TABLE 1.1.3—continued MASONRY WALLS 6″ TO LESS THAN 8″ THICK
175 FIGURE 1.1.4 MASONRY WALLS 8″ TO LESS THAN 10″ THICK
TABLE 1.1.4 MASONRY WALLS 8″ TO LESS THAN 10″ THICK
176 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
177 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
178 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
179 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
180 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
181 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
182 TABLE 1.1.4—continued MASONRY WALLS 8″ TO LESS THAN 10″ THICK
183 FIGURE 1.1.5 MASONRY WALLS 10″ TO LESS THAN 12″ THICK
TABLE 1.1.5 MASONRY WALLS 10″ TO LESS THAN 12″ THICK
184 TABLE 1.1.5—continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK
185 TABLE 1.1.5—continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK
186 TABLE 1.1.5—continued MASONRY WALLS 10″ TO LESS THAN 12″ THICK
187 FIGURE 1.1.6 MASONRY WALLS 12″ TO LESS THAN 14″ THICK
TABLE 1.1.6 MASONRY WALLS 12″ TO LESS THAN 14″ THICK
188 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
189 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
190 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
191 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
192 TABLE 1.1.6—continued MASONRY WALLS 12″ TO LESS THAN 14″ THICK
193 FIGURE 1.1.7 MASONRY WALLS 14″ OR MORE THICK
TABLE 1.1.7 MASONRY WALLS 14″ OR MORE THICK
194 TABLE 1.1.7—continued MASONRY WALLS 14″ OR MORE THICK
195 TABLE 1.1.7—continued MASONRY WALLS 14″ OR MORE THICK
196 FIGURE 1.2.1 METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
TABLE 1.2.1 METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
197 TABLE 1.2.1—continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
198 TABLE 1.2.1—continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
199 TABLE 1.2.1—continued METAL FRAME WALLS 0″ TO LESS THAN 4″ THICK
200 FIGURE 1.2.2 METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK
TABLE 1.2.2 METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK
201 TABLE 1.2.2—continued METAL FRAME WALLS 4″ TO LESS THAN 6″ THICK
202 TABLE 1.2.3 METAL FRAME WALLS 6″ TO LESS THAN 8″ THICK
203 TABLE 1.2.4 METAL FRAME WALLS 8″ TO LESS THAN 10″ THICK
204 TABLE 1.3.1 WOOD FRAME WALLS 0″ TO LESS THAN 4″ THICK
205 FIGURE 1.3.2 WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
TABLE 1.3.2 WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
206 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
207 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
208 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
209 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
210 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
211 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
212 TABLE 1.3.2—continued WOOD FRAME WALLS 4″ TO LESS THAN 6″ THICK
213 TABLE 1.3.3 WOOD FRAME WALLS 6″ TO LESS THAN 8″ THICK
TABLE 1.4.1 MISCELLANEOUS MATERIALS WALLS 0″ TO LESS THAN 4″ THICK
214 TABLE 1.4.2 MISCELLANEOUS MATERIALS WALLS 4″ TO LESS THAN 6″ THICK
215 FIGURE 1.5.1 FINISH RATINGS—INORGANIC MATERIALS
TABLE 1.5.1 FINISH RATINGS—INORGANIC MATERIALS
216 TABLE 1.5.1—continued FINISH RATINGS—INORGANIC MATERIALS
TABLE 1.5.2 FINISH RATINGS—ORGANIC MATERIALS
217 SECTION II COLUMNS
TABLE 2.1.1 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 0″ TO LESS THAN 6″
218 FIGURE 2.1.2 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
TABLE 2.1.2 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
219 TABLE 2.1.2—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
220 TABLE 2.1.2—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 10″ TO LESS THAN 12″
221 TABLE 2.1.3 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 12″ TO LESS THAN 14″
222 TABLE 2.1.4 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 14″ TO LESS THAN 16″
223 FIGURE 2.1.5 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″
TABLE 2.1.5 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18″
224 TABLE 2.1.5—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 16″ TO LESS THAN 18
225 TABLE 2.1.6 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 18″ TO LESS THAN 20″
226 FIGURE 2.1.7 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22
TABLE 2.1.7 REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″
227 TABLE 2.1.7—continued REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 20″ TO LESS THAN 22″
TABLE 2.1.8 HEXAGONAL REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 12″ TO LESS THAN 14″
228 TABLE 2.1.9 HEXAGONAL REINFORCED CONCRETE COLUMNS MINIMUM DIMENSION 14″ TO LESS THAN 16″
TABLE 2.1.10 HEXAGONAL REINFORCED CONCRETE COLUMNS DIAMETER—16″ TO LESS THAN 18″
TABLE 2.1.11 HEXAGONAL REINFORCED CONCRETE COLUMNS DIAMETER—20″ TO LESS THAN 22″
229 TABLE 2.2 ROUND CAST IRON COLUMNS
230 FIGURE 2.3 STEEL COLUMNS-GYPSUM ENCASEMENTS
TABLE 2.3 STEEL COLUMNS—GYPSUM ENCASEMENTS
231 TABLE 2.3—continued STEEL COLUMNS—GYPSUM ENCASEMENTS
TABLE 2.4 TIMBER COLUMNS MINIMUM DIMENSION
TABLE 2.5.1.1 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION LESS THAN 6″
232 TABLE 2.5.1.2 STEEL COLUMNS—CONCRETE ENCASEMENTS 6″ TO LESS THAN 8″ THICK
233 FIGURE 2.5.1.3 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
TABLE 2.5.1.3 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
234 TABLE 2.5.1.3—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
235 FIGURE 2.5.1.4 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
TABLE 2.5.1.4 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
236 TABLE 2.5.1.4—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
237 TABLE 2.5.1.4—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
238 TABLE 2.5.1.4—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
239 FIGURE 2.5.1.5 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
TABLE 2.5.1.5 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
240 TABLE 2.5.1.5 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
241 FIGURE 2.5.1.6 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
TABLE 2.5.1.6 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
242 TABLE 2.5.1.6—continued STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16″
243 TABLE 2.5.1.7 STEEL COLUMNS—CONCRETE ENCASEMENTS MINIMUM DIMENSION 16″ TO LESS THAN 18″
TABLE 2.5.2.1 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
244 TABLE 2.5.2.2 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
TABLE 2.5.2.3 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16
TABLE 2.5.2.3 STEEL COLUMNS—BRICK AND BLOCK ENCASEMENTS MINIMUM DIMENSION 14″ TO LESS THAN 16
245 TABLE 2.5.3.1 STEEL COLUMNS—PLASTER ENCASEMENTS MINIMUM DIMENSION 6″ TO LESS THAN 8″
TABLE 2.5.3.2 STEEL COLUMNS—PLASTER ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10
TABLE 2.5.4.1 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 6″ TO LESS THAN 8″
246 TABLE 2.5.4.2 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 8″ TO LESS THAN 10″
TABLE 2.5.4.3 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 10″ TO LESS THAN 12″
TABLE 2.5.4.4 STEEL COLUMNS—MISCELLANEOUS ENCASEMENTS MINIMUM DIMENSION 12″ TO LESS THAN 14″
247 SECTION III FLOOR/CEILING ASSEMBLIES
FIGURE 3.1 FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
TABLE 3.1 FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
248 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
249 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
250 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
251 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
252 TABLE 3.1—continued FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
253 FIGURE 3.2 FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
TABLE 3.2 FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
254 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
255 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
256 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
257 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
258 TABLE 3.2—continued FLOOR/CEILING ASSEMBLIES—STEEL STRUCTURAL ELEMENTS
259 FIGURE 3.3 FLOOR/CEILING ASSEMBLIES—WOOD JOIST
TABLE 3.3 FLOOR/CEILING ASSEMBLIES—WOOD JOIST
260 TABLE 3.3—continued FLOOR/CEILING ASSEMBLIES—WOOD JOIST
261 TABLE 3.3—continued FLOOR/CEILING ASSEMBLIES—WOOD JOIST
262 TABLE 3.3—continued FLOOR/CEILING ASSEMBLIES—WOOD JOIST
263 FIGURE 3.4 FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
TABLE 3.4 FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
264 TABLE 3.4—continued FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
265 TABLE 3.4—continued FLOOR/CEILING ASSEMBLIES-HOLLOW CLAY TILE WITH REINFORCED CONCRETE
266 SECTION IV BEAMS
TABLE 4.1.1 REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″
267 TABLE 4.1.1—continued REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″
268 TABLE 4.1.1—continued REINFORCED CONCRETE BEAMS DEPTH 10″ TO LESS THAN 12″
269 TABLE 4.1.2 REINFORCED CONCRETE BEAMS DEPTH 12″ TO LESS THAN 14″
270 TABLE 4.1.2—continued REINFORCED CONCRETE BEAMS DEPTH 12″ TO LESS THAN 14″
271 TABLE 4.1.3 REINFORCED CONCRETE BEAMS DEPTH 14″ TO LESS THAN 16″
272 TABLE 4.2.1 REINFORCED CONCRETE BEAMS—UNPROTECTED DEPTH 10″ TO LESS THAN 12″
TABLE 4.2.2 STEEL BEAMS—CONCRETE PROTECTION DEPTH 10″ TO LESS THAN 12″
273 SECTION V DOORS
FIGURE 5.1 RESISTANCE OF DOORS TO FIRE EXPOSURE
TABLE 5.1 RESISTANCE OF DOORS TO FIRE EXPOSURE
274 TABLE 5.1—continued RESISTANCE OF DOORS TO FIRE EXPOSURE
275 TABLE 5.1—continued RESISTANCE OF DOORS TO FIRE EXPOSURE
276 BIBLIOGRAPHY
283 INDEX
287 ICC PLAN REVIEW SERVICES
288 SPECIAL INSPECTION PROGRAM FOR BUILDING DEPARTMENTS
289 GET IMMEDIATE DOWNLOADS OF THE STANDARDS
290 ICC MEMBERSHIP
NC ExistingBuildingCode 2015
$43.33