Shopping Cart

No products in the cart.

NC FuelGasCode 2018 1stPrint

$59.04

North Carolina State Building Code: Fuel Gas Code 2018

Published By Publication Date Number of Pages
NC 2018 195
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2015 International Fuel Gas Code.

PDF Catalog

PDF Pages PDF Title
1 2018 NORTH CAROLINA STATE BUILDING CODE: FUEL GAS CODE
2 2018 NORTH CAROLINA STATE BUILDING CODE: FUEL GAS CODE TITLE PAGE
3 COPYRIGHT
4 NORTH CAROLINA STATE BUILDING CODE COUNCIL DECEMBER 12, 2017
5 NORTH CAROLINA DEPARTMENT OF INSURANCE
6 ACKNOWLEDGEMENTS
8 PREFACE
12 EFFECTIVE USE OF THE INTERNATIONAL FUEL GAS CODE
14 LEGISLATION
16 TABLE OF CONTENTS
18 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 (IFGC) GENERAL
19 SECTION 102 (IFGC) APPLICABILITY
20 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 (IFGC) DEPARTMENT OF INSPECTION
SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 (IFGC) APPROVAL
SECTION 106 (IFGC) PERMITS
SECTION 107 (IFGC) INSPECTIONS AND TESTING
21 SECTION 108 (IFGC) VIOLATIONS
SECTION 109 (IFGC) MEANS OF APPEAL
SECTION 110 (IFGC) TEMPORARY EQUIPMENT, SYSTEMS AND USES
22 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
32 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
33 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
34 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 3-1
EQUATION 3-2
35 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
36 FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2)
37 SECTION 305 (IFGC) INSTALLATION
38 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
40 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
41 TABLE 308.2a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
42 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
43 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
SECTION 311 CARBON MONOXIDE ALARMS
46 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
EQUATION 4-1
47 EQUATION 4-2
TABLE 402.4Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
48 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
49 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
50 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
51 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
52 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
53 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
54 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
55 TABLE 402.4(8) SEMIRIGID COPPER TUBING
56 TABLE 402.4(9) SEMIRIGID COPPER TUBING
57 TABLE 402.4(10) SEMIRIGID COPPER TUBING
58 TABLE 402.4(11) SEMIRIGID COPPER TUBING
59 TABLE 402.4(12) SEMIRIGID COPPER TUBING
60 TABLE 402.4(13) SEMIRIGID COPPER TUBING
61 TABLE 402.4(14) SEMIRIGID COPPER TUBING
62 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
63 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
64 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
65 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
66 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
67 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
68 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
69 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
70 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
71 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
72 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
73 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
74 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
75 TABLE 402.4(29) SEMIRIGID COPPER TUBING
76 TABLE 402.4(30) SEMIRIGID COPPER TUBING
77 TABLE 402.4(31) SEMIRIGID COPPER TUBING
78 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
79 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
80 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
81 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
82 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
83 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
84 TABLE 402.4(38) POLYETHYLENE PLASTIC TUBING
85 TABLE 402.4(39) POLYETHYLENE PLASTIC TUBING
86 SECTION 403 (IFGS) PIPING MATERIALS
87 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
88 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
90 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
92 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
93 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
SECTION 409 (IFGC) SHUTOFF VALVES
94 FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
SECTION 410 (IFGC) FLOW CONTROLS
95 SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
96 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
98 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
100 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
101 SECTION 502 (IFGC) VENTS
102 SECTION 503 (IFGS) VENTING OF APPLIANCES
103 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
104 FIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS ALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT APPLIANCES
105 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
106 FIGURE 503.6.10.1 PLAN VIEW OF PRACTICAL SEPARATION METHOD FOR MULTISTORY GAS VENTING
109 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
110 TABLE 503.10.5 CLEARANCES FOR CONNECTORSa
111 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
114 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
116 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
117 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
118 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
119 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
120 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
121 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
122 TABLE 504.2(2)-continued TYPE B DOUBLE-WALL GAS VENT
123 TABLE 504.2(3) MASONRY CHIMNEY
124 TABLE 504.2(3)—continued MASONRY CHIMNEY
125 TABLE 504.2(4) MASONRY CHIMNEY
126 TABLE 504.2(4)—continued MASONRY CHIMNEY
127 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
128 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
129 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
130 TABLE 504.3(1)-continued TYPE B DOUBLE-WALL VENT
131 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
132 TABLE 504.3(3) MASONRY CHIMNEY
133 TABLE 504.3(4) MASONRY CHIMNEY
134 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
135 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY-continued
136 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
138 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
139 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
140 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
141 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
142 SECTION 615 (IFGC) SAUNA HEATERS
143 SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
144 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
145 SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
146 SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
147 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
148 SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
150 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
151 SECTION 704 (IFGC) PIPING, USE AND HANDLING
152 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
153 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
154 SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
156 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
157 ASME
ASTM
CGA
158 CSA
DOTn
ICC
MSS
159 NFPA
UL
160 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
161 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
162 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
163 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
165 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAM
A.4 USE OF SIZING EQUATIONS
166 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
167 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
168 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
169 FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
172 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
173 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
174 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
175 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
176 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
177 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
179 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
180 FIGURE B-19
182 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
184 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
185 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
186 D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
187 D.6 APPLIANCE-SPECIFIC INSPECTIONS
189 TABLE D.6 CO THRESHOLDS
190 INDEX
194 DISCOVER THE ICC ASSESSMENT CENTER, FEATURING PRONTO™
195 ICC EVALUATION SERVICE
NC FuelGasCode 2018 1stPrint