Shopping Cart

No products in the cart.

NC PlumbingCode 2018 1stPrint

$59.04

North Carolina State Building Code: Plumbing Code 2018

Published By Publication Date Number of Pages
NC 2018 181
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2015 International Plumbing Code.

PDF Catalog

PDF Pages PDF Title
1 2018 NORTH CAROLINA STATE BUILDING CODE: PLUMBING CODE
2 2018 NORTH CAROLINA STATE BUILDING CODE: PLUMBING CODE TITLE PAGE
3 COPYRIGHT
4 NORTH CAROLINA STATE BUILDING CODE COUNCIL DECEMBER 12, 2017
5 NORTH CAROLINA DEPARTMENT OF INSURANCE
6 ACKNOWLEDGEMENTS
8 PREFACE
10 EFFECTIVE USE OF THE INTERNATIONAL PLUMBING CODE
14 LEGISLATION
16 TABLE OF CONTENTS
20 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
21 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF PLUMBING INSPECTION
SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 APPROVAL
22 SECTION 106 PERMITS
SECTION 107 INSPECTIONS AND TESTING
SECTION 108 VIOLATIONS
SECTION 109 MEANS OF APPEAL
SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES
24 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
34 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION 303 MATERIALS
SECTION 304 RODENTPROOFING
35 SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
36 SECTION 307 STRUCTURAL SAFETY
SECTION 308 PIPING SUPPORT
37 TABLE 308.5 HANGER SPACING
SECTION 309 FLOOD HAZARD RESISTANCE
SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
38 SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
39 SECTION 313 EQUIPMENT EFFICIENCIES
SECTION 314 CONDENSATE DISPOSAL
SECTION 315 PENETRATIONS
SECTION 316 ALTERNATIVE ENGINEERED DESIGN
SECTION 317 CARBON MONOXIDE ALARMS
42 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILIT
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa, p (See Sections 403.1.1 and 403.2)
43 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa, p (See Sections 403.1.1 and 403.2)
44 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
45 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
48 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
SECTION 405 INSTALLATION OF FIXTURES
49 SECTION 406 AUTOMATIC CLOTHES WASHERS
SECTION 407 BATHTUBS
SECTION 408 BIDETS
50 SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
SECTION 412 FLOOR AND TRENCH DRAINS
SECTION 413 FOOD WASTE DISPOSER UNITS
51 SECTION 414 GARBAGE CAN WASHERS
SECTION 415 LAUNDRY TRAYS
SECTION 416 LAVATORIES
SECTION 417 SHOWERS
52 TABLE 417.4 PREFABRICATED SHOWER RECEPTOR STANDARDS MATERIALS STANDARDS
SECTION 418 SINKS
SECTION 419 URINALS
53 SECTION 420 WATER CLOSETS
SECTION 421 WHIRLPOOL BATHTUBS
SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT
54 SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS
55 SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 427 FLOOR SINKS
56 CHAPTER 5 WATER HEATERS
SECTION 501 GENERAL
57 SECTION 502 INSTALLATION
SECTION 503 CONNECTIONS
58 SECTION 504 SAFETY DEVICES
59 SECTION 505 INSULATION
60 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
SECTION 603 WATER SERVICE
SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
61 TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
62 TABLE 604.5—continued MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
TABLE 604.10.1 MANIFOLD SIZING
SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
63 TABLE 605.3 WATER SERVICE PIPE
64 TABLE 605.4 WATER DISTRIBUTION PIPE
65 TABLE 605.5 PIPE FITTINGS
TABLE 605.7 VALVES
66 TABLE 605.8 MANUFACTURED PIPE NIPPLES
69 SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
70 TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
71 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
72 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
73 FIGURE 608.8.1 PICTOGRAPH—DO NOT DRINK
TABLE 608.8.2.2 SIZE OF PIPE IDENTIFICATION
74 TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS
76 SECTION 609 HEALTH CARE PLUMBING
SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
SECTION 611 DRINKING WATER TREATMENT UNITS
SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
77 SECTION 614 PARTIAL FIRE SPRINKLER PROTECTION IN ONE- AND TWO-FAMILY DWELLINGS
SECTION 615 FULL FIRE SPRINKLER PROTECTION IN ONE- AND TWO-FAMILY DWELLINGS
78 CHAPTER 7 SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
79 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
80 TABLE 702.4 PIPE FITTINGS
SECTION 703 BUILDING SEWER
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
81 SECTION 705 JOINTS
83 TABLE 705.18 CAULKING FERRULE SPECIFICATIONS
TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
84 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION 708 CLEANOUTS
85 SECTION 709 FIXTURE UNITS
86 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
87 TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION 710 DRAINAGE SYSTEM SIZING
TABLE 710.1(1) BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa, f
88 SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
SECTION 712 SUMPS AND EJECTORS
89 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
SECTION 713 HEALTH CARE PLUMBING
90 TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS (Number of Connections of Various Sizes
Permitted to Various-sized Sterilizer Vent Stacks)
TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS (Number of Connections of Various Sizes
Permitted To Various-sized Vent Stacks)
SECTION 714 COMPUTERIZED DRAINAGE DESIGN
SECTION 715 BACKWATER VALVES
91 SECTION 716 VACUUM DRAINAGE SYSTEMS
SECTION 717 REPLACEMENT OF UNDERGROUND SEWERS BY PIPE-BURSTING METHODS
92 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
93 SECTION 803 SPECIAL WASTES
SECTION 804 MATERIALS, JOINTS AND CONNECTIONS
94 CHAPTER 9 VENTS
SECTION 901 GENERAL
SECTION 902 MATERIALS
SECTION 903 VENT TERMINALS
SECTION 904 OUTDOOR VENT EXTENSIONS
95 SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 VENT PIPE SIZING
96 TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
97 TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS
SECTION 907 VENTS FOR STACK OFFSETS
SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
SECTION 909 FIXTURE VENTS
TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
98 SECTION 910 INDIVIDUAL VENT
SECTION 911 COMMON VENT
TABLE 911.3 COMMON VENT SIZES
SECTION 912 WET VENTING
TABLE 912.3 WET VENT SIZE
SECTION 913 WASTE STACK VENT
99 TABLE 913.4 WASTE STACK VENT SIZE
SECTION 914 CIRCUIT VENTING
SECTION 915 COMBINATION WASTE AND VENT SYSTEM
100 SECTION 916 ISLAND FIXTURE VENTING
SECTION 917 SINGLE STACK VENT SYSTEM (SOVENT)
SECTION 918 AIR ADMITTANCE VALVES
101 SECTION 919 ENGINEERED VENT SYSTEMS
SECTION 920 COMPUTERIZED VENT DESIGN
102 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
103 SECTION 1003 INTERCEPTORS AND SEPARATORS
TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORSa
104 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
106 CHAPTER 11 STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
TABLE 1102.5 SUBSOIL DRAIN PIPE
107 TABLE 1102.7 PIPE FITTING
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
108 FIGURE 1106.1(a) 100-YEAR, 1-HOUR RAINFALL (INCHES/HOUR) NORTH CAROLINA FOR PRIMARY ROOF DRAINS
FIGURE 1106.1(b) 100-YEAR, 15-MINUTE RAINFALL (INCHES/HOUR) NORTH CAROLINA FOR SECONDARY ROOF DRAINS
109 TABLE 1106.2(1) SIZE OF CIRCULAR CONDUCTORS AND LEADERS
TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS
110 TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPINGa
111 FIGURE 1106.5 SIZE OF SCUPPERS
112 TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERSa
113 SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS
SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS
SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER
SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
SECTION 1113 SUMPS AND PUMPING SYSTEMS
114 SECTION 1114 VALUES FOR CONTINUOUS FLOW
116 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS
118 CHAPTER 13 NONPOTABLE WATER SYSTEMS
SECTION 1301 GENERAL
FIGURE 1301.3 PICTOGRAPH—DO NOT DRINK
119 TABLE 1301.6.2.2 SIZE OF PIPE IDENTIFICATION
121 SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS
122 TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS
123 SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS
124 TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS
125 SECTION 1304 RECLAIMED WATER SYSTEMS
126 CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
128 CHAPTER 15 REFERENCED STANDARDS
ANSI
AHRI
API
ASME
130 ASPE
ASSE
131 ASTM
134 AWS
AWWA
135 CISPI
CSA
136 IAPMO
ICC
137 ISEA
MSS
NFPA
NSF
138 PDI
UL
140 APPENDIX A PLUMBING PERMIT FEE SCHEDULE
142 APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES
144 APPENDIX C STRUCTURAL SAFETY
SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
146 APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES
148 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
152 TABLE E.1
TABLE E.2
153 FIGURE E103.3(1) EXAMPLE-SIZING
154 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
155 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
156 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
157 TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH
158 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
159 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING)
160 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING)
161 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING)
162 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
163 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
164 FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa
165 SECTION E201 SELECTION OF PIPE SIZE
SECTION E202 DETERMINATION OF PIPE VOLUMES
166 TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
167 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
168 TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
170 INDEX
180 TURN TO ICC FOR YOUR GO-TO CODE RESOURCES
181 DISCOVER THE ICC ASSESSMENT CENTER, FEATURING PRONTO™
NC PlumbingCode 2018 1stPrint
$59.04