NC ResidentialCode 2012
$55.25
North Carolina Residential Code, 3rd Printing
Published By | Publication Date | Number of Pages |
NC | 2012 | 966 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2012 NORTH CAROLINA STATE BUILDING CODE: RESIDENTIAL CODE (2009 IRC® WITH NORTH CAROLINA AMENDMENTS) |
2 | COPYRIGHT |
3 | NORTH CAROLINA STATE BUILDING CODE COUNCIL |
4 | NORTH CAROLINA DEPARTMENT OF INSURANCE |
5 | PREFACE |
7 | EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE |
11 | TABLE OF CONTENTS |
15 | PART I—ADMINISTRATIVE CHAPTER 1 SCOPE AND ADMINISTRATION PART I—SCOPE AND APPLICATION SECTION R101 GENERAL SECTION R102 APPLICABILITY |
16 | PART II—ADMINISTRATION AND ENFORCEMENT SECTION R103 DEPARTMENT OF BUILDING SAFETY SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIAL SECTION R105 PERMITS SECTION R106 CONSTRUCTION DOCUMENTS SECTION R107 TEMPORARY STRUCTURES AND USES SECTION R108 FEES SECTION R109 INSPECTIONS SECTION R110 CERTIFICATE OF OCCUPANCY SECTION R111 SERVICE UTILITIES SECTION R112 BOARD OF APPEALS SECTION R113 VIOLATIONS SECTION R114 STOP WORK ORDER |
17 | PART II—DEFINITIONS CHAPTER 2 DEFINITIONS SECTION R201 GENERAL SECTION R202 DEFINITIONS |
33 | PART III—BUILDING PLANNING AND CONSTRUCTION CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA |
34 | TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA FIGURE R301.2(1) ISOLINES OF THE 97 1/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES ( F) |
35 | TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (PSF) |
36 | FIGURE R301.2(2) INTERNATIONAL RESIDENTIAL CODE NORTH CAROLINA AMENDMENTS SEISMIC DESIGN CATEGORIES SITE CLASS D |
37 | FIGURE R301.2(2)—CONTINUED COUNTIES IN SEISMIC DESIGN CATEGORY C TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) |
38 | FIGURE R301.2(4) INTERNATIONAL RESIDENTIAL CODE NORTH CAROLINA AMENDMENTS BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL |
39 | FIGURE R301.2(4)—CONTINUED BASIC DESIGN WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL FIGURE R301.2(4)—CONTINUED BASIC DESIGN WIND VELOCITIES FOR MOUNTAIN REGIONS |
40 | TABLE R301.2(4)—CONTINUED DESIGN PRESSURES FOR DOORS AND WINDOWS POSITIVE AND NEGATIVE IN PSF FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES |
41 | FIGURE R301.2(5) GROUND SNOW LOADS, PG, FOR THE UNITED STATES (LB/FT2) |
42 | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSA, TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDS |
43 | TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADA |
45 | TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (IN POUNDS PER SQUARE FOOT) |
46 | TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS SECTION R302 FIRE-RESISTANT CONSTRUCTION |
47 | TABLE R302.1 EXTERIOR WALLS |
49 | TABLE R302.6 DWELLING/GARAGE SEPARATION |
51 | SECTION R303 LIGHT, VENTILATION AND HEATING |
52 | SECTION R304 MINIMUM ROOM AREAS SECTION R305 CEILING HEIGHT |
53 | SECTION R306 SANITATION SECTION R307 TOILET, BATH AND SHOWER SPACES FIGURE R307.1 MINIMUM FIXTURE CLEARANCES SECTION R308 GLAZING |
54 | TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201 TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1 |
56 | SECTION R309 GARAGES AND CARPORTS SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS |
57 | SECTION R311 MEANS OF EGRESS |
60 | SECTION R312 GUARDS SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS SECTION R314 SMOKE ALARMS |
61 | SECTION R315 CARBON MONOXIDE ALARMS SECTION R316 FOAM PLASTIC |
63 | SECTION R317 PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY |
65 | SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES SECTION R319 SITE ADDRESS SECTION R320 ACCESSIBILITY SECTION R321 ELEVATORS AND PLATFORM LIFTS |
66 | SECTION R322 FLOOD-RESISTANT CONSTRUCTION |
69 | SECTION R323 STORM SHELTERS |
71 | CHAPTER 4 FOUNDATIONS SECTION R401 GENERAL TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSA SECTION R402 MATERIALS |
72 | TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SECTION R403 FOOTINGS |
73 | TABLE R403.1 MINIMUM WIDTH OF CONCRETE, PRECAST OR MASONRY FOOTINGS (INCHES) TABLE R403.1A PIER1 AND FOOTING2 SIZES FOR SUPPORT OF GIRDERS |
74 | FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS |
75 | FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION |
76 | FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION |
78 | TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (INCHES) FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING |
79 | SECTION R404 FOUNDATION AND RETAINING WALLS |
80 | TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS |
81 | TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE D > 5 INCHES |
82 | TABLE R404.1.1(3) 10-INCH FOUNDATION WALLS WITH REINFORCING WHERE D > 6.75 INCHES |
83 | TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE D > 8.75 INCHES |
84 | TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLS TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS |
85 | TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 MM) NOMINAL FLAT CONCRETE BASEMENT WALLS |
86 | TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS |
87 | TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS |
88 | TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS |
89 | TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 MM) SCREEN-GRID BASEMENT WALLS |
90 | TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLS |
91 | TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL |
92 | TABLE R404.1.2(9)—CONTINUED MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 PCF EQUIVALENT-FLUID WEIGHT SOIL PRESSURE) |
96 | SECTION R405 FOUNDATION DRAINAGE |
97 | TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM |
98 | SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING SECTION R407 COLUMNS |
99 | SECTION R408 UNDER-FLOOR SPACE |
100 | SECTION R409 CLOSED CRAWL SPACES |
103 | CHAPTER 5 FLOORS SECTION R501 GENERAL SECTION R502 WOOD FLOOR FRAMING |
104 | FIGURE R502.2 FLOOR CONSTRUCTION |
106 | SECTION R503 FLOOR SHEATHING TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING |
107 | TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL SLEEPING AREAS, LIVE LOAD = 30 PSF, L/Δ = 360)a |
108 | TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL LIVING AREAS, LIVE LOAD = 40 PSF, L/Δ = 360) |
109 | TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY (Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf) TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY |
110 | TABLE R502.5(1) GIRDER SPANS AND HEADER SPANS FOR EXTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIR AND THE REQUIRED NUMBER OF JACK STUDS |
111 | TABLE R502.5(1)—CONTINUED GIRDER SPANS AND HEADER SPANS FOR EXTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE FIR AND REQUIRED NUMBER OF JACK STUDS |
112 | TABLE R502.5(2) GIRDER SPANS AND HEADER SPANS FOR INTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIR AND REQUIRED NUMBER OF JACK STUDS |
113 | FIGURE R502.8 CUTTING, NOTCHING AND DRILLING FIGURE R502.8(a) ACCEPTABLE LOCATION OF 3 5/8 -inch DIAMETER HOLE IN 2 x 10 JOIST |
114 | TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT |
115 | TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENT SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND) SECTION R505 STEEL FLOOR FRAMING |
116 | FIGURE R505.1.2 IN-LINE FRAMING |
117 | FIGURE R505.2(1) C-SHAPED SECTION FIGURE R505.2(2) TRACK SECTION TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS |
118 | TABLE R505.2.4 SCREW SUBSTITUTION FACTOR FIGURE R505.2.5.1 FLOOR JOIST WEB HOLES |
119 | FIGURE R505.2.5.3 WEB HOLE PATCH |
120 | TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS FIGURE 505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION |
121 | TABLE R505.3.1(2) FLOOR FASTENING SCHEDULE FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION |
122 | FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION FIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION |
123 | FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION |
124 | FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL |
125 | FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS |
126 | TABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE SPANS 33 KSI STEEL FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID) |
127 | TABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANS 33 KSI STEEL FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP) |
128 | TABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANS 50 KSI STEEL |
129 | FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS TABLE R505.3.4(1) CLIP ANGLE BEARING STIFFENERS (20 PSF EQUIVALENT SNOW LOAD) |
130 | TABLE R505.3.4(2) CLIP ANGLE BEARING STIFFENERS (30 PSF EQUIVALENT SNOW LOAD) FIGURE R505.3.4(2) BEARING STIFFENER |
131 | TABLE R505.3.4(3) CLIP ANGLE BEARING STIFFENERS (50 PSF EQUIVALENT SNOW LOAD) TABLE R505.3.4(4) CLIP ANGLE BEARING STIFFENERS (70 PSF EQUIVALENT SNOW LOAD) |
132 | SECTION R506 CONCRETE FLOORS (ON GROUND) |
133 | FIGURE R505.3.7 TRACK SPLICE FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION: 6-FOOT FLOOR OPENING |
134 | FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION: 8-FOOT FLOOR OPENING FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING |
135 | FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING |
137 | CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL TABLE R601.3.1 CLASS III VAPOR RETARDERS |
138 | SECTION R602 WOOD WALL FRAMING |
140 | TABLE R602.3(1) WALL FRAMING |
141 | TABLE R602.3(1)—CONTINUED WALL FRAMING |
142 | TABLE R602.3(1)—CONTINUED CEILING AND ROOF FRAMING |
143 | TABLE R602.3(1)—CONTINUED CEILING AND ROOF FRAMING |
144 | TABLE R602.3(1)—CONTINUED FLOOR FRAMING |
145 | TABLE R602.3(1)—CONTINUED FLOOR FRAMING a |
146 | TABLE R602.3(1)—CONTINUED FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
147 | TABLE R602.3(1A) NOMINAL DIMENSIONS OF NAILS LISTED IN TABLE R602.3.1 |
148 | TABLE R602.3(2) ALTERNATE ATTACHMENTS |
149 | TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS |
150 | FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING |
151 | FIGURE R602.3(2) FRAMING DETAILS |
152 | TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C, D0,D1,D2 |
153 | TABLE R602.3.1—CONTINUED MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C, D0,D1,D2 |
154 | FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS |
155 | FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS |
156 | FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING |
157 | TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERS FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION |
159 | TABLE R602.10.1.2(1) BRACING REQUIREMENTS BASED ON WIND SPEED (as a function of braced wall line spacing) |
160 | TABLE R602.10.1.2(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED (as a function of braced wall line spacing) |
161 | TABLE R602.10.1.2(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED (as a function of braced wall line spacing) |
162 | TABLE R602.10.1.2(2) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY (AS A FUNCTION OF BRACED WALL LINE LENGTH) |
163 | TABLE R602.10.1.2(2)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY (AS A FUNCTION OF BRACED WALL LINE LENGTH) TABLE R602.10.1.2(3) ADJUSTMENT FACTORS TO THE LENGTH OF REQUIRED SEISMIC WALL BRACING |
164 | FIGURE R602.10.1.3 ANGLED CORNERS FIGURE R602.10.1.4(1) BRACED WALL PANELS AND BRACED WALL LINES |
165 | FIGURE R602.10.1.4(2) BRACED WALL PANEL END DISTANCE REQUIREMENTS (SDC A, B AND C) FIGURE R602.10.1.4(3) OFFSETS PERMITTED FOR BRACED WALL LINES |
166 | FIGURE R602.10.1.4(4) BRACED WALL LINE SPACING FIGURE R602.10.1.4.1 BRACED WALL PANELS AT ENDS OF BRACED WALL LINES IN SEISMIC DESIGN CATEGORIES D0, D1 AND D2 TABLE R602.10.1.5 ADJUSTMENTS OF BRACING LENGTH FOR BRACED WALL LINE SPACING GREATER THAN 25 FEET |
167 | TABLE R602.10.2 INTERMITTENT BRACING METHODS |
169 | TABLE R602.10.3 EFFECTIVE LENGTHS FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH (BRACE METHODS DWB, WSP, SFB, PBS, PCP AND HPS TABLE R602.10.3.1 MINIMUM LENGTH REQUIREMENTS FOR BRACED WALL PANELS TABLE R602.10.3.2 MINIMUM LENGTH REQUIREMENTS AND HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS |
170 | FIGURE R602.10.3.2 ALTERNATE BRACED WALL PANEL FIGURE R602.10.3.3 METHOD PFH: PORTAL FRAME WITH HOLD-DOWNS |
171 | FIGURE R602.10.3.4 METHOD PFG PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C |
172 | TABLE R602.10.4.1 CONTINUOUS SHEATHING METHODS |
173 | FIGURE R602.10.4.1.1 METHOD CS-PF: CONTINUOUS PORTAL FRAME PANEL CONSTRUCTION |
174 | TABLE R602.10.4.1.1 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO 6:1 ASPECT RATIO WALLSA, FIGURE R602.10.4.2 BRACED WALL PANELS WITH CONTINUOUS SHEATHING |
175 | TABLE R602.10.4.2 LENGTH REQUIREMENTS FOR BRACED WALL PANELS WITH CONTINUOUS SHEATHINGA, |
176 | FIGURE R602.10.4.4(1) TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS SHEATHING |
177 | FIGURE R602.10.4.4(2) BRACED WALL LINE WITH CONTINUOUS SHEATHING WITH CORNER RETURN PANEL FIGURE R602.10.4.4(3) BRACED WALL LINE WITH CONTINUOUS SHEATHING WITHOUT CORNER RETURN PANEL |
178 | FIGURE R602.10.4.4(4) BRACED WALL LINE WITH CONTINUOUS SHEATHING FIRST BRACED WALL PANEL AWAY FROM END OF WALL LINE WITHOUT TIE FIGURE R602.10.4.4(5) BRACED WALL LINE WITH CONTINUOUS SHEATHING—FIRST BRACED WALL PANEL AWAY FROM END OF WALL LINE WITH HOLD-DOWN |
179 | TABLE R602.10.5.2 MINIMUM LENGTH REQUIREMENTS FOR STRUCTURAL FIBERBOARD BRACED WALL PANELS IN A CONTINUOUSLY-SHEATHED WALL |
180 | FIGURE R602.10.6(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING FIGURE R602.10.6(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING |
181 | FIGURE R602.10.6.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS FIGURE R602.10.6.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES |
182 | FIGURE R602.10.6.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES |
183 | FIGURE R602.10.7 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS |
184 | FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION TABLE R602.12(1) STONE OR MASONRY VENEER WALL BRACING REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C |
185 | FIGURE R602.12 HOLD DOWNS AT EXTERIOR AND INTERIOR BRACED WALL PANELS SECTION R603 STEEL WALL FRAMING |
186 | FIGURE R603.1.2 TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS |
187 | FIGURE R603.2(1) C-SHAPED SECTION FIGURE R603.2(2) TRACK SECTION TABLE R603.2.4 SCREW SUBSTITUTION FACTOR |
188 | FIGURE R603.2.5.1 WEB HOLES FIGURE R603.2.5.3 STUD WEB HOLE PATCH |
189 | TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS |
190 | FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION |
191 | FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTS |
192 | TABLE R603.3.2(1) WALL FASTENING SCHEDULE TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL |
193 | TABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL |
194 | TABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL |
195 | TABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 50 KSI STEEL |
196 | TABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL |
197 | TABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 50 KSI STEEL |
198 | TABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL |
199 | TABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 50 KSI STEEL |
200 | TABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 KSI STEEL |
201 | TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 50 KSI STEEL |
202 | TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 33 KSI STEEL |
203 | TABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 50 KSI STEEL |
204 | TABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 33 KSI STEEL |
205 | TABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 50 KSI STEEL |
206 | TABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 33 KSI STEEL |
207 | TABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 50 KSI STEEL |
208 | TABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 33 KSI STEEL |
209 | TABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 50 KSI STEEL |
210 | TABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 33 KSI STEEL |
211 | TABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING 50 KSI STEEL |
212 | TABLE R603.3.2(22) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 33 KSI STEEL |
213 | TABLE R603.3.2(23) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 50 KSI STEEL |
214 | TABLE R603.3.2(24) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 33 KSI STEEL |
215 | TABLE R603.3.2(25) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 50 KSI STEEL |
216 | TABLE R603.3.2(26) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 33 KSI STEEL |
217 | TABLE R603.3.2(27) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 50 KSI STEEL |
218 | TABLE R603.3.2(28) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 33 KSI STEEL |
219 | TABLE R603.3.2(29) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 50 KSI STEEL |
220 | TABLE R603.3.2(30) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 33 KSI STEEL |
221 | TABLE R603.3.2(31) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING 50 KSI STEEL |
222 | FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY |
223 | FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL FIGURE R603.3.5 TRACK SPLICE |
224 | FIGURE R603.4 CORNER FRAMING |
225 | TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHT 33 KSI STEEL |
226 | TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHT 50 KSI STEEL |
227 | TABLE R603.3.2.1(3) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHT 33 KSI STEEL |
228 | TABLE R603.3.2.1(4) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHT 50 KSI STEEL |
229 | FIGURE R603.6(1) BOX BEAM HEADER FIGURE 603.6(2) BACK-TO-BACK HEADER |
230 | FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL |
231 | TABLE R603.6(1) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (33 KSI STEEL) |
232 | TABLE R603.6(2) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (50 KSI STEEL) |
233 | TABLE R603.6(3) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (33 KSI STEEL) |
234 | TABLE R603.6(4) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (50 KSI STEEL) |
235 | TABLE R603.6(5) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (33 KSI STEEL) |
236 | TABLE R603.6(6) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (50 KSI STEEL) |
237 | TABLE R603.6(7) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (33 KSI STEEL) |
238 | TABLE R603.6(8) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (50 KSI STEEL) |
239 | TABLE R603.6(9) BOX-BEAM HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (33 KSI STEEL) |
240 | TABLE R603.6(10) BOX-BEAM HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (50 KSI STEEL) |
241 | TABLE R603.6(11) BOX-BEAM HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (33 KSI STEEL) |
242 | TABLE R603.6(12) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel) |
243 | TABLE R603.6(13) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (33 KSI STEEL) |
244 | TABLE R603.6(14) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (50 KSI STEEL) |
245 | TABLE R603.6(15) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (33 KSI STEEL) |
246 | TABLE R603.6(16) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ROOF AND CEILING ONLY (50 KSI STEEL) |
247 | TABLE R603.6(17) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (33 KSI STEEL) |
248 | TABLE R603.6(18) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (50 KSI STEEL) |
249 | TABLE R603.6(19) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (33 KSI STEEL) |
250 | TABLE R603.6(20) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (50 KSI STEEL) |
251 | TABLE R603.6(21) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (33 KSI STEEL) |
252 | TABLE R603.6(22) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (50 KSI STEEL) |
253 | TABLE R603.6(23) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (33 KSI STEEL) |
254 | TABLE R603.6(24) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING TWO FLOORS, ROOF AND CEILING (50 KSI STEEL) |
255 | TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING |
256 | TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTS TABLE R603.8 HEAD AND SILL TRACK SPAN FY = 33 KSI |
257 | FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN FIGURE R603.9.2 CORNER STUD HOLD DOWN DETAIL |
258 | TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLS TABLE R603.9.2(2) FULL HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS |
259 | SECTION R604 WOOD STRUCTURAL PANELS SECTION R605 PARTICLEBOARD SECTION R606 GENERAL MASONRY CONSTRUCTION |
260 | TABLE R606.5 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY |
261 | TABLE R606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS |
262 | FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF |
263 | FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C |
264 | FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1, OR D2 |
265 | TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES |
266 | TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 OR D1 |
267 | TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 TABLE R606.15.1 MINIMUM CORROSION PROTECTION SECTION R607 UNIT MASONRY |
268 | TABLE R607.1 MORTAR PROPORTIONS SECTION R608 MULTIPLE WYTHE MASONRY |
269 | TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS |
270 | SECTION R609 GROUTED MASONRY |
271 | SECTION R610 GLASS UNIT MASONRY FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE |
272 | SECTION R611 EXTERIOR CONCRETE WALL CONSTRUCTION |
273 | TABLE R611.3 DIMENSIONAL REQUIREMENTS FOR WALLS |
274 | FIGURE R611.3(1) FLAT WALL SYSTEM FIGURE R611.3(2) WAFFLE-GRID WALL SYSTEM FIGURE R611.3(3) SCREEN-GRID WALL SYSTEM |
276 | TABLE R611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS FIGURE R611.5.4(1) LAP SPLICES |
277 | FIGURE R611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION FIGURE R611.5.4(3) STANDARD HOOKS |
278 | TABLE R611.5.4(2) MAXIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL |
279 | FIGURE R611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE FIGURE R611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY |
280 | FIGURE R611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY FIGURE R611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON GROUND FOOTING |
281 | TABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS |
282 | TABLE R611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS |
283 | TABLE R611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLS |
284 | TABLE R611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS |
285 | TABLE R611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORY |
286 | TABLE R611.7(1A)—CONTINUED UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORY |
287 | TABLE R611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STOY OF TWO STORY |
288 | TABLE R611.7(1B)—CONTINUED UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY |
289 | TABLE R611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE |
290 | TABLE R611.7(1C)—CONTINUED UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY |
291 | (EQUATION R611-1) (EQUATION R611-2) |
292 | FIGURE R611.7(1) MINIMUM SOLID WALL LENGTH |
293 | FIGURE R611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL |
294 | TABLE R611.7(2) REDUCTION FACTOR, R1 FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEET FIGURE R611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS |
295 | TABLE R611.7(3) REDUCTION FACTOR, R2 FOR FLOOR-TO-CELLING WALL HEIGHTS LESS THAN 10 FEET |
296 | TABLE R611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3 FOR FLAT, WAFFLE- AND SCRREN-GRID WALLS |
298 | FIGURE R611.8(1) REINFORCEMENT OF OPENINGS FIGURE R611.8(2) LINTEL FOR FLAT WALLS |
299 | FIGURE R611.8(3) LINTELS FOR WAFFLE-GRID WALLS |
300 | FIGURE R611.8(4) LINTELS FOR SCREEN-GRID WALLS |
301 | TABLE R611.8(1) LINTEL DESIGN LOADING CONDITIONS |
302 | TABLE R611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
303 | TABLE R611.8(2)—CONTINUED MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
304 | TABLE R611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
305 | TABLE R611.8(3)—CONTINUED MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
306 | TABLE R611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
307 | TABLE R611.8(4)—CONTINUED MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
308 | TABLE R611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
309 | TABLE R611.8(5)—CONTINUED MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS, ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
310 | TABLE R611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLS, MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET |
311 | TABLE R611.8(6)—CONTINUED MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLS, MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
312 | TABLE R611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLS, MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
313 | TABLE R611.8(7)—CONTINUED MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLS, MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
314 | TABLE R611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLS ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
315 | TABLE R611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS |
316 | TABLE R611.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET TABLE R611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS |
318 | FIGURE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
319 | TABLE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR TABLE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
320 | FIGURE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL |
321 | FIGURE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR |
322 | TABLE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR TABLE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
323 | FIGURE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL |
324 | FIGURE R611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
325 | TABLE R611.9(5) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR TABLE R611.9(6) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
326 | FIGURE R611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
327 | FIGURE R611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR |
328 | TABLE R611.9(7) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR TABLE R611.9(8) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
329 | FIGURE R611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
330 | TABLE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR TABLE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
331 | FIGURE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
332 | FIGURE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PARALLEL |
333 | TABLE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR TABLE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
334 | FIGURE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
335 | FIGURE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
336 | SECTION R612 EXTERIOR WINDOWS AND DOORS |
338 | SECTION R613 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION FIGURE R612.8(1) THROUGH THE FRAME FIGURE R612.8(2) FRAME CLIP FIGURE R612.8(3) THROUGH THE FRAME |
339 | FIGURE R612.8(4) FRAME CLIP FIGURE R612.8(5) THROUGH THE FLANGE FIGURE R612.8(6) THROUGH THE FLANGE FIGURE R612.8(7) FRAME CLIP FIGURE R612.8(8) THROUGH THE FLANGE |
340 | FIGURE R613.4 SIP WALL PANEL |
341 | TABLE R613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE TABLE R613.3.2 MINIMUM PROPERTIES FOR WOOD STRUCTURAL PANEL FACING MATERIAL USED IN SIP WALLS |
342 | TABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP LIGHT-FRAME ROOF ONLY (INCHES) |
343 | TABLE R613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (INCHES) |
344 | FIGURE R613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS FIGURE R613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS |
345 | FIGURE R613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION FIGURE R613.5(4) SIP WALL TO WALL PLATFORM FRAME CONNECTION |
346 | FIGURE R613.5(5) SIP WALL TO WALL BALLOON FRAME CONNECTION (I-JOIST FLOOR SHOWN FOR ILLUSTRATION ONLY) FIGURE R613.5.1 SIP WALL FRAMING CONFIGURATION |
347 | FIGURE R613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT FIGURE R613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS |
348 | FIGURE R613.9 SIP CORNER FRAMING DETAIL TABLE R613.10 MAXIMUM SPANS FOR 11 7/8 INCH DEEP SIP HEADERS (FEET) |
349 | CHAPTER 7 WALL COVERING SECTION R701 GENERAL SECTION R702 INTERIOR COVERING TABLE R702.1(1) THICKNESS OF PLASTER TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSA |
350 | TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD |
352 | TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES SECTION R703 EXTERIOR COVERING |
354 | TABLE R703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS |
355 | TABLE R703.4—CONTINUED WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLS |
356 | TABLE R703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C |
357 | FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES |
358 | FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS TABLE R703.7.3 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER |
361 | CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL SECTION R802 WOOD ROOF FRAMING |
365 | TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 10 PSF, L/Δ = 240) |
366 | TABLE R802.4(1)—CONTINUED CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 10 PS L/Δ = 240) |
367 | TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITH LIMITED STORAGE, LIVE LOAD = 20 PSF, L/Δ = 240) |
368 | TABLE R802.4(2)—CONTINUED CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITH LIMITED STORAGE, LIVE LOAD = 20 PSF, L/Δ = 240) |
369 | TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD=20 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
370 | TABLE R802.5.1(1)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD=20 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
371 | TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD=20 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
372 | TABLE R802.5.1(2)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD=20 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
373 | TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=30 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
374 | TABLE R802.5.1(3)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=30 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
375 | TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=50 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
376 | TABLE R802.5.1(4)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=50 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
377 | TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=30 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
378 | TABLE R802.5.1(5)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=30 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
379 | TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=50 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
380 | TABLE R802.5.1(6)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD=50 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
381 | TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
382 | TABLE R802.5.1(7)—CONTINUED RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
383 | TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
384 | TABLE R802.5.1(8)—CONTINUED RAFTER SPANS FOR 70 PSF GROUND SNOW LOADA (CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
385 | TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS |
386 | FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION TABLE R802.11 REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCES OF 20 PSF OR GREATER (POUNDS PER CONNECTION) |
387 | SECTION R803 ROOF SHEATHING TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING SECTION R804 STEEL ROOF FRAMING |
388 | FIGURE R804.1.2 IN-LINE FRAMING TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS |
389 | FIGURE R804.2(1) C-SHAPED SECTION FIGURE R804.2(2) TRACK SECTION TABLE R804.2.4 SCREW SUBSTITUTION FACTOR |
390 | FIGURE R804.2.5.1 WEB HOLES FIGURE R804.2.5.3 WEB HOLE PATCH |
391 | FIGURE R804.3 STEEL ROOF CONSTRUCTION TABLE R804.3 ROOF FRAMING FASTENING SCHEDULE |
394 | TABLE R804.3.1.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 LB PER SQ FT LIVE LOAD (NO ATTIC STORAGE) 33 KSI STEEL |
395 | TABLE R804.3.1.1(2) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 10 LB PER SQ FT LIVE LOAD (NO ATTIC STORAGE) 33 KSI STEEL |
396 | TABLE R804.3.1.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 LB PER SQ FT LIVE LOAD (LIMITED ATTIC STORAGE) 33 KSI STEEL |
397 | TABLE R804.3.1.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 LB PER SQ FT LIVE LOAD (LIMITED ATTIC STORAGE) 33 KSI STEEL |
398 | TABLE R804.3.1.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 LB PER SQ FT LIVE LOAD (NO ATTIC STORAGE) 33 KSI STEEL |
399 | TABLE R804.3.1.1(6) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 LB PER SQ FT LIVE LOAD (NO ATTIC STORAGE) 33 KSI STEEL |
400 | TABLE R804.3.1.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 LB PER SQ FT LIVE LOAD (LIMITED ATTIC STORAGE 33 KSI STEEL |
401 | TABLE R804.3.1.1(8) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 LB PER SQ FT LIVE LOAD (LIMITED ATTIC STORAGE) 33 KSI STEEL |
402 | FIGURE R804.3.1.1(1) JOIST TO RAFTER CONNECTION TABLE R804.3.1.1(9) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTION |
403 | FIGURE R804.3.1.1(2) BEARING STIFFENER FIGURE R804.3.1.4(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL |
404 | FIGURE R804.3.1.4(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING FIGURE R804.3.1.5 SPLICED CEILING JOISTS |
405 | TABLE R804.3.2.1(1) ROOF RAFTER SPANS 33 KSI STEEL |
406 | TABLE R804.3.2.1(2) ROOF RAFTER SPANS 50 KSI STEEL |
407 | TABLE R804.3.2.1(3) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS |
408 | TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTER TO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTION FIGURE R804.3.2.4 HIP MEMBER OR RIDGE MEMBER CONNECTION |
409 | TABLE R804.3.3.2 HIP MEMBER SIZES, 33 KSI STEEL TABLE R804.3.3.3 HIP SUPPORT COLUMN SIZES 33 KSI STEEL |
410 | TABLE R804.3.3.4(1) UPLIFT STRAP CONNECTION REQUIREMENTS HIP SUPPORT COLUMN AT CEILING LINE FIGURE R804.3.3.4(1) JACK RAFTER CONNECTION AT EAVE |
411 | TABLE R804.3.3.4(2) CONNECTION REQUIREMENTSHIP MEMBER TO HIP SUPPORT COLUMN FIGURE R804.3.3.4(2) HIP SUPPORT COLUMN |
412 | TABLE R804.3.3.4(3) UPLIFT STRAP CONNECTION REQUIREMENTS HIP MEMBER TO WALL FIGURE R804.3.3.4(3) HIP CONNECTIONS AT RIDGE |
413 | FIGURE R804.3.3.4(4) HIP CONNECTIONS AT RIDGE AND BOX COLUMN |
414 | FIGURE R804.3.3.4(5) HIP MEMBER CONNECTION AT WALL CORNER FIGURE R804.3.6(1) ROOF OR CEILING OPENING |
415 | FIGURE R804.3.6(2) HEADER TO TRIMMER CONNECTION TABLE R804.3.8(1) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FT |
416 | FIGURE R804.3.8(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL TABLE R804.3.8(2) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED CEILING HEIGHT = 9 OR 10 FT |
417 | FIGURE R804.3.8(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL TABLE R804.3.8(3) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS WOOD STRUCTURAL PANEL SHEATHED CEILING HEIGHT = 8, 9 OR 10 FT |
418 | FIGURE R804.3.8(3) ROOF BLOCKING DETAIL SECTION R805 CEILING FINISHES SECTION R806 ROOF VENTILATION |
419 | TABLE R806.4 INSULATION FOR CONDENSATION CONTROL SECTION R807 ATTIC ACCESS |
421 | CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL SECTION R902 ROOF CLASSIFICATION SECTION R903 WEATHER PROTECTION SECTION R904 MATERIALS |
422 | SECTION R905 REQUIREMENTS FOR ROOF COVERINGS TABLE R905.2.4.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158 TABLE R905.2.4.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161 |
423 | TABLE R905.2.8.2 VALLEY LINING MATERIAL |
424 | TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT |
425 | TABLE R905.6.5 SLATE SHINGLE HEADLAP |
426 | TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS |
427 | TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE |
428 | TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS TABLE R905.10.3(1) METAL ROOF COVERINGS STANDARDS |
429 | TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS SECTION R906 ROOF INSULATION TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION R907 REROOFING |
431 | CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES |
432 | TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS |
433 | FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS |
434 | SECTION R1002 MASONRY HEATERS |
435 | FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES SECTION R1003 MASONRY CHIMNEYS |
437 | TABLE R1003.14(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZES TABLE R1003.14(2) NET CROSS–SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES |
438 | FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS |
439 | FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES FIGURE R1003.20 CHIMNEY CRICKET |
440 | TABLE R1003.20 CRICKET DIMENSIONS SECTION R1004 FACTORY-BUILT FIREPLACES SECTION R1005 FACTORY-BUILT CHIMNEYS SECTION R1006 EXTERIOR AIR SUPPLY |
441 | PART IV — ENERGY CONSERVATION CHAPTER CHAPTER 11 ENERGY EFFICIENCY SECTION N1101 SCOPE, GENERAL REQUIREMENTS, AND ADDITIONAL DEFINITIONS |
443 | TABLE N1101.2 NORTH CAROLINA CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY COUNTY Key: A – Moist, B – Dry, C – Marine. Absence of moisture designation indicates moisture regime is irrelevant. Asterisk (*) indicates a warm-humid location. FIGURE N1101.2(1) NORTH CAROLINA CLIMATE ZONES |
444 | FIGURE N1101.2(2) CLIMATE ZONES |
445 | TABLE N1101.5(1) DEFAULT GLAZED FENESTRATION U-FACTORS TABLE N1101.5(2) DEFAULT DOOR U-FACTORS TABLE N1101.5(3) DEFAULT GLAZED FENESTRATION SHGC SECTION N1102 BUILDING THERMAL ENVELOPE |
446 | TABLE N1102.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT |
447 | TABLE N1102.1.2 EQUIVALENT U-FACTORS TABLE N1102.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
448 | TABLE N1102.2.9 WALL INSULATION ALLOWANCES FOR TERMITE TREATMENT AND INSULATION GAPS |
449 | TABLE N1102.4.2 AIR BARRIER INSPECTION |
450 | SECTION N1103 SYSTEMS |
451 | SECTION N1104 LIGHTING SYSTEMS |
453 | PART V — MECHANICAL CHAPTERS 12 THROUGH 23 DELETED |
455 | PART V 2012 NORTH CAROLINA STATE BUILDING CODE: MECHANICAL CODE ABRIDGED FOR RESIDENTICAL CODE (2009 IMC® WITH NORTH CAROLINA AMENDMENTS) |
457 | TABLE OF CONTENTS |
461 | CHAPTER 1 SCOPE AND ADMINISTRATION PART I—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
462 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 APPROVAL SECTION 106 PERMITS SECTION 107 INSPECTIONS AND TESTING SECTION 108 VIOLATIONS SECTION 109 MEANS OF APPEAL |
463 | SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
465 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
473 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL |
474 | SECTION 302 PROTECTION OF STRUCTURE SECTION 303 EQUIPMENT AND APPLIANCE LOCATION |
475 | SECTION 304 INSTALLATION |
476 | SECTION 305 PIPING SUPPORT TABLE 305.4 PIPING SUPPORT SPACING SECTION 306 ACCESS AND SERVICE SPACE |
477 | SECTION 307 CONDENSATE DISPOSAL TABLE 307.2.2 CONDENSATE DRAIN SIZING DELETED |
478 | SECTION 308 CLEARANCE REDUCTION FOR UNLISTED EQUIPMENT AND UNLISTED APPLIANCES [B] SECTION 309 TEMPERATURE CONTROL [F] SECTION 310 EXPLOSION CONTROL DELETED [F] SECTION 311 SMOKE AND HEAT VENTS DELETED SECTION 312 HEATING AND COOLING LOAD CALCULATIONS |
479 | TABLE 308.6 CLEARANCE REDUCTION METHODS FOR UNLISTED EQUIPMENT |
481 | CHAPTER 4 VENTILATION SECTION 401 GENERAL TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS SECTION 402 NATURAL VENTILATION SECTION 403 MECHANICAL VENTILATION |
482 | TABLE 403.3 MINIMUM VENTILATION RATES SECTION 404 ENCLOSED PARKING GARAGES DELETED SECTION 405 SYSTEMS CONTROL DELETED SECTION 406 VENTILATION OF UNINHABITED SPACES DELETED |
483 | CHAPTER 5 EXHAUST SYSTEMS SECTION 501 GENERAL SECTION 502 REQUIRED SYSTEMS |
484 | SECTION 503 MOTORS AND FANS DELETED SECTION 504 CLOTHES DRYER EXHAUST TABLE 504.6.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH |
485 | SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT DELETED SECTION 507 COMMERCIAL KITCHEN HOODS DELETED SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR DELETED SECTION 509 FIRE SUPPRESSION SYSTEMS DELETED SECTION 510 HAZARDOUS EXHAUST SYSTEMS DELETED SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS DELETED SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS DELETED SECTION 513 SMOKE CONTROL SYSTEMS DELETED SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS DELETED |
487 | CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL SECTION 602 PLENUMS SECTION 603 DUCT CONSTRUCTION AND INSTALLATION |
489 | TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS |
490 | SECTION 604 INSULATION |
491 | SECTION 605 AIR FILTERS SECTION 606 SMOKE DETECTION SYSTEMS CONTROL DELETED [B] SECTION 607 DUCT AND TRANSFER OPENINGS DELETED |
493 | CHAPTER 7 COMBUSTION AIR SECTION 701 GENERAL |
495 | CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL |
496 | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION |
497 | SECTION 803 CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES |
498 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES (FOR CHIMNEY CONNECTOR SYSTEM DETAILS, SEE APPENDIX A) TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS |
499 | SECTION 805 FACTORY-BUILT CHIMNEYS SECTION 806 METAL CHIMNEYS DELETED |
501 | CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE STOVES AND ROOM HEATERS SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES SECTION 907 INCINERATORS AND CREMATORIES DELETED SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS DELETED SECTION 909 VENTED WALL FURNACES |
502 | SECTION 910 FLOOR FURNACES SECTION 911 DUCT FURNACES DELETED SECTION 912 INFRARED RADIANT HEATERS DELETED SECTION 913 CLOTHES DRYERS SECTION 914 SAUNA HEATERS |
503 | SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES DELETED SECTION 916 POOL AND SPA HEATERS SECTION 917 COOKING APPLIANCES SECTION 918 FORCED-AIR WARM-AIR FURNACES |
504 | SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS DELETED SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS DELETED SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS DELETED SECTION 925 MASONRY HEATERS DELETED SECTION 926 GASEOUS HYDROGEN SYSTEMS DELETED SECTION 927 HEAT RECOVERY VENTILATORS DELETED SECTION 928 RADIANT HEATING SYSTEMS |
505 | SECTION 929 BASEBOARD CONVECTORS SECTION 930 DUCT HEATERS |
507 | CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL SECTION 1002 WATER HEATERS SECTION 1003 PRESSURE VESSELS SECTION 1004 BOILERS |
508 | SECTION 1005 BOILER CONNECTIONS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS SECTION 1007 BOILER LOW-WATER CUTOFF SECTION 1008 STEAM BLOWOFF VALVE SECTION 1009 HOT WATER BOILER EXPANSION TANK |
509 | EQUATION 10-1 SECTION 1010 GAUGES SECTION 1011 TESTS DELETED |
511 | CHAPTER 11 REFRIGERATION SECTION 1101 GENERAL SECTION 1102 SYSTEM REQUIREMENTS SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION DELETED SECTION 1104 SYSTEM APPLICATION REQUIREMENTS DELETED SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS DELETED SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS DELETED SECTION 1107 REFRIGERANT PIPING |
512 | SECTION 1108 FIELD TEST DELETED [F] SECTION 1109 PERIODIC TESTING DELETED |
513 | CHAPTER 12 HYDRONIC PIPING SECTION 1201 GENERAL SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE TABLE 1202.4—CONTINUED HYDRONIC PIPE TABLE 1202.5 HYDRONIC PIPE FITTINGS |
514 | SECTION 1203 JOINTS AND CONNECTIONS |
515 | SECTION 1204 PIPE INSULATION |
516 | SECTION 1205 VALVES SECTION 1206 PIPING INSTALLATION SECTION 1207 TRANSFER FLUID DELETED SECTION 1208 TESTS |
517 | SECTION 1209 EMBEDDED PIPING |
519 | CHAPTER 13 FUEL OIL PIPING AND STORAGE SECTION 1301 GENERAL SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING SECTION 1303 JOINTS AND CONNECTIONS |
520 | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION |
521 | SECTION 1306 OIL GAUGING SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING SECTION 1309 OIL TANKS FOR ONE AND TWO-FAMILY DWELLINGS AND TOWNHOUSES |
523 | CHAPTER 14 SOLAR SYSTEMS SECTION 1401 GENERAL SECTION 1402 INSTALLATION |
524 | SECTION 1403 HEAT TRANSFER FLUIDS SECTION 1404 MATERIALS |
525 | CHAPTER 15 REFERENCED STANDARDS ACCA AHRI ANSI ASHRAE ASME |
526 | ASSE ASTM |
527 | AWS |
528 | AWWA CSA DOL FS ICC |
529 | IIAR MSS NAIMA NFPA |
530 | SMACNA UL |
533 | APPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING DELETED. FIGURE A-2 ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC DELETED. FIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC DELETED. FIGURE A-4 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS DELETED. |
534 | FIGURE A-5 CHIMNEY CONNECTOR SYSTEMS |
535 | FIGURE A-5—CONTINUED CHIMNEY CONNECTOR SYSTEMS |
537 | APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE DELETED |
539 | PART VI — FUEL GAS CHAPTER 24 DELETED |
541 | PART VI 2012 NORTH CAROLINA STATE BUILDING CODE: FUEL GAS CODE ABRIDGED FOR RESIDENTIAL CODE (2009 IFGC® WITH NORTH CAROLINA AMENDMENTS) |
543 | TABLE OF CONTENTS |
545 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 (IFGC) GENERAL |
546 | SECTION 102 (IFGC) APPLICABILITY SECTION 103 (IFGC) DEPARTMENT OF INSPECTION SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 (IFGC) APPROVAL |
547 | SECTION 106 (IFGC) PERMITS SECTION 107 (IFGC) INSPECTIONS AND TESTING SECTION 108 (IFGC) VIOLATIONS SECTION 109 (IFGC) MEANS OF APPEAL SECTION 110 (IFGC) TEMPORARY EQUIPMENT, SYSTEMS AND USES |
549 | CHAPTER 2 DEFINITIONS SECTION 201 (IFGC) GENERAL SECTION 202 (IFGC) GENERAL DEFINITIONS |
557 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 (IFGC) GENERAL |
558 | SECTION 302 (IFGC) STRUCTURAL SAFETY SECTION 303 (IFGC) APPLIANCE LOCATION |
559 | SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR EQUATION 3-1 EQUATION 3-2 |
560 | FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (SEE SECTION 304.5.3) FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (SEE SECTION 304.6.1) FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (SEE SECTION 304.6.1) |
561 | FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (SEE SECTION 304.6.1) FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (SEE SECTION 304.6.2) |
562 | SECTION 305 (IFGC) INSTALLATION |
563 | SECTION 306 (IFGC) ACCESS AND SERVICE SPACE |
564 | SECTION 307 (IFGC) CONDENSATE DISPOSAL SECTION 308 (IFGS) CLEARANCE REDUCTION FOR UNLISTED EQUIPMENT |
565 | SECTION 309 (IFGC) ELECTRICAL SECTION 310 (IFGS) ELECTRICAL BONDING |
566 | TABLE 308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION |
567 | FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM |
569 | CHAPTER 4 GAS PIPING INSTALLATIONS SECTION 401 (IFGC) GENERAL SECTION 402 (IFGS) PIPE SIZING EQUATION 4-1 |
570 | EQUATION 4-2 TABLE 402.2 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES TABLE 402.4 C, AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE DELETED TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE DELETED TABLE 402.4(6) SEMIRIGID COPPER TUBING DELETED TABLE 402.4(9) SEMIRIGID COPPER TUBING DELETED TABLE 402.4(11) SEMIRIGID COPPER TUBING DELETED TABLE 402.4(14) CORRUGATED STAINLESS STEEL TUBING (CSST) DELETED TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST) DELETED TABLE 402.4(18) POLYETHYLENE PLASTIC PIPE DELETED TABLE 402.4(21) POLYETHYLENE PLASTIC TUBING DELETED |
571 | TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE |
572 | TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE |
573 | TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE |
574 | TABLE 402.4(7) SEMIRIGID COPPER TUBING |
575 | TABLE 402.4(8) SEMIRIGID COPPER TUBING |
576 | TABLE 402.4(10) SEMIRIGID COPPER TUBING |
577 | TABLE 402.4(12) SEMIRIGID COPPER TUBING |
578 | TABLE 402.4(13) CORRUGATED STAINLESS STEEL TUBING (CSST) |
579 | TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST) |
580 | TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST) |
581 | TABLE 402.4(19) POLYETHYLENE PLASTIC PIPE |
582 | TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE |
583 | TABLE 402.4(22) POLYETHYLENE PLASTIC TUBING |
584 | TABLE 402.4(23) SCHEDULE 40 METALLIC PIPE |
585 | TABLE 402.4(24) SCHEDULE 40 METALLIC PIPE |
586 | TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE |
587 | TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE |
588 | TABLE 402.4(27) SEMIRIGID COPPER TUBING |
589 | TABLE 402.4(28) SEMIRIGID COPPER TUBING |
590 | TABLE 402.4(29) SEMIRIGID COPPER TUBING |
591 | TABLE 402.4(30) CORRUGATED STAINLESS STEEL TUBING (CSST) |
592 | TABLE 402.4(31) CORRUGATED STAINLESS STEEL TUBING (CSST) |
593 | TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST) |
594 | TABLE 402.4(33) POLYETHYLENE PLASTIC PIPE |
595 | TABLE 402.4(34) POLYETHYLENE PLASTIC PIPE |
596 | TABLE 402.4(35) POLYETHYLENE PLASTIC TUBING |
597 | TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE SIZING BETWEEN FIRST STAGE AND SECOND STAGE REGULATOR |
598 | TABLE 402.4(37) POLYETHYLENE PLASTIC TUBE SIZING |
599 | SECTION 403 (IFGS) PIPING MATERIALS |
600 | TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE |
601 | SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION |
602 | SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION |
603 | SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING |
604 | SECTION 407 (IFGC) PIPING SUPPORT |
605 | SECTION 408 (IFGC) DRIPS AND SLOPED PIPING SECTION 409 (IFGC) SHUTOFF VALVES TABLE 409.1.1 MANUAL GAS VALVE STANDARDS SECTION 410 (IFGC) FLOW CONTROLS |
606 | SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS |
607 | SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES DELETED SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES DELETED SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY DELETED SECTION 415 (IFGS) PIPING SUPPORT INTERVALS TABLE 415.1 SUPPORT OF PIPING SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES |
609 | CHAPTER 5 CHIMNEYS AND VENTS SECTION 501 (IFGC) GENERAL |
610 | SECTION 502 (IFGC) VENTS |
611 | SECTION 503 (IFGS) VENTING OF APPLIANCES |
612 | TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED |
613 | FIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT APPLIANCES |
615 | FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL |
617 | TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES |
618 | TABLE 503.10.5 CLEARANCES FOR CONNECTORS |
620 | SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS |
622 | TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT |
623 | TABLE 504.2(1)—CONTINUED TYPE B DOUBLE-WALL GAS VENT |
624 | TABLE 504.2(1)—CONTINUED TYPE B DOUBLE-WALL GAS VENT |
625 | TABLE 504.2(1)—CONTINUED TYPE B DOUBLE-WALL GAS VENT |
626 | TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT |
627 | TABLE 504.2(2)—CONTINUED TYPE B DOUBLE-WALL GAS VENT |
628 | TABLE 504.2(3) MASONRY CHIMNEY |
629 | TABLE 504.2(3)—CONTINUED MASONRY CHIMNEY |
630 | TABLE 504.2(4) MASONRY CHIMNEY |
631 | TABLE 504.2(4)—CONTINUED MASONRY CHIMNEY |
632 | TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT |
633 | TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY |
634 | TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH |
636 | SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS |
637 | TABLE 504.3(1) TYPE B DOUBLE-WALL VENT |
638 | TABLE 504.3(1)—CONTINUED TYPE B DOUBLE-WALL VENT |
639 | TABLE 504.3(2) TYPE B DOUBLE-WALL VENT |
640 | TABLE 504.3(3) MASONRY CHIMNEY |
641 | TABLE 504.3(4) MASONRY CHIMNEY |
642 | TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT |
643 | TABLE 504.3(6A) EXTERIOR MASONRY CHIMNEY TABLE 504.3(6B) EXTERIOR MASONRY CHIMNEY TABLE 504.3(6B) EXTERIOR MASONRY CHIMNEY—CONTINUED |
644 | TABLE 504.3(7A) EXTERIOR MASONRY CHIMNEY TABLE 504.3(7B) EXTERIOR MASONRY CHIMNEY TABLE 504.3(7B) EXTERIOR MASONRY CHIMNEY—CONTINUED |
645 | CHAPTER 6 SPECIFIC APPLIANCES SECTION 601 (IFGC) GENERAL SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES SECTION 603 (IFGC) LOG LIGHTERS SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS SECTION 606 (IFGC) INCINERATORS AND CREMATORIES DELETED SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS DELETED SECTION 608 (IFGC) VENTED WALL FURNACES SECTION 609 (IFGC) FLOOR FURNACES |
646 | SECTION 610 (IFGC) DUCT FURNACES SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS DELETED SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS DELETED SECTION 613 (IFGC) CLOTHES DRYERS SECTION 614 (IFGC) CLOTHES DRYER EXHAUST |
647 | SECTION 615 (IFGC) SAUNA HEATERS |
648 | [M] TABLE 614.6.5.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT SECTION 617 (IFGC) POOL AND SPA HEATERS SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES |
650 | SECTION 619 (IFGC) CONVERSION BURNERS SECTION 620 (IFGC) UNIT HEATERS DELETED SECTION 621 (IFGC) UNVENTED ROOM HEATERS SECTION 622 (IFGC) VENTED ROOM HEATERS SECTION 623 (IFGC) COOKING APPLIANCES |
651 | SECTION 624 (IFGC) WATER HEATERS SECTION 625 (IFGC) REFRIGERATORS DELETED SECTION 626 (IFGC) GAS-FIRED TOILETS DELETED SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES SECTION 628 (IFGC) ILLUMINATING APPLIANCES SECTION 629 (IFGC) SMALL CERAMIC KILNS |
652 | SECTION 630 (IFGC) INFRARED RADIANT HEATERS SECTION 631 (IFGC) BOILERS SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS DELETED SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS DELETED SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA DELETED SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS DELETED |
653 | CHAPTER 7 GASEOUS HYDROGEN SYSTEMS DELETED |
655 | IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS ANSI |
656 | ASME ASTM CGA CSA |
657 | DOTn ICC MSS NFPA |
658 | UL |
659 | APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING A.1 GENERAL PIPING CONSIDERATIONS A.2 DESCRIPTIONS OF TABLES |
660 | TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
661 | TABLE A.2.2—CONTINUED EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
662 | TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0. A.3 USE OF CAPACITY TABLES |
664 | TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS A.4 USE OF SIZING EQUATIONS |
665 | A.5 PIPE AND TUBE DIAMETERS TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES TABLE A.5.2 COPPER TUBE STANDARD SIZES A.6 USE OF SIZING CHARTS |
666 | FIGURE A.6 (A) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC) FIGURE A.6 (B) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 PSI AND ABOVE) |
667 | A.7 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM |
668 | FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM |
669 | FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM |
671 | APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANC EXAMPLES USING SINGLE APPLIANCE VENTING TABLES FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR |
672 | FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR |
673 | FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES |
674 | FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR FIGURE B-12 USE OF OFFSET COMMON VENT FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM FIGURE B-14 MULTISTORY VENT SYSTEMS |
675 | FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE |
676 | EXAMPLES USING COMMON VENTING TABLES FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFTHOOD EQUIPPED APPLIANCES FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT |
678 | TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTS |
679 | FIGURE B-19 |
681 | APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS |
683 | APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION |
685 | PART VII — PLUMBING CHAPTERS 25 THROUGH 33 DELETED |
687 | PART VII 2012 NORTH CAROLINA STATE BUILDING CODE: ABRIDGED FOR RESIDENTIAL CODE (2009 IPC® WITH NORTH CAROLINA AMENDMENTS) |
689 | TABLE OF CONTENTS |
693 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
694 | SECTION 103 DEPARTMENT OF PLUMBING INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 APPROVAL |
695 | SECTION 106 PERMITS SECTION 107 INSPECTIONS AND TESTING SECTION 108 VIOLATIONS SECTION 109 MEANS OF APPEAL SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
697 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
705 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS SECTION 304 RODENTPROOFING |
706 | TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS |
707 | SECTION 306 TRENCHING, EXCAVATION AND BACKFILL SECTION 307 STRUCTURAL SAFETY SECTION 308 PIPING SUPPORT |
708 | TABLE 308.5 HANGER SPACING SECTION 309 FLOOD HAZARD RESISTANCE |
709 | SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS DELETED SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 312 TESTS AND INSPECTIONS |
710 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL |
711 | CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESA (SEE SECTIONS 403.2 AND 403.3) SECTION 404 ACCESSIBLE PLUMBING FACILITIES DELETED SECTION 405 INSTALLATION OF FIXTURES |
712 | SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 407 BATHTUBS |
713 | SECTION 408 BIDETS SECTION 409 DISHWASHING MACHINES SECTION 410 DRINKING FOUNTAINS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS DELETED SECTION 412 FLOOR AND TRENCH DRAINS SECTION 413 FOOD WASTE GRINDER UNITS SECTION 414 GARBAGE CAN WASHERS DELETED SECTION 415 LAUNDRY TRAYS |
714 | SECTION 416 LAVATORIES SECTION 417 SHOWERS TABLE 417.4 PREFABRICATED SHOWER RECEPTOR STANDARDS MATERIALS STANDARDS |
715 | SECTION 418 SINKS SECTION 419 URINALS DELETED SECTION 420 WATER CLOSETS SECTION 421 WHIRLPOOL BATHTUBS SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT DELETED SECTION 423 SPECIALTY PLUMBING FIXTURES |
716 | SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
717 | SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT DELETED SECTION 427 FLOOR SINKS DELETED |
719 | CHAPTER 5 WATER HEATERS SECTION 501 GENERAL |
720 | SECTION 502 INSTALLATION SECTION 503 CONNECTIONS |
721 | SECTION 504 SAFETY DEVICES SECTION 505 INSULATION |
723 | CHAPTER 6 WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL SECTION 602 WATER REQUIRED SECTION 603 WATER SERVICE SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM |
724 | TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES |
725 | TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
726 | TABLE 605.3 WATER SERVICE PIPE |
727 | TABLE 605.4 WATER DISTRIBUTION PIPE TABLE 605.8 MANUFACTURED PIPE NIPPLES |
728 | TABLE 605.5 PIPE FITTINGS |
730 | SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM |
731 | TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS |
732 | SECTION 607 HOT WATER SUPPLY SYSTEM SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
733 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
734 | TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION |
735 | TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS |
736 | SECTION 609 HEALTH CARE PLUMBING DELETED SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM SECTION 611 DRINKING WATER TREATMENT UNITS |
737 | SECTION 612 SOLAR SYSTEMS SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES SECTION 614 PARTIAL FIRE SPRINKLER PROTECTION IN ONE- AND TWO-FAMILY DWELLINGS SECTION 615 FULL FIRE SPRINKLER PROTECTION IN ONEAND TWO-FAMILY DWELLINGS |
739 | CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL SECTION 702 MATERIALS TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
740 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.3 BUILDING SEWER PIPE |
741 | TABLE 702.4 PIPE FITTINGS SECTION 703 BUILDING SEWER SECTION 704 DRAINAGE PIPING INSTALLATION TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE SECTION 705 JOINTS |
744 | TABLE 705.21 CAULKING FERRULE SPECIFICATIONS TABLE 705.22 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS |
745 | TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS |
746 | SECTION 709 FIXTURE UNITS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS SECTION 710 DRAINAGE SYSTEM SIZING |
747 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
748 | TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKS |
749 | SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE DELETED SECTION 712 SUMPS AND EJECTORS TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION 713 HEALTH CARE PLUMBING DELETED SECTION 714 COMPUTERIZED DRAINAGE DESIGN DELETED |
750 | SECTION 715 BACKWATER VALVES |
751 | CHAPTER 8 INDIRECT/SPECIAL WASTE SECTION 801 GENERAL DELETED SECTION 802 INDIRECT WASTES SECTION 803 SPECIAL WASTES DELETED SECTION 804 MATERIALS, JOINTS AND CONNECTIONS DELETED |
753 | CHAPTER 9 VENTS SECTION 901 GENERAL SECTION 902 MATERIALS SECTION 903 OUTDOOR VENT EXTENSION SECTION 904 VENT TERMINALS |
754 | SECTION 905 VENT CONNECTIONS AND GRADES SECTION 906 FIXTURE VENTS TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION 907 INDIVIDUAL VENT SECTION 908 COMMON VENT TABLE 908.3 COMMON VENT SIZES SECTION 909 WET VENTING |
755 | TABLE 909.3 WET VENT SIZE TABLE 909.4 SIZE OF VENT STACK SECTION 910 WASTE STACK VENT TABLE 910.4 WASTE STACK VENT SIZE |
756 | SECTION 911 CIRCUIT VENTING SECTION 912 COMBINATION WASTE DRAIN AND VENT SYSTEM DELETED SECTION 913 ISLAND FIXTURE VENTING SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS DELETED SECTION 915 VENTS FOR STACK OFFSETS DELETED SECTION 916 VENT PIPE SIZING |
757 | TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS SECTION 917 AIR ADMITTANCE VALVES DELETED SECTION 918 ENGINEERED VENT SYSTEMS DELETED SECTION 919 COMPUTERIZED VENT DESIGN DELETED SECTION 920 SINGLE STACK PLUMBING SYSTEMS (SOVENT) |
759 | CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS SECTION 1003 INTERCEPTORS AND SEPARATORS DELETED SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS |
761 | CHAPTER 11 STORM DRAINAGE DELETED |
763 | CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS DELETED |
765 | CHAPTER 13 REFERENCED STANDARDS ANSI AHRI ASME |
766 | ASSE |
768 | ASTM |
770 | AWS AWWA |
771 | CISPI CSA |
772 | ICC ISEA NFPA |
773 | NSF PDI UL |
775 | APPENDIX A PLUMBING PERMIT FEE SCHEDULE |
777 | APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES |
779 | APPENDIX C GRAY WATER RECYCLING SYSTEMS SECTION C101 GENERAL SECTION C102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS |
780 | SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS DELETED |
781 | FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION |
782 | FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS |
783 | APPENDIX C1 RAIN WATER RECYCLING SYSTEMS SECTION C1-101 GENERAL SECTION C1-102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS |
785 | APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES DELETED |
787 | APPENDIX E SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL SECTION E102 INFORMATION REQUIRED SECTION E103 SELECTION OF PIPE SIZE |
791 | TABLE E.1 TABLE E.2 |
792 | FIGURE E103.3(1) EXAMPLE-SIZING |
793 | TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS |
794 | TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURES |
795 | TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND |
796 | TABLE E103.3(3)—CONTINUED TABLE FOR ESTIMATING DEMAND TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (PSI) |
797 | TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (FEET) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEA (FEET) |
798 | FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPE (TYPE K, ASTM B 88 COPPER TUBING) |
799 | FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPE (TYPE L, ASTM B 88 COPPER TUBING) |
800 | FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPE (TYPE M, ASTM B 88 COPPER TUBING) |
801 | FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPE |
802 | FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPE |
803 | FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPE |
804 | SECTION E201 SELECTION OF PIPE SIZE SECTION E202 DETERMINATION OF PIPE VOLUMES |
805 | TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (W.S.F.U.) |
806 | TABLE E201.1—CONTINUED MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (W. |
807 | TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING |
809 | APPENDIX F STRUCTURAL SAFETY SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS |
811 | APPENDIX G VACUUM DRAINAGE SYSTEM SECTION G101 VACUUM DRAINAGE SYSTEM |
813 | APPENDIX H RODENTPROOFING |
815 | PART VIII — ELECTRICAL CHAPTERS CHAPTERS 34 THROUGH 43 DELETED |
817 | PART VIII 2012 NORTH CAROLINA STATE BUILIDNG CODE: ELECTRICAL CODE ABRIDGED FOR RESIDENTIAL CODE (2011 NEC® WITH NORTH CAROLINA AMENDMENTS) |
819 | TABLE OF CONTENTS |
823 | ARTICLE 10 – ADMINISTRATIVE SECTION 10.1 TITLE 10.2 SCOPE 10.3 PURPOSE 10.4 ADMINISTRATION 10.5 DEFINITION 10.6 APPLICATION OF CODE TO EXISTING BUILDINGS 10.7 SERVICE UTILITIES |
824 | 10.8 TEMPORARY POWER 10.9 REQUIREMENTS OF OTHER STATE AGENCIES OCCUPATIONAL LICENSING BOARDS OR COMMISSIONS |
825 | AMENDMENT 210.8(A)(3) |
826 | AMENDMENT 250.50 |
827 | AMENDMENT 334.15(C) |
829 | PART IX—REFERENCED STANDARDS CHAPTER 44 REFERENCED STANDARDS AAMA ACI ACCA |
830 | AFPA AISI AITC ANSI |
831 | APA APSP |
832 | ASCE/SEI ASHRAE ASME |
833 | ASSE |
834 | ASTM |
842 | AWPA AWS AWWA CGSB |
843 | CISPI CPA CPSC CSA |
844 | CSSB DASMA |
845 | DOC DOTn FEMA FM GA |
846 | HPVA ICC ISO MSS NAIMA |
847 | NCMA NFPA NFRC NSF |
848 | PCA SMACNA TMS TPI UL |
849 | ULC US-FTC |
850 | WDMA |
851 | CHAPTER 45 HIGH WIND ZONES SECTION R4501 GENERAL SECTION R4502 DESIGN PRESSURE FOR DOORS AND WINDOWS TABLE R4502(A) DESIGN PRESSURES FOR DOORS AND WINDOWSA, TABLE R4502(B) DESIGN PRESSURES (IN PSF) GARAGE DOORS SECTION R4503 FOOTINGS TABLE R4503.2.1 FOOTINGS TO RESIST UPLIFT FROM PIERS IN 120 AND 130 MPH WIND ZONES SUPPORTING GIRDERS IN EXTERIOR WALLS |
852 | SECTION R4504 WALL AND FOUNDATION ANCHORAGE TABLE R4504.1 STRUCTURAL ANCHORAGE TABLES R4504.1.1 WALL REINFORCEMENT OR CONTINUOUS ANCHORAGE SECTION R4505 WALL CONSTRUCTION |
853 | TABLE R4505(A) STUDS IN 110, 120, AND 130 MPH ZONES TABLE R4505(B) |
854 | SECTION R4506 STRUCTURAL BRACING SECTION R4507 MASONRY WALL CONSTRUCTION TABLE R4507.1A H/T LATERAL SUPPORT RATIOS FOR UNREINFORCED EXTERIOR MASONRY WALLS |
855 | TABLE R4507.1B H/T LATERAL SUPPORT RATIOS FOR UNREINFORCED EXTERIOR MASONRY WALLS SECTION R4508 ROOF TIE DOWN TABLE R4508.2 ROOF TIE DOWN REQUIREMENTS ALONG EXTERIOR WALLS (PLF) TABLE R4508.4 UPLIFT CAPACITY OF WOOD STRUCTURAL PANEL SHEATHING USED TO RESIST BOTH LATERAL LOAD AND UPLIFT |
856 | FIGURE R4504.3(A) CONTINUOUS VENEER PIER/CURTAIN WALL |
857 | FIGURE R4504.3(B) CONTINUOUS VENEER PIER/CURTAIN WALL |
858 | FIGURE R4504.3(C) VENEER SHIRT WALL PIER/CURTAIN WALL |
859 | FIGURE R4504.3(D) VENEER SHIRT WALL PIER/CURTAIN WALL |
860 | FIGURE R4506.5 GABLE ENDWALL BALLOON FRAMING PREFERRED METHOD |
861 | FIGURE R4506.7(A) OVERHANG AT ENDWALLS |
862 | FIGURE R4506.7A—CONTINUED OVERHANG AT ENDWALLS |
863 | FIGURE R4506.7B GABLE END OVERHANG |
864 | FIGURE R4506.7(C) GABLE END OVERHANG |
865 | FIGURE R4506.8 ROOF SHEATHING ATTACHMENT PLAN |
866 | FIGURE R4507.1(A) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION WHERE WIND ZONES ARE 120 MPH OR GREATER |
867 | FIGURE R4507.1(B) REQUIREMENTS FOR REINFORCED HOLLOW-UNIT MASONRY CONSTRUCTION WHERE WIND ZONES ARE 120 MPH OR GREATER |
868 | FIGURE R4508.4 PANEL ATTACHMENT TO COUNTER UPLIFT HORIZONTAL OR VERTICAL |
869 | CHAPTER 46 COASTAL AND FLOOD PLAIN CONSTRUCTION STANDARDS SECTION R4601 PURPOSE, APPLICATION AND SCOPE SECTION R4602 DEFINITIONS SECTION R4603 PILING STANDARDS |
870 | FIGURE R4603.6(A) ELEVATIONS (SHOWING POSSIBLE ARRANGEMENT OF X-BRACING IN LINE) (G AND H SIMILAR) FIGURE R4603.6(B) ELEVATIONS (SHOWING POSSIBLE ARRANGEMENT OF X-BRACING IN LINE) (G AND H SIMILAR) |
871 | FIGURE R4605.3(A) TWO-STORY WALL SECTION (TYPICAL) |
872 | FIGURE R4605.3(B) |
873 | SECTION R4604 ELEVATION STANDARDS SECTION R4605 CONSTRUCTION MATERIALS AND METHODS STANDARDS |
874 | TABLE R4605.5A CORROSION RESISTANCE (APPLIES ONLY TO STRUCTURE LOCATED IN COASTAL HIGH-HAZARD AREAS AND OCEAN HAZARD AREAS) |
875 | APPENDIX A SIZING AND CAPACITIES OF GAS PIPING DELETED |
877 | APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED |
879 | APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS DELETED |
881 | APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION DELETED |
883 | APPENDICES E-1 THROUGH E-4 RESIDENTIAL REQUIREMENTS APPENDIX E-1 ENERGY EFFICIENCY CERTIFICATE (SECTION N1101.9) |
884 | APPENDIX E-2 INSULATION AND AIR SEALING DETAILS APPENDIX E-2.1 |
885 | APPENDIX E-2.2 FIGURE INSULATION INSTALLATIONS |
886 | APPENDIX E-2.3 FIGURE SECTION VIEW OF BATH TUB ON EXTERIOR WALL |
887 | FIGURE SECTION VIEW OF SHOWER ON EXTERIOR WALL |
888 | FIGURE SECTION VIEW OF INTERIOR STAIRCASE ON EXTERIOR WALL(OPTION 1) |
889 | FIGURE SECTION VIEW OF INTERIOR STAIRCASE ON EXTERIOR WALL(OPTION 2) |
890 | FIGURE SECTION VIEW OF DIRECT VENT GAS FIREPLACE |
891 | FIGURE SECTION VIEW OF WALL ADJOINING ATTIC SPACE |
892 | FIGURE SECTION VIEW OF WALL ADJOINING ATTIC SPACE FIGURE SECTION VIEW OF WALL ADJOINING ATTIC SPACE |
893 | APPENDIX E-2.4 FIGURE ISOMETRIC VIEW OF DIMENSIONAL LUMBER FLOOR/CEILING SYSTEM ABOVE COMMON WALL BETWEEN UNCONDITIONED AND CONDITIONED SPACE |
894 | FIGURE ISOMETRIC VIEW OF WOOD TRUSS FLOOR/CEILING SYSTEM ABOVE COMMON WALL BETWEEN UNCONDITIONED AND CONDITIONED SPACE |
895 | FIGURE ISOMETRIC VIEW OF I-JOIST FLOOR/CEILING SYSTEM ABOVE COMMON WALL BETWEEN UNCONDITIONED AND CONDITIONED SPACE |
896 | FIGURE SECTION VIEWS OF DUCT PENETRATING INTO ATTIC |
897 | FIGURE SECTION VIEW OF SOFFIT OVER CABINET |
898 | FIGURE SECTION VIEW OF FLOOR HVAC BOOT PENETRATION |
899 | FIGURE SECTION VIEW OF CEILING HVAC BOOT PENETRATION |
900 | APPENDIX E-3: SAMPLE WORKSHEETS FOR RESIDENTIAL AIR AND DUCT LEAKAGE TESTING APPENDIX E-3A: AIR SEALING: VISUAL INSPECTION OPTION (SECTION N1102.4.2.1) SAMPLE WORKSHEET TABLE N1102.4.2 AIR BARRIER INSPECTION |
901 | APPENDIX E-3B AIR SEALING: TESTING OPTION (SECTION N1102.4.2.2) SAMPLE WORKSHEET |
902 | APPENDIX E-3C DUCT SEALING. DUCT AIR LEAKAGE TEST (SECTION N1103.2.2) SAMPLE WORKSHEET |
903 | APPENDIX E-4 ADDITIONAL VOLUNTARY CRITERIA FOR INCREASING ENERGY EFFICIENCY (HIGH EFFICIENCY RESIDENTIAL OPTION) TABLE E-4A OPTIONAL INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT 3. TABLE E-4B EQUIVALENT U-FACTORS |
904 | TABLE E-4C: SAMPLE CONFIRMATION FORM FOR ADDITIONAL VOLUNTARY CRITERIA FOR INCREASING ENERGY EFFICIENCY (HIGH EFFICIENCY RESIDEN |
905 | E-4D: SAMPLE WORKSHEETS FOR RESIDENTIAL AIR AND DUCT LEAKAGE TESTING E-4D.1 AIR SEALING: VISUAL INSPECTION OPTION (SECTION N1102.4.2.1) SAMPLE WORKSHEET FOR ALTERNATIVE RESIDENTIAL ENERGY CODE FOR HIGHER EFFICIENCY TABLE N1102.4.2 AIR BARRIER INSPECTION |
906 | E-4D.2 AIR SEALING: TESTING OPTION (SECTION N1102.4.2.2) SAMPLE WORKSHEET FOR ALTERNATIVE RESIDENTIAL ENERGY CODE FOR HIGHER EFF |
907 | E-4D.3 DUCT SEALING. DUCT AIR LEAKAGE TEST (SECTION N1103.2.2) SAMPLE WORKSHEET FOR ALTERNATIVE RESIDENTIAL ENERGY CODE FOR HIGH |
909 | APPENDIX F RADON CONTROL METHODS DELETED |
911 | APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 GENERAL SECTION AG102 DEFINITIONS SECTION AG103 SWIMMING POOLS SECTION AG104 SPAS AND HOT TUBS SECTION AG105 BARRIER REQUIREMENTS |
912 | SECTION AG106 ENTRAPMENT PROTECTION FOR SWIMMING POOL AND SPA SUCTION OUTLETS |
913 | SECTION AG107 ABBREVIATIONS SECTION AG108 STANDARDS ANSI/NSPI ANSI/APSP ASCE ASTM UL |
915 | APPENDIX H PATIO COVERS DELETED |
917 | APPENDIX I PRIVATE SEWAGE DISPOSAL DELETED |
919 | [EB] APPENDIX J EXISTING BUILDINGS AND STRUCTURES DELETED |
921 | APPENDIX K SOUND TRANSMISSION SECTION AK101 GENERAL SECTION AK102 AIR-BORNE SOUND SECTION AK103 STRUCTURAL-BORNE SOUND SECTION AK104 REFERENCED STANDARDS |
923 | APPENDIX L PERMIT FEES DELETED |
925 | APPENDIX M WOOD DECKS SECTION AM101 GENERAL SECTION AM102 FOOTERS FIGURE AM102 TABLE AM102.1 FOOTING TABLE SECTION AM103 FLASHING |
926 | FIGURE AM102.1 FIGURE AM103 SECTION AM104 DECK ATTACHMENT SECTION AM105 GIRDER SUPPORT AND SPAN SECTION AM106 JOIST SPANS AND CANTILEVERS |
927 | FIGURE AM105 TOP MOUNT/FLUSH FIGURE AM105.1 SIDE MOUNT DROPPED GIRDER FIGURE AM105.2 SPLIT GIRDER DETAIL FIGURE AM105.3 CANTILEVERED DROPPED GIRDER DETAIL SECTION AM107 FLOOR DECKING SECTION AM108 POST HEIGHT |
928 | SECTION AM109 DECK BRACING FIGURE AM109 FIGURE AM109.1 FIGURE AM109.2 FIGURE AM109.3 |
929 | SECTION AM110 STAIRS FIGURE AM110 SECTION AM111 HANDRAILS, GUARDS AND GENERAL FIGURE AM111 |
930 | FIGURE AM112 WALKWAYS OVER DUNES OR BERMS IN OCEAN HAZARD AREAS |
931 | APPENDIX N BASIC LOAD ESTIMATING FIGURE PLAN VIEW |
933 | TABLE N-1 WOOD BEAMS AND GIRDERS (19%) #2 GRADE, ALLOWABLE LOADS IN POUNDS PER LINEAR FOOT SIMPLE SPAN, DEFLECTION = L/360, LOAD DURATION FACTOR 1.0, ADEQUATE BEARING AND LATERAL SUPPORT MUST BE PROVIDED |
934 | TABLE N-2 FLITCH PLATE BEAMS-DESIGN VALUES AND ASSUMPTIONS |
935 | APPENDIX O FOAM PLASTIC DIAGRAMS FIGURE O-1 FOUNDATION WALL |
936 | FIGURE O-2 BASEMENT WALL |
937 | FIGURE O-3 FRAME WALL |
938 | FIGURE O-4 FRAME WALL |
939 | APPENDIX P DWELLING UNIT FIRE SPRINKLER SYSTEMS SECTION P2904 DWELLING UNIT FIRE SPRINKLER SYSTEMS TABLE P2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED |
941 | EQUATION 29-1 |
943 | TABLE P2904.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc) |
944 | TABLE P2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm) TABLE P2904.6.2(3) ELEVATION LOSS (PLe) |
945 | TABLE P2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING |
946 | TABLE P2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING |
947 | TABLE P2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE |
948 | TABLE P2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE |
949 | TABLE P2904.6.2(8) ALLOWABLE PIPE LENGTH FOR ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX TUBING |
950 | TABLE P2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX TUBING |
951 | APPENDIX Q FIGURE APP. Q-DISCONTINUOUS FOOTING DETAIL FOR GARAGE OR PORCH WALLS FOUNDATION WALL EXTENSION DETAIL |
952 | FIGURE APP. Q-DISCONTINUOUS FOOTING DETAIL FOR GARAGE OR PORCH WALLS PLASTER DETAIL |
953 | INDEX |
965 | HELPFUL CODE TOOLS FROM ICC |