NC ResidentialCode 2018 1stPrint
$79.08
North Carolina State Building Code: Residential Code 2018
Published By | Publication Date | Number of Pages |
NC | 2018 | 59 |
This is a fully integrated code based on the 2015 International Residential Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | R101.2 Scope. Exceptions: R101.2 Scope. Exceptions: |
2 | R101.2.2 Accessory structures. Exception: R102.5 Appendices. ACCESSORY BUILDING. ACCESSORY STRUCTURE. |
3 | AIR-IMPERMEABLE INSULATION. [RB] DWELLING. [RB] DWELLING UNIT. EGRESS ROOF ACCESS WINDOW. FAMILY. |
4 | FARM BUILDING. LANDING PLATFORM. LOFT. LANDING PLATFORM. LOFT. LIVE/WORK UNIT. |
5 | PRIVATE POND. [RB] TOWNHOUSE. TOWNHOUSE. |
6 | TABLE R302.1 EXTERIOR WALLS EXTERIOR WALL ELEMENT MINIMUM FIRE-RESISTANCE RATING MINIMUM FIRE SEPARATION DISTANCE |
7 | R302.1.1 Soffit protection. 10 5 Exceptions: 10 5 |
8 | R302.2 Townhouses. Exception: R302.2.1 Double walls. R302.2.2 Common Walls. R302.2.5 Townhouse eave protection. |
9 | R305.1 Minimum height. Exceptions: Section R305 Ceiling Height R305.1 Minimum height. Exceptions: |
10 | Section R310 Emergency Escape and Rescue Openings R310.2.6 Egress roof access window. R311.2 Egress door. R311.7.4 |
11 | R311.7.5.2.1 R311.7.5.3 Nosings. Exceptions: R311.7.8.1 Height. Exceptions: |
12 | R312.1.2 Height. Exceptions: R312.1.3 Opening limitations. Exceptions: |
13 | R313.1 Townhouse automatic fire sprinkler systems. Exceptions: SECTION R327 DOCKS, PIERS, BULKHEADS AND WATERWAY STRUCTURES R327.1 General. Exceptions: |
14 | Section R328 Lofts R328.1 Minimum loft area and dimensions. R328.1.1 Minimum area. R328.1.2 Maximum area. R328.1.3 Minimum dimensions. R328.1.4 Height effect on loft area. Exception: R328.2 Loft access. R328.2.1 Stairways. R328.2.1.1 Width. |
15 | R328.2.1.2 Headroom. R328.2.1.3 Treads and Risers. R328.2.1.4 Landing platforms. R328.2.1.5 Handrails. R328.2.1.6 Stairway guards. R328.2.2 Ladders. R328.2.2.1 Size and capacity. R328.2.2.2 Incline. R328.2.4 Ships ladders. R328.2.5 Loft Guards. |
16 | Section R328 Lofts R328.1 Minimum loft area and dimensions. R328.1.1 Minimum area. R328.1.2 Maximum area. R328.1.3 Minimum dimensions. R328.1.4 Height effect on loft area. Exception: R328.2 Loft access. R328.2.1 Stairways. R328.2.1.1 Width. R328.2.1.2 Headroom. R328.2.1.3 Treads and Risers. R328.2.1.4 Landing platforms. R328.2.1.5 Handrails. R328.2.1.6 Stairway guards. R328.2.2 Ladders. R328.2.2.1 Size and capacity. |
17 | R328.2.2.2 Incline. R328.2.4 Ships ladders. R328.2.5 Loft Guards. |
18 | ERRATA – Changed Section number from R328 to R329 because R328 was already used SECTION R329 DEMOLITION R328.1 Demolition. Exceptions: R404.4 Retaining walls. |
19 | R506.2.1 Fill. Exception: |
21 | TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa, STUD SIZE (inches) BEARING WALLS NONBEARING WALLS Laterally unsupported stud heighta (feet) Maximum spacing when supporting a ro |
22 | ERRATA – moved superscript “b” adjacent to “southern pine” TABLE R602.7(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING TABLE R602.7(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southe |
23 | ERRATA – added highlighted figures to Tables R602.7(1) and R602.7(2) on pages 127-129. |
26 | TABLE R602.7.5 MINIMUM NUMBER OF FULL HEIGHT KING STUDS AT EACH END OF HEADERS IN EXTERIOR WALLS HEADER SPAN (feet) MAXIMUM STUD HEADER SPAN (feet) MINIMUM NUMBER OF FULL HEIGHT STUDS (King) |
27 | ERRATA – corrected jack stud reference in Figure R602.10.1 – Method PF-Portal Frame Construction on page 134. FIGURE R602.10.1 M |
28 | TABLE R602.10.1 BRACING METHODSa, Notes: |
29 | Table R602.10.3 REQUIRED LENGTH OF BRACING ALONG EACH SIDE OF A CIRCUMSCRIBED RECTANGLEa, |
32 | R703.8.2.1 Support by steel angle. FIGURE R703.8.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES |
33 | FIGURE R703.8.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBER |
34 | R703.8.2.1 Support by steel angle. R905.2.8.5 Drip Edge. R908.3 Roof replacement. |
35 | N1101.1 Scope. Exception: N1101.13 (R401.2) Compliance. N1102.1.2, N1102.1.4, R&U-Value Tables. (170613 Item B-13) The Agency withdrew this item due to RRC February 15, 2018 objection. |
36 | SECTION N1106 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE N1106.1 Scope. N1106.2 Mandatory requirements. Exception: N1106.5 Verification by approved agency. |
37 | N1106.2 Mandatory requirements. Exception: TABLE N1106.2.1 MINIMUM INSULATION AND FENESTRATION REQUIREMENTS FOR ENERGY RATING INDEX COMPLIANCEa |
38 | TABLE N1106.2.2 EQUIVALENT U-FACTORS FOR TABLE N1106.2.1a |
39 | M1402.1 (918.1) General. M1403.1 (918.2) Heat pumps. M1411.3.2 Drain pipe materials and sizes. |
40 | M1502.1 General. M1502.1.1 (504.6) Makeup air. M1502.4.2 Duct installation. M1602.3 (603.18) Return-air intake (nonengineered systems). |
41 | ERRATA – remove “or pan” from P2503.6 heading as shown below P2503.6 Shower liner test. (no change to the section requirements) P2603.5 Freezing. Note: P2603.5.2 Frost protection. P2604.1.4 Tracer wire. |
42 | ERRATA – change Section reference to P2906.4.1 P3002.2.1 (703.1) Building sewer pipe near the water service. ERRATA – change Section reference to P3110 P3101.2.1 (901.2.1) Venting required. ERRATA – change Section references to P3104.2 and P3102.5 P3109.3 (913.3) Stack vent. P3201.3 (1002.7) Trap setting and protection. |
43 | ERRATA – Section P2708.2 (417.3) requires 2” minimum trap as shown below. ERRATA – change Section reference to P2706.1.2 in Exception #3. P3201.6 (1002.1) Number of fixtures per trap. Exceptions: |
44 | ANCE ASHRAE CSA UL |
45 | SECTION R4602 DEFINITIONS COASTAL HIGH HAZARD AREA. CORROSION RESISTANCE AREA. OCEAN HAZARD AREA. |
46 | R4603.6.1 Tying at corners. R4603.6.2 Bracing of Pilings. |
49 | R4603.6 Tying and bracing of wood piles. Table R4603.6 Minimum Fastening of Beams and Girders to Pilings R4603.6.1 Tying at corners. R4603.6.2 Bracing of Pilings. |
51 | SECTION R4606 FASTENER CORROSION RESISTANCE R4605.5 R4606.1 Fastener corrosion resistance. TABLE R4605.5a R4606.1a CORROSION RESISTANCE OPEN (exterior, porches, under house) EXPOSURE LEVEL VENTED/ENCLOSED (attic, floor R4605.6 R4605.5 Building anchorage. |
52 | R4605.7 R4605.6 Insulation. R4605.8 R4605.7 Accessory structures. AM105.1 General. Table AM105.1 Girder Connection to Side of Post |
53 | AM109.1 Deck bracing. AM109.1.1. Lateral bracing not required. AM109.1.2. Knee bracing. TABLE AM109.1 FASTENING OF BRACE TO POST AND GIRDER/BAND (CHOOSE ONE) AM109.1.3. Post embedment. TABLE AM109.1 AM109.2 POST EMBEDMENT FOR FREE STANDING DECKS POST SIZE MAXIMUM TRIBUTARY AREA MAXIMUM POST HEIGHT EMBEDMENT DEPT AM109.1.4. Cross bracing. AM109.1.5. Piles in coastal regions. |
55 | AM109.1.4 Cross bracing. Table AM109.1.4 FASTENING OF BRACE (CHOOSE ONE) Fastener Type Diameter (inches) QTY Length |
56 | ERRATA – Figure AM109.1(4) corrected bracing location and lapping (200708). |
57 | APPENDIX Q TINY HOUSES SECTION AQ101 GENERAL AQ101.1 Scope. SECTION AQ102 DEFINITIONS AQ102.1 General. LANDING PLATFORM. HABITABLE LOFT. TINY HOUSE. SECTION AQ103 LOFTS AQ103.1 General. AQ103.1.1 Minimum area. AQ103.1.2 Minimum dimensions. AQ103.1.3 Minimum ceiling height. Exception: AQ104.1.4 Height effect on loft area. Exception: SECTION AQ104 MEANS OF EGRESS AQ104.1 Loft access. AQ104.2.1 Stairways. AQ104.2.1.1 Width. AQ104.2.1.2 Headroom. |
58 | AQ104.2.1.3 Treads and risers. AQ104.2.1.4 Landing platforms. AQ104.2.1.5 Handrails. AQ104.2.1.6 Stairway guards. AQ104.2.2 Ladders. Exception: AQ104.2.2.1 Size and capacity. AQ104.2.3 Ship’s ladders. AQ104.2.4 Loft Guards. SECTION AQ105 EMERGENCY ESCAPE AND RESCUE AS105.1 Emergency Escape and Rescue. SECTION AQ106 SMOKE AND CARBON MONOXIDE DETECTORS AQ106.1 Smoke and Carbon monoxide detectors. SECTION AQ107 FOUNDATION AQ107.1 Foundation options. AQ107.1.1 Wood Foundation. AQ107.1.2. Anchorage. Exception: |