Major changes and an expanded scope make the 2018 edition of NFPA 101®: Life Safety Code® essential in any occupancy — from assembly to health care, industrial, and residential. As the built environment and risks evolve, so do the challenges to protect people from fire and related hazards. NFPA®’s Life Safety Code is the most widely used source for strategies for occupant safety throughout the life of a building. Vital for architects, engineers, building owners and building managers, hospital administrators, and AHJs, NFPA 101 covers it all: Egress, sprinklers, alarms, emergency lighting, smoke barriers, special hazard protection, and much more. For the 2018 edition, the scope of NFPA 101 is expanded to include hazardous materials emergencies, injuries from falls, and emergency communications. The Code provides a flexible approach that adapts to nontraditional use of buildings; innovative designs; and new technologies, materials, and construction practices. It addresses life safety in both new and existing structures. Significant changes for the 2018 edition include: New requirements for hazardous materials protection of other than fire-related hazards (Chapter 8) A new reference to NFPA 4 for integrated fire protection and life safety system testing, and new provisions for risk analyses for mass notification systems (Chapter 9) Animal housing facilities added as special structures (Chapter 11) Added requirements for carbon-monoxide detection in new assembly occupancies and new residential board and care occupancies (Chapters 12 and 32) Added criteria for door locking to prevent unwanted entry in educational, day care, and business occupancies (Chapters 14-17, 38, and 39) A mandatory sprinkler requirement for all but very small new educational occupancies (Chapter 14) New provisions that permit health care and ambulatory health care smoke compartments up to 40,000 ft2 (3720 m2) in area (Chapters 18 and 19) Added requirements for bathtub and shower grab bars, which are then referenced by numerous occupancy chapters (Chapter 24) Added requirements for attic protection requirements that impact certain new hotels and dormitories and apartment buildings (Chapters 28 and 30) A new reference to NFPA 99 for medical gases in business occupancies (Chapters 38 and 39) A new Annex C that offers guidance on several NFPA® hazardous materials standards to assist users with the new hazardous materials protection requirements Be sure your knowledge is up-to-date and your facilities meet code. Base your decisions on the 2018 edition of NFPA 101 and tackle safety challenges effectively.

PDF Catalog

PDF Pages PDF Title
26 Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Application.
1.4 Equivalency.
27 1.5 Units and Formulas.
1.6 Enforcement.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
28 2.3 Other Publications.
30 2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
43 Chapter 4 General
4.1 Goals.
4.2 Objectives.
4.3 Assumptions.
4.4 Life Safety Compliance Options.
4.5 Fundamental Requirements.
44 4.6 General Requirements.
47 4.7 Fire Drills.
4.8 Emergency Action Plan.
Chapter 5 Performance-Based Option
5.1 General Requirements.
48 5.2 Performance Criteria.
5.3 Retained Prescriptive Requirements.
5.4 Design Specifications and Other Conditions.
49 5.5 Design Fire Scenarios.
50 5.6 Evaluation of Proposed Designs.
5.7 Safety Factors.
5.8 Documentation Requirements.
51 Chapter 6 Classification of Occupancy and Hazard of Contents
6.1 Classification of Occupancy.
55 6.2 Hazard of Contents.
Chapter 7 Means of Egress
7.1 General.
57 7.2 Means of Egress Components.
83 7.3 Capacity of Means of Egress.
86 7.4 Number of Means of Egress.
7.5 Arrangement of Means of Egress.
88 7.6 Measurement of Travel Distance to Exits.
7.7 Discharge from Exits.
89 7.8 Illumination of Means of Egress.
90 7.9 Emergency Lighting.
91 7.10 Marking of Means of Egress.
93 7.11 Special Provisions for Occupancies with High Hazard Contents.
7.12 Special Provisions for Hazardous Materials.
7.13 Mechanical Equipment Rooms, Boiler Rooms, and Furnace Rooms.
94 7.14 Normally Unoccupied Building Service Equipment Support Areas.
95 7.15 Occupant Evacuation Elevators.
97 Chapter 8 Features of Fire Protection
8.1 General.
8.2 Construction and Compartmentation.
98 8.3 Fire Barriers.
103 8.4 Smoke Partitions.
8.5 Smoke Barriers.
105 8.6 Vertical Openings.
108 8.7 Special Hazard Protection.
109 8.8 Inspection and Testing of Door Assemblies.
Chapter 9 Building Service and Fire Protection Equipment
9.1 Utilities.
110 9.2 Heating, Ventilating, and Air-Conditioning.
9.3 Smoke Control.
9.4 Elevators, Escalators, and Conveyors.
111 9.5 Waste Chutes, Incinerators, and Laundry Chutes.
9.6 Fire Detection, Alarm, and Communications Systems.
114 9.7 Automatic Sprinklers.
9.8 Other Automatic Extinguishing Equipment.
115 9.9 Portable Fire Extinguishers.
9.10 Standpipe Systems.
9.11 Fire Protection System Operating Features.
9.12 Carbon Monoxide (CO) Detection and Warning Equipment.
9.13 Special Inspections and Tests.
9.14 Risk Analysis for Mass Notification Systems.
116 Chapter 10 Interior Finish, Contents, and Furnishings
10.1 General.
10.2 Interior Finish.
119 10.3 Contents and Furnishings.
120 Chapter 11 Special Structures and High-Rise Buildings
11.1 General Requirements.
11.2 Open Structures.
121 11.3 Towers.
124 11.4 Water-Surrounded Structures.
11.5 Piers.
125 11.6 Vehicles and Vessels.
11.7 Underground Structures and Limited Access Structures.
126 11.8 High-Rise Buildings.
127 11.9 Permanent Membrane Structures.
128 11.10 Temporary Membrane Structures.
130 11.11 Tents.
131 11.12 Animal Housing Facilities.
Chapter 12 New Assembly Occupancies
12.1 General Requirements.
133 12.2 Means of Egress Requirements.
140 12.3 Protection.
142 12.4 Special Provisions.
152 12.5 Building Services.
12.6 Reserved.
12.7 Operating Features.
156 Chapter 13 Existing Assembly Occupancies
13.1 General Requirements.
157 13.2 Means of Egress Requirements.
165 13.3 Protection.
167 13.4 Special Provisions.
176 13.5 Building Services.
13.6 Reserved.
13.7 Operating Features.
180 Chapter 14 New Educational Occupancies
14.1 General Requirements.
14.2 Means of Egress Requirements.
182 14.3 Protection.
185 14.4 Special Provisions.
14.5 Building Services.
14.6 Reserved.
14.7 Operating Features.
186 Chapter 15 Existing Educational Occupancies
15.1 General Requirements.
187 15.2 Means of Egress Requirements.
189 15.3 Protection.
191 15.4 Special Provisions.
192 15.5 Building Services.
15.6 Reserved.
15.7 Operating Features.
Chapter 16 New Day-Care Occupancies
16.1 General Requirements.
194 16.2 Means of Egress Requirements.
196 16.3 Protection.
197 16.4 Special Provisions.
16.5 Building Services.
198 16.6 Day-Care Homes.
200 16.7 Operating Features.
Chapter 17 Existing Day-Care Occupancies
17.1 General Requirements.
202 17.2 Means of Egress Requirements.
204 17.3 Protection.
205 17.4 Special Provisions.
206 17.5 Building Services.
17.6 Day-Care Homes.
208 17.7 Operating Features.
209 Chapter 18 New Health Care Occupancies
18.1 General Requirements.
212 18.2 Means of Egress Requirements.
218 18.3 Protection.
223 18.4 Special Provisions.
225 18.5 Building Services.
226 18.6 Reserved.
18.7 Operating Features.
228 Chapter 19 Existing Health Care Occupancies
19.1 General Requirements.
231 19.2 Means of Egress Requirements.
237 19.3 Protection.
243 19.4 Special Provisions.
19.5 Building Services.
244 19.6 Reserved.
19.7 Operating Features.
247 Chapter 20 New Ambulatory Health Care Occupancies
20.1 General Requirements.
248 20.2 Means of Egress Requirements.
250 20.3 Protection.
252 20.4 Special Provisions.
253 20.5 Building Services.
20.6 Reserved.
20.7 Operating Features.
255 Chapter 21 Existing Ambulatory Health Care Occupancies
21.1 General Requirements.
256 21.2 Means of Egress Requirements.
258 21.3 Protection.
260 21.4 Special Provisions.
261 21.5 Building Services.
21.6 Reserved.
21.7 Operating Features.
263 Chapter 22 New Detention and Correctional Occupancies
22.1 General Requirements.
265 22.2 Means of Egress Requirements.
267 22.3 Protection.
270 22.4 Special Provisions.
274 22.5 Building Services.
22.6 Reserved.
22.7 Operating Features.
275 Chapter 23 Existing Detention and Correctional Occupancies
23.1 General Requirements.
278 23.2 Means of Egress Requirements.
280 23.3 Protection.
283 23.4 Special Provisions.
285 23.5 Building Services.
23.6 Reserved.
23.7 Operating Features.
286 Chapter 24 One- and Two-Family Dwellings
24.1 General Requirements.
287 24.2 Means of Escape Requirements.
289 24.3 Protection.
290 24.4 Reserved.
24.5 Building Services.
Chapter 25 Reserved
Chapter 26 Lodging or Rooming Houses
26.1 General Requirements.
291 26.2 Means of Escape Requirements.
26.3 Protection.
293 26.4 Reserved.
26.5 Building Services.
26.6 Reserved.
26.7 Operating Features.
Chapter 27 Reserved
Chapter 28 New Hotels and Dormitories
28.1 General Requirements.
294 28.2 Means of Egress Requirements.
296 28.3 Protection.
298 28.4 Special Provisions.
28.5 Building Services.
28.6 Reserved.
28.7 Operating Features.
299 Chapter 29 Existing Hotels and Dormitories
29.1 General Requirements.
300 29.2 Means of Egress Requirements.
301 29.3 Protection.
303 29.4 Special Provisions.
304 29.5 Building Services.
29.6 Reserved.
29.7 Operating Features.
Chapter 30 New Apartment Buildings
30.1 General Requirements.
305 30.2 Means of Egress Requirements.
307 30.3 Protection.
309 30.4 Special Provisions.
310 30.5 Building Services.
30.6 Reserved.
30.7 Operating Features.
Chapter 31 Existing Apartment Buildings
31.1 General Requirements.
311 31.2 Means of Egress Requirements.
313 31.3 Protection.
316 31.4 Special Provisions.
31.5 Building Services.
31.6 Reserved.
31.7 Operating Features.
Chapter 32 New Residential Board and Care Occupancies
32.1 General Requirements.
317 32.2 Small Facilities.
321 32.3 Large Facilities.
327 32.4 Suitability of an Apartment Building to House a Board and Care Occupancy.
32.5 Reserved.
32.6 Reserved.
32.7 Operating Features.
328 Chapter 33 Existing Residential Board and Care Occupancies
33.1 General Requirements.
329 33.2 Small Facilities.
334 33.3 Large Facilities.
341 33.4 Suitability of an Apartment Building to House a Board and Care Occupancy.
342 33.5 Reserved.
33.6 Reserved.
33.7 Operating Features.
343 Chapter 34 Reserved
Chapter 35 Reserved
Chapter 36 New Mercantile Occupancies
36.1 General Requirements.
344 36.2 Means of Egress Requirements.
346 36.3 Protection.
347 36.4 Special Provisions.
351 36.5 Building Services.
36.6 Reserved.
36.7 Operating Features.
Chapter 37 Existing Mercantile Occupancies
37.1 General Requirements.
352 37.2 Means of Egress Requirements.
354 37.3 Protection.
355 37.4 Special Provisions.
358 37.5 Building Services.
359 37.6 Reserved.
37.7 Operating Features.
Chapter 38 New Business Occupancies
38.1 General Requirements.
360 38.2 Means of Egress Requirements.
362 38.3 Protection.
363 38.4 Special Provisions.
38.5 Building Services.
38.6 Reserved.
38.7 Operating Features.
Chapter 39 Existing Business Occupancies
39.1 General Requirements.
364 39.2 Means of Egress Requirements.
366 39.3 Protection.
367 39.4 Special Provisions.
368 39.5 Building Services.
39.6 Reserved.
39.7 Operating Features.
Chapter 40 Industrial Occupancies
40.1 General Requirements.
369 40.2 Means of Egress Requirements.
371 40.3 Protection.
372 40.4 Special Provisions.
40.5 Building Services.
373 40.6 Special Provisions for Aircraft Servicing Hangars.
40.7 Operating Features.
Chapter 41 Reserved
Chapter 42 Storage Occupancies
42.1 General Requirements.
42.2 Means of Egress Requirements.
375 42.3 Protection.
376 42.4 Special Provisions.
42.5 Building Services.
42.6 Special Provisions for Aircraft Storage Hangars.
42.7 Special Provisions for Grain Handling, Processing, Milling, or Other Bulk Storage Facilities.
377 42.8 Special Provisions for Parking Structures.
379 42.9 Operating Features.
380 Chapter 43 Building Rehabilitation
43.1 General.
43.2 Special Definitions.
381 43.3 Repairs.
43.4 Renovations.
43.5 Modifications.
382 43.6 Reconstruction.
383 43.7 Change of Use or Occupancy Classification.
384 43.8 Additions.
43.9 Reserved.
43.10 Historic Buildings.
386 Annex A Explanatory Material
502 Annex B Supplemental Evacuation Equipment
505 Annex C NFPA Documents on Hazardous Materials
507 Annex D Informational References
NFPA 101 2018
$80.71