Meet the modern challenges of helping to protect people from fire and related hazards with the new edition of NFPA 101®, Life Safety Code®. Fires remain among the most prevalent dangers in our society, claiming nearly 4,000 lives each year in the United States alone. Often, the difference between life and death is something as simple as the use of smoke alarms and practicing basic fire prevention habits. NFPA 101, Life Safety Code, is the most widely referenced source for occupant safety strategies based on construction, protection, and occupancy features in all stages of a building life cycle. Relevant to life safety in both new and existing structures, NFPA 101 covers everything from means of egress and features of fire protection to hazardous materials emergencies, injuries from falls, and emergency communications. The code applies to nearly all types of occupancies and structures, including residential, business, mercantile, health care, daycare, and assembly occupancies. The 2021 edition is your resource for getting up to date and compliant with critical life safety requirements. NFPA 101 offers a flexible approach that adapts to new technologies, materials, and construction practices, innovations in design, and nontraditional uses of buildings. The 2021 edition provides the most current safety criteria with key revisions, including: Provisions making sprinklers mandatory in new daycare occupancies with more than 12 clients Enhanced sprinkler requirements for existing high-rise buildings containing ambulatory health care, business, industrial, or apartment building occupancies Amended construction limits for existing nursing homes Clarification that non-required fire doors are not subject to the requirements of NFPA 80, including annual inspection New provisions for temporary barriers to separate areas under construction in health care and ambulatory health care occupancies Updated criteria for special amusement buildings Requirements making sprinklers mandatory for new bars and restaurants with an occupant load of 50 or more Minimum requirement added for fire department two-way communication signal strength in all new buildings New carbon monoxide detection requirement for existing hotels and dormitories Introduction of a requirement for low-frequency fire alarm notification signals in new hotel, dormitory, and apartment building sleeping rooms per NFPA 72® Expanded provisions covering burglar bars/grates on means of escape windows in residential occupancies Get the knowledge you need to help eliminate risks in the built environment efficiently and effectively.

PDF Catalog

PDF Pages PDF Title
2 Important Notices and Disclaimers
3 Additional Important Notices and Disclaimers
27 Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Application.
1.4 Equivalency.
28 1.5 Units and Formulas.
1.6 Enforcement.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
29 2.3 Other Publications.
31 2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
44 Chapter 4 General
4.1 Goals.
4.2 Objectives.
4.3 Assumptions.
4.4 Life Safety Compliance Options.
45 4.5 Fundamental Requirements.
4.6 General Requirements.
48 4.7 Fire Drills.
4.8 Emergency Action Plan.
49 Chapter 5 Performance-Based Option
5.1 General Requirements.
5.2 Performance Criteria.
5.3 Retained Prescriptive Requirements.
5.4 Design Specifications and Other Conditions.
50 5.5 Design Fire Scenarios.
51 5.6 Evaluation of Proposed Designs.
5.7 Safety Factors.
5.8 Documentation Requirements.
52 Chapter 6 Classification of Occupancy and Hazard of Contents
6.1 Classification of Occupancy.
56 6.2 Hazard of Contents.
Chapter 7 Means of Egress
7.1 General.
58 7.2 Means of Egress Components.
85 7.3 Capacity of Means of Egress.
88 7.4 Number of Means of Egress.
7.5 Arrangement of Means of Egress.
90 7.6 Measurement of Travel Distance to Exits.
7.7 Discharge from Exits.
91 7.8 Illumination of Means of Egress.
92 7.9 Emergency Lighting.
93 7.10 Marking of Means of Egress.
95 7.11 Special Provisions for Occupancies with High -Hazard Contents.
7.12 Special Provisions for Hazardous Materials.
7.13 Mechanical Equipment Rooms, Boiler Rooms, and Furnace Rooms.
96 7.14 Normally Unoccupied Building Service Equipment Support Areas.
97 7.15 Occupant Evacuation Elevators.
99 7.16 Emergency Stair Travel Devices.
Chapter 8 Features of Fire Protection
8.1 General.
8.2 Construction and Compartmentation.
100 8.3 Fire Barriers.
105 8.4 Smoke Partitions.
8.5 Smoke Barriers.
107 8.6 Vertical Openings.
110 8.7 Special Hazard Protection.
111 8.8 Inspection and Testing of Door Assemblies.
Chapter 9 Building Service, Fire Protection, and Life Safety Equipment
9.1 Utilities.
112 9.2 Heating, Ventilating, and Air-Conditioning.
9.3 Smoke Control.
9.4 Elevators, Escalators, and Conveyors.
113 9.5 Waste Chutes, Incinerators, and Laundry Chutes.
9.6 Fire Detection, Alarm, and Communications Systems.
116 9.7 Automatic Sprinklers.
117 9.8 Other Automatic Extinguishing Equipment.
9.9 Portable Fire Extinguishers.
9.10 Standpipe Systems.
9.11 Fire Protection System Operating Features.
9.12 Carbon Monoxide (CO) Detection and Warning Equipment.
9.13 Special Inspections and Tests.
118 9.14 Risk Analysis for Mass Notification Systems.
9.15 Two-Way Radio Communication Enhancement Systems.
Chapter 10 Interior Finish, Contents, and Furnishings
10.1 General.
10.2 Interior Finish.
122 10.3 Contents and Furnishings.
123 10.4 Outdoor Furniture.
10.5 Combustible Artificial Decorative Vegetation on Roofs and Near Buildings.
Chapter 11 Special Structures and High-Rise Buildings
11.1 General Requirements.
11.2 Open Structures.
124 11.3 Towers.
127 11.4 Water-Surrounded Structures.
11.5 Piers.
128 11.6 Vehicles and Vessels.
11.7 Underground Structures and Limited -Access Structures.
129 11.8 High-Rise Buildings.
131 11.9 Permanent Membrane Structures.
132 11.10 Temporary Membrane Structures.
133 11.11 Tents.
134 11.12 Animal Housing Facilities.
Chapter 12 New Assembly Occupancies
12.1 General Requirements.
135 12.2 Means of Egress Requirements.
143 12.3 Protection.
145 12.4 Special Provisions.
155 12.5 Building Services.
156 12.6 Reserved.
12.7 Operating Features.
160 Chapter 13 Existing Assembly Occupancies
13.1 General Requirements.
162 13.2 Means of Egress Requirements.
169 13.3 Protection.
171 13.4 Special Provisions.
180 13.5 Building Services.
13.6 Reserved.
13.7 Operating Features.
184 Chapter 14 New Educational Occupancies
14.1 General Requirements.
185 14.2 Means of Egress Requirements.
187 14.3 Protection.
190 14.4 Special Provisions.
14.5 Building Services.
14.6 Reserved.
14.7 Operating Features.
191 Chapter 15 Existing Educational Occupancies
15.1 General Requirements.
192 15.2 Means of Egress Requirements.
194 15.3 Protection.
196 15.4 Special Provisions.
197 15.5 Building Services.
15.6 Reserved.
15.7 Operating Features.
198 Chapter 16 New Day-Care Occupancies
16.1 General Requirements.
199 16.2 Means of Egress Requirements.
201 16.3 Protection.
202 16.4 Special Provisions.
203 16.5 Building Services.
16.6 Day-Care Homes.
205 16.7 Operating Features.
206 Chapter 17 Existing Day-Care Occupancies
17.1 General Requirements.
207 17.2 Means of Egress Requirements.
210 17.3 Protection.
211 17.4 Special Provisions.
17.5 Building Services.
17.6 Day-Care Homes.
213 17.7 Operating Features.
214 Chapter 18 New Health Care Occupancies
18.1 General Requirements.
217 18.2 Means of Egress Requirements.
223 18.3 Protection.
228 18.4 Special Provisions.
230 18.5 Building Services.
231 18.6 Reserved.
18.7 Operating Features.
234 Chapter 19 Existing Health Care Occupancies
19.1 General Requirements.
237 19.2 Means of Egress Requirements.
242 19.3 Protection.
249 19.4 Special Provisions.
19.5 Building Services.
250 19.6 Reserved.
19.7 Operating Features.
253 Chapter 20 New Ambulatory Health Care Occupancies
20.1 General Requirements.
254 20.2 Means of Egress Requirements.
256 20.3 Protection.
258 20.4 Special Provisions.
259 20.5 Building Services.
20.6 Reserved.
20.7 Operating Features.
261 Chapter 21 Existing Ambulatory Health Care Occupancies
21.1 General Requirements.
263 21.2 Means of Egress Requirements.
264 21.3 Protection.
266 21.4 Special Provisions.
267 21.5 Building Services.
21.6 Reserved.
21.7 Operating Features.
269 Chapter 22 New Detention and Correctional Occupancies
22.1 General Requirements.
271 22.2 Means of Egress Requirements.
273 22.3 Protection.
276 22.4 Special Provisions.
280 22.5 Building Services.
22.6 Reserved.
22.7 Operating Features.
281 Chapter 23 Existing Detention and Correctional Occupancies
23.1 General Requirements.
284 23.2 Means of Egress Requirements.
286 23.3 Protection.
289 23.4 Special Provisions.
291 23.5 Building Services.
23.6 Reserved.
23.7 Operating Features.
292 Chapter 24 One- and Two-Family Dwellings
24.1 General Requirements.
293 24.2 Means of Escape Requirements.
295 24.3 Protection.
296 24.4 Reserved.
24.5 Building Services.
Chapter 25 Reserved
Chapter 26 Lodging or Rooming Houses
26.1 General Requirements.
297 26.2 Means of Escape Requirements.
26.3 Protection.
299 26.4 ReservedSpecial Structures.
26.5 Building Services.
26.6 Reserved.
26.7 Operating Features.
Chapter 27 Reserved
Chapter 28 New Hotels and Dormitories
28.1 General Requirements.
300 28.2 Means of Egress Requirements.
302 28.3 Protection.
304 28.4 Special Provisions.
28.5 Building Services.
305 28.6 Reserved.
28.7 Operating Features.
Chapter 29 Existing Hotels and Dormitories
29.1 General Requirements.
306 29.2 Means of Egress Requirements.
308 29.3 Protection.
310 29.4 Special Provisions.
29.5 Building Services.
311 29.6 Reserved.
29.7 Operating Features.
Chapter 30 New Apartment Buildings
30.1 General Requirements.
312 30.2 Means of Egress Requirements.
314 30.3 Protection.
316 30.4 Special Provisions.
30.5 Building Services.
317 30.6 Reserved.
30.7 Operating Features.
Chapter 31 Existing Apartment Buildings
31.1 General Requirements.
318 31.2 Means of Egress Requirements.
320 31.3 Protection.
322 31.4 Special Provisions.
31.5 Building Services.
323 31.6 Reserved.
31.7 Operating Features.
Chapter 32 New Residential Board and Care Occupancies
32.1 General Requirements.
324 32.2 Small Facilities.
328 32.3 Large Facilities.
334 32.4 Suitability of an Apartment Building to House a Board and Care Occupancy.
32.5 Reserved.
32.6 Reserved.
32.7 Operating Features.
335 Chapter 33 Existing Residential Board and Care Occupancies
33.1 General Requirements.
336 33.2 Small Facilities.
342 33.3 Large Facilities.
348 33.4 Suitability of an Apartment Building to House a Board and Care Occupancy.
349 33.5 Reserved.
33.6 Reserved.
33.7 Operating Features.
350 Chapter 34 Reserved
Chapter 35 Reserved
Chapter 36 New Mercantile Occupancies
36.1 General Requirements.
351 36.2 Means of Egress Requirements.
353 36.3 Protection.
354 36.4 Special Provisions.
358 36.5 Building Services.
36.6 Reserved.
36.7 Operating Features.
Chapter 37 Existing Mercantile Occupancies
37.1 General Requirements.
359 37.2 Means of Egress Requirements.
361 37.3 Protection.
362 37.4 Special Provisions.
365 37.5 Building Services.
366 37.6 Reserved.
37.7 Operating Features.
Chapter 38 New Business Occupancies
38.1 General Requirements.
367 38.2 Means of Egress Requirements.
369 38.3 Protection.
370 38.4 Special Provisions.
38.5 Building Services.
38.6 Reserved.
38.7 Operating Features.
Chapter 39 Existing Business Occupancies
39.1 General Requirements.
371 39.2 Means of Egress Requirements.
373 39.3 Protection.
374 39.4 Special Provisions.
39.5 Building Services.
39.6 Reserved.
375 39.7 Operating Features.
Chapter 40 Industrial Occupancies
40.1 General Requirements.
376 40.2 Means of Egress Requirements.
378 40.3 Protection.
379 40.4 Special Provisions.
40.5 Building Services.
380 40.6 Special Provisions for Aircraft Servicing Hangars.
40.7 Operating Features.
Chapter 41 Reserved
Chapter 42 Storage Occupancies
42.1 General Requirements.
42.2 Means of Egress Requirements.
382 42.3 Protection.
383 42.4 Special Provisions.
42.5 Building Services.
42.6 Special Provisions for Aircraft Storage Hangars.
42.7 Special Provisions for Grain Handling, Processing, Milling, or Other Bulk Storage Facilities.
384 42.8 Special Provisions for Parking Structures.
387 42.9 Operating Features.
Chapter 43 Building Rehabilitation
43.1 General.
43.2 Special Definitions.
388 43.3 Repairs.
43.4 Renovations.
43.5 Modifications.
389 43.6 Reconstruction.
390 43.7 Change of Use or Occupancy Classification.
391 43.8 Additions.
43.9 Reserved.
43.10 Historic Buildings.
393 Annex A Explanatory Material
517 Annex B Supplemental Evacuation Equipment
520 Annex C NFPA Documents on Hazardous Materials
522 Annex D Informational References
NFPA 101 2021
$86.67