NFPA 105 2022
$80.71
NFPA 105: Standard for Smoke Door Assemblies and Other Opening Protectives
Published By | Publication Date | Number of Pages |
NFPA | 2022 |
Consult the 2022 edition of NFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives, for the most up-to-date requirements for smoke door assembly and opening protective performance. NFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives, offers designers, engineers, installers, and contractors the most comprehensive requirements for the performance of required smoke door assemblies, smoke dampers, and other opening protectives that are intended to limit the spread of smoke. Recent changes in the 2022 edition of NFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives, include the following: A new section clarifying that the standard applies to inspection, testing, and maintenance of all types of smoke-rated opening protectives New definitions for annual frequency and corridor damper Revisions in Section 9.1 for testing and identification of smoke-protective curtain assemblies for hoistways Updated referenced publications and extracts Revisions to the 2022 edition of NFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives, also include a number of changes in Chapter 7. The revisions for dampers in Chapter 7 include the following: Addition of requirements for corridor dampers Specification of listing requirements Addition of inspection and testing documentation requirements Clarification that smoke damper inspection and testing must be completed by a qualified person Provisions pertaining to the installation of remote position indication functionality on existing dampers Smoke can kill people and damage buildings during a fire; this standard can help installers, engineers, facility managers, and authorities having jurisdiction (AHJs) verify that smoke doors, smoke dampers, and other opening protectives are properly maintained and ready to do their job. Order your copy of the 2022 edition of NFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives, today to help protect people and property from deadly smoke hazards.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Important Notices and Disclaimers |
3 | Additional Important Notices and Disclaimers |
9 | Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Retroactivity. 1.5 Equivalency. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. |
10 | 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. Chapter 4 General Requirements 4.1 General. 4.2 Test Specimen. |
11 | 4.3 Air Leakage Test. 4.4 Labeling. 4.5 Installation. Chapter 5 Inspection, Testing, and Maintenance of Smoke Door Assemblies 5.1 General. 5.2 Inspections and Testing. |
13 | 5.3 Performance-Based Option. 5.4 Maintenance. 5.5 Prevention of Door Blockage. 5.6 Maintenance of Closing Mechanisms. |
14 | Chapter 6 Swinging Doors 6.1 General. 6.2 Swinging Doors with Fire Protection Ratings. 6.3 Swinging Doors Without Fire Protection Ratings. |
15 | 6.4 Vision Panels in Doors. 6.5 Glazing in Sidelight and Transom Light Frames. 6.6 Side Panel and Transom Panel Frames. 6.7 Gasketing and Astragals. Chapter 7 Installation, Testing, and Maintenance of Smoke Dampers 7.1 General. |
16 | 7.2 Definitions. (Reserved) 7.3 Installation. 7.4 Operational Test. 7.5 AcceptanceInspection and Testing. |
17 | 7.6 Maintenance. 7.7 Field Modifications. Chapter 8 Smoke-Protective Curtain Assemblies 8.1 General. 8.2 Mounting of Smoke-Protective Curtain Assemblies. 8.3 Assembly Components. 8.4 Power Operators. 8.5 Installation. |
18 | 8.6 Inspection, Testing, and Maintenance and Testing. 8.7 Maintenance. Chapter 9 Smoke-Protective Curtain Assemblies for Hoistways 9.1 General. |
19 | 9.2 Mounting of Smoke-Protective Curtain Assemblies for Hoistways. 9.3 Assembly Components. 9.4 Power Operators. 9.5 Installation. 9.6 Inspection, Testing, and Maintenance and Testing. |
20 | 9.7 Maintenance. Annex A Explanatory Material |
26 | Annex B Performance-Based Option for the Inspection, Testing, and Maintenance of Smoke Door Assemblies |
27 | Annex C Informational References |