NFPA 12A:2009 Edition
$80.71
Standard on Halon 1301 Fire Extinguishing Systems
Published By | Publication Date | Number of Pages |
NFPA | 2009 | 68 |
Get the latest on halon systems in the 2009 NFPA 12A: Standard on Halon 1301 Fire Extinguishing Systems.
The 2009 NFPA 12A provides the most advanced rules for designing, installing, testing, inspecting, approving, listing, operating, maintaining, decommissioning, and removing halogenated agent systems, so that such equipment will function as intended throughout its life.
Topics addressed include: components; systems design; and inspection, maintenance, testing, and training. Numerous appendices provide valuable information on enclosure integrity procedure, hazards to personnel, storage containers, piping, system flow calculations, and more.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Important Notices and Disclaimers Important Notices and Disclaimers |
3 | Additional Notices and disclaimers Additional Notices and disclaimers |
4 | 2.1 General 2.1 General 2.2 NFPA Publications 2.2 NFPA Publications |
7 | Chapter 1 Administration Chapter 1 Administration 1.1 Scope 1.1 Scope 1.2 Purpose 1.2 Purpose 1.3 Units 1.3 Units 1.4 Use and Limitations 1.4 Use and Limitations |
8 | 1.5 Safety 1.5 Safety Chapter 2 Referenced Publications Chapter 2 Referenced Publications 2.3 Other Publications 2.3 Other Publications 2.4 References for Extracts in Mandatory Sections 2.4 References for Extracts in Mandatory Sections Chapter 3 Definitions Chapter 3 Definitions 3.1 General 3.1 General 3.2 NFPA Official Definitions 3.2 NFPA Official Definitions |
9 | 3.3 General Definitions 3.3 General Definitions Chapter 4 Components Chapter 4 Components 4.1 Halon 1301 Supply 4.1 Halon 1301 Supply 4.2 Distribution 4.2 Distribution |
10 | 4.3 Detection, Actuation, Alarm, and Control Systems 4.3 Detection, Actuation, Alarm, and Control Systems |
11 | Chapter 5 System Design Chapter 5 System Design 5.1 Specifications, Plans, and Approvals 5.1 Specifications, Plans, and Approvals |
12 | 5.2 System Flow Calculations 5.2 System Flow Calculations 5.3 Enclosure 5.3 Enclosure 5.4 Design Concentration Requirements 5.4 Design Concentration Requirements |
13 | 5.5 Determination of Halon 1301 Quantity for Total Flooding Systems 5.5 Determination of Halon 1301 Quantity for Total Flooding Systems 5.6 Altitude Adjustments 5.6 Altitude Adjustments 5.7 Distribution System 5.7 Distribution System 5.8 Nozzle Choice and Location 5.8 Nozzle Choice and Location Chapter 6 Inspection, Maintenance, Testing, and Training Chapter 6 Inspection, Maintenance, Testing, and Training 6.1 Inspection and Tests 6.1 Inspection and Tests |
14 | 6.2 Container Test 6.2 Container Test 6.3 Hose Test 6.3 Hose Test 6.4 Enclosure Inspection 6.4 Enclosure Inspection 6.5 Maintenance 6.5 Maintenance 6.6 Training 6.6 Training 6.7 Approval of Installations 6.7 Approval of Installations |
16 | Annex A Explanatory Material Annex A Explanatory Material |
21 | Annex B Enclosure Integrity Procedure Annex B Enclosure Integrity Procedure |
30 | Annex C Halogenated Extinguishing Agents Annex C Halogenated Extinguishing Agents |
32 | Annex D Hazards to Personnel Annex D Hazards to Personnel |
34 | Annex E Storage Containers Annex E Storage Containers |
36 | Annex F Piping Annex F Piping |
37 | Annex G System Flow Calculations Annex G System Flow Calculations |
39 | Annex H Nozzles Annex H Nozzles |
50 | Annex I Fire Extinguishment Annex I Fire Extinguishment |
51 | Annex J Surface Fires Annex J Surface Fires |
52 | Annex K Total Flooding Quantity Annex K Total Flooding Quantity |
55 | Annex L Approval of Installations Annex L Approval of Installations |
57 | Annex M Informational References Annex M Informational References |
59 | Index Index |
62 | Formal Interpretations Formal Interpretations |