Shopping Cart

No products in the cart.

NFPA 12A:2009 Edition

$80.71

Standard on Halon 1301 Fire Extinguishing Systems

Published By Publication Date Number of Pages
NFPA 2009 68
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Get the latest on halon systems in the 2009 NFPA 12A: Standard on Halon 1301 Fire Extinguishing Systems.

The 2009 NFPA 12A provides the most advanced rules for designing, installing, testing, inspecting, approving, listing, operating, maintaining, decommissioning, and removing halogenated agent systems, so that such equipment will function as intended throughout its life.

Topics addressed include: components; systems design; and inspection, maintenance, testing, and training. Numerous appendices provide valuable information on enclosure integrity procedure, hazards to personnel, storage containers, piping, system flow calculations, and more.

PDF Catalog

PDF Pages PDF Title
2 Important Notices and Disclaimers
Important Notices and Disclaimers
3 Additional Notices and disclaimers
Additional Notices and disclaimers
4 2.1 General
2.1 General
2.2 NFPA Publications
2.2 NFPA Publications
7 Chapter 1 Administration
Chapter 1 Administration
1.1 Scope
1.1 Scope
1.2 Purpose
1.2 Purpose
1.3 Units
1.3 Units
1.4 Use and Limitations
1.4 Use and Limitations
8 1.5 Safety
1.5 Safety
Chapter 2 Referenced Publications
Chapter 2 Referenced Publications
2.3 Other Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
Chapter 3 Definitions
3.1 General
3.1 General
3.2 NFPA Official Definitions
3.2 NFPA Official Definitions
9 3.3 General Definitions
3.3 General Definitions
Chapter 4 Components
Chapter 4 Components
4.1 Halon 1301 Supply
4.1 Halon 1301 Supply
4.2 Distribution
4.2 Distribution
10 4.3 Detection, Actuation, Alarm, and Control Systems
4.3 Detection, Actuation, Alarm, and Control Systems
11 Chapter 5 System Design
Chapter 5 System Design
5.1 Specifications, Plans, and Approvals
5.1 Specifications, Plans, and Approvals
12 5.2 System Flow Calculations
5.2 System Flow Calculations
5.3 Enclosure
5.3 Enclosure
5.4 Design Concentration Requirements
5.4 Design Concentration Requirements
13 5.5 Determination of Halon 1301 Quantity for Total Flooding Systems
5.5 Determination of Halon 1301 Quantity for Total Flooding Systems
5.6 Altitude Adjustments
5.6 Altitude Adjustments
5.7 Distribution System
5.7 Distribution System
5.8 Nozzle Choice and Location
5.8 Nozzle Choice and Location
Chapter 6 Inspection, Maintenance, Testing, and Training
Chapter 6 Inspection, Maintenance, Testing, and Training
6.1 Inspection and Tests
6.1 Inspection and Tests
14 6.2 Container Test
6.2 Container Test
6.3 Hose Test
6.3 Hose Test
6.4 Enclosure Inspection
6.4 Enclosure Inspection
6.5 Maintenance
6.5 Maintenance
6.6 Training
6.6 Training
6.7 Approval of Installations
6.7 Approval of Installations
16 Annex A Explanatory Material
Annex A Explanatory Material
21 Annex B Enclosure Integrity Procedure
Annex B Enclosure Integrity Procedure
30 Annex C Halogenated Extinguishing Agents
Annex C Halogenated Extinguishing Agents
32 Annex D Hazards to Personnel
Annex D Hazards to Personnel
34 Annex E Storage Containers
Annex E Storage Containers
36 Annex F Piping
Annex F Piping
37 Annex G System Flow Calculations
Annex G System Flow Calculations
39 Annex H Nozzles
Annex H Nozzles
50 Annex I Fire Extinguishment
Annex I Fire Extinguishment
51 Annex J Surface Fires
Annex J Surface Fires
52 Annex K Total Flooding Quantity
Annex K Total Flooding Quantity
55 Annex L Approval of Installations
Annex L Approval of Installations
57 Annex M Informational References
Annex M Informational References
59 Index
Index
62 Formal Interpretations
Formal Interpretations
NFPA 12A
$80.71