Shopping Cart

No products in the cart.

NFPA 18: Standard on Wetting Agents:2021 Edition

$61.75

NFPA 18: Standard on Wetting Agents

Published By Publication Date Number of Pages
NFPA 2021 23
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 Copyright
Edition
Origin and Development
Committee Lists for NFPA-18-2021
2 Chapter 1 : Administration
1.1 * Scope.
1.2 Purpose.
1.3 Application.
1.4 Retroactivity.
3 1.5 Equivalency.
1.6 Units and Formulas.
1.6.1
1.6.2
Chapter 2 : Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications. 2.3.1 ASTM Publications.
2.3.2 EPA Publications.
2.3.3 ISO Publications.
4 2.3.4 NACE Publications.
2.3.5 UL Publications.
2.3.6 U.S. Government Publications.
2.3.7 Other Publications.
2.4 References for Extracts in Mandatory Sections.
Chapter 3 : Definitions
3.1 General.
3.2 NFPA Official Definitions. 3.2.1 * Approved.
3.2.2 * Authority Having Jurisdiction (AHJ).
3.2.3 Labeled.
3.2.4 * Listed.
3.2.5 Shall.
3.2.6 Should.
3.2.7 Standard.
3.3 General Definitions.
5 3.3.1 Additive.
3.3.2 Class A Fires.
3.3.3 Class B Fires.
3.3.4 Class C Fires.
3.3.5 Class D Fires.
3.3.6 Combustible Liquid.
3.3.7 Flammable Liquid.
3.3.8 Wetting Agent.
3.3.9 * Wetting Agent Solution.
Chapter 4 : Uses and Limitations
4.1 General. 4.1.1
4.1.1.1
4.1.1.2
4.1.1.3
4.1.1.4
4.2 Limitations. 4.2.1 * General.
4.2.2 Water-Reactive Chemicals.
4.2.3 Class B Fires. 4.2.3.1
4.2.3.2 *
4.2.4 * Class C Fires.
4.2.5 * Class D Fires.
6 4.3 Compatibility of Wetting Agent Concentrate(s) and Solution(s). 4.3.1
4.3.2
4.3.3
4.3.4
4.4 Concentrations.
4.5 Health, Safety, and Environmental Considerations. 4.5.1
4.5.1.1
4.5.1.2
4.5.1.2.1
4.5.1.2.2
4.5.1.3
Chapter 5 : Requirements and Test Methods for Wetting Agent Concentrates and Wetting Agent Solutions
5.1 General. 5.1.1
7 5.1.2
5.1.3
5.2 Wetting Agent Concentrates and Solutions. 5.2.1 Concentrates Pour Point.
5.2.2 Wetting Agent Concentrate Miscibility. 5.2.2.1
5.2.2.2
8 5.2.3 * Wetting Agent Concentrate Separation. 5.2.3.1
5.2.3.2
5.2.4 Impact of Low Temperature of Wetting Agent Concentrate on Surface Tension. 5.2.4.1 *
5.2.4.2
5.2.4.3
5.2.5 * Wetting Agent Concentrate pH.
5.2.6 Wetting Agent Concentrate Viscosity.
5.2.7 Alternate Viscosity Test Methods. 5.2.7.1 *
5.2.7.2
5.2.8 Wetting Agent Concentrate and Solution Toxicity. 5.2.8.1 * Mammalian Toxicity. 5.2.8.1.1
5.2.8.1.2
5.2.8.2 Wetting Agent Concentrate Aquatic Toxicity.
5.2.8.3 * Wetting Agent Concentrate Biodegradability.
5.2.8.3.1
9 5.2.8.3.2
5.2.8.3.3
5.2.8.3.4
5.2.9 * Wetting Agent Concentrate Corrosion.
5.2.9.1 Results.
5.2.9.2 * Samples.
5.2.9.2.1
5.2.9.3 Marking and Measurement.
5.2.9.4 Cleaning and Drying.
5.2.9.4.1
5.2.9.4.2 Procedure for Cleaning. 5.2.9.4.2.1
10 5.2.9.4.2.2
5.2.9.4.3
5.2.9.5 Test Setup.
5.2.9.5.1
5.2.9.5.2
5.2.9.5.3
5.2.9.5.4
5.2.9.6 Test Duration and Completion.
5.2.9.6.1
5.2.9.6.2
5.2.9.6.3
5.2.9.6.4
5.2.9.6.5
5.2.9.7 Corrosion Rate. 5.2.9.7.1 *
11 5.2.9.7.2
5.3 Wetting Agent Solutions. 5.3.1 Solution Surface Tension.
5.3.1.1
5.3.2 Solution Separation. 5.3.2.1
5.3.2.2
5.3.3 * Wetting Agent Solution Corrosion. 5.3.3.1
5.3.3.2
Chapter 6 : Class A Fire Extinguishment Tests
6.1 General.
6.2 Wood Crib Fire Test. 6.2.1
6.2.2
6.2.3
6.3 Deep-Seated Fire Test. 6.3.1
6.3.2
6.3.3
6.4 Wood Fiberboard Penetration.
12 6.4.1
6.4.2
6.4.3
Chapter 7 : Class B Fire Extinguishment Tests
7.1 * General.
7.2 Listing.
7.3 Test Method.
7.4 Performance Requirement.
Chapter 8 : Wetting Agent Supply
8.1 System Requirements. 8.1.1 * Equipment.
8.2 Fire Department Wetting Agent Supply Requirements. 8.2.1 Tanks.
8.2.2 * Separate Supplies.
13 8.3 * Fixed Systems.
Chapter 9 : Packaging and Labeling
9.1 Packaging. 9.1.1 * Regulations.
9.1.2 Containers.
9.2 Storage. 9.2.1
9.2.2
9.3 Labeling.
Chapter 10 : Inspection, Testing, and Maintenance of Fixed Systems
10.1 * Fixed Extinguishing Systems.
10.2 Inspection of Wetting Agent Concentrate.
Annex A : Explanatory Material
16 Annex B : Informational References
NFPA 18: Standard on Wetting Agents
$61.75