NFPA 24 13:2013 Edition
$80.71
NFPA 24: Standard for the Installation of Private Fire Service Mains and Their Appurtenances
Published By | Publication Date | Number of Pages |
NFPA | 2013 | 58 |
Make sure water supplies are available when needed with NFPA 24. An essential Standard for effective water-based fire protection, NFPA 24: Installation of Private Fire Service Mains and Their Appurtenances presents comprehensive requirements governing private fire service mains and private fire hydrants. Reference the 2013 NFPA 24 for the latest information on location and identification of department connections, protection of fire service mains, and valves controlling water supplies. NFPA 24’s criteria also addresses underground fire service mains and related equipment, yard piping that feeds automatic sprinkler systems, yard hydrants, standpipes, and other water-based systems. Updated definitions make this edition essential.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Important Notices and Disclaimers |
3 | Additional Notices and Discalimers |
4 | 2.1 General 2.2 NFPA Publications |
8 | Chapter 1 Administration 1.1 Scope 1.2 Purpose 1.3 Retroactivity 1.4 Equivalency 1.5 Units |
9 | Chapter 2 Referenced Publications 2.3 Other Publications |
10 | 2.4 References for Extracts in Mandatory Sections Chapter 3 Definitions 3.1 General 3.2 NFPA Official Definitions 3.3 General Definitions |
11 | 3.4 Hydrant Definitions Chapter 4 General Requirements 4.1 Plans 4.2 Installation Work Chapter 5 Water Supplies 5.1 Connection to Waterworks Systems |
12 | 5.2 Size of Fire Mains 5.3 Pressure-Regulating Devices and Meters 5.4 Connection from Waterworks Systems 5.5 Connections to Public Water Systems 5.6 Pumps 5.7 Tanks 5.8 Penstocks, Flumes, Rivers, Lakes, or Reservoirs 5.9 Fire Department Connections Chapter 6 Valves 6.1 Types of Valves |
13 | 6.2 Valves Controlling Water Supplies 6.3 Post Indicator Valves 6.4 Valves in Pits |
14 | 6.5 Backflow Prevention Assemblies 6.6 Sectional Valves 6.7 Identifying and Securing Valves 6.8 Check Valves Chapter 7 Hydrants 7.1 General 7.2 Number and Location 7.3 Installation |
15 | Chapter 8 Hose Houses and Equipment 8.1 General 8.2 Location 8.3 Construction 8.4 Size and Arrangement 8.5 Marking 8.6 General Equipment 8.7 Domestic Service Use Prohibited Chapter 9 Master Streams 9.1 Master Streams 9.2 Application and Special Considerations Chapter 10 Underground Piping 10.1 Piping Materials |
16 | 10.2 Fittings 10.3 Joining of Pipe and Fittings |
17 | 10.4 Depth of Cover 10.5 Protection Against Freezing 10.6 Protection Against Damage |
18 | 10.7 Requirement for Laying Pipe 10.8 Joint Restraint |
19 | 10.9 Backfilling |
20 | 10.10 Testing and Acceptance |
23 | Chapter 11 Hydraulic Calculations 11.1 Calculations in U.S. Customary Units 11.2 Calculations in SI Units Chapter 12 Aboveground Pipe and Fittings 12.1 General 12.2 Protection of Piping Chapter 13 Sizes of Aboveground and Buried Pipe 13.1 Private Service Mains 13.2 Mains Not Supplying Hydrants |
24 | 13.3 Mains Supplying Fire Protection Systems Chapter 14 System Inspection, Testing, and Maintenance 14.1 General Annex A Explanatory Material |
39 | Annex B Valve Supervision Issues |
40 | Annex C Recommended Practice for Fire Flow Testing |
50 | Annex D Recommended Practice for Marking of Hydrants |
51 | Annex E Informational References |
53 | Index |
55 | Formal Interpretation |