NFPA 262 11:2011 Edition

$80.71

NFPA 262: Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces

Published By Publication Date Number of Pages
NFPA 2011 36
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Work with the latest criteria in the 2011 NFPA 262 for accurate assessments of smoke and fire spread. NFPA 262: Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces presents a test procedure to evaluate the potential for fire spread along cables and wires housed in a plenum or other environmental space. The methodology measures both flame travel distance and optical density of smoke. Among the changes in the 2011 edition:     * Revisions to removable top cover protection     * Revisions to create consistency with ASTM E 84     * Added new methods to determine average airflow velocity     * Moved Reference Cable Test into an Annex Invest in fire safety by following the up-to-date testing guidelines in the 2011 NFPA 262.

PDF Catalog

PDF Pages PDF Title
2 Important Notices and Disclaimers
3 Additional Notices and Disclaimers
4 2.1 General
2.2 NFPA Publications
7 Chapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Application
1.4 Units
1.5 Summary of Test Method
8 Chapter 2 Referenced Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
Chapter 4 Test Apparatus
4.1 Fire Test Room
4.2 Fire Test Apparatus
12 4.3 Fire Test Chamber Airflow System
13 4.4 Ladder Cable Tray
14 4.5 Fire Test Chamber Temperature Measurement Instruments
4.6 Data Acquisition Equipment
Chapter 5 Test Specimens
5.1 Specimens
Chapter 6 Maintenance and Calibration of Test Equipment
6.1 Maintenance
6.2 Frequency of Calibration
6.3 Airflow
15 6.4 Smoke Measurement System Calibration Test
6.5 Fuel
6.6 Uncoated Fiber-Reinforced Cement Board Test
16 Chapter 7 Test Specimen Preparation
7.1 Specimen Conditioning
7.2 Determination of Specimen Diameter
7.3 Number of Cable Lengths
7.4 Cable Mounting
17 Chapter 8 Test Procedure
8.1 Procedure
8.2 Exhaust Duct Velocity Measurement Calculations
Chapter 9 Post-Test Cleanup and Inspection
9.1 Debris
9.2 Windows
9.3 Supports
18 9.4 Damaged Boards
9.5 Preparation for Next Test
9.6 Cleanliness of Smoke Measurement System
Chapter 10 Calculations
10.1 Optical Density of Smoke
10.2 Exhaust Duct Velocity Measurement Calculations
Chapter 11 Report
11.1 Data
Chapter 12 Precision and Bias
12.1 Applicability
Annex A Explanatory Material
20 Annex B Smoke and Heat Release Measurements
22 Annex C Smoke Measurement System and Chamber-Brick Configuration: Detail Drawings
30 Annex D Standard Reference Cable Test
31 Annex E Informational References
33 Index
NFPA 262 11
$80.71