Conduct fire flow testing and correctly mark hydrants using NFPA 291, Recommended Practice for Water Flow Testing and Marking of Hydrants, which now includes both metric and imperial measurements. NFPA 291, Recommended Practice for Water Flow Testing and Marking of Hydrants, provides fire protection engineers, contractors, installers, and authorities having jurisdiction (AHJs) with the latest procedures to: Determine the rate of flow available at various locations for fire protection systems and firefighting purposes. Classify hydrants in accordance with their rated capacities. Color-code hydrants to indicate their class. For the 2022 edition of NFPA 291, Recommended Practice for Water Flow Testing and Marking of Hydrants, the purpose and application of the recommended practice have been revised to clarify its applicability. Further changes made for the 2022 edition include the following: Definitions for a variety of hydrant types have been added. The list of equipment needed for field work has been modified and expanded. A description of the pressure gauges to be used and the various types of discharge devices have been added. A new test method for evaluating the available flow through a single hydrant has been added.

PDF Catalog

PDF Pages PDF Title
2 Important Notices and Disclaimers
3 Additional Important Notices and Disclaimers
10 Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Application.
1.4 Units.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications. (Reserved)
2.3 Other Publications.
2.4 References for Extracts in Recommendations Sections. (Reserved)
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
11 3.3 General Definitions.
3.4 Hydrant Definitions.
Chapter 4 Flow Testing
4.1 Water Flow Testing Purposes.
4.2 Rating Pressure.
4.3 Procedure.
4.4 Layout of Test and Procedure to Determine the Available Water Supply in a Water Main.
12 4.5 Layout of Test and Procedure to Evaluate the Available Flow Through a Fire Hydrant.
4.6 Equipment.
4.7 Test Procedure.
13 4.8 Pitot Readings.
4.9 Determination of Discharge.
4.10 Use of Pumper Outlets.
4.11 Determination of Discharge Without a Pitot.
14 4.12 Calculation Results.
4.13 Data Sheet.
4.14 System Corrections.
4.15 Public Hydrant Testing and Flushing.
21 Chapter 5 Marking of Hydrants
5.1 Classification of Hydrants.
5.2 Marking of Hydrants.
Annex A Explanatory Material