NFPA 557 2016
$80.71
NFPA 557: Standard for Determination of Fire Loads for Use in Structural Fire Protection Design
Published By | Publication Date | Number of Pages |
NFPA | 2016 | 36 |
Apply the 2016 NFPA 557 to determine fire load and fire load density for use in calculations of the performance of structures in a fire. Used primarily by designers and engineers, the 2016 NFPA 557: Standard for Determination of Fire Loads for Use in Structural Fire Protection Design provides a methodology for the determination of the fire load and fire load density to be used as the basis for the evaluation and design of the structural fire performance of a building. Developed in response to a request on performance-based design initiatives in the area of fire loads, NFPA 557 covers: Design fundamentals Development of fire loads Occupancy-based fire load density Survey method-based fire load density Documentation, inspection, and maintenance Five Annexes provide additional clarification of requirements. Chapter 4 adds criteria for a material to be considered noncombustible, which is consistent with language in NFPA 101®: Life Safety Code® and NFPA 5000®: Building Construction and Safety Code®. The 2016 edition also includes the latest definitions and up-to-date references essential for designers, engineers, and facility managers.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | Important Notices and Disclaimers |
4 | Additional Notices and Disclaimers |
8 | Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Equivalency. 1.5 Units and Formulas. 1.6 Approved Qualifications. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. |
9 | 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. Chapter 4 Design Fundamentals 4.1 Methodology. |
10 | 4.2 Fire Load. 4.3 Statistical Distribution of Fire Load. 4.4 Frequency of Fire Initiations. 4.5 Effectiveness of Fire Protection Features. 4.6 Combustibility of Materials. Chapter 5 Development of Fire Loads 5.1 Types of Fire Loads. 5.2 Defining the Compartment. 5.3 Distributed Fire Loads. 5.4 Localized Fire Loads. |
11 | 5.5 Frequency of Structurally Significant Fires. 5.6 Approvals and Limitations. 5.7 Application of the Frequencies of Structurally Significant Fires to Occupancies. |
14 | Chapter 6 Occupancy-Based Fire Load Density 6.1 Fire Load Density. 6.2 Design Fire Load Density. |
15 | Chapter 7 Survey Method-Based Fire Load Density 7.1 Fire Load Density 7.2 Fire Load. 7.3 Heats of Combustion. 7.4 Methodology and Limitations. |
16 | Chapter 8 Documentation, Inspection, and Maintenance 8.1 Documented Fire Load. 8.2 Change in Occupancy. 8.3 Repairs. 8.4 Formal Review. Annex A Explanatory Material |
20 | Annex B Summary of Occupancy Based Fuel and Fire Load Survey Data |
21 | Annex C Guidance for Fuel or Fire Load Surveys (Special Facility and Occupancy Based) |
22 | Annex D Analyses of Structurally Significant Fires in Buildings with Selected Characteristics |
29 | Annex E Informational References |