Shopping Cart

No products in the cart.

NFPA 59 2024

$80.71

NFPA 59:Utility LP-Gas Plant Code

Published By Publication Date Number of Pages
NFPA 2024
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Fire, explosions, and other related dangers pose significant risks to utility gas plants with liquefied petroleum gas systems. NFPA 59, Utility LP-Gas Plant Code, works in combination with DOT regulations to provide provisions for constructing and maintaining plants that store and vaporize LP-Gas or LP-Gas

PDF Catalog

PDF Pages PDF Title
2 Blank Page
3 Important Notices and Disclaimers
4 Additional Important Notices and Disclaimers
10 Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Nonapplication of Code.
1.4 Retroactivity.
1.5 Equivalency.
1.6 Enforcement.
11 1.7 Pressure Measurement.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications.
12 2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
14 Chapter 4 General Requirements
4.1 Personnel Training.
4.2 Odorizing Gases.
4.3 Acceptance of Equipment.
4.4 Damage from Vehicles.
4.5 Ignition Source Control.
16 4.6 Lighting.
4.7 Construction and Modification Records.
4.8 Design and Installation.
17 4.9 Atmospheric Corrosion Control.
4.10 External Corrosion Control: Buried or Submerged Components.
4.11 Internal Corrosion Control.
4.12 Interference Currents.
18 Chapter 5 Nonrefrigerated Containers
5.1 Provision for Construction and Original Test of Nonrefrigerated Containers.
5.2 Design Pressure and Classification of Nonrefrigerated Containers.
5.3 ASME Container Markings.
5.4 Location of Nonrefrigerated Containers.
19 5.5 Installation of Nonrefrigerated Storage Containers.
20 5.6 Reinstallation of Nonrefrigerated Containers.
5.7 Filling Densities.
21 5.8 Point of Transfer Spacing.
Chapter 6 Refrigerated Containers
6.1 Scope.
6.2 Refrigerated Containers Designed to Operate Below 7 psi (103 kPa) and Above 5000 bbls (800 m3).
24 6.3 Refrigerated Containers Designed to Operate Above 15 psi (103 kPa).
26 Chapter 7 Piping, Valves, Process Pressure Vessels, and Equipment
7.1 General.
27 7.2 Container Valves and Accessories.
28 7.3 Filler and Discharge Pipes and Manifolds.
7.4 Liquid Level Gauging Device.
7.5 Hose Specifications for Nonrefrigerated LP-Gas.
7.6 Drips, Pits, and Drains.
29 7.7 Pumps and Compressors.
7.8 Pumps and Compressors in Refrigerated LP-Gas Systems.
7.9 Process Pressure Vessels.
7.10 Protection of Container Accessories.
7.11 Transfer Equipment.
30 Chapter 8 Buildings or Structures Housing LP-Gas Distribution Facilities
8.1 Scope.
8.2 Separate Structures or Buildings.
8.3 Attached Structures or Rooms Within Structures.
31 8.4 Rooms Housing Vaporizers or Mixers.
Chapter 9 Vaporizers, Heat Exchangers, and Gas–Air Mixers
9.1 General.
9.2 Buildings or Rooms Housing Vaporizers or Gas–Air Mixers.
9.3 Vaporizers.
9.4 Gas–Air Mixers.
32 9.5 Vaporizer Installation.
33 Chapter 10 Relief Devices
10.1 General.
10.2 Nonrefrigerated Container Relief Devices.
35 10.3 Refrigerated Container Relief Devices.
10.4 Relief Device Sizing for Refrigerated Containers.
10.5 Refrigerated Container Relief Device Sizing for Fire Exposure.
36 10.6 Pressure Relief Valve Discharge Vents.
10.7 Vaporizers.
37 10.8 Hydrostatic Relief Valves.
Chapter 11 Operations
11.1 General.
11.2 Operating Procedures Manuals.
11.3 Handling.
11.4 Operating Records.
38 Chapter 12 Maintenance
12.1 Retroactivity.
12.2 Maintenance Manuals.
12.3 Corrosion Protection.
39 12.4 Maintenance of Emergency Shutoff and Check Valves.
12.5 Maintenance of Foundations and Supports.
12.6 Maintenance of Fire Protection Equipment.
12.7 Leakage Surveys.
12.8 Auxiliary Power Sources.
12.9 Purging Prior to Maintenance.
12.10 Maintenance Records.
40 Chapter 13 Fire Protection, Safety, and Security
13.1 General.
13.2 Gas, Fire, and Leak Detection.
41 13.3 Container Protection.
13.4 Fire Protection Water Systems.
13.5 Fire-Extinguishing and Other Fire Protection Equipment.
13.6 Special Protection.
13.7 Maintenance of Fire Protection Equipment.
13.8 Personnel Safety.
42 13.9 Security.
Annex A Explanatory Material
47 Annex B Method of Calculating Maximum Liquid Volume That Can Be Placed in a Container at Any Liquid Temperature
49 Annex C Method of Calculating Maximum Volume of Liquefied Petroleum Gas That Can Be Placed in a Container for Which Length of Fixed Drip Tube Is Set
50 Annex D Relief Device Sizing
Annex E Sample Ordinance Adopting NFPA 59
51 Annex F Informational References
NFPA 59 2024
$80.71