NFPA 70: National Electrical Code (NEC) Handbook 2014
$27.95
NFPA 70: National Electrical Code (NEC) Handbook
Published By | Publication Date | Number of Pages |
NFPA | 2014 | 1275 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
2 | Copyright |
3 | Dedication |
5 | Table of Contents |
9 | Preface |
10 | Acknowledgments |
11 | About the Editors |
13 | Article 90 Introduction |
20 | Chapter 1 General Article 100 Definitions |
39 | Article 110 Requirements for Electrical Installations |
66 | Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Conductors |
71 | Article 210 Branch Circuits |
101 | Article 215 Feeders |
105 | Article 220 Branch-Circuit, Feeder, and Service Calculations |
123 | Article 225 Outside Branch Circuits and Feeders |
133 | Article 230 Services |
157 | Article 240 Overcurrent Protection |
178 | Article 250 Grounding and Bonding |
240 | Article 280 Surge Arresters, Over 1000 Volts |
241 | Article 285 Surge-Protective Devices (SPDs), 1000 Volts or Less |
245 | Chapter 3 Wiring Methods and Materials Article 300 General Requirements for Wiring Methods and Materials |
267 | Article 310 Conductors for General Wiring |
300 | Article 312 Cabinets, Cutout Boxes, and Meter Socket Enclosures |
306 | Article 314 Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings; and Handhole Enclosures |
321 | Article 320 Armored Cable: Type AC |
323 | Article 322 Flat Cable Assemblies: Type FC |
325 | Article 324 Flat Conductor Cable: Type FCC |
327 | Article 326 Integrated Gas Spacer Cable: Type IGS |
328 | Article 328 Medium Voltage Cable: Type MV |
329 | Article 330 Metal-Clad Cable: Type MC |
332 | Article 332 Mineral-Insulated, Metal-Sheathed Cable: Type MI |
335 | Article 334 Nonmetallic-Sheathed Cable: Types NM, NMC, and NMS |
340 | Article 336 Power and Control Tray Cable: Type TC |
341 | Article 338 Service-Entrance Cable: Types SE and USE |
343 | Article 340 Underground Feeder and Branch-Circuit Cable: Type UF |
344 | Article 342 Intermediate Metal Conduit: Type IMC |
347 | Article 344 Rigid Metal Conduit: Type RMC |
350 | Article 348 Flexible Metal Conduit: Type FMC |
353 | Article 350 Liquidtight Flexible Metal Conduit: Type LFMC |
355 | Article 352 Rigid Polyvinyl Chloride Conduit: Type PVC |
358 | Article 353 High Density Polyethylene Conduit: Type HDPE Conduit |
360 | Article 354 Nonmetallic Underground Conduit with Conductors: Type NUCC |
361 | Article 355 Reinforced Thermosetting Resin Conduit: Type RTRC |
364 | Article 356 Liquidtight Flexible Nonmetallic Conduit: Type LFNC |
366 | Article 358 Electrical Metallic Tubing: Type EMT |
369 | Article 360 Flexible Metallic Tubing: Type FMT |
370 | Article 362 Electrical Nonmetallic Tubing: Type ENT |
375 | Article 366 Auxiliary Gutters |
377 | Article 368 Busways |
381 | Article 370 Cablebus |
383 | Article 372 Cellular Concrete Floor Raceways |
384 | Article 374 Cellular Metal Floor Raceways |
385 | Article 376 Metal Wireways |
387 | Article 378 Nonmetallic Wireways |
389 | Article 380 Multioutlet Assembly Article 382 Nonmetallic Extensions |
392 | Article 384 Strut-Type Channel Raceway |
393 | Article 386 Surface Metal Raceways |
395 | Article 388 Surface Nonmetallic Raceways |
396 | Article 390 Underfloor Raceways |
398 | Article 392 Cable Trays |
407 | Article 393 Low-Voltage Suspended Ceiling Power Distribution Systems |
410 | Article 394 Concealed Knob-and-Tube Wiring |
411 | Article 396 Messenger-Supported Wiring |
412 | Article 398 Open Wiring on Insulators |
414 | Article 399 Outdoor Overhead Conductors over 1000 Volts |
415 | Chapter 4 Equipment for General Use Article 400 Flexible Cords and Cables |
426 | Article 402 Fixture Wires |
430 | Article 404 Switches |
435 | Article 406 Receptacles, Cord Connectors, and Attachment Plugs (Caps) |
443 | Article 408 Switchboards, Switchgear, and Panelboards |
451 | Article 409 Industrial Control Panels |
454 | Article 410 Luminaires, Lampholders, and Lamps |
469 | Article 411 Lighting Systems Operating at 30 Volts or Less and Lighting Equipment Connected to Class-2 Power Sources |
470 | Article 422 Appliances |
477 | Article 424 Fixed Electric Space-Heating Equipment |
486 | Article 426 Fixed Outdoor Electric Deicing and Snow- Melting Equipment |
490 | Article 427 Fixed Electric Heating Equipment for Pipelines and Vessels |
493 | Article 430 Motors, Motor Circuits, and Controllers |
539 | Article 440 Air-Conditioning and Refrigerating Equipment |
547 | Article 445 Generators |
549 | Article 450 Transformers and Transformer Vaults (Including Secondary Ties) |
563 | Article 455 Phase Converters |
565 | Article 460 Capacitors |
568 | Article 470 Resistors and Reactors Article 480 Storage Batteries |
572 | Article 490 Equipment Over 1000 Volts, Nominal |
581 | Chapter 5 Special Occupancies Article 500 Hazardous (Classified) Locations, Classes I, II, and III, Divisions 1 and 2 |
594 | Article 501 Class I Locations |
617 | Article 502 Class II Locations |
624 | Article 503 Class III Locations |
628 | Article 504 Intrinsically Safe Systems |
634 | Article 505 Zone 0, 1, and 2 Locations |
650 | Article 506 Zone 20, 21, and 22 Locations for Combustible Dusts or Ignitible Fibers/Flyings |
658 | Article 510 Hazardous (Classified) Locations – Specific Article 511 Commercial Garages, Repair and Storage |
664 | Article 513 Aircraft Hangars |
667 | Article 514 Motor Fuel Dispensing Facilities |
675 | Article 515 Bulk Storage Plants |
681 | Article 516 Spray Application, Dipping, Coating, and Printing Processes Using Flammable or Combustible Materials |
692 | Article 517 Health Care Facilities |
716 | Article 518 Assembly Occupancies |
720 | Article 520 Theaters, Audience Areas of Motion Picture and Television Studios, Performance Areas, and Similar Locations |
735 | Article 522 Control Systems for Permanent Amusement Attractions |
737 | Article 525 Carnivals, Circuses, Fairs, and Similar Events |
740 | Article 530 Motion Picture and Television Studios and Similar Locations |
744 | Article 540 Motion Picture Projection Rooms |
745 | Article 545 Manufactured Buildings |
747 | Article 547 Agricultural Buildings |
750 | Article 550 Mobile Homes, Manufactured Homes, and Mobile Home Parks |
761 | Article 551 Recreational Vehicles and Recreational Vehicle Parks |
774 | Article 552 Park Trailers |
784 | Article 553 Floating Buildings |
785 | Article 555 Marinas and Boatyards |
790 | Article 590 Temporary Installations |
795 | Chapter 6 Special Equipment Article 600 Electric Signs and Outline Lighting |
802 | Article 604 Manufactured Wiring Systems |
804 | Article 605 Office Furnishings |
806 | Article 610 Cranes and Hoists |
813 | Article 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts |
826 | Article 625 Electric Vehicle Charging System |
834 | Article 626 Electrified Truck Parking Spaces |
839 | Article 630 Electric Welders |
842 | Article 640 Audio Signal Processing, Amplification, and Reproduction Equipment |
849 | Article 645 Information Technology Equipment |
854 | Article 646 Modular Data Centers |
858 | Article 647 Sensitive Electronic Equipment |
860 | Article 650 Pipe Organs Article 660 X-Ray Equipment |
862 | Article 665 Induction and Dielectric Heating Equipment |
866 | Article 668 Electrolytic Cells |
869 | Article 669 Electroplating Article 670 Industrial Machinery |
871 | Article 675 Electrically Driven or Controlled Irrigation Machines |
874 | Article 680 Swimming Pools, Fountains, and Similar Installations |
898 | Article 682 Natural and Artificially Made Bodies of Water |
901 | Article 685 Integrated Electrical Systems Article 690 Solar Photovoltaic (PV) Systems |
923 | Article 692 Fuel Cell Systems |
926 | Article 694 Wind Electric Systems |
932 | Article 695 Fire Pumps |
945 | Chapter 7 Special Conditions Article 700 Emergency Systems |
958 | Article 701 Legally Required Standby Systems |
961 | Article 702 Optional Standby Systems |
964 | Article 705 Interconnected Electric Power Production Sources |
970 | Article 708 Critical Operations Power Systems (COPS) |
976 | Article 720 Circuits and Equipment Operating at Less Than 50 Volts Article 725 Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits |
991 | Article 727 Instrumentation Tray Cable: Type ITC |
992 | Article 728 Fire-Resistive Cable Systems |
993 | Article 750 Energy Management Systems |
994 | Article 760 Fire Alarm Systems |
1008 | Article 770 Optical Fiber Cables and Raceways |
1020 | Chapter 8 Communications Systems Article 800 Communications Circuits |
1038 | Article 810 Radio and Television Equipment |
1043 | Article 820 Community Antenna Television and Radio Distribution Systems |
1054 | Article 830 Network-Powered Broadband Communications Systems |
1068 | Article 840 Premises-Powered Broadband Communications Systems |
1073 | Chapter 9 Tables Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables |
1077 | Table 2 Radius of Conduit and Tubing Bends Table 4 Dimensions and Percent Area of Conduit and Tubing (Areas of Conduit or Tubing for the Combinations of Wires Permitted in Table 1, Chapter 9) |
1082 | Table 5 Dimensions of Insulated Conductors and Fixture Wires |
1086 | Table 5A Compact Copper and Aluminum Building Wire Nominal Dimensions and Areas |
1087 | Table 8 Conductor Properties |
1088 | Table 9 Alternating-Current Resistance and Reactance for 600-Volt Cables, 3-Phase, 60 Hz, 75°C (167°F) – Three Single Conductors in Conduit |
1091 | Table 10 Conductor Stranding |
1092 | Table 11(A) Class 2 and Class 3 Alternating-Current Power Source Limitations Table 11(B) Class 2 and Class 3 Direct-Current Power Source Limitations |
1093 | Table 12(A) PLFA Alternating-Current Power Source Limitations |
1094 | Table 12(B) PLFA Direct-Current Power Source Limitations |
1095 | Annexes Informative Annex A Product Safety Standards |
1101 | Informative Annex B Application Information for Ampacity Calculation |
1115 | Informative Annex C Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size |
1190 | Informative Annex D Examples |
1202 | Informative Annex E Types of Construction |
1205 | Informative Annex F Availability and Reliability for Critical Operations Power Systems; and Development and Implementation of Functional Performance Tests (FPTs) for Critical Operations Power Systems |
1208 | Informative Annex G Supervisory Control and Data Acquisition (SCADA) |
1210 | Informative Annex H Administration and Enforcement |
1217 | Informative Annex I Recommended Tightening Torque Tables from UL Standard 486A-B |
1219 | Informative Annex J ADA Standards for Accessible Design |
1222 | Index |
1273 | TIA14 – 2 |
1274 | TIA14 – 3 |