NFPA 850 2020
$88.83
NFPA 850: Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations
Published By | Publication Date | Number of Pages |
NFPA | 2020 |
Help mitigate risks of fire and explosion in electric generating plants by complying with the latest recommended safety practices. There are special concerns for fire and life safety in plants and facilities that produce or convert the current of electricity. NFPA® 850, Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations, 2020 edition, is an essential resource for assisting in maximizing the safety of personnel, facilities, and the community at large. Criteria apply to new and existing oil, gas, coal, and alternative fuel electrical generating plants, including high voltage direct current converter stations and combustion turbine units used for electric generation. The document provides the framework for creating a Fire Protection Design Basis Document that takes into account potential risks to the particular facility, including flammable liquids, fuels, lubricating oils, dust explosions, and electrical equipment. NFPA 850 also covers the protection and continuity of installations and personnel, systems and components, and plant operations. The NFPA 850, 2020 edition, provides access to cutting-edge criteria for fire prevention and protection of plants generating electricity. Developed to provide a document specifying fire protection measures for all types of non-nuclear electric generating plants, the revised NFPA 850 reflects the most current industry knowledge and best practices. Significant changes to the 2020 edition include: Complete reorganization of the document for accuracy and clarity Grouping of information in a more logical layout to assist users in navigating the document faster and more efficiently Addition of new chapters on flywheel energy systems and compressed air energy storage (CAES) to address technologies being used in the industry Get the support you need to help identify and reduce risks to lives and property in electrical generating plants.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Important Notices and Disclaimers |
3 | Additional Important Notices and Disclaimers |
9 | Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Equivalency. |
10 | 1.5 Units. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. |
11 | 2.3 Other Publications. |
12 | 2.4 References for Extracts in Recommendations Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. |
14 | Chapter 4 Fire Protection Design Process 4.1 General. 4.2 Stakeholders. 4.3 Inputs to the Design Process. 4.4 Fire Protection Design Basis Process. |
15 | 4.5 Fire Protection Design Basis Document (Deliverables). Chapter 5 Fire Risk Control Program 5.1 General. 5.2 Management Policy and Direction. 5.3 Fire Risk Control Program. |
16 | 5.4 Fire Protection Program. |
18 | 5.5 Identification of Fire Hazards of Materials. Chapter 6 General Plant Design 6.1 Plant Arrangement. |
21 | 6.2 Life Safety. 6.3 Building Construction Materials. 6.4 Smoke and Heat Venting, Heating, Ventilating, and Air Conditioning. |
22 | 6.5 Containment and Drainage. |
23 | 6.6 Emergency Lighting. 6.7 Lightning Protection. Chapter 7 General Fire Protection Systems and Equipment 7.1 General. 7.2 Water Supply. |
24 | 7.3 Valve Supervision. 7.4 Supply Mains, Yard Mains, Hydrants, and Building Standpipes. |
25 | 7.5 Portable Fire Extinguishers. 7.6 Fire Suppression Systems and Equipment — General Requirements. |
26 | 7.7 Fire-Signaling Systems. |
27 | 7.8 Commissioning and Maintenance. Chapter 8 Fire Protection for the Construction Site 8.1 Introduction. 8.2 Administration. 8.3 Site Clearing, Excavation, Tunneling, and Construction Equipment. |
28 | 8.4 Construction Warehouses, Shops, and Offices. |
29 | 8.5 Construction Site Lay-Down Areas. 8.6 Temporary Construction Materials. 8.7 Underground Mains, Hydrants, and Water Supplies. 8.8 Manual Fire-Fighting Equipment. |
30 | Chapter 9 Fuels, Common Equipment, and Protection 9.1 General. 9.2 Fuel Handling — GasFlammable Gases. 9.3 Fuel Handling — OilCombustible Liquids. |
31 | 9.4 Flammable Liquids. 9.5 Solid Fuels. |
34 | 9.6 Hydraulic Control System. |
35 | 9.7 Electrical Equipment. |
36 | 9.8 Storage Rooms, Offices, and Shops. 9.9 Oil Storage Areas. 9.10 Warehouses. 9.11 Fire Pumps. 9.12 Cooling Towers. 9.13 Auxiliary Boilers. 9.14 Vehicle Repair Facilities. 9.15 Air Compressors. Chapter 10 Turbines, Generators, and Internal Combustion Engines 10.1 General. 10.2 Application of Chapters 4 through 7, 15, and 16Through 9. |
37 | 10.3 Combustion Turbine and Internal Combustion Engine Generators. |
39 | 10.4 Combined Cycle Units. Chapter 11 Alternative Fuels 11.1 General. |
40 | 11.2 Application of Chapters 4 Through 10. 11.3 Design and Equipment Arrangement. 11.4 Risk Considerations for MSW. 11.5 Risk Considerations for RDF. |
42 | 11.6 Risk Considerations for Biomass Fuels. 11.7 Risk Considerations for Tire Derived Fuels. |
43 | 11.8 Other Alternative Fuels and Processes. Chapter 12 Power Boilers 12.1 General. 12.2 Application of Chapters 4 through 7, 16, and 17Through 11. 12.3 Design and Equipment Arrangement. |
46 | Chapter 13 Wind Turbines 13.1 General. |
47 | 13.2 Application of Chapters 4 through 7 and 16 and 17Through 10. 13.3 General Design and Equipment Arrangement. 13.4 Risk Consideration. 13.5 Hazard Protection. |
48 | Chapter 14 Solar Generation 14.1 General. 14.2 Application of Chapters 4 through 7, 16, and 17Through 10. 14.3 Heat Transfer Fluid (HTF)Design and Equipment Arrangement. |
49 | 14.4 Risk Considerations. 14.5 FireHazard Protection. |
50 | Chapter 15 Geothermal Generation 15.1 General. 15.2 Application of Chapters 4 through 7, 16, and 17Through 10. 15.3 Design and Equipment Arrangement. 15.4 Fire ProtectionRisk Considerations. 15.5 Hazard Protection. Chapter 16 Integrated Gasification Combined-Cycle (IGCC) 16.1 General. 16.2 Application of Chapters 4 through 7, 16, and 17Through 10. 16.3 General Design and Equipment Arrangement. |
51 | 16.4 Emergency ResponseRisk Considerations. |
52 | 16.5 FireHazard Protection. Chapter 17 Hydroelectric Generation 17.1 General. 17.2 Application of Chapters 4 through 7 and 16 and 17Through 10. 17.3 General Design and Equipment Arrangement. |
53 | 17.4 Risk Considerations. (Reserved) 17.5 Hazard Protection. Chapter 18 High-Voltage Direct Current (HVDC) Converter Stations 18.1 General. 18.2 Application of Chapters 4 through 7, 16, and 17Through 9. 18.3 PlantDesign and Equipment Arrangement. |
54 | 18.4 HVDC Converter StationsRisk Considerations. 18.5 FireHazard Protection. Chapter 19 Flywheel Energy Systems 19.1 General. 19.2 Application of Chapters 4 Through 10. 19.3 Design and Equipment Arrangement. 19.4 Risk Consideration. |
55 | 19.5 Hazard Protection. |
56 | Chapter 20 Compressed Air Energy Storage (CAES) 20.1 General. 20.2 Application of Chapters 4 Through 10. 20.3 Design and Equipment Arrangement. 20.4 Risk Consideration. 20.5 Hazard Protection. Annex A Explanatory Material |
73 | Annex B Sample Fire Report |
75 | Annex C Fire Tests |
78 | Annex D Loss Experience |
82 | Annex E Fire Protection Design Basis Document |
83 | Annex F Informational References |