NFPA 99 2021
$80.71
NFPA 99: Health Care Facilities Code
Published By | Publication Date | Number of Pages |
NFPA | 2021 | 263 |
Access the latest knowledge and information on safeguarding lives and property in health care facilities with NFPA 99, 2021 edition. It is critical to take appropriate measures to protect patients, staff, and visitors from dangers and ensure health care safety. NFPA 99, Health Care Facilities Code, provides state-of-the-art performance criteria for health care facilities, materials, and appliances, including medical gas and vacuum systems, electrical systems, gas equipment, and features of fire protection. The code offers a risk-based approach that takes into account the particular hazards posed to occupants, rather than the building type, to determine safety guidelines. From provisions for installations, inspections, and testing to maintenance, performance, and safe practices, NFPA 99 is an essential resource for anyone who plays a role in facility safety. The Health Care Facilities Code provides the most current requirements for minimizing the risks of fire, explosion, and electricity. NFPA 99 was created to make it easier to adopt, use, and enforce a uniform approach and set of criteria for safety in hospitals, nursing homes, limited care settings, and other types of health care facilities. The 2021 edition introduces several substantial changes to the code, including: Revisions to the scope to include hyperbaric chambers for veterinary care New guidance describing what to do when clinical spaces are converted to nonclinical spaces with regard to medical gas inlets and outlets Introduction of the term responsible facility authority to the code with requirements for professional responsibilities and qualifications Removed existing language in Chapter 5 on cryogenic fluid central supply systems, replaced by extracts from NFPA 55 that cover the subject New section on health care microgrids in Chapter 6 Requirements for electrical equipment site acceptance testing and preventive electrical maintenance added to Chapter 6 Amended procedures for removing flammable liquid–soaked materials from the operating room to require those materials to be removed only from the patient care vicinity Requirements for the fire protection of heliports added to Chapter 16 by referencing NFPA 418 Elevate your facility’s approach to safety and get compliant with the 2021 code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Important Notices and Disclaimers |
3 | Additional Important Notices and Disclaimers |
17 | Chapter 1 Administration 1.1 Scope. |
18 | 1.2 Purpose. 1.3 Application. 1.4 Equivalency. 1.5 Units. 1.6 Code Adoption Requirements. Chapter 2 Referenced Publications 2.1 General. |
19 | 2.2 NFPA Publications. 2.3 Other Publications. |
21 | 2.4 References for Extracts in Mandatory Sections. |
22 | Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. |
30 | 3.4 BICSI Definitions. Chapter 4 Fundamentals 4.1 Risk Categories. 4.2 Risk Assessment. 4.3 Application. |
31 | 4.4 Materials. Chapter 5 Gas and Vacuum Systems 5.1 Category 1 Piped Gas and Vacuum Systems. |
75 | 5.2 Category 2 Piped Gas and Vacuum Systems. |
76 | 5.3 Category 3 Piped Gas and Vacuum Systems. |
78 | Chapter 6 Electrical Systems 6.1 Applicability. 6.2 Nature of Hazards. 6.3 General. |
83 | 6.4 Category 1 Spaces. 6.5 Category 2 Spaces. 6.6 Category 3 and 4 Spaces. 6.7 Essential Electrical Systems. |
91 | 6.8 Site Acceptance Testing. |
92 | 6.9 Electrical Preventive Maintenance (EPM). 6.10 Health Care Microgrids. |
94 | 6.11 Classification of Emergency Power Supply Systems (EPSSs). |
95 | Chapter 7 Information Technology and Communications Systems 7.1 Applicability. 7.2 Reserved. 7.3 Category 1 Systems. |
98 | 7.4 Category 2 Systems. |
99 | 7.5 Category 3 Systems. Chapter 8 Plumbing 8.1 Applicability. 8.2 System Category Criteria. |
100 | 8.3 General Requirements. 8.4 Category 1. (Reserved) 8.5 Category 2. (Reserved) 8.6 Category 3. (Reserved) Chapter 9 Heating, Ventilation, and Air Conditioning (HVAC) 9.1 Applicability. 9.2 System Category Criteria. 9.3 General. |
102 | 9.4 Category 1. (Reserved) 9.5 Category 2. (Reserved) 9.6 Category 3. (Reserved) Chapter 10 Electrical Equipment 10.1 Applicability. 10.2 Performance Criteria and Testing for Patient Care–Related Electrical Appliances and Equipment. |
103 | 10.3 Testing Requirements — Patient Care–Related Electrical Appliances and Equipment. |
104 | 10.4 Nonpatient Electrical Appliances and Equipment. 10.5 Administration. |
109 | Chapter 11 Gas Equipment 11.1 Applicability. 11.2 Portable Cylinder and Container Source. 11.3 Cylinder and Container Storage Requirements. |
111 | 11.4 Performance Criteria and Testing. 11.5 Administration. |
113 | 11.6 Operation and Management of Cylinders. |
115 | 11.7 Liquid Oxygen Equipment. |
116 | Chapter 12 Emergency Management 12.1 Applicability. 12.2 Responsibilities. 12.3 Emergency Management Categories. 12.4 General. 12.5 Emergency Management Category 1 and Emergency Management Category 2 Requirements. |
120 | Chapter 13 Security Management 13.1 Applicability. 13.2 Security Management Plan. 13.3 Security Vulnerability Assessment (SVA). 13.4 Responsible Person. |
121 | 13.5 Security-Sensitive Areas. 13.6 Access and Egress Security Measures. |
122 | 13.7 Media Control. 13.8 Crowd Control. 13.9 Access Control Equipment. 13.10 Employment Practices. 13.11 Security Operations. 13.12 Program Evaluation. Chapter 14 Hyperbaric Facilities 14.1 Scope. |
123 | 14.2 Construction and Equipment. |
131 | 14.3 Administration and Maintenance. |
135 | Chapter 15 Dental Gas and Vacuum Systems 15.1 Applicability. |
136 | 15.2 Nature of Hazards of Gas and Vacuum Systems. 15.3 Category 1 Dental Gas and Vacuum Systems. |
139 | 15.4 Category 2 Dental Gas and Vacuum Systems. |
152 | 15.5 Category 3 Dental Gas and Vacuum Systems. |
156 | Chapter 16 Features of Fire Protection 16.1 Applicability. 16.2 Construction and Compartmentation. 16.3 Special Hazard Protection for Flammable Liquids and Gases. 16.4 Laboratories. 16.5 Utilities. |
157 | 16.6 Waste Chutes, Incinerators, and Linen Chutes. 16.7 Fire Detection, Alarm, and Communications Systems. |
158 | 16.8 Heliports. 16.9 Automatic Sprinklers and Other Extinguishing Equipment. 16.10 Manual Extinguishing Equipment. 16.11 Compact Storage. 16.12 Compact Mobile Storage. 16.13 Maintenance and Testing. |
159 | 16.14 Fire Loss Prevention in Operating Rooms. Annex A Explanatory Material |
218 | Annex B Additional Explanatory Notes |
236 | Annex C Sample Ordinance Adopting NFPA 99 |
237 | Annex D Informational References |