NFPA Hdbk 13D R2013
$135.42
NFPA 13D and NFPA 13R: Automatic Sprinkler Systems for Residential Occupancies Handbook
Published By | Publication Date | Number of Pages |
NFPA | 2013 | 432 |
NFPA
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover Page |
4 | Copyright |
5 | Table of Content |
9 | Foreword by James M. Shannon |
11 | Preface |
13 | Acknowledgments |
15 | About the Contributors |
19 | About the Editor |
21 | PART ONE – NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, with Commentary |
23 | 1 Administration |
26 | 1.1 Scope |
31 | 1.2 Purpose |
36 | 1.3 Retroactivity |
39 | 1.4 Equivalency 1.5 Units |
40 | 1.6 New Technology |
43 | 2 Referenced Publications 2.1 General 2.2 NFPA Publications 2.3 Other Publications |
44 | 2.4 References for Extracts in Mandatory Sections |
45 | 3 Definitions 3.1 General 3.2 NFPA Official Definitions |
46 | 3.3 General Definitions |
55 | 4 General Requirements 4.1 Sprinkler Temperature Ratings 4.2 Tube 4.3 Listed or Labeled 4.4 Smoke Alarms |
56 | 4.5 Documentation 4.6 Qualifications |
57 | 5 System Components 5.1 General |
58 | 5.2 Aboveground Pipe and Equipment |
67 | 5.3 Underground Pipe |
68 | 5.4 Pre-Engineered Systems |
69 | 6 Water Supply 6.1 General Provisions |
70 | 6.2 Water Supply Sources |
75 | 6.3 Multipurpose Piping System |
77 | 6.4 Manufactured Home Water Supply |
78 | 6.5 Common Supply Pipes |
81 | 7 Installation 7.1 Valves |
83 | 7.2 Drains and Test Connections |
84 | 7.3 Pressure Gauges |
85 | 7.4 Piping Support 7.5 Sprinklers |
92 | 7.6 Alarms 7.7 Attics |
95 | 8 Sprinkler Position and Location 8.1 Design Criteria |
98 | 8.2 Position of Sprinklers |
118 | 8.3 Location of Sprinklers |
123 | 9 Protection from Freezing 9.1 System Types |
126 | 9.2 Antifreeze Systems |
137 | 9.3 Dry Pipe and Preaction Systems |
141 | 10 Discharge and Hydraulic Calculation 10.1 Design Discharge |
144 | 10.2 Number of Design Sprinklers |
148 | 10.3 Piping Configurations |
150 | 10.4 Pipe Sizing |
173 | 11 System Acceptance 11.1 General 11.2 Acceptance Tests |
177 | 12 Inspection, Testing and Maintenance 12.1 General |
178 | 12.2 Inspections and Tests 12.3 Maintenance |
183 | Annex A Explanatory Material |
185 | Annex B Informational References |
187 | PART TWO – NFPA 13R, Standard for the Installation of Sprinkler Systems Low-Rise Residential Occupancies, with Commentary |
189 | 1 Administration |
191 | 1.1 Scope |
197 | 1.2 Purpose |
202 | 1.3 Retroactivity |
203 | 1.4 Equivalency 1.5 Units |
204 | 1.6 New Technology |
205 | 2 Referenced Publications 2.1 General 2.2 NFPA Publications |
206 | 2.3 Other Publications |
207 | 2.4 References for Extracts in Mandatory Sections |
209 | 3 Definitions 3.1 General 3.2 NFPA Official Definitions |
211 | 3.3 General Definitions |
219 | 4 General Requirements 4.1 Sprinklered Throughout 4.2 Compartments 4.3 Basic Requirements |
220 | 4.4 Tube |
221 | 4.5 Listed or Labeled 4.6 System Arrangement |
223 | 5 System Components 5.1 General |
233 | 5.2 Aboveground Piping and Equipment |
243 | 5.3 Underground Pipe 5.4 System Types |
247 | 6 Installation 6.1 System Protection Area Limitations |
248 | 6.2 Use of Sprinklers |
258 | 6.3 Quick-Response Sprinklers 6.4 Residential Sprinklers |
274 | 6.5 Special Situations |
275 | 6.6 Location of Sprinklers |
282 | 6.7 Piping |
285 | 6.8 Valves |
286 | 6.9 Drains |
287 | 6.10 Test Connection |
288 | 6.11 Fire Department Connection |
289 | 6.12 Pressure Gauges |
290 | 6.13 Piping Support 6.14 Open-Grid Ceilings 6.15 Drop-Out Ceilings 6.16 Alarms |
293 | 7 Discharge Criteria 7.1 Design Criteria — Inside Dwelling Unit |
299 | 7.2 Design Criteria — Outside Dwelling Unit |
301 | 7.3 Design Criteria — Garages |
302 | 7.4 Pipe Sizing 7.5 Combustible Concealed Spaces |
303 | 8 Plans and Calculations 8.1 Working Plans |
307 | 9 Water Supply 9.1 Automatic 9.2 Minimum |
308 | 9.3 Source |
310 | 9.4 Fire Pump 9.5 Water Tanks |
311 | 9.6 Domestic Demand |
312 | 9.7 Non-Fire Protection Connections |
313 | 10 System Acceptance 10.1 Approval of Sprinkler Systems |
317 | 10.2 Acceptance Tests |
321 | 11 Care and Maintenance 11.1 Stock of Spare Sprinklers |
323 | 11.2 Owner’s Responsibility |
324 | 11.3 Inspection, Testing, and Maintenance 11.4 Instructions |
327 | Annex A Explanatory Material |
329 | Annex B Informational References |
331 | PART THREE – Supplements |
333 | 1 A History of Residential Sprinkler Use in the United States |
345 | 2 Obstructions to Residential Sprinklers |
363 | 3 Analysis of the Performance of Residential Sprinkler Systems with Sloped or Sloped and Beamed Ceilings |
365 | 4 Pedestal/Podium Building Design Using Model Building Codes and NFPA Sprinkler Standards |
373 | 5 Technical/Substantive Changes from the 2010 to 2013 Editions of NFPA 13D and NFPA 13R |
391 | PART FOUR – Addenda |
393 | 1 Environmental Impact of Automatic Fire Sprinklers |
395 | 2 Home Fire Sprinkler Coalition |
403 | 3 Communities with Home Fire Sprinklers: The Experience in Bucks County, Pennsylvania |
405 | 4 Cost Effectiveness of Sprinklers |
407 | 5 Comparative Analysis of Housing Cost and Supply Impacts of Sprinkler Ordinances at the Community Level |
421 | NFPA 13D Index |
425 | NFPA 13R Index |
429 | Important Notices and Legal Disclaimers |