Shopping Cart

No products in the cart.

NFPA Hdbk 25 2014

$135.42

NFPA 25: Water-Based Fire Protection Systems Handbook

Published By Publication Date Number of Pages
NFPA 2014 696
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ITM questions? The 2014 NFPA 25 Handbook has the answers you need to conduct efficient safety checks and avoid sprinkler failures. Because errors or oversights in sprinkler upkeep could result in fire tragedies and fire loss, it\’s vital not only to work with the latest ITM requirements, but also to make sure you apply them correctly. And that\’s exactly what the comprehensive 2014 Water-Based Fire Protection Systems Handbook is designed to do. This essential NFPA 25 companion strengthens your understanding of the intent behind rules and the function of the systems and components covered in the Standard so you can improve sprinkler reliability and increase equipment service life. The complete 2014 NFPA 25: Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems text is included for convenient reference and enhanced by explanations and practical application advice. Case studies provide examples of real-world sprinkler experience. 100+ full-color photos, charts, illustrations, and other visuals clarify concepts. Sample inspection, testing, and maintenance forms help in implementing your own procedures. Updated FAQs highlight key topics. NEW 2014 features include: Step-by-step testing procedures provide an example of a correct and proven way to conduct a test. ITM vs Design Evaluation feature presents specific examples and helps users determine whether or not something is within the scope of NFPA 25 (ITM) or out of scope (Design Evaluation). Four new supplements expand your expertise — Fire Pump Flow Test Analysis, Role of the AHJ, Inspection Roles and Responsibilities (Table), and Fire Pump Field Data Collection and Analysis. Anyone who works with sprinklers — from sprinkler contractors, service contract providers, facility managers, and building owners to engineers and designers, consultants, AHJs, insurance representatives and NFPA 13: Installation of Sprinkler System users — needs the 2014 NFPA 25 Handbook to ensure water-based systems are up-to-code and ready to protect lives and property.

PDF Catalog

PDF Pages PDF Title
1 Cover
2 Copyright
3 Table of Contents
5 Preface
7 About the Contributors
10 About the Editor
13 PART ONE – NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2014 Edition, with Commentary
15 1 Administration
1.1 Scope
20 1.2 Purpose
21 1.3 Application
22 1.4 Units
25 2 Referenced Publications
2.1 General
2.2 NFPA Publications
26 2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
27 3 Definitions
3.1 General
3.2 NFPA Official Definitions
29 3.3 General Definitions
74 3.4 Deluge Foam-Water Sprinkler and Foam- Water Spray Systems Definitions
75 3.5 Valve Definitions
77 3.6 Water-Based Fire Protection System Definitions
85 3.7 ITM Task Frequencies
89 4 General Requirements
4.1 Responsibility of Property Owner or Designated Representative
104 4.2 Manufacturer’s Corrective Action
4.3 Records
107 4.4 Water Supply Status
4.5 Inspection
108 4.6 Testing
109 4.7 Performanced-Based Programs
111 4.8 Maintenance
112 4.9 Safety
125 5 Sprinkler Systems
5.1 General
127 5.2 Inspection
157 5.3 Testing
173 5.4 Maintenance
179 5.5 Component Action Requirements
185 6 Standpipe and Hose Systems
186 6.1 General
189 6.2 Inspection
191 6.3 Testing
195 6.4 Maintenance
6.5 Component Action Requirements
201 7 Private Fire Service Mains
7.1 General
204 7.2 Inspection and Corrective Action
211 7.3 Testing
212 7.4 Maintenance
213 7.5 Component Action Requirements
221 8 Fire Pumps
8.1 General
239 8.2 Inspection
249 8.3 Testing
275 8.4 Reports
8.5 Maintenance
277 8.6 Component Replacement Testing Requirements
301 9 Water Storage Tanks
302 9.1 General
308 9.2 Inspection
318 9.3 Testing
321 9.4 Maintenance
322 9.5 Automatic Tank Fill Valves
325 9.6 Component Action Requirements
333 10 Water Spray Fixed Systems
334 10.1 General
341 10.2 Inspection and Maintenance Procedures
349 10.3 Operational Tests
353 10.4 Ultra-High-Speed Water Spray System (UHSWSS) Operational Tests
10.5 Component Action Requirements
357 11 Foam-Water Sprinkler Systems
358 11.1 General
362 11.2 Inspection
368 11.3 Operational Tests
373 11.4 Maintenance
375 11.5 Component Action Requirements
383 12 Water Mist Systems
384 12.1 Inspection and Testing
402 12.2 Maintenance
404 12.3 Training
407 13 Valves, Valve Components, and Trim
13.1 General
419 13.2 General Provisions
427 13.3 Control Valves in Water-Based Fire Protection Systems
433 13.4 System Valves
447 13.5 Pressure-Reducing Valves and Relief Valves
456 13.6 Backflow Prevention Assemblies
457 13.7 Fire Department Connections
461 13.8 Component Testing Requirements
487 14 Internal Piping Condition and Obstruction Investigation
14.1 General
14.2 Assessment of Internal Condition of Piping
498 14.3 Obstruction Investigation and Prevention
501 14.4 Ice Obstruction
503 15 Impairments
15.1 General
504 15.2 Impairment Coordinator
15.3 Tag Impairment System
505 15.4 Impaired Equipment
506 15.5 Preplanned Impairment Programs
509 15.6 Emergency Impairments
510 15.7 Restoring Systems to Service
513 16 Special Requirements from Other NFPA Documents
16.1 General
514 16.2 Small Residential Board and Care Occupancies
517 ANNEXES
A Explanatory Material
519 B Forms for Testing, Inspection, and Maintenance
521 C Possible Causes of Pump Troubles
529 D Obstruction Investigation
549 E Hazard Evaluation Form
555 F Informational References
559 PART TWO – Supplements
561 1 Microbiologically Influenced Corrosion in Fire Sprinkler Systems
573 2 Conducting Fire Pump Flow Tests
593 3 ITM Roles and Responsibilities
603 4 Role of the Inspector
617 5 Role of the Owner or Designated Representative
629 6 Role of the Authority Having Jurisdiction
643 7 Fire Pump Field Data Collection and Analysis
647 8 Technical/Substantive Changes from the 2011 Edition to the 2014 Edition of NFPA 25
679 Index
689 Important Notices and Legal Disclaimers
NFPA Hdbk 25 2014
$135.42