Shopping Cart

No products in the cart.

NJ ResidentialCode 2015

$63.92

International Residential Code, New Jersey Edition

Published By Publication Date Number of Pages
NJ 2015 698
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2015 International Residential Code

PDF Catalog

PDF Pages PDF Title
1 INTERNATIONAL RESIDENTIAL CODE® NEW JERSEY EDITION 2015
2 COPYRIGHT
3 PREFACE
7 EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE
17 TABLE OF CONTENTS
23 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND ADMINISTRATION DELETED
25 PART II—DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
41 PART III—BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R300 HEIGHT AND AREA LIMITATIONS
SECTION R301 DESIGN CRITERIA
43 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
44 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD) (psf)a, b, c, d, e
45 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
FIGURE R301.2(1) ISOLINES OF THE 97 1/2 -PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F)
46 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES—SITE CLASS D
47 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
48 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
49 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
50 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
51 FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETEa, b
52 FIGURE R301.2(4) AULTIMATE DESIGN WIND SPEEDS
53 FIGURE R301.2(4) BREGIONS WHERE WIND DESIGN IS REQUIRED
54 FIGURE R301.2(5) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
55 FIGURE R301.2(5)—continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
56 FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP
57 FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
TABLE R301.2.1.3 WIND SPEED CONVERSIONSa
58 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
59 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
60 TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSb, c
SECTION R302 FIRE-RESISTANT CONSTRUCTION
61 TABLE R302.1(1) EXTERIOR WALLS
TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS WITH FIRE SPRINKLERS
63 TABLE R302.6 DWELLING-GARAGE SEPARATION
65 SECTION R303 LIGHT, VENTILATION AND HEATING
66 SECTION R304 MINIMUM ROOM AREAS
67 SECTION R305 CEILING HEIGHT
SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
68 TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
69 FIGURE R308.4.7 PROHIBITED GLAZING LOCATIONS AT BOTTOM STAIR LANDINGS
70 SECTION R309 GARAGES AND CARPORTS
71 SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
72 SECTION R311 MEANS OF EGRESS
75 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS
76 SECTION R314 SMOKE ALARMS
SECTION R315 CARBON MONOXIDE ALARMS
77 SECTION R316 FOAM PLASTIC
79 SECTION R317 PROTECTION OF WOOD AND WOOD-BASED PRODUCTS AGAINST DECAY
80 SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES
81 SECTION R319 SITE ADDRESS
SECTION R320 ACCESSIBILITY DELETED
SECTION 321 ELEVATORS AND PLATFORM LIFTS DELETED
SECTION R322 FLOOD-RESISTANT CONSTRUCTION
83 SECTION R323 STORM SHELTERS DELETED
SECTION 324 SOLAR ENERGY SYSTEMS
84 SECTION R325 MEZZANINES
SECTION R326 SWIMMING POOLS, SPAS AND HOT TUBS
87 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
SECTION R402 MATERIALS
88 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
89 TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION (inches)a, b
90 TABLE R403.1(2) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION WITH BRICK VENEER (inches)a, b
91 TABLE R403.1(3) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS WITH CAST-IN-PLACE CONCRETE OR FULLY GROUTED MASONRY WALL CONSTRUCTION (inches)a, b
93 FIGURE R403.1(1) PLAIN CONCRETE FOOTINGS WITH MASONRY AND CONCRETE STEM WALLS IN SDC A, B AND Ca, b, c, d, e, f
94 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
95 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
96 FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY AND CONCRETE STEM WALLS IN SDC D0, D1 AND D2a, b, c, d, e, f,
98 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
100 FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
101 FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
102 TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
103 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
104 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
105 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
106 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
107 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
108 FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGSa (D), (inches)
109 FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
SECTION R404 FOUNDATION AND RETAINING WALLS
110 TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLSf
111 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 5 INCHESa, c, f
112 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 6.75 INCHESa, c, f
113 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 8.75 INCHESa, c, f
114 TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLSa, b
115 TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, g, h, i, j, k
116 TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i, j
117 TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i, j
118 TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, g, h, i, j
119 TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, f, h, i, j, k
120 TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLSb, c, d, e, g, h, i, j
121 TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10- AND 12-INCH NOMINAL FLAT BASEMENT WALLSb, c, d, e, f, h, i, k, n, o
122 TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEELa, b, c
125 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
127 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
SECTION R405 FOUNDATION DRAINAGE DELETED
SECTION R406 DAMPPROOFING AND WATERPROOFING
128 TABLE R406.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
129 SECTION R407 COLUMNS
SECTION R408 UNDER-FLOOR SPACE
131 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
132 FIGURE R502.2 FLOOR CONSTRUCTION
133 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/∆ = 360)a
134 TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/∆ = 360)a
135 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/∆ = 360)b
136 TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/∆ = 360)b
137 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf)
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f
139 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
140 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
141 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c
SECTION R504 PRESSURE PRESERVATIVE TREATED WOOD FLOORS (ON GROUND)
142 SECTION R505 COLD-FORMED STEEL FLOOR FRAMING
FIGURE R505.1.2 IN-LINE FRAMING
143 FIGURE R505.2.3(1) C-SHAPED SECTION
FIGURE R505.2.3(2) TRACK SECTION
TABLE R505.2.3 COLD-FORMED STEEL JOIST SIZES AND THICKNESS
144 FIGURE R505.2.6.1 FLOOR JOIST WEB HOLES
145 FIGURE R505.2.6.3 FLOOR JOIST WEB HOLE PATCH
TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTSa, b
146 TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE 505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION
147 FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION
148 FIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION
149 FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
150 FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
151 TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE OR CONTINUOUS SPANSa, b, c, d, e
152 FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP)
153 FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
154 FIGURE R505.3.4(2) BEARING STIFFENER
FIGURE R505.3.7 TRACK SPLICE
155 FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION—6-FOOT FLOOR OPENING
FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING
156 FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
157 SECTION R506 CONCRETE FLOORS (ON GROUND)
SECTION R507 EXTERIOR DECKS
158 TABLE R507.2 DECK LEDGER CONNECTION TO BAND JOISTa, b (Deck live load = 40 psf, deck dead load = 10 psf, snow load ≤ 40 psf)
TABLE 507.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS
159 FIGURE R507.2.1(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS
FIGURE R507.2.1(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS
160 FIGURE 507.2.3(1) DECK ATTACHMENT FOR LATERAL LOADS
FIGURE R507.2.3(2) DECK ATTACHMENT FOR LATERAL LOADS
161 TABLE R507.4 MAXIMUM JOIST SPACING
TABLE R507.5 DECK JOIST SPANS FOR COMMON LUMBER SPECIESf (ft. – in.)
FIGURE R507.5 TYPICAL DECK JOIST SPANS
162 TABLE R507.6 DECK BEAM SPAN LENGTHSa, b (ft. – in.)
FIGURE R507.6 TYPICAL DECK BEAM SPANS
163 TABLE R507.8 DECK POST HEIGHTa
FIGURE R507.7.1 DECK BEAM TO DECK POST
FIGURE R507.8.1 TYPICAL DECK POSTS TO DECK FOOTINGS
165 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
166 TABLE R602.3(1) FASTENING SCHEDULE
167 TABLE R602.3(1)—continued FASTENING SCHEDULE
168 TABLE 602.3(1) FASTENING SCHEDULE—continued
169 TABLE R602.3(1)—continued FASTENING SCHEDULE
TABLE R602.3.2 SINGLE TOP-PLATE SPLICE CONNECTION DETAILS
170 TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
171 TABLE R602.3(2)—continued ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa, b, c
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa
172 TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
173 FIGURE R602.3(2) FRAMING DETAILS
175 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
176 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
177 TABLE R602.7(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
178 TABLE R602.7(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
179 TABLE R602.7(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R602.7(3) GIRDER AND HEADER SPANSa FOR OPEN PORCHES (Maximum span for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb)
180 FIGURE R602.7.1(1) SINGLE MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE R602.7.1(2) ALTERNATIVE SINGLE MEMBER HEADER WITHOUT CRIPPLE
FIGURE R602.7.2 RIM BOARD HEADER CONSTRUCTION
181 TABLE R602.7.3 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.3 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
182 TABLE R602.7.5 MINIMUM NUMBER OF FULL HEIGHT STUDSAT EACH END OF HEADERS IN EXTERIOR WALLS
FIGURE R602.10.1.1 BRACED WALL LINES
183 TABLE R602.10.1.3 BRACED WALL LINE SPACING
FIGURE R602.10.1.4 ANGLED WALLS
184 FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS
186 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
187 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
188 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
189 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
190 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
191 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
192 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
193 TABLE R602.10.4 BRACING METHODS
194 TABLE R602.10.4—continued BRACING METHODS
195 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
196 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
197 TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL
198 FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS
FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
199 FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
200 TABLE R602.10.6.4 TENSION STRAP CAPACITY FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHODS PFH, PFG AND CS-PF BRACED WALL PANELS
201 TABLE R602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS
202 FIGURE R602.10.6.5 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2
203 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
204 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
205 FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
FIGURE R602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
206 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
208 FIGURE R602.11. 2STEPPED FOUNDATION CONSTRUCTION
209 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
210 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
211 FIGURE R602.12.5 BRACING UNIT DISTRIBUTION
SECTION R603 COLD-FORMED STEEL WALL FRAMING
212 FIGURE R603.1.2 IN-LINE FRAMING
FIGURE R603.2.3(1) C-SHAPED SECTION
FIGURE R603.2.3(2) TRACK SECTION
213 TABLE R603.2.3 LOAD-BEARING COLD-FORMED STEEL STUD SIZES AND THICKNESSES
FIGURE R603.2.6.1 WALL STUD WEB HOLES
214 FIGURE R603.2.6.3 WALL STUD WEB HOLE PATCH
215 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa, b
216 TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTSa, b, c
TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTSa, b, c
FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
217 FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
218 FIGURE R603.3.1(4) WIND UPLIFT CONNECTOR
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
219 TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
220 TABLE R603.3.2(3) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
221 TABLE R603.3.2(4) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
222 TABLE R603.3.2(5) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
223 TABLE R603.3.2(6) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
224 TABLE R603.3.2(7) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
225 TABLE R603.3.2(8) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
226 TABLE R603.3.2(9) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
227 TABLE R603.3.2(10) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
228 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
229 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
230 TABLE R603.3.2(13) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
231 TABLE R603.3.2(14) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
232 TABLE R603.3.2(15) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
233 TABLE R603.3.2(16) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
234 TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa, b, c, d
235 TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa, b, c, d
236 FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
237 FIGURE R603.3.5 TRACK SPLICE
FIGURE R603.4 CORNER FRAMING
238 FIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(2) BACK-TO-BACK HEADER
239 TABLE R603.6(1) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
240 TABLE R603.6(2) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
241 TABLE R603.6(3) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
242 TABLE R603.6(4) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
243 TABLE R603.6(5) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
244 TABLE R603.6(6) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
245 FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
246 TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d
247 TABLE R603.8 HEAD AND SILL TRACK SPAN
FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
248 TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL-HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa, b
TABLE R603.9.2(2) FULL-HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
FIGURE R603.9.4.2 CORNER STUD HOLD-DOWN DETAIL
249 TABLE R603.9.5(1) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
250 TABLE R603.9.5(2) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
251 TABLE R603.9.5(3) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
252 TABLE R603.9.5(4) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
SECTION R606 GENERAL MASONRY CONSTRUCTION
253 TABLE R606.2.7 MORTAR PROPORTIONSa, b
254 TABLE R606.2.11 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
TABLE R606.3.4.1 MINIMUM CORROSION PROTECTION
255 TABLE R606.3.5.1 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
256 TABLE R606.6.4 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
258 TABLE R606.9 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
259 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
260 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
261 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1 OR D2
262 TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
263 TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
264 SECTION R607 GLASS UNIT MASONRY
265 FIGURE R607.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
266 SECTION R608 EXTERIOR CONCRETE WALL CONSTRUCTION
267 TABLE R608.3 DIMENSIONAL REQUIREMENTS FOR WALLSa, b
FIGURE R608.3(1) FLAT WALL SYSTEM
268 FIGURE R6083(2) WAFFLE-GRID WALL SYSTEM
FIGURE R608.3(3) SCREEN-GRID WALL SYSTEM
270 TABLE R608.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
FIGURE R608.5.4(1) LAP SPLICES
271 FIGURE R608.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
FIGURE R608.5.4(3) STANDARD HOOKS
272 TABLE R608.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND/OR ALTERNATIVE GRADE OF STEELa, b, c
274 FIGURE R608.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R608.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST STORY AND LIGHT-FRAMED SECOND STORY
FIGURE R608.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R608.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING
275 TABLE R608.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLSa, b, c, d, e
276 TABLE R608.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLSa, b, c, d, e
277 TABLE R608.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLSa, b, c, d, e
278 TABLE R608.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l
279 EQUATION R6-1
EQUATION R6-2
280 TABLE R608.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
281 TABLE R608.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
282 TABLE R608.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
283 TABLE R608.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
284 TABLE R608.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
285 TABLE R608.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
286 TABLE R608.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
TABLE R608.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEETa, b
287 TABLE R608.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLSa, c
288 FIGURE R608.7(1) MINIMUM SOLID WALL LENGTH
290 FIGURE R608.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
291 FIGURE R608.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
292 FIGURE R608.8(1) REINFORCEMENT OF OPENINGS
293 FIGURE R608.8(2) LINTEL FOR FLAT WALLS
FIGURE R608.8(3) LINTELS FOR WAFFLE-GRID WALLS
294 FIGURE R608.8(4) LINTELS FOR SCREEN-GRID WALLS
295 TABLE R608.8(1) LINTEL DESIGN LOADING CONDITIONSa, b, d
296 TABLE R608.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
297 TABLE R608.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
298 TABLE R608.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
299 TABLE R608.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
300 TABLE R608.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
301 TABLE R608.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
302 TABLE R608.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
303 TABLE R608.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
304 TABLE R608.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
305 TABLE R608.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
306 TABLE R608.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
307 TABLE R608.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
308 TABLE R608.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
309 TABLE R608.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h
310 TABLE R608.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h
TABLE R608.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSc, d, e, f, g
312 FIGURE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
313 TABLE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b
314 FIGURE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
315 TABLE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b
316 FIGURE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING, PERPENDICULAR
317 TABLE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
318 FIGURE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
319 TABLE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
320 FIGURE R608.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
321 TABLE R608.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c
322 FIGURE R608.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
323 TABLE R608.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b, c
324 FIGURE R608.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
325 TABLE R608.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
326 FIGURE R608.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
327 TABLE R608.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
328 FIGURE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
329 TABLE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
330 FIGURE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
331 TABLE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
332 FIGURE R608.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
333 TABLE R608.9(11) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
334 FIGURE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
335 TABLE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
336 SECTION R609 EXTERIOR WINDOWS AND DOORS
337 FIGURE R609.7.2(1) THROUGH THE FRAME
FIGURE R609.7.2(2) FRAME CLIP
FIGURE R609.7.2(3) THROUGH THE FRAME
FIGURE R609.7.2(4) FRAME CLIP
338 FIGURE R609.7.2(5) THROUGH THE FLANGE
FIGURE R609.7.2(6) THROUGH THE FLANGE
FIGURE R609.7.2(7) FRAME CLIP
FIGURE R609.7.2(8) THROUGH THE FLANGE
339 SECTION R610 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
TABLE R610.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE
340 TABLE R610.3.2 MINIMUM PROPERTIESa FOR ORIENTED STRAND BOARD FACER MATERIAL IN SIP WALLS
FIGURE R610.4 SIP WALL PANEL
341 TABLE R610.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY (inches)a
342 TABLE R610.5(2) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF ONLY (inches)a
343 FIGURE R610.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R610.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
344 FIGURE R610.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R610.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
345 FIGURE R610.5(5) SIP WALL-TO-WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only)
FIGURE R610.5.1 SIP WALL FRAMING CONFIGURATION
346 FIGURE R610.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
347 FIGURE R610.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS
348 FIGURE R610.9 SIP CORNER FRAMING DETAIL
TABLE R610.10 MAXIMUM SPANS FOR 117/8-INCH-DEEP SIP HEADERS (feet)a
349 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
350 TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
351 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD AND GYPSUM PANEL PRODUCTS
352 TABLE R702.3.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE R702.4.2 BACKER BOARD MATERIALS
353 TABLE R702.7.1 CLASS III VAPOR RETARDERS
SECTION R703 EXTERIOR COVERING
354 TABLE R703.3(2) SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTIONa, b, c, d, e
TABLE R703.3.1 LIMITS FOR ATTACHMENT PER TABLE R703.3(1)
355 TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
356 TABLE R703.3(1)—continued SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
357 TABLE R703.3.2 OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
358 TABLE R703.6.1 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c (Dimensions are in inches)
359 TABLE R703.6.3(1) SINGLE COURSE SIDEWALL FASTENERS
TABLE R703.6.3(2) DOUBLE COURSE SIDEWALL FASTENERS
361 FIGURE R703.8 TYPICAL MASONRY VENEER WALL DETAILS
362 FIGURE R703.8—continued TYPICAL MASONRY VENEER WALL DETAILSe
363 TABLE R703.8(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.8(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
364 FIGURE R703.8.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.8.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
365 TABLE R703.8.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d
TABLE R703.8.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
FIGURE R703.8.3.2 MASONRY VENEER OPENING
366 TABLE R703.8.4 TIE ATTACHMENT AND AIRSPACE REQUIREMENTS
369 TABLE R703.15.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
TABLE R703.15.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa, b
370 TABLE R703.16.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
371 TABLE R703.16.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
373 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
375 TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
376 TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
377 TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
378 TABLE R802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
381 TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
382 TABLE R802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
383 TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
384 TABLE R802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
385 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
386 TABLE R802.5.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
387 TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
388 TABLE R802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
389 TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
390 TABLE R802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
391 TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
392 TABLE R802.5.1(7)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
393 TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
394 TABLE R802.5.1(8)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
395 TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa, b, c, d, e, f, h
396 FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION
397 FIGURE R802.7.1.1 RAFTER NOTCH
FIGURE R802.7.1.2 CEILING JOIST TAPER CUT
399 TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION)a, b, c, d, e, f, g, h
400 TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (POUNDS PER CONNECTION)a, b, c, d, e, f, g, h
401 SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
SECTION R804 COLD-FORMED STEEL ROOF FRAMING
402 FIGURE R804.1.2 IN-LINE FRAMING
403 TABLE R804.2.3 LOAD-BEARING COLD-FORMED STEEL ROOF FRAMING MEMBER SIZES AND THICKNESSES
FIGURE R804.2.3(1) C-SHAPED SECTION
FIGURE R804.2.3(2) TRACK SECTION
404 FIGURE R804.2.6.1 ROOF FRAMING MEMBER WEB HOLES
FIGURE R804.2.6.3 ROOF FRAMING MEMBER WEB HOLE PATCH
405 FIGURE R804.3 COLD-FORMED STEEL ROOF CONSTRUCTION
TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa, b
406 TABLE R804.3.1.1(1) CEILING JOIST SPANS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b, c
407 TABLE R804.3.1.1(2) CEILING JOIST SPANS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c
408 TABLE R804.3.1.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
FIGURE R804.3.1.1 JOIST TO RAFTER CONNECTION
409 FIGURE R804.3.1.3(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPED, TRACK OR COLD-ROLLED CHANNEL
410 FIGURE R804.3.1.3(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
FIGURE R804.3.1.4 SPLICED CEILING JOISTS
411 TABLE R804.3.2.1(1) ROOF RAFTER SPANSa, b, c, d
412 TABLE R804.3.2.1(2) ULTIMATE DESIGN WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
413 FIGURE R804.3.2.4 RIDGE MEMBER CONNECTION
TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
414 FIGURE R804.3.5(1) ROOF OR CEILING OPENING
FIGURE R804.3.5(2) HEADER TO TRIMMER CONNECTION
415 TABLE R804.3.7.1 REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEETa, b, c, d, e, f, g
416 FIGURE R804.3.7.1(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
FIGURE R804.3.7.1(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
417 FIGURE R804.3.7(2) ROOF BLOCKING DETAIL
SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
418 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
419 SECTION R807 ATTIC ACCESS
421 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 FIRE CLASSIFICATION
SECTION R903 WEATHER PROTECTION
422 SECTION R904 MATERIALS
SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
TABLE R905.1.1(1) UNDERLAYMENT TYPES
423 TABLE R905.1.1(2) UNDERLAYMENT APPLICATION
424 TABLE R905.1.1(3) UNDERLAYMENT ATTACHMENT
425 TABLE R905.2.4.1 CLASSIFICATION OF ASPHALT ROOF SHINGLES
426 TABLE R905.2.8.2 VALLEY LINING MATERIAL
427 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
428 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
429 TABLE R905.7.5(1) WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.7.5(2) NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES
TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
430 TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
431 TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
432 TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS
433 SECTION R906 ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 ROOFTOP-MOUNTED PHOTOVOLTAIC SYSTEMS
SECTION R908 REROOFING
434 SECTION R909 ROOFTOP-MOUNTED PHOTOVOLTAIC PANEL SYSTEMS
435 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
436 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
437 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
438 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
439 SECTION R1002 MASONRY HEATERS
SECTION R1003 MASONRY CHIMNEYS
441 TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
442 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
443 FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
TABLE R1003.20 CRICKET DIMENSIONS
FIGURE R1003.20 CHIMNEY CRICKET
444 SECTION R1004 FACTORY-BUILT FIREPLACES
SECTION R1005 FACTORY-BUILT CHIMNEYS
SECTION R1006 EXTERIOR AIR SUPPLY
445 PART IV—ENERGY CONSERVATION
CHAPTER 11 [RE] ENERGY EFFICIENCY
SECTION N1101 GENERAL
448 FIGURE N1101.7 (R301.1) CLIMATE ZONES
449 TABLE N1101.7 (R301.1) CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
450 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
451 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
452 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
453 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
454 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
455 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
456 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
457 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
458 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
459 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
460 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
461 TABLE N1101.7 (R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.7.2(1) [R302.3(1)] INTERNATIONAL CLIMATE ZONE DEFINITIONS
462 TABLE N1101.7.2(2) [R301.3(2)] INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE N1101.10.3(1) [R303.1.3(1)] DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE N1101.10.3(2) [R303.1.3(2)] DEFAULT DOOR U-FACTORS
463 TABLE N1101.10.3(3) [R303.1.3(3)] DEFAULT GLAZED FENESTRATION SHGC AND VT
SECTION N1102 (R402) BUILDING THERMAL ENVELOPE
464 TABLE N1102.1.2 (R402.1.2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE N1102.1.4 (R402.1.4) EQUIVALENT U-FACTORSa
466 TABLE N1102.2.6 (R402.2.6) STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
468 TABLE N1102.4.1.1 (402.4.1.1) AIR BARRIER AND INSULATION INSTALLATION
469 SECTION N1103 (R403) SYSTEMS
470 TABLE N1103.6.1 (R403.6.1) MECHANICAL VENTILATION SYSTEM FAN EFFICACY
471 SECTION N1104 (R404) ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
SECTION N1105 (R405) SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
473 TABLE N1105.5.2(1) [R405.5.2(1)] SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
474 TABLE N1105.5.2(1) [R405.5.2(1)]—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
475 TABLE N1105.5.2(2) [R405.5.2(2)] DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
SECTION N1106 (R406) ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
TABLE N1106.4 (R406.4) MAXIMUM ENERGY RATING INDEX
476 SECTION 1107 (R501) EXISTING BUILDINGS—GENERAL DELETED
SECTION N1108 (R502) ADDITIONS DELETED
SECTION N1109 (R503) ALTERATIONS DELETED
SECTION N1110 (R504) REPAIRS DELETED
SECTION N1111 (R505) CHANGE OF OCCUPANCY OR USE DELETED
477 PART V—MECHANICAL
CHAPTER 12 MECHANICAL ADMINISTRATION
SECTION M1201 GENERAL
SECTION M1202 EXISTING MECHANICAL SYSTEMS DELETED
479 CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS
SECTION M1301 GENERAL
SECTION M1302 APPROVAL
SECTION M1303 LABELING OF APPLIANCES
SECTION M1304 TYPE OF FUEL
SECTION M1305 APPLIANCE ACCESS
480 SECTION M1306 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
481 SECTION M1307 APPLIANCE INSTALLATION
482 TABLE M1306.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa, c, d, e, f, g, h, i, j, k, l
483 FIGURE M1306.1 REDUCED CLEARANCE DIAGRAM
FIGURE M1306.2 WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
484 SECTION M1308 MECHANICAL SYSTEMS INSTALLATION
485 CHAPTER 14 HEATING AND COOLING EQUIPMENT AND APPLIANCES
SECTION M1401 GENERAL
SECTION M1402 CENTRAL FURNACES
SECTION M1403 HEAT PUMP EQUIPMENT
SECTION M1404 REFRIGERATION COOLING EQUIPMENT
SECTION M1405 BASEBOARD CONVECTORS
SECTION M1406 RADIANT HEATING SYSTEMS
486 SECTION M1407 DUCT HEATERS
SECTION M1408 VENTED FLOOR FURNACES
487 SECTION M1409 VENTED WALL FURNACES
SECTION M1410 VENTED ROOM HEATERS
SECTION M1411 HEATING AND COOLING EQUIPMENT
488 SECTION M1412 ABSORPTION COOLING EQUIPMENT
SECTION M1413 EVAPORATIVE COOLING EQUIPMENT
SECTION M1414 FIREPLACE STOVES
489 SECTION M1415 MASONRY HEATERS
491 CHAPTER 15 EXHAUST SYSTEMS
SECTION M1501 GENERAL
SECTION M1502 CLOTHES DRYER EXHAUST
TABLE M1502.4.5.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
492 SECTION M1503 RANGE HOODS
SECTION M1504 INSTALLATION OF MICROWAVE OVENS
SECTION M1505 OVERHEAD EXHAUST HOODS
493 SECTION M1506 EXHAUST DUCTS AND EXHAUST OPENINGS
TABLE M1506.2 DUCT LENTH
SECTION M1507 MECHANICAL VENTILATION
494 TABLE M1507.3.3(1) CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS
TABLE M1507.3.3(2) INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa, b
TABLE M1507.4 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS
495 CHAPTER 16 DUCT SYSTEMS
SECTION M1601 DUCT CONSTRUCTION
496 TABLE M1601.1.1 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
498 SECTION M1602 RETURN AIR
499 CHAPTER 17 COMBUSTION AIR
SECTION M1701 GENERAL
501 CHAPTER 18 CHIMNEYS AND VENTS
SECTION M1801 GENERAL
502 SECTION M1802 VENT COMPONENTS
SECTION M1803 CHIMNEY AND VENT CONNECTORS
TABLE M1803.2 THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS
TABLE M1803.3.4 CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa
503 SECTION M1804 VENTS
TABLE M1804.1 VENT SELECTION CHART
SECTION M1805 MASONRY AND FACTORY-BUILT CHIMNEYS
505 CHAPTER 19 SPECIAL APPLIANCES, EQUIPMENT AND SYSTEMS
SECTION M1901 RANGES AND OVENS
SECTION M1902 SAUNA HEATERS
SECTION M1903 STATIONARY FUEL CELL POWER PLANTS
SECTION M1904 GASEOUS HYDROGEN SYSTEMS
507 CHAPTER 20 BOILERS AND WATER HEATERS
SECTION M2001 BOILERS
SECTION M2002 OPERATING AND SAFETY CONTROLS
SECTION M2003 EXPANSION TANKS
508 TABLE M2003.2 EXPANSION TANK MINIMUM CAPACITYaFOR FORCED HOT-WATER SYSTEMS
SECTION M2004 WATER HEATERS USED FOR SPACE HEATING
SECTION M2005 WATER HEATERS
SECTION M2006 POOL HEATERS
509 CHAPTER 21 HYDRONIC PIPING
SECTION M2101 HYDRONIC PIPING SYSTEMS INSTALLATION
TABLE M2101.9 HANGER SPACING INTERVALS
SECTION M2102 BASEBOARD CONVECTORS
SECTION M2103 FLOOR HEATING SYSTEMS
510 TABLE M2101.1 HYDRONIC PIPING MATERIALS
511 SECTION M2104 LOW TEMPERATURE PIPING
SECTION M2105 GROUND-SOURCE HEAT-PUMP SYSTEM LOOP PIPING
512 TABLE M2105.4 GROUND-SOURCE LOOP PIPE
TABLE M2105.5 GROUND-SOURCE LOOP PIPE FITTINGS
515 CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION M2201 OIL TANKS
SECTION M2202 OIL PIPING, FITTING AND CONNECTIONS
SECTION M2203 INSTALLATION
516 SECTION M2204 OIL PUMPS AND VALVES
517 CHAPTER 23 SOLAR THERMAL ENERGY SYSTEMS
SECTION M2301 THERMAL SOLAR ENERGY SYSTEMS
519 PART VI—FUEL GAS
CHAPTER 24 FUEL GAS
SECTION G2401 (101) GENERAL
SECTION G2402 (201) GENERAL
SECTION G2403 (202) GENERAL DEFINITIONS
525 SECTION G2404 (301) GENERAL
526 SECTION G2405 (302) STRUCTURAL SAFETY
SECTION G2406 (303) APPLIANCE LOCATION
527 SECTION G2407 (304) COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 24-1
EQUATION 24-2
FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING (see Section G2407.5.3)
528 FIGURE G2407.6.1(1) [304.6.1(1)] ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section G2407.6.1)
529 FIGURE G2407.6.1(2) [304.6.1(2)] ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section G2407.6.1)
FIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS (see Section G2407.6.1)
530 FIGURE G2407.6.2 (304.6.2) SINGLE COMBUSTION AIR OPENING, ALL AIR FROM OUTDOORS (see Section G2407.6.2)
531 SECTION G2408 (305) INSTALLATION
SECTION G2409 (308) CLEARANCE REDUCTION
532 FIGURE G2409.2(1) [308.2(1)] EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTORS
FIGURE G2409.2(2) [308.2(2)] WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
533 FIGURE G2409.2(3) [308.2(3)] MASONRY CLEARANCE REDUCTION SYSTEM
SECTION G2410 (309) ELECTRICAL
SECTION G2411 (310) ELECTRICAL BONDING
534 TABLE G2409.2 (308.2)a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
535 SECTION G2412 (401) GENERAL
SECTION G2413 (402) PIPE SIZING
536 EQUATION 24-3
EQUATION 24-4
TABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
SECTION G2414 (403) PIPING MATERIALS
537 TABLE G2413.4(1) [402.4(2)] SCHEDULE 40 METALLIC PIPE
538 TABLE G2413.4(2) [402.4(5)] SCHEDULE 40 METALLIC PIPE
539 TABLE G2413.4(3) [402.4(9)] SEMIRIGID COPPER TUBING
540 TABLE G2413.4(4) [402.4(12)] SEMIRIGID COPPER TUBING
541 TABLE G2413.4(5) [402.4(15)] CORRUGATED STAINLESS STEEL TUBING (CSST)
542 TABLE G2413.4(6) [402.4(18)] CORRUGATED STAINLESS STEEL TUBING (CSST)
543 TABLE G2413.4(7) [402.4(21)] POLYETHYLENE PLASTIC PIPE
544 TABLE G2413.4(8) [402.4(22)] POLYETHYLENE PLASTIC PIPE
545 TABLE G2413.4(9) [402.4(25)] SCHEDULE 40 METALLIC PIPE
546 TABLE G2413.4(10) [402.4(26)] SCHEDULE 40 METALLIC PIPE
547 TABLE G2413.4(11) [402.4(27)] SCHEDULE 40 METALLIC PIPE
548 TABLE G2413.4(12) [402.4(28)] SCHEDULE 40 METALLIC PIPE
549 TABLE G2413.4(13) [402.4(29)] SEMIRIGID COPPER TUBING
550 TABLE G2413.4(14) [402.4(30)] SEMIRIGID COPPER TUBING
551 TABLE G2413.4(15) [402.4(31)] SEMIRIGID COPPER TUBING
552 TABLE G2413.4(16) [402.4(32)] CORRUGATED STAINLESS STEEL TUBING (CSST)
553 TABLE G2413.4(17) [402.4(33)] CORRUGATED STAINLESS STEEL TUBING (CSST)
554 TABLE G2413.4(18) [402.4(34)] CORRUGATED STAINLESS STEEL TUBING (CSST)
555 TABLE G2413.4(19) [402.4(35)] POLYETHYLENE PLASTIC PIPE
556 TABLE G2413.4(20) [402.4(36)] POLYETHYLENE PLASTIC PIPE
557 TABLE G2413.4(21) [402.4(37)] POLYETHYLENE PLASTIC TUBING
558 TABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE
559 SECTION G2415 (404) PIPING SYSTEM INSTALLATION
561 SECTION G2416 (405) PIPING BENDS AND CHANGES IN DIRECTION
562 SECTION G2417 (406) INSPECTION, TESTING AND PURGING
563 TABLE G2417.7.1.1 (406.7.1.1) SIZE AND LENGTH OF PIPING
564 SECTION G2418 (407) PIPING SUPPORT
SECTION G2419 (408) DRIPS AND SLOPED PIPING
FIGURE G2419.4 (408.4) METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
565 SECTION G2420 (409) SHUTOFF VALVES
TABLE G2420.1.1 (409.1.1) MANUAL GAS VALVE STANDARDS
SECTION G2421 (410) FLOW CONTROLS
566 SECTION G2422 (411) APPLIANCE CONNECTIONS
567 SECTION G2423 (413) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION G2424 (415) PIPING SUPPORT INTERVALS
TABLE G2424.1 (415.1) SUPPORT OF PIPING
SECTION G2425 (501) GENERAL
568 SECTION G2426 (502) VENTS
569 SECTION G2427 (503) VENTING OF APPLIANCES
570 TABLE G2427.4 (503.4) TYPE OF VENTING SYSTEM TO BE USED
572 FIGURE G2427.6.3 (503.6.4) TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL
575 TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
576 TABLE G2427.10.5 (503.10.5) aCLEARANCES FOR CONNECTORS
578 SECTION G2428 (504) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
580 TABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH
582 TABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT
583 TABLE G2428.2(1) [504.2(1)]—continued TYPE B DOUBLE-WALL GAS VENT
584 TABLE G2428.2(2) [504.2(2)] TYPE B DOUBLE-WALL GAS VENT
585 TABLE G2428.2(2) [504.2(2)]—continued TYPE B DOUBLE-WALL GAS VENT
586 TABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT
587 TABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL VENT
588 TABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY
589 TABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY
590 SECTION G2429 (505) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION G2430 (506) FACTORY-BUILT CHIMNEYS
SECTION G2431 (601) GENERAL
SECTION G2432 (602) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION G2433 (603) LOG LIGHTERS
SECTION G2434 (604) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS
SECTION G2436 (608) VENTED WALL FURNACES
591 SECTION G2437 (609) FLOOR FURNACES
SECTION G2438 (613) CLOTHES DRYERS
SECTION G2439 (614) CLOTHES DRYER EXHAUST
592 TABLE G2439.7.4.1 (TABLE 614.8.4.1) DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
SECTION G2440 (615) SAUNA HEATERS
593 SECTION G2441 (617) POOL AND SPA HEATERS
SECTION G2442 (618) FORCED-AIR WARM-AIR FURNACES
594 SECTION G2443 (619) CONVERSION BURNERS
SECTION G2444 (620) UNIT HEATERS
SECTION G2445 (621) UNVENTED ROOM HEATERS
SECTION G2446 (622) VENTED ROOM HEATERS
SECTION G2447 (623) COOKING APPLIANCES
595 SECTION G2448 (624) WATER HEATERS
SECTION G2449 (627) AIR-CONDITIONING APPLIANCES
SECTION G2450 (628) ILLUMINATING APPLIANCES
596 SECTION G2451 (630) INFRARED RADIANT HEATERS
SECTION G2452 (631) BOILERS
SECTION G2453 (634) CHIMNEY DAMPER OPENING AREA
TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION G2454 (636) OUTDOOR DECORATIVE APPLIANCES
597 PART VII—PLUMBING
CHAPTERS 25 THROUGH 28 DELETED
599 CHAPTER 29 WATER SUPPLY AND DISTRIBUTION
SECTION P2901 GENERAL DELETED
SECTION P2902 PROTECTION OF POTABLE WATER SUPPLY DELETED
SECTION P2903 WATER SUPPLY SYSTEM DELETED
SECTION P2904 DWELLING UNIT FIRE SPRINKLER SYSTEMS
600 TABLE P2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
601 FIGURE P2904.2.4.2 MINIMUM ALLOWABLE DISTANCE BETWEEN SPRINKLER AND OBSTRUCTION
602 EQUATION 29-1
603 SECTION P2905 HEATED WATER DISTRIBUTION SYSTEMS DELETED
SECTION P2906 MATERIALS, JOINTS AND CONNECTIONS DELETED
SECTION P2907 CHANGES IN DIRECTION DELETED
SECTION P2908 SUPPORT DELETED
SECTION P2909 DRINKING WATER TREATMENT UNITS DELETED
SECTION P2910 NONPOTABLE WATER SYSTEMS DELETED
SECTION P2911 ON-SITE NONPOTABLE WATER REUSE SYSTEMS DELETED
SECTION P2912 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS DELETED
SECTION P2913 RECLAIMED WATER SYSTEMS DELETED
604 TABLE P2904.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a, b
TABLE P2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
605 TABLE P2904.6.2(3) ELEVATION LOSS (PLe)
606 TABLE P2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING
607 TABLE P2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
608 TABLE P2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
609 TABLE P2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
610 TABLE P2904.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX AND PE-RT TUBING
611 TABLE P2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX AND PE-RT TUBING
613 CHAPTERS 30 THROUGH 33 DELETED
615 PART VIII—ELECTRICAL
CHAPTER 34 THROUGH 43 DELETED
617 PART IX—REFERENCED STANDARDS
CHAPTER 44 REFERENCED STANDARDS
AAMA
ACI
618 ACCA
AISI
AMCA
AMD
ANCE
619 ANSI
620 APA
ASCE/SEI
ASHRAE
ASME
621 ASTM
627 AWC
628 AWPA
AWS
AWWA
CEN
CGSB
629 CPA
CPSC
CSA
CSSB
630 DASMA
DOC
DOTn
FEMA
FM
631 GA
HPVA
ICC
ISO
MSS
632 NAIMA
NFPA
NSF
PCA
633 SBCA
SMACNA
SRCC
TMS
TPI
634 UL
635 ULC
WDMA
637 APPENDIX A SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
638 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
639 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
640 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
642 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
643 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
644 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
645 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
646 FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
649 APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
650 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
651 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
652 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
653 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
654 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
656 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
657 FIGURE B-19
659 APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
661 APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION DELETED
APPENDIX E MANUFACTURED HOUSING USED AS DWELLINGS DELETED
APPENDIX F PASSIVE RADON GAS CONTROLS DELETED
APPENDIX G PIPING STANDARDS FOR VARIOUS APPLICATIONS DELETED
663 APPENDIX H PATIO COVERS
SECTION AH101 GENERAL
SECTION AH102 DEFINITION
SECTION AH103 EXTERIOR WALLS AND OPENINGS
SECTION AH104 HEIGHT
SECTION AH105 STRUCTURAL PROVISIONS
SECTION AH106 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
664 TABLE AH106.4(1) DESIGN WIND PRESSURES FOR SCREEN ENCLOSURE FRAMINGa, b, e, f, g, h
TABLE AH106.4(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE
665 FIGURE AH106.4.1 ULTIMATE DESIGN WIND SPEEDS FOR PATIO COVERS AND SCREEN ENCLOSURES
667 APPENDIX I PRIVATE SEWAGE DISPOSAL DELETED
APPENDIX J EXISTING BUILDINGS AND STRUCTURES DELETED
669 APPENDIX K SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIR-BORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
671 APPENDIX L PERMIT FEES DELETED
APPENDIX M HOME DAY CARE—R-3 OCCUPANCY DELETED
APPENDIX N VENTING METHODS DELETED
APPENDIX O AUTOMATIC VEHICULAR GATES DELETED
APPENDIX P SIZING OF WATER PIPING SYSTEM DELETED
APPENDIX Q DELETED
673 APPENDIX R LIGHT STRAW-CLAY CONSTRUCTION
SECTION AR101 GENERAL
SECTION AR102 DEFINITIONS
SECTION AR103 NONBEARING LIGHT STRAW-CLAY CONSTRUCTION
674 SECTION AR104 THERMAL INSULATION
SECTION AR105 REFERENCED STANDARD
675 APPENDIX S STRAWBALE CONSTRUCTION
SECTION AS101 GENERAL
SECTION AS102 DEFINITIONS
SECTION AS103 BALES
676 SECTION AS104 FINISHES
677 SECTION AS105 STRAWBALE WALLS—GENERAL
678 TABLE AS105.4 OUT-OF-PLANE RESISTANCE AND UNRESTRAINED WALL DIMENSIONS
679 SECTION AS106 STRAWBALE WALLS—STRUCTURAL
TABLE AS106.6.1 MINIMUM COMPRESSIVE STRENGTH FOR PLASTERS ON STRUCTURAL WALLS
680 TABLE AS106.12 ALLOWABLE SUPERIMPOSED VERTICAL LOADS (LBS/FOOT) FOR PLASTERED LOAD-BEARING STRAWBALE WALLS
TABLE AS106.13(1) PLASTERED STRAWBALE BRACED WALL PANEL TYPES
681 TABLE AS106.13(2) BRACING REQUIREMENTS FOR STRAWBALE BRACED WALL PANELS BASED ON WIND SPEED
SECTION AS107 FIRE RESISTANCE
682 TABLE AS106.13(3) BRACING REQUIREMENTS FOR STRAWBALE BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY
683 SECTION AS108 THERMAL INSULATION
SECTION AS109 REFERENCED STANDARDS
685 APPENDIX T RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER N1102.4 OR N1105 CONDITIONS ≤ 5ACH50 DELETED
APPENDIX U SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS, MULTIPLE SINGLE FAMILYDWELLINGS (TOWNHOUSES) DELETED
687 INDEX
697 VALUABLE GUIDES TO CHANGES IN THE 2015 I-CODES®
698 2015 I-CODE ESSENTIALS
NJ ResidentialCode 2015
$63.92