NY MechanicalCode 07 2007
$37.65
Mechanical Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2007 | 124 |
Based on the 2003 International Mechanical Code®. The Mechanical Code establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions. It is founded on broad-based principles that make possible the use of new materials and new mechanical designs.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | MECHANICAL CODE OF NEW YORK STATE 2007 |
2 | COPYRIGHT |
3 | ACKNOWLEDGMENTS |
5 | TABLE OF CONTENTS |
9 | CHAPTER 1 GENERAL REQUIREMENTS SECTION 101 TITLE, SCOPE AND PURPOSE SECTION 102 APPLICABILITY SECTION 103 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION |
10 | SECTION 104 SERVICE UTILITIES SECTION 105 ADMINISTRATION AND ENFORCEMENT |
11 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
23 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL |
24 | SECTION 302 PROTECTION OF STRUCTURE |
26 | SECTION 303 EQUIPMENT AND APPLIANCE LOCATION |
27 | SECTION 304 INSTALLATION |
28 | SECTION 305 PIPING SUPPORT TABLE 305.4 PIPING SUPPORT SPACINGa SECTION 306 ACCESS AND SERVICE SPACE |
29 | SECTION 307 CONDENSATE DISPOSAL |
30 | SECTION 308 CLEARANCE REDUCTION |
31 | TABLE 308.6 CLEARANCE REDUCTION METHODS [B] SECTION 309 TEMPERATURE CONTROL [F] SECTION 310 EXPLOSION CONTROL |
32 | [F] SECTION 311 SMOKE AND HEAT VENTS SECTION 312 HEATING AND COOLING LOAD CALCULATIONS |
33 | CHAPTER 4 VENTILATION SECTION 401 GENERAL TABLE 401.6 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS [B] SECTION 402 NATURAL VENTILATION |
34 | SECTION 403 MECHANICAL VENTILATION (EQUATION 4-1) |
35 | TABLE 403.3 REQUIRED OUTDOOR VENTILATION AIR TABLE 403.3—continued REQUIRED OUTDOOR VENTILATION AIR |
36 | TABLE 403.3—continued REQUIRED OUTDOOR VENTILATION AIR SECTION 404 ENCLOSED PARKING GARAGES SECTION 405 SYSTEMS CONTROL SECTION 406 VENTILATION OF UNINHABITED SPACES |
37 | CHAPTER 5 EXHAUST SYSTEMS SECTION 501 GENERAL SECTION 502 REQUIRED SYSTEMS |
43 | SECTION 503 MOTORS AND FANS |
44 | SECTION 504 CLOTHES DRYER EXHAUST SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT |
45 | SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT |
48 | SECTION 507 COMMERCIAL KITCHEN HOODS |
49 | TABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE |
50 | SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR SECTION 509 FIRE SUPPRESSION SYSTEMS SECTION 510 HAZARDOUS EXHAUST SYSTEMS |
52 | TABLE 510.8 MINIMUM DUCT THICKNESS TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS |
53 | SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS SECTION 513 SMOKE CONTROL SYSTEMS |
55 | (EQUATION 5-2) (EQUATION 5-3) (EQUATION 5-4) (EQUATION 5-5) |
56 | (EQUATION5-6) (EQUATION 5-7) (EQUATION 5-8) (EQUATION 5-9) (EQUATION 5-10) |
58 | SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS |
59 | CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL SECTION 602 PLENUMS |
60 | SECTION 603 DUCT CONSTRUCTION AND INSTALLATION TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS |
61 | SECTION 604 INSULATION |
62 | SECTION 605 AIR FILTERS SECTION 606 SMOKE DETECTION SYSTEMS CONTROL |
63 | [B] SECTION 607 DUCTS AND AIR TRANSFER OPENINGS TABLE 607.3.1 FIRE DAMPER RATING |
67 | CHAPTER 7 COMBUSTION AIR SECTION 701 GENERAL SECTION 702 INSIDE AIR FIGURE 702.3 ALL AIR FROM INSIDE THE BUILDING |
68 | SECTION 703 OUTDOOR AIR SECTION 704 COMBINED USE OF INSIDE AND OUTDOOR AIR( CONDITION 1) FIGURE 703.1.1 ALL AIR FROM OUTDOORS – INLET AIR FROM VENTILATED CRAWL SPACE FIGURE 703.1.2 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC FIGURE 703.1.3 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS |
69 | SECTION 705 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2) SECTION 706 FORCED COMBUSTION AIR SUPPLY SECTION 707 DIRECT CONNECTION SECTION 708 COMBUSTION AIR DUCTS |
70 | SECTION 709 LOUVERS AND GRILLS SECTION 710 OPENING LOCATION AND PROTECTION |
71 | CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL |
72 | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION |
73 | SECTION 803 CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES |
74 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FORDOMESTIC HEATING APPLIANCESa,b,c,d TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS |
75 | FIGURE 803.10.6 CHIMNEY CONNECTOR SYSTEMS (continued) |
76 | FIGURE 803.10.6—continued CHIMNEY CONNECTOR SYSTEMS |
77 | SECTION 805 FACTORY-BUILT CHIMNEYS SECTION 806 METAL CHIMNEYS |
79 | CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE (WOOD) STOVES ANDROOM HEATERS SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES SECTION 907 INCINERATORS AND CREMATORIES |
80 | SECTION 908 COOLING TOWERS, EVAPORATIVECONDENSERS AND FLUID COOLERS SECTION 909 VENTED WALL FURNACES SECTION 910 FLOOR FURNACES SECTION 911 DUCT FURNACES |
81 | SECTION 912 INFRARED RADIANT HEATERS SECTION 913 CLOTHES DRYERS SECTION 914 SAUNA HEATERS SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES SECTION 916 POOL AND SPA HEATERS SECTION 917 COOKING APPLIANCES |
82 | SECTION 918 FORCED-AIR WARM-AIR FURNACES SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS |
83 | SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS SECTION 924 STATIONARY FUEL CELL POWER PLANTS SECTION 925 MASONRY HEATERS |
85 | CHAPTER 10 BOILERS,WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL SECTION 1002 WATER HEATERS SECTION 1003 PRESSURE VESSELS SECTION 1004 BOILERS |
86 | SECTION 1005 BOILER CONNECTIONS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS SECTION 1007 BOILER LOW-WATER CUTOFF |
87 | SECTION 1008 STEAM BLOWOFF VALVE SECTION 1009 HOT WATER BOILER EXPANSION TANK (EQUATION 10-1) SECTION 1010 GAUGES SECTION 1011 TESTS |
89 | CHAPTER 11 REFRIGERATION SECTION 1101 GENERAL SECTION 1102 SYSTEM REQUIREMENTS |
90 | SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION SECTION 1104 SYSTEM APPLICATION REQUIREMENTS |
91 | [F] TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA |
92 | [F] TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA |
93 | [F] TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA |
94 | TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS |
95 | SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS (EQUATION 11-1) |
96 | (EQUATION 11-2) SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS SECTION 1107 REFRIGERANT PIPING |
97 | SECTION 1108 FIELD TEST |
98 | [F]SECTION 1109 PERIODIC TESTING |
99 | CHAPTER 12 HYDRONIC PIPING SECTION 1201 GENERAL SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE TABLE 1202.4—continued HYDRONIC PIPE TABLE 1202.5 HYDRONIC PIPE FITTINGS SECTION 1203 JOINTS AND CONNECTIONS |
101 | SECTION 1204 PIPE INSULATION SECTION 1205 VALVES SECTION 1206 PIPING INSTALLATION |
102 | SECTION 1207 TRANSFER FLUID SECTION 1208 TESTS SECTION 1209 EMBEDDED PIPING |
103 | CHAPTER 13 FUEL OIL PIPING AND STORAGE SECTION 1301 GENERAL SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING SECTION 1303 JOINTS AND CONNECTIONS |
104 | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION |
105 | SECTION 1306 OIL GAUGING SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING |
107 | CHAPTER 14 SOLAR SYSTEMS SECTION 1401 GENERAL SECTION 1402 INSTALLATION |
108 | SECTION 1403 HEAT TRANSFER FLUIDS SECTION 1404 MATERIALS |
109 | CHAPTER 15 REFERENCED STANDARDS ACCA ANSI ARI ASHRAE ASME |
110 | ASTM |
111 | AWS CSA |
112 | DOL IIAR MSS NAIMA NFPA |
113 | SMACNA UL |
115 | APPENDIX A RESERVED |
117 | APPENDIX B RESERVED |
119 | APPENDIX C STRUCTURAL SAFETY BORED HOLES IN JOISTS NOTCHES AT ENDS OF JOISTS |
120 | BORING OF BEARING STUDS |
121 | INDEX |