Shopping Cart

No products in the cart.

NY NYC MechanicalCode 2022 1stptg

$59.58

New York City Mechanical Code

Published By Publication Date Number of Pages
NY 2022
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2015 International Mechanical Code. Effective date: November 7, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY MECHANICAL CODE
2 2022 NEW YORK CITY MECHANICAL CODE TITLE PAGE
3 COPYRIGHT
4 DEDICATION
6 NEW YORK CITY CONSTRUCTION CODES PREFACE
8 ACKNOWLEDGEMENTS
16 TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
18 TITLE 28 NEW YORK CITY CONSTRUCTION CODES
20 TABLE OF CONTENTS
24 CHAPTER 1 ADMINISTRATION
SECTION MC 101 GENERAL
SECTION MC 102 APPLICABILITY
25 SECTION MC 103 DEPARTMENT OF BUILDINGS
SECTION MC 104 DUTIES AND POWERS OF THE COMMISSIONER OF BUILDINGS
SECTION MC 105 APPROVALS
SECTION MC 106 PERMITS
SECTION MC 107 CONSTRUCTION DOCUMENTS
27 SECTION MC 108 INSPECTIONS AND TESTING
28 SECTION MC 109 VIOLATIONS
30 CHAPTER 2 DEFINITIONS
SECTION MC 201 GENERAL
31 SECTION MC 202 GENERAL DEFINITIONS
44 CHAPTER 3 GENERAL REGULATIONS
SECTION MC 301 GENERAL
45 SECTION MC 302 STRUCTURAL SAFETY
46 SECTION MC 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION MC 304 INSTALLATION
47 SECTION MC 305 PIPING SUPPORT
48 TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION MC 306 ACCESS AND SERVICE SPACE
50 SECTION MC 307 CONDENSATE DISPOSAL
51 TABLE 307.2.2 CONDENSATE DRAIN SIZING
SECTION MC 308 CLEARANCE REDUCTION
52 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
53 SECTION MC 309 TEMPERATURE CONTROL
SECTION MC 310 EXPLOSION CONTROL
SECTION MC 311 SMOKE AND HEAT VENTS
SECTION MC 312 HEATING AND COOLING LOAD CALCULATIONS
SECTION MC 313 NOISE CONTROL AND VIBRATION ISOLATION REQUIREMENTS
56 CHAPTER 4 VENTILATION
SECTION MC 401 GENERAL
57 TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
SECTION MC 402 NATURAL VENTILATION
SECTION MC 403 MECHANICAL VENTILATION
58 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
59 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
60 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
61 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
62 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
63 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
64 TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9
65 SECTION MC 404 ENCLOSED PARKING GARAGES
SECTION MC 405 SYSTEMS CONTROL
SECTION MC 406 VENTILATION OF UNINHABITED SPACES
SECTION MC 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
SECTION MC 408 VENTILATION OF NONPRODUCTION CHEMICAL LABORATORIES
66 CHAPTER 5 EXHAUST SYSTEMS
SECTION MC 501 GENERAL
67 SECTION MC 502 REQUIRED SYSTEMS
68 EQUATION 5-1
75 SECTION MC 503 MOTORS AND FANS
SECTION MC 504 CLOTHES DRYER EXHAUST
76 TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
77 SECTION MC 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION MC 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
83 SECTION MC 507 COMMERCIAL KITCHEN HOODS
85 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
86 SECTION MC 508 COMMERCIAL KITCHEN MAKEUP AIR
87 SECTION MC 509 FIRE SUPPRESSION SYSTEMS
SECTION MC 510 HAZARDOUS EXHAUST SYSTEMS
89 TABLE 510.9 MINIMUM DUCT THICKNESS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
SECTION MC 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
90 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL DUST, STOCK AND REFUSE CONVEYING SYSTEMS
SECTION MC 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION MC 513 SMOKE CONTROL SYSTEMS
91 SECTION MC 514 ENERGY RECOVERY VENTILATION SYSTEMS
SECTION MC 515 POSTFIRE SMOKE PURGE SYSTEMS
92 CHAPTER 6 DUCT SYSTEMS
SECTION MC 601 GENERAL
93 SECTION MC 602 PLENUMS
94 SECTION MC 603 DUCT CONSTRUCTION AND INSTALLATION
95 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
97 SECTION MC 604 INSULATION
98 SECTION MC 605 AIR FILTERS
SECTION MC 606 SMOKE DETECTION SYSTEMS CONTROL
99 SECTION MC 607 DUCTS AND AIR TRANSFER OPENINGS
100 TABLE 607.3.2.1 FIRE DAMPER RATING
106 SECTION MC 608 AIR OUTLETS AND AIR INLETS
SECTION MC 609 SERVICE OPENINGS
108 CHAPTER 7 COMBUSTION, VENTILATION, AND DILUTION AIR
SECTION MC 701 GENERAL
SECTION MC 702 INSIDE AIR
109 SECTION MC 703 OUTDOOR AIR
SECTION MC 704 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 1)
110 SECTION MC 705 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2)
SECTION MC 706 MECHANICAL COMBUSTION AIR SUPPLY
SECTION MC 707 DIRECT CONNECTION
SECTION MC 708 COMBUSTION AIR DUCTS
SECTION MC 709 OPENING OBSTRUCTIONS
111 SECTION MC 710 OPENING LOCATION AND PROTECTION
112 CHAPTER 8 CHIMNEYS AND VENTS
SECTION MC 801 GENERAL
116 EQUATION 8-1
TABLE 801.21 “F” FACTOR FOR DETERMINING CHIMNEY DISTANCES
SECTION MC 802 VENTS
117 TABLE 802.2 VENT APPLICATION
SECTION MC 803 CONNECTORS
TABLE 803.8 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
118 TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
119 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION MC 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
121 SECTION MC 805 FACTORY-BUILT CHIMNEYS
SECTION MC 806 METAL CHIMNEYS
SECTION MC 807 CHANGES IN APPLIANCE FUELS
SECTION MC 808 REDUCTION OF FLUE SIZE
SECTION MC 809 CHIMNEY SUPPORTED FROM EQUIPMENT
SECTION MC 810 TEST RUN AND SMOKE TEST
122 SECTION MC 811 EXHAUST GASES FROM INTERNAL COMBUSTION ENGINES AND TURBINES
124 CHAPTER 9 SPECIFIC APPLIANCES AND EQUIPMENT
SECTION MC 901 GENERAL
SECTION MC 902 MASONRY FIREPLACES
SECTION MC 903 FACTORY-BUILT FIREPLACES
SECTION MC 904 PELLET FUEL-BURNING APPLIANCES
SECTION MC 905 FIREPLACE STOVES AND ROOM HEATERS
125 SECTION MC 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION MC 907 INCINERATORS AND CREMATORIES
SECTION MC 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
126 SECTION MC 909 VENTED WALL FURNACES
SECTION MC 910 FLOOR FURNACES
127 SECTION MC 911 DUCT FURNACES AND HEATERS
SECTION MC 912 INFRARED RADIANT HEATERS
SECTION MC 913 CLOTHES DRYERS
SECTION MC 914 SAUNA HEATERS
128 SECTION MC 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION MC 916 POOL AND SPA HEATERS
SECTION MC 917 COOKING APPLIANCES
SECTION MC 918 FORCED-AIR WARM-AIR FURNACES
SECTION MC 919 CONVERSION BURNERS
SECTION MC 920 UNIT HEATERS
129 SECTION MC 921 VENTED ROOM HEATERS
SECTION MC 922 KEROSENE AND OIL-FIRED STOVES
SECTION MC 923 CERAMIC KILNS
SECTION MC 924 STATIONARY FUEL CELL POWER PLANTS
SECTION MC 925 MASONRY HEATERS
SECTION MC 926 GASEOUS HYDROGEN SYSTEMS
SECTION MC 927 ELECTRIC RADIANT HEATING SYSTEMS
SECTION MC 928 EVAPORATIVE COOLERS
132 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION MC 1001 GENERAL
SECTION MC 1002 WATER HEATERS
SECTION MC 1003 PRESSURE VESSELS
133 SECTION MC 1004 BOILERS
TABLE 1004.3.1 BOILER TOP CLEARANCES
134 SECTION MC 1005 BOILER CONNECTIONS
SECTION MC 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
135 SECTION MC 1007 BOILER LOW-WATER CUTOFF
SECTION MC 1008 BOILER BLOWOFF/BLOWDOWN VALVES
SECTION MC 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
136 TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
SECTION MC 1010 GAUGES
SECTION MC 1011 TESTS
137 SECTION MC 1012 MAXIMUM TEMPERATURE
138 CHAPTER 11 REFRIGERATION
SECTION MC 1101 GENERAL
SECTION MC 1102 SYSTEM REQUIREMENTS
139 SECTION MC 1103 REFRIGERATION SYSTEM CLASSIFICATION
TABLE 1103.1 REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
140 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
141 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
142 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
143 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
SECTION MC 1104 SYSTEM APPLICATION REQUIREMENTS
145 TABLE 1104.3.1 SPECIAL QUANTITY LIMITS FOR SEALED AMMONIA/WATER ABSORPTION AND SELF-CONTAINED SYSTEMS
SECTION MC 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
146 EQUATION 11-1
EQUATION 11-2
147 SECTION MC 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
148 SECTION MC 1107 REFRIGERANT PIPING
150 SECTION MC 1108 FIELD TEST
151 SECTION MC 1109 PERIODIC TESTING
152 CHAPTER 12 HYDRONIC PIPING
SECTION MC 1201 GENERAL
SECTION MC 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4 HYDRONIC PIPE—continued
TABLE 1202.5 HYDRONIC PIPE FITTINGS
153 SECTION MC 1203 JOINTS AND CONNECTIONS
154 SECTION MC 1204 PIPE INSULATION
155 SECTION MC 1205 VALVES
SECTION MC 1206 PIPING INSTALLATION
SECTION MC 1207 TRANSFER FLUID
SECTION MC 1208 TESTS
156 SECTION MC 1209 EMBEDDED PIPING
SECTION MC 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
158 SECTION MC 1211 HIGH-PRESSURE STEAM AND HIGH TEMPERATURE HOT WATER PIPING SYSTEMS
162 CHAPTER 13 FUEL-OIL PIPING AND STORAGE
SECTION MC 1301 GENERAL
SECTION MC 1302 MATERIAL
TABLE 1302.3 FUEL-OIL PIPING
163 TABLE 1302.5 PIPE FITTINGS
SECTION MC 1303 JOINTS AND CONNECTIONS
164 SECTION MC 1304 PIPING SUPPORT
SECTION MC 1305 FUEL-OIL SYSTEM INSTALLATION
166 TABLE 1305.7(1) VENT PIPING FOR UNDERGROUND TANKS
TABLE 1305.7(2) NORMAL VENT PIPING FOR TANKS INSTALLED INSIDE BUILDINGS
172 EQUATION 13-1
173 EQUATION 13-2
174 SECTION MC 1306 OIL GAUGING
SECTION MC 1307 FUEL-OIL VALVES
175 SECTION MC 1308 TESTING
176 CHAPTER 14 SOLAR SYSTEMS
SECTION MC 1401 GENERAL
SECTION MC 1402 INSTALLATION
177 SECTION MC 1403 HEAT TRANSFER FLUIDS
SECTION MC 1404 MATERIALS
178 CHAPTER 15 REFERENCED STANDARDS
SECTION MC 1501 GENERAL
SECTION MC 1502 STANDARDS
ACCA
AHRI
AMCA
179 ANSI
ASHRAE
ASME
180 ASNT
ASSE
ASTM
182 AWS
AWWA
183 BSI
CAN/ULC
CSA
184 DOL
EN
IIAR
MSS
NAIMA
185 NBBI
NFPA
NSF
186 SMACNA
UL
188 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
189 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
190 APPENDIX B RESERVED
192 APPENDIX C FUEL OIL STORAGE TANK VENTING OPTIONS
SECTION MC C101 GENERAL
FIGURE C101.1(1) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK
193 FIGURE C101.1(2) PRIMARY TANK: UL 142 OR DUAL LABEL TANK DAY TANK: UL 142 OR DUAL LABEL TANK
194 FIGURE C101.1(3) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 142 OR DUAL LABEL TANK
196 INDEX RESERVED
198 ICC DIGITAL CODES PREMIUM
199 ICC ASSESSMENT CENTER
200 ICC LEARNING CENTER
201 ICC EVALUATION SERVICE
NY NYC MechanicalCode 2022 1stptg
$59.58