Shopping Cart

No products in the cart.

NY ResidentialCode 07 2007

$43.06

Residential Code of New York State

Published By Publication Date Number of Pages
NY 2007 604
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Based on the 2003 International Residential Code®, This code has been updated to reflect the latest technological advances in building design and construction. This code also contains plumbing, mechanical and fuel gas provisions that coordinate with the Plumbing Code, Mechanical Code and Fuel Gas Code.

PDF Catalog

PDF Pages PDF Title
1 RESIDENTIAL CODE OF NEW YORK STATE 2007
2 COPYRIGHT © 2007
3 ACKNOWLEDGMENTS
5 TABLE OF CONTENTS
13 PART I — ADMINISTRATIVE
CHAPTER 1 GENERAL REQUIREMENTS
SECTION R101 TITLE, SCOPE AND PURPOSE
SECTION R102 APPLICABILITY
SECTION R103 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION
14 SECTION R104 SERVICE UTILITIES
SECTION R105 ADMINISTRATION AND ENFORCEMENT
15 PART II – DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
35 PART III – BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R301 DESIGN CRITERIA
36 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
37 FIGURE R301.2(1) COMPONENT AND CLADDING PRESSURE ZONES
38 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf)
39 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa,b,c
40 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES – SITE CLASS D
41 FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE
42 FIGURE R301.2(4) BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
43 FIGURE R301.2(5) GROUND SNOW LOADS, Pg FOR NEW YORK STATE
44 FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP
45 FIGURE R301.2(7) DECAY PROBABILITY MAP
46 TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa
TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
47 TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa
49 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.7ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa,b,c
50 SECTION R302 LOCATION ON LOT
SECTION R303 LIGHT, VENTILATION AND HEATING
51 SECTION R304 MINIMUM ROOM AREAS
SECTION R305 CEILING HEIGHT
52 SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
FIGURE R307.2 MINIMUM FIXTURE CLEARANCES
53 SECTION R308 GLAZING
TABLE R308.3 MINIMUM CATEGORY CLASSIFICATION OF GLAZING
55 SECTION R309 GARAGES AND CARPORTS
SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
56 SECTION R311 MEANS OF EGRESS
58 SECTION R312 GUARDS
SECTION R313 SMOKE ALARMS, AUTOMATIC SPRINKLER SYSTEMS AND CARBON MONOXIDE ALARMS
59 SECTION R314 FOAM PLASTIC
60 [B] SECTION R315 FLAME SPREAD AND SMOKE DENSITY
[B] SECTION R316 INSULATION
61 SECTION R317 DWELLING UNIT SEPARATION
62 SECTION R318 MOISTURE VAPOR RETARDERS
SECTION R319 PROTECTION AGAINST DECAY
63 SECTION R320 PROTECTION AGAINST TERMITES
64 [F] SECTION R321 SITE ADDRESS
[B] SECTION R322 ACCESSIBILITY
SECTION R323 FLOOD-RESISTANT CONSTRUCTION
67 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD–BEARING VALUES OF FOUNDATION MATERIALSa
SECTION R402 MATERIALS
68 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
TABLE R403.1 MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS (inches)a
69 FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS
70 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
71 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
72 FIGURE R403.1.5 STEPPED FOOTING
73 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
75 FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
SECTION R404 FOUNDATION WALLS
76 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
77 TABLE R403.3 MINIMUM INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
78 TABLE R403.3(1) AIR FREEZING INDEX (BASE 32 FAHRENHEIT) RETURN PERIOD OF 100 YEAR (99% probability)
79 FIGURE R403.3(4)INSULATION PLACEMENT FOR FROST-PROTECTEDFOOTINGS ADJACENT TO HEATED STRUCTURE
80 TABLE R404.1.1(1) PLAIN CONCRETE AND PLAIN MASONRY FOUNDATION WALLS
81 TABLE R404.1.1(2) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS
TABLE R404.1.1(3) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS
82 TABLE R404.1.1(4) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS
83 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
84 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
85 TABLE R404.4(1) 5.5-INCH THICK FLAT ICF FOUNDATION WALLSa,b,c,d
86 TABLE R404.4(2) 7.5-INCH THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e
TABLE R404.4(3) 9.5-INCH THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e
87 TABLE R404.4(4) WAFFLE GRID ICF FOUNDATION WALLSa, b, c, d, e
88 TABLE R404.4(5)SCREEN-GRID ICF FOUNDATION WALLSa, b c, d, e
89 SECTION R405 FOUNDATION DRAINAGE
SECTION R406 FOUNDATION WATERPROOFINGAND DAMPPROOFING
90 TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
SECTION R407 COLUMNS
91 SECTION R408 UNDER-FLOOR SPACE
93 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
94 FIGURE R502.2 FLOOR CONSTRUCTION
95 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
96 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
97 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load 40 psf, Roof Live Load 20 psf)
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f
98 TABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and North American spruce-pine-firb and required number of jack studs)
100 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
101 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
102 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa,b,c
103 TABLE 503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND)
SECTION R505 STEEL FLOOR FRAMING
104 TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES
TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
FIGURE R505.2(1) C-SECTION
FIGURE R505.2(2) TRACK SECTION
105 FIGURE R505.2(3) FLOOR JOIST WEB HOLES
TABLE R505.2(3) MAXIMUM HOLE DIMENSIONS AND SPACING IN JOIST WEBS
106 TABLE R505.2.4 SCREW SUBSTITUTION FACTOR
FIGURE R505.3 STEEL FLOOR CONSTRUCTION
107 FIGURE R505.3—continued STEEL FLOOR CONSTRUCTION
108 TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS a,b
TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(1) FLOOR TO LOAD-BEARING WALL STUD CONNECTION
109 FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION
110 FIGURE R505.3.1(4) FLOOR CANTILEVER TO LOAD-BEARING WALL CONNECTION
FIGURE R505.3.1(5) FLOOR CANTILEVER TO WOOD SILL CONNECTION
111 FIGURE R505.3.1(6) FLOOR CANTILEVER TO FOUNDATION CONNECTION
FIGURE R505.3.1(7) CONTINUOUS JOIST SPAN SUPPORTED ON STUD
112 TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTSa,b
113 FIGURE R505.3.4BEARING STIFFENER
114 FIGURE R505.3.6 HOLE PATCH
FIGURE R505.3.8TRACK SPLICE
115 SECTION R506 CONCRETE FLOORS (ON GROUND)
117 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
118 TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
119 TABLE R602.3(1)—continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
120 TABLE R602.3(2) ALTERNATE ATTACHMENTS
121 TABLE R602.3(3) ALLOWABLE STUD SPACING FOR WOOD STRUCTURAL PANEL WALL SHEATHING
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa
TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
122 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
123 FIGURE R602.3(2) FRAMING DETAILS
124 TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C and D1b,c
125 TABLE R602.3.1—continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C and D1
126 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
127 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
128 FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
129 TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
131 TABLE R602.10.1 WALL BRACING
132 TABLE R602.10.5 LENGTH REQUIREMENTS FOR BRACED WALL PANELS IN A CONTINUOUSLY SHEATHED WALLa,b
FIGURE R602.10.5 EXTERIOR CORNER FRAMING
134 TABLE R602.10.11 ADJUSTMENT OF BRACING AMOUNTS FOR INTERIOR BRACED WALL LINES ACCORDING TO BRACED WALL LINE SPACINGa,b
SECTION R603 STEEL WALL FRAMING
135 FIGURE R602.11.3STEPPED FOUNDATION CONSTRUCTION
136 TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES
TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL STUDS
137 FIGURE R603.2(1) C-SECTION
FIGURE R603.2(2) TRACK-SECTION
138 FIGURE R603.2(3) WEB HOLES
FIGURE R603.3 STEEL WALL CONSTRUCTION
139 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b,c
FIGURE R603.3.1(1) WALL TO FOUNDATION CONNECTION
140 FIGURE R603.3.1(2) WALL TO WOOD SILL CONNECTION
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
141 TABLE R603.3.2(2) COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 33 ksi steel
142 TABLE R603.3.2(3) COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 33 ksi steel
143 TABLE R603.3.2(4) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 33 ksi steel
144 TABLE R603.3.2(5) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 33 ksi steel
145 TABLE R603.3.2(6) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 33 ksi steel
146 TABLE R603.3.2(7) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 33 ksi steel
147 TABLE R603.3.2(8) COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 50 ksi steel
148 TABLE R603.3.2(9)COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLSStuds supporting one floor, roof and ceiling (first story of a two-story building) 50 ksi steel
149 TABLE R603.3.2(10) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 50 ksi steel
150 TABLE R603.3.2(11) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 50 ksi steel
151 TABLE R603.3.2(12) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 50 ksi steel
152 TABLE R603.3.2(13) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 50 ksi steel
153 TABLE R603.2.4 SCREW SUBSTITUTION FACTOR
154 FIGURE R603.3.5 HOLE PATCH
FIGURE R603.3.6 TRACK SPLICE
155 FIGURE R603.4 CORNER FRAMING
156 TABLE R603.6(1) ALLOWABLE HEADER SPANSa,b Headers supporting roof and ceiling only (33 ksi steel
157 TABLE R603.6(2) ALLOWABLE HEADER SPANSa,b Headers supporting one floor, roof and ceiling (33 ksi steel)
158 TABLE R603.6(3) ALLOWABLE HEADER SPANSa,b,c Headers supporting one floor, roof and ceiling first story of a two-story building with center load bearing beam (33 ksi steel)
159 TABLE R603.6(4) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.6(5) HEADER TO KING STUD CONNECTION REQUIREMENTSa,b,c,d
TABLE R603.7 MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b,c,d,e
160 FIGURE R603.6HEADER DETAIL
161 SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
SECTION R606 GENERAL MASONRY CONSTRUCTION
162 TABLE R606.4 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
163 TABLE R606.8 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
164 FIGURE R606.10(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
165 FIGURE R606.10(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
166 FIGURE R606.10(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D1 OR D2
167 TABLE R606.11.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D1
168 TABLE R606.11.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.11.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
169 TABLE R606.14.1MINIMUM CORROSION PROTECTION
SECTION R607 UNIT MASONRY
TABLE R607.1 MORTAR PROPORTIONSa,b
170 SECTION R608 MULTIPLE WYTHE MASONRY
171 SECTION R609 GROUTED MASONRY
TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
172 FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
173 SECTION R610 GLASS UNIT MASONRY
174 SECTION R611 INSULATING CONCRETE FORMWALL CONSTRUCTION
TABLE R611.2 REQUIREMENTS FOR ICF WALLSa,b,c
FIGURE R611.3 FLAT ICF WALL SYSTEM
175 TABLE R611.3(1) DESIGN WIND PRESSURE FOR USE WITH TABLES R611.3(2), R611.4(1), AND R611.5 FOR ABOVE GRADE WALLSa
176 TABLE R611.3(2) MINIMUM VERTICAL WALL REINFORCEMENT FOR FLAT ICF ABOVE-GRADE WALLSa,b,c,d
177 FIGURE R611.4 WAFFLE-GRID ICF WALL SYSTEM
178 TABLE R611.4(1) MINIMUM VERTICAL WALL REINFORCEMENT FOR WAFFLE-GRID ICF ABOVE-GRADE WALLSa, b, c
TABLE R611.4(2) DIMENSIONAL REQUIREMENTS FOR CORES AND WEBS INWAFFLE-GRID AND SCREEN-GRID ICF WALLSa,b
179 TABLE R611.5 MINIMUM VERTICAL WALL REINFORCEMENT FOR SCREEN-GRID ICF ABOVE-GRADE WALLSa,b,c
FIGURE R611.5 SCREEN-GRID IFC WALL SYSTEM
180 TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS
181 TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa,b,c,d,f NO. 4 BOTTOM BAR SIZE
182 TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa,b,c,d,f NO. 5 BOTTOM BAR SIZE
183 TABLE R611.7(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d,f NO. 4 BOTTOM BAR SIZE
184 TABLE R611.7(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d,f NO. 5 BOTTOM BAR SIZE
185 TABLE R611.7(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa,b,c,d,e,f,g NO. 4 BOTTOM BAR SIZE
TABLE R611.7(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa,b,c,d,e,f,g NO. 5 BOTTOM BAR SIZE
186 TABLE R611.7(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS WITHOUT STIRRUPS IN LOAD-BEARING WALLSa,b,c,d,e,f,g,h (NO. 4 OR NO. 5) BOTTOM BAR SIZE
187 TABLE R611.7(9) MINIMUM BOTTOM BAR ICF LINTEL REINFORCEMENT FOR LARGE CLEAR SPANS IN LOAD-BEARING WALLSa,b,c,d,e,f,h
188 TABLE R611.7(9A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c
189 TABLE R611.7(9B) MINIMUM SOLID SIDEWALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PARALLEL TO RIDGE) a, b, c, d
190 TABLE R611.7(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS IN NON-LOAD-BEARING WALLS WITHOUT STIRRUPSa, b, c, d NO. 4 BOTTOM BAR
191 TABLE R611.7(10A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c
192 TABLE R611.7(10A)—continued MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c
TABLE R611.7(10B) MINIMUM SOLID SIDE WALL LENGTH REQUIREMENTS FOR 6-INCH WAFFLE AND SCREEN-GRID ICF WALLS (WIND PARALLEL TO RIDGE)a,b,c,d
193 TABLE R611.7(11) MINIMUM PERCENTAGE OF SOLID WALL LENGTH ALONG EXTERIOR WALL LINES FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY Da,b
FIGURE R611.7(1) ICF WALL CONSTRUCTION
194 FIGURE R611.7(2) REINFORCEMENT OF OPENINGS
FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN-GRID WALLS
195 FIGURE R611.7(4) SINGLE FORM HEIGHT WAFFLE-GRID LINTEL
FIGURE R611.7(5) DOUBLE FORM HEIGHT WAFFLE-GRID LINTEL
196 FIGURE R611.7(6) SINGLE FORM HEIGHT SCREEN-GRID LINTEL
FIGURE R611.7(7) DOUBLE FORM HEIGHT SCREEN-GRID LINTEL
197 FIGURE R611.7.1.4 LAP SPLICES
198 FIGURE R611.7.4 MINIMUM SOLID WALL LENGTH
199 TABLE R611.7.4 WIND VELOCITY PRESSURE FOR DETERMINATION OF MINIMUM SOLID WALL LENGTHa
200 TABLE R611.8(1) FLOOR LEDGER-ICF WALL CONNECTION (SIDE-BEARING CONNECTION) REQUIREMENTSa,b,c
TABLE R611.8(2) DESIGN VALUES (PLF) FOR FLOOR JOIST-TO-WALL ANCHORS REQUIRED FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY Da,b
201 FIGURE R611.8(1) SECTION CUT THROUGH FLAT WALL OR VERTICAL CORE OF WAFFLE- OR SCREEN-GRID WALL
FIGURE R611.8(2) FLOOR LEDGER—ICF WALL CONNECTION (SIDE-BEARING CONNECTION)
202 FIGURE R611.8(3) FLOOR LEDGER—ICF WALL CONNECTION (LEDGE-BEARING CONNECTION)
FIGURE R611.8(4) WOOD FLOOR LEDGER—ICF WALL SYSTEM CONNECTION (THROUGH-BOLT SIDE-BEARING CONNECTION)
203 FIGURE R611.8(5) FLOOR LEDGER—ICF WALL CONNECTION
FIGURE R611.8(6) ANCHORAGE REQUIREMENTS FOR TOP BEARING WALLS FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY D FOR FLOOR FRAMING PARALLEL TO WALL
204 FIGURE R611.8(7) ANCHORAGE REQUIREMENTS FOR LEDGER BEARING WALLS FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY D FOR FLOOR FRAMING PARALLEL TO WALL
205 TABLE R611.9 DESIGN TENSILE STRENGTH OF HEADED BOLTS CAST IN CONCRETEa
FIGURE R611.9ROOF SILL PLATE—ICF WALL CONNECTION
206 SECTION R612 CONVENTIONALLY FORMED CONCRETE WALL CONSTRUCTION
SECTION R613 EXTERIOR WINDOWS AND GLASS DOORS
207 FIGURE R613.5(1) THROUGH THE FRAME
FIGURE R613.5(2) FRAME CLIP
FIGURE R613.5(3) THROUGH THE FRAME
FIGURE R613.5(4) FRAME CLIP
208 FIGURE R613.5(5) THROUGH THE FLANGE
FIGURE R613.5(6) THROUGH THE FRAME
FIGURE R613.5(7) FRAME CLIP
FIGURE R613.5(8) THROUGH THE FLANGE
209 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
210 TABLE R702.1(3) PORTLAND CEMENT PLASTER
211 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
212 SECTION R703 EXTERIOR COVERING
213 TABLE R703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
214 TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa,b,c (Dimensions are in inches)
216 FIGURE R703.7 MASONRY VENEER WALL DETAILS
217 FIGURE R703.7—continued MASONRY VENEER WALL DETAILS
218 FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
219 FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
TABLE R703.7.3 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa,b,c
221 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
224 TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
225 TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
226 TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
227 TABLE R802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
228 TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
229 TABLE R802.5.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
230 TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
231 TABLE R802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
232 TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
233 TABLE R802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
234 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling not attached to rafters, L/Δ = 180)
235 TABLE R802.5.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling not attached to rafters, L/Δ = 180)
236 TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
237 TABLE R802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
238 TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling attached to rafters, L/Δ = 240)
239 TABLE R802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling attached to rafters, L/Δ = 240)
240 TABLE R802.5.1(7) RAFTER SPANS COMMON LUMBER SPECIES (Ground snow load=70 psf or less, ceiling not attached to rafters, L/Δ = 180)
241 TABLE R802.5.1(7)—continued RAFTER SPANS COMMON LUMBER SPECIES(Ground snow load=70 psf or less, ceiling not attached to rafters, L/Δ = 180)
242 TABLE R802.5.1(8) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 70 psf or less, ceiling attached to rafters, L/D=240)
243 TABLE R802.5.1(8) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 70 psf or less, ceiling attached to rafters, L/D=240)
244 TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa,b,c,d,e,f
245 FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION
246 TABLE R802.11REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCESa,b,c,e,f(Pounds per connection)
247 SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
SECTION R804 STEEL ROOF FRAMING
248 TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES
TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL ROOF FRAMING MEMBERS
FIGURE R804.2(1) C-SECTION
FIGURE R804.2(2) TRACK SECTION
FIGURE R804.2(3) WEB HOLES
249 TABLE R804.2.4 SCREW SUBSTITUTION FACTOR
250 TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa,b
FIGURE R804.3 STEEL ROOF CONSTRUCTION
251 TABLE R804.3.1(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL CEILING JOISTSa,b,c 10 psf live load (no attic storage)
TABLE R804.3.1(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL CEILING JOISTSa,b,c 20 psf live load (Limited attic storage where development of future rooms is not possible)
252 TABLE R804.3.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO RAFTER CONNECTIONa
FIGURE R804.3.1(1) JOIST TO RAFTER CONNECTION
253 TABLE R804.3.3(1) ALLOWABLE HORIZONTAL RAFTER SPANSa,b
TABLE R804.3.3(2) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
TABLE R804.3.3.1 NUMBER OF SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR RAFTER TO RIDGE MEMBER CONNECTIONa
254 FIGURE R804.3.3.1 RIDGE BOARD CONNECTION
255 FIGURE R804.3.6 HOLE PATCHING
FIGURE R804.3.7(1) SPLICED CEILING JOISTS
256 FIGURE R804.3.7(2) TRACK SPLICE
FIGURE R804.3.8 BEARING STIFFENER
257 FIGURE R804.3.10(1) ROOF OPENING
FIGURE R804.3.10(2)HEADER TO TRIMMER CONNECTION
258 SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
SECTION R807 ATTIC ACCESS
SECTION R808 INSULATION CLEARANCE
259 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 ROOF CLASSIFICATION
SECTION R903 WEATHER PROTECTION
SECTION R904 MATERIALS
SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
261 TABLE R905.2.8.2 VALLEY LINING MATERIAL
262 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
263 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
264 TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
265 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
266 TABLE R905.10.3 METAL ROOF COVERINGS STANDARDS AND INSTALLATION
TABLE R905.11.2MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
267 SECTION R906 ROOF INSULATION
SECTION R907 REROOFING
269 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY CHIMNEYS
270 TABLE R1001.11(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1001.11(2) NET CROSS–SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZESa
271 FIGURE R1001.12.2 FLUE SIZES FOR MASONRY CHIMNEYS
272 FIGURE R1001.15 CLEARANCE FROM COMBUSTIBLES
FIGURE R1001.17 CHIMNEY CRICKET
273 TABLE R1001.17 CRICKET DIMENSIONS
SECTION R1002 FACTORY-BUILT CHIMNEYS
SECTION R1003 MASONRY FIREPLACES
274 TABLE R1003.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
275 FIGURE R1003.1 FIREPLACE AND CHIMNEY DETAILS
277 SECTION R1004 FACTORY-BUILT FIREPLACES
SECTION R1005 EXTERIOR AIR SUPPLY
SECTION R1006 MASONRY HEATERS
278 FIGURE R1003.12 CLEARANCE FROM COMBUSTIBLES
279 PART IV – ENERGY CONSERVATION
CHAPTER 11 ENERGY EFFICIENCY
SECTION N1101 GENERAL
280 TABLE N1101.2 NEW YORK STATE RESIDENTIAL CLIMATE ZONES
281 TABLE N1101.5(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE N1101.5(2) DEFAULT DOOR U-FACTORS
TABLE N1101.5(3) DEFAULT GLAZED FENESTRATION SHGC
282 SECTION N1102 BUILDING THERMAL ENVELOPE
TABLE N1102.1(1) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE N1102.1(2) ALTERNATIVE INSULATION REQUIREMENTS BY COMPONENTa (See Section N1102.1 exception 3)
TABLE N1102.1.2 EQUIVALENT U-FACTORSa
283 TABLE N1102.1.4 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT FOR RESIDENCES USING ELECTRIC RESISTANCE HEATING
284 TABLE N1102.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
285 SECTION N1103 SYSTEMS
286 TABLE N1103.7 OPTIONAL MECHANICAL EQUIPMENT EFFICIENCY REQUIREMENTS
287 PART V – MECHANICAL
CHAPTER 12 MECHANICAL
SECTION M1201 GENERAL
[EB] SECTION M1202 EXISTING MECHANICAL SYSTEMS
289 CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS
SECTION M1301 GENERAL
SECTION M1302 APPROVAL
SECTION M1303 LABELING OF APPLIANCES
SECTION M1304 TYPE OF FUEL
SECTION M1305 APPLIANCE ACCESS
290 SECTION M1306 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
FIGURE M1306.1 REDUCED CLEARANCE DIAGRAM
291 FIGURE M1306.2 WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
292 TABLE M1306.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa,b,c,d,e,f,g,h,i,j,k
293 SECTION M1307 APPLIANCE INSTALLATION
SECTION M1308 MECHANICAL SYSTEMS INSTALLATION
295 CHAPTER 14 HEATING AND COOLING EQUIPMENT
SECTION M1401 GENERAL
SECTION M1402 CENTRAL FURNACES
SECTION M1403 HEAT PUMP EQUIPMENT
SECTION M1404 REFRIGERATION COOLING EQUIPMENT
SECTION M1405 BASEBOARD CONVECTORS
SECTION M1406 RADIANT HEATING SYSTEMS
296 SECTION M1407 DUCT HEATERS
SECTION M1408 VENTED FLOOR FURNACES
SECTION M1409 VENTED WALL FURNACES
297 SECTION M1410 VENTED ROOM HEATERS
SECTION M1411 REFRIGERATION COOLING EQUIPMENT
298 SECTION M1412 ABSORPTION COOLING EQUIPMENT
SECTION M1413 EVAPORATIVE COOLING EQUIPMENT
SECTION 1414 FIREPLACE (WOOD) STOVES
SECTION M1415 MASONRY HEATERS
SECTION 1416 KEROSENE AND OIL-FIRED STOVES ANDHEATERS
299 CHAPTER 15 EXHAUST SYSTEMS
SECTION M1501 CLOTHES DRYERS EXHAUST
SECTION M1502 RANGE HOODS
SECTION M1503 INSTALLATION OF MICROWAVE OVENS
SECTION M1504 OVERHEAD EXHAUST HOODS
300 SECTION M1505 EXHAUST DUCTS
SECTION M1506 MECHANICAL VENTILATION
TABLE M1506.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS
301 CHAPTER 16 DUCT SYSTEMS
SECTION M1601 DUCT CONSTRUCTION
TABLE M1601.1.1(1) CLASSIFICATION OF FACTORY-MADE AIR DUCTS
TABLE M1601.1.1(2) GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING
303 SECTION M1602 RETURN AIR
305 CHAPTER 17 COMBUSTION AIR
SECTION M1701 GENERAL
SECTION M1702 ALL AIR FROM INSIDE THE BUILDING
SECTION M1703 ALL AIR FROM OUTDOORS
306 FIGURE M1702.2 APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM ADJACENT SPACES WITHIN THE BUILDING
307 FIGURE M1703.2(1) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH TWO OPENINGS
FIGURE M1703.2(2) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH HORIZONTAL DUCTS
308 FIGURE M1703.2(3) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE M1703.2(4) APPLIANCES LOCATED IN CONFINED SPACES—INLET AIR TAKEN FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
309 FIGURE M1703.3 APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH VENTILATED ATTIC, INLET DUCT WITHIN OUTLET DUCT
311 CHAPTER 18 CHIMNEYS AND VENTS
SECTION M1801 GENERAL
SECTION M1802 VENT COMPONENTS
312 SECTION M1803 CHIMNEY AND VENT CONNECTORS
TABLE M1803.2 THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS
TABLE M1803.3.4 CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa
313 SECTION M1804 VENTS
TABLE M1804.1 VENT SELECTION CHART
SECTION M1805 MASONRY AND FACTORY-BUILT CHIMNEYS
315 CHAPTER 19 SPECIAL FUEL-BURNING EQUIPMENT
SECTION M1901 COOKING APPLIANCES
SECTION M1902 SAUNA HEATERS
SECTION M1903 STATIONARY FUEL CELL POWER PLANTS
317 CHAPTER 20 BOILERS AND WATER HEATERS
SECTION M2001 BOILERS
SECTION M2002 OPERATING AND SAFETY CONTROLS
SECTION M2003 EXPANSION TANKS
SECTION M2004 WATER HEATERS USED FOR SPACE HEATING
SECTION M2005 WATER HEATERS
318 TABLE M2003.2 EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT–WATER SYSTEMS
SECTION M2006 POOL HEATERS
319 CHAPTER 21 HYDRONIC PIPING
SECTION M2101 HYDRONIC PIPING SYSTEMS INSTALLATION
TABLE M2101.1 HYDRONIC PIPING MATERIALS
320 TABLE M2101.9 HANGER SPACING INTERVALS
SECTION M2102 BASEBOARD CONVECTORS
SECTION M2103 FLOOR HEATING SYSTEMS
321 SECTION M2104 LOW TEMPERATURE PIPING
SECTION M2105 GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING
323 CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION M2201 OIL TANKS
SECTION M2202 OIL PIPING, FITTING AND CONNECTIONS
SECTION M2203 INSTALLATION
324 SECTION M2204 OIL PUMPS AND VALVES
325 CHAPTER 23 SOLAR SYSTEMS
SECTION M2301 SOLAR ENERGY SYSTEMS
327 PART VI – FUEL GAS
CHAPTER 24 FUEL GAS
SECTION G2401 (101) GENERAL
SECTION G2402 (201) GENERAL
SECTION G2403 (202) DEFINITIONS
SECTION G2404 (301) GENERAL REGULATIONS
328 SECTION G2405 (302) STRUCTURAL SAFETY
SECTION G2406 (303) APPLIANCE LOCATION
SECTION G2407 (304) COMBUSTION, VENTILATION AND DILUTION AIR
329 (EQUATION 24-1)
(EQUATION 24-2)
FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING (see Section G2407.5.3)
330 FIGURE G2407.6.1(1) [304.6.1(1)] ALL AIR FROM OUTDOOR—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section G2407.6.1)
331 FIGURE G2407.6.1(2) [304.6.1(2) ]ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section G2407.6.1)
FIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS (see Section G2407.6.1)
332 FIGURE G2407.6.2 (304.6.2) SINGLE COMBUSTION AIR OPENING—ALL AIR FROM OUTDOORS (see Section G2407.6.2.)
333 SECTION G2408 (305) INSTALLATION
SECTION G2409 (308) CLEARANCE REDUCTION
334 TABLE G2409.2 (308.2) REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa,b,c,d,e,f,g,h,i,j,k
335 FIGURE G2409.2(1) [308.2(1)] EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTORS
FIGURE G2409.2(2) [308.2(2)] WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
336 SECTION G2410 (309) ELECTRICAL
SECTION G2411 (310) ELECTRICAL BONDING
SECTION G2412 (401) GAS PIPING SYSTEMS
337 SECTION G2413 (402) PIPE SIZING
TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
338 (EQUATION 24-3)
(EQUATION 24-4)
TABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
SECTION G2414 (403) PIPING MATERIALS
339 TABLE G2413.4(1) [402.4(2) ]SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(2) [402.4(3)] SCHEDULE 40 METALLIC PIPE
340 TABLE G2413.4(3) [402.4(8)] SEMI-RIGID COPPER TUBING
341 TABLE G2413.4(4) [402.4(11)] SEMI-RIGID COPPER TUBING
342 TABLE G2413.4(5) [402.4(14)] CORRUGATED STAINLESS STEEL TUBING (CSST)
343 TABLE G2413.4(6) [402.4(17)] CORRUGATED STAINLESS STEEL TUBING (CSST)
344 TABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE
345 SECTION G2415 (404) PIPING SYSTEM INSTALLATION
346 SECTION G2416 (405) PIPING BENDS AND CHANGES IN DIRECTION
347 SECTION G2417 (406) INSPECTION, TESTING AND PURGING
348 SECTION G2418 (407) PIPING SUPPORT
SECTION G2419 (408) DRIPS AND SLOPED PIPING
SECTION G2420 (409) GAS SHUTOFF VALVES
349 SECTION G2421 (410 )FLOW CONTROLS
SECTION G2422 (411) APPLIANCE CONNECTIONS
350 SECTION G2423 (413) CNG GAS-DISPENSING SYSTEMS
SECTION G2424 (415) PIPING SUPPORT INTERVALS
TABLE G2424.1 SUPPORT OF PIPING
SECTION G2425 (501) CHIMNEYS AND VENTS
351 SECTION G2426 (502) VENTS
352 SECTION G2427 (503) VENTING OF EQUIPMENT
353 TABLE G2427.4 (503.4) TYPE OF VENTING SYSTEM TO BE USED
354 FIGURE G2427.5.3 (503.5.4) TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES
356 FIGURE G2427.6.5 (503.6.6) GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
357 TABLE G2427.7.7 (503.7.7) CLEARANCES FOR CONNECTORS
358 FIGURE G2427.8
359 TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
361 SECTION G2428 (504) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
363 TABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT
364 TABLE G2428.2(1) [504.2(1)]—continued TYPE B DOUBLE-WALL GAS VENT
365 TABLE G2428.2(2) [504.2(2)] TYPE B DOUBLE-WALL GAS VENT
366 TABLE G2428.2(2) [504.2(2)—continued] TYPE B DOUBLE-WALL GAS VENT
367 TABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT
368 TABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL VENT
369 TABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY
370 TABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY
371 TABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH
372 SECTION G2429 (505) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION G2430 (506) FACTORY-BUILT CHIMNEYS
373 SECTION G2431 (601) SPECIFIC APPLIANCES
SECTION G2432 (602) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION G2433 (603) LOG LIGHTERS
SECTION G2434 (604) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS
SECTION G2436 (608) VENTED WALL FURNACES
SECTION G2437 (609) FLOOR FURNACES
374 SECTION G2438 (613) CLOTHES DRYERS
SECTION G2439 (614) CLOTHES DRYER EXHAUST
SECTION G2440 (615) SAUNA HEATERS
375 SECTION G2441 (617) POOL AND SPA HEATERS
SECTION G2442 (618) FORCED-AIR WARM-AIR FURNACES
376 SECTION G2443 (619) CONVERSION BURNERS
SECTION G2444 (620) UNIT HEATERS
SECTION G2445 (621) UNVENTED ROOM HEATERS
SECTION G2446 (622) VENTED ROOM HEATERS
377 SECTION G2447 (623) COOKING APPLIANCES
SECTION G2448 (624) WATER HEATERS
SECTION G2449 (627) AIR CONDITIONING EQUIPMENT
SECTION G2450 (628) ILLUMINATING APPLIANCES
SECTION G2451 (630) INFRARED RADIANT HEATERS
378 SECTION G2452 (631) BOILERS
SECTION G2453 (634) CHIMNEY DAMPER OPENING AREA
TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION G2454 (633) STATIONARY FUEL CELL POWER PLANTS
379 PART VII – PLUMBING
CHAPTER 25 PLUMBING
SECTION P2501 GENERAL
[EB] SECTION P2502 EXISTING PLUMBING SYSTEMS
SECTION P2503 INSPECTION AND TESTS
381 CHAPTER 26 GENERAL PLUMBING REQUIREMENTS
SECTION P2601 GENERAL
SECTION P2602 INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL
SECTION P2603 STRUCTURAL AND PIPING PROTECTION
382 SECTION P2604 TRENCHING AND BACKFILLING
FIGURE P2604.4 PIPE LOCATION WITH RESPECT TO FOOTINGS
SECTION P2605 SUPPORT
SECTION P2606 WATERPROOFING OF OPENINGS
383 TABLE P2605.1 PIPING SUPPORT
SECTION P2607 WORKMANSHIP
SECTION P2608 MATERIALS EVALUATION AND LISTING
384 TABLE P2608.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION
385 CHAPTER 27 PLUMBING FIXTURES
SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS
TABLE P2701.1 PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS
386 SECTION P2702 FIXTURE ACCESSORIES
SECTION P2703 TAIL PIECES
SECTION P2704 ACCESS TO CONNECTIONS
SECTION P2705 INSTALLATION
SECTION P2706 WASTE RECEPTORS
SECTION P2707 DIRECTIONAL FITTINGS
387 SECTION P2708 SHOWERS
SECTION P2709 SHOWER RECEPTORS
SECTION P2710 SHOWER WALLS
SECTION P2711 LAVATORIES
388 SECTION P2712 WATER CLOSETS
SECTION P2713 BATHTUBS
SECTION P2714 SINKS
SECTION P2715 LAUNDRY TUBS
SECTION P2716 FOOD WASTE GRINDER
SECTION P2717 DISHWASHING MACHINES
389 SECTION P2718 CLOTHES WASHING MACHINE
SECTION P2719 FLOOR DRAINS
SECTION P2720 WHIRLPOOL BATHTUBS
SECTION P2721 BIDET INSTALLATIONS
SECTION P2722 FIXTURE FITTING
SECTION P2723 MACERATING TOILET SYSTEMS
SECTION P2724 SPECIALTY TEMPERATURE CONTROL DEVICES AND VALVES
391 CHAPTER 28 WATER HEATERS
SECTION P2801 GENERAL
SECTION P2802 WATER HEATERS USED FOR SPACE HEATING
SECTION P2803 RELIEF VALVES
393 CHAPTER 29 WATER SUPPLY AND DISTRIBUTION
SECTION P2901 GENERAL
SECTION P2902 PROTECTION OF POTABLE WATER SUPPLY
394 TABLE P2902.2 APPLICATION FOR BACKFLOW PREVENTERS
395 SECTION P2903 WATER-SUPPLY SYSTEM
TABLE P2903.1 REQUIRED CAPACITIES AT POINT OF OUTLET DISCHARGE
TABLE P2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGSb
396 TABLE P2903.6 WATER-SUPPLY FIXTURE-UNIT VALUES FOR VARIOUS PLUMBING FIXTURES AND FIXTURE GROUPS
397 TABLE P2903.6(1) CONVERSIONS FROM WATER SUPPLY FIXTURE UNIT TO GALLON PER MINUTE FLOW RATES
399 TABLE P2903.7 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES
400 TABLE P2903.7—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES
TABLE P2903.8.1 MANIFOLD SIZING
401 FIGURE P2903.10 TYPICAL FROST-PROOF HOSE BIBB INSTALLATION NOT REQUIRING SEPARATE VALUE
SECTION P2904 MATERIALS, JOINTS AND CONNECTIONS
402 TABLE P2904.4.1 WATER SERVICE PIPEa
403 TABLE P2904.5 WATER DISTRIBUTION PIPE
TABLE P2904.6 PIPE FITTINGS
405 SECTION P2905 CHANGES IN DIRECTION
SECTION P2906 SUPPORT
SECTION P2907 DRINKING WATER TREATMENT UNITS
407 CHAPTER 30 SANITARY DRAINAGE
SECTION P3001 GENERAL
SECTION P3002 MATERIALS
SECTION P3003 JOINTS AND CONNECTIONS
408 TABLE P3002.1 DRAIN, WASTE AND VENT PIPING AND FITTING MATERIALS
409 TABLE P3002.2 BUILDING SEWER PIPING AND FITTINGS
410 SECTION P3004 DETERMINING DRAINAGE FIXTURE UNITS
SECTION P3005 DRAINAGE SYSTEM
411 TABLE P3004.1 DRAINAGE FIXTURE UNIT (d.f.u.) VALUES FOR VARIOUS PLUMBING FIXTURES
412 TABLE P3005.1 FITTINGS FOR CHANGE IN DIRECTION
413 TABLE P3005.2.9 CLEANOUTS
TABLE P3005.4.1 MAXIMUM FIXTURE UNITS ALLOWED TO BE CONNECTED TO BRANCHES AND STACKS
TABLE P3005.4.2 MAXIMUM NUMBER OF FIXTURE UNITS ALLOWED TO BE CONNECTED TO THE BUILDING DRAIN, BUILDING DRAIN BRANCHES OR THE BUILDING SEWER
414 SECTION P3006 SIZING OF DRAIN PIPE OFFSETS
SECTION P3007 SUMPS AND EJECTORS
SECTION P3008 BACKWATER VALVES
415 CHAPTER 31 VENTS
SECTION P3101 VENT SYSTEMS
SECTION P3102 VENT STACKS AND STACK VENTS
SECTION P3103 VENT TERMINALS
SECTION P3104 VENT CONNECTIONS AND GRADES
416 SECTION P3105 FIXTURE VENTS
TABLE P3105.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION P3106 INDIVIDUAL VENT
SECTION P3107 COMMON VENT
417 TABLE P3107.3 COMMON VENT SIZES
SECTION P3108 WET VENTING
TABLE P3108.3 WET VENT SIZE
SECTION P3109 WASTE STACK VENT
TABLE P3109.4 WASTE STACK VENT SIZE
SECTION P3110 CIRCUIT VENTING
418 SECTION P3111 COMBINATION WASTE AND VENT SYSTEM
TABLE P3111.3 SIZE OF COMBINATION WASTE AND VENT PIPE
SECTION P3112 ISLAND FIXTURE VENTING
SECTION P3113 VENT PIPE SIZING
419 TABLE P3113.4.1 SIZE AND LENGTH OF SUMP VENTS
SECTION P3114 AIR ADMITTANCE VALVES
420 FIGURE P3108.1(1) TYPICAL SINGLE-BATH WET-VENT ARRANGEMENTS
421 FIGURE P3108.1(2) TYPICAL DOUBLE-BATH WET-VENT ARRANGEMENTS
422 FIGURE P3108.1(3) TYPICAL HORIZONTAL WET VENTING
423 FIGURE P3108.1(4) TYPICAL METHODS OF WET VENTING
424 FIGURE P3108.1(5) SINGLE-STACK SYSTEM FOR A TWO-STORY DWELLING
425 FIGURE P3109.2 WET STACK VENTING
426 FIGURE P3110.4 CIRCUIT VENT WITH ADDITIONAL NONCIRCUIT VENTED BRANCHES
427 CHAPTER 32 TRAPS
SECTION P3201 FIXTURE TRAPS
TABLE P3201.7 SIZE OF TRAPS AND TRAP ARMS FOR PLUMBING FIXTURES
429 PART VIII – ELECTRICAL
CHAPTER 33 GENERAL REQUIREMENTS
SECTION E3301 GENERAL
SECTION E3302 BUILDING STRUCTURE PROTECTION
SECTION E3303 APPROVAL
SECTION E3304 GENERAL EQUIPMENT REQUIREMENTS
430 SECTION E3305 EQUIPMENT LOCATION AND CLEARANCES
431 FIGURE E3305.1a,b,c,d,e WORKING SPACE AND CLEARANCES
432 SECTION E3306 ELECTRICAL CONDUCTORS AND CONNECTIONS
SECTION E3307 CONDUCTOR AND TERMINAL IDENTIFICATION
435 CHAPTER 34 ELECTRICAL DEFINITIONS
SECTION E3401 GENERAL
439 CHAPTER 35 SERVICES
SECTION E3501 GENERAL SERVICES
SECTION E3502 SERVICE SIZE AND RATING
TABLE E3502.2 MINIMUM SERVICE LOAD CALCULATION
440 SECTION E3503 SERVICE, FEEDER AND GROUNDING ELECTRODE CONDUCTOR SIZING
TABLE E3503.1 SERVICE CONDUCTOR AND GROUNDING ELECTRODE CONDUCTOR SIZING
441 SECTION E3504 OVERHEAD SERVICE-DROP AND SERVICE CONDUCTOR INSTALLATION
FIGURE E3504.1 CLEARANCES FROM BUILDING OPENINGS
442 FIGURE E3504.2.1 CLEARANCES FROM ROOFS
443 SECTION E3505 SERVICE-ENTRANCE CONDUCTORS
SECTION E3506 SERVICE EQUIPMENT—GENERAL
444 SECTION E3507 SYSTEM GROUNDING
SECTION E3508 GROUNDING ELECTRODE SYSTEM
445 SECTION E3509 BONDING
446 SECTION E3510 GROUNDING ELECTRODE CONDUCTORS
SECTION E3511 GROUNDING ELECTRODE CONDUCTOR CONNECTION TO THE GROUNDING ELECTRODES
449 CHAPTER 36 BRANCH CIRCUIT AND FEEDER REQUIREMENTS
SECTION E3601 GENERAL
SECTION E3602 BRANCH CIRCUIT RATINGS
450 TABLE E3602.13 BRANCH-CIRCUIT REQUIREMENTS—SUMMARYa,b
SECTION E3603 REQUIRED BRANCH CIRCUITS
451 SECTION E3604 FEEDER REQUIREMENTS
TABLE E3604.3(1) FEEDER LOAD CALCULATION
452 TABLE E3604.3(2) DEMAND LOADS FOR ELECTRIC RANGES, WALL-MOUNTED OVENS, COUNTER-MOUNTED COOKING UNITS AND OTHER COOKING APPLIANCES OVER 13/4 kVA RATINGa,b
SECTION E3605 CONDUCTOR SIZING AND OVERCURRENT PROTECTION
TABLE E3605.1 ALLOWABLE AMPACITIES
453 TABLE E3605.2 AMBIENT TEMPERATURE CORRECTION FACTORS
TABLE E3605.3 CONDUCTOR PROXIMITY ADJUSTMENT FACTORS
454 TABLE E3605.5.3 OVERCURRENT-PROTECTION RATING
455 SECTION E3606 PANELBOARDS
457 CHAPTER 37 WIRING METHODS
SECTION E3701 GENERAL REQUIREMENTS
TABLE E3701.2 ALLOWABLE WIRING METHODS
SECTION E3702 ABOVE-GROUND INSTALLATION REQUIREMENTS
458 TABLE E3701.4 ALLOWABLE APPLICATIONS FOR WIRING METHODSa,b,c,d,e,f,g,h,i
459 TABLE E3702.1 GENERAL INSTALLATION AND SUPPORT REQUIREMENTS FOR WIRING METHODSa,b,c,d,e,f,g,h,i
460 SECTION E3703 UNDERGROUND INSTALLATION REQUIREMENTS
TABLE E3703.1 MINIMUM COVER REQUIREMENTS, BURIAL IN INCHESa,b,c,d
463 CHAPTER 38 POWER AND LIGHTING DISTRIBUTION
SECTION E3801 RECEPTACLE OUTLETS
FIGURE E3801.2 GENERAL USE RECEPTACLE DISTRIBUTION
464 FIGURE E3801.4 COUNTERTOP RECEPTACLES
465 SECTION E3802 GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION
SECTION E3803 LIGHTING OUTLETS
466 SECTION E3804 GENERAL INSTALLATION REQUIREMENTS
SECTION E3805 BOXES, CONDUIT BODIES AND FITTINGS
467 TABLE E3804.6(1) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METALLIC TUBING (EMT)a
468 TABLE E3804.6(2) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL NONMETALLIC TUBING (ENT)a
469 TABLE E3804.6(3) MAXIMUM NUMBER OF CONDUCTORS IN FLEXIBLE METALLIC CONDUIT (FMC)a
470 TABLE E3804.6(4) MAXIMUM NUMBER OF CONDUCTORS IN INTERMEDIATE METALLIC CONDUIT (IMC)a
471 TABLE E3804.6(5) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-B)a
472 TABLE E3804.6(6) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-A)a
473 TABLE E3804.6(7) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC)a
474 TABLE E3804.6(8) MAXIMUM NUMBER OF CONDUCTORS IN RIGID METAL CONDUIT (RMC)a
475 TABLE E3804.6(9) MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT, SCHEDULE 80 (PVC-80)a
476 TABLE E3804.6(10)MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT SCHEDULE 40 (PVC-40)a
478 TABLE E3805.12.1 MAXIMUM NUMBER OF CONDUCTORS IN METAL BOXESa
TABLE E3805.12.2.1 VOLUME ALLOWANCE REQUIRED PER CONDUCTOR
479 SECTION E3806 INSTALLATION OF BOXES, CONDUITBODIES AND FITTINGS
480 SECTION E3807 CABINETS AND PANELBOARDS
481 SECTION E3808 GROUNDING
482 TABLE E3808.12 EQUIPMENT GROUNDING CONDUCTOR SIZING
483 SECTION E3809 FLEXIBLE CORDS
484 TABLE E3809.2 MAXIMUM AMPERE LOAD AND OVERCURRENT PROTECTION-DEVICE RATING FOR FLEXIBLE CORDS
485 CHAPTER 39 DEVICES AND LUMINAIRES
SECTION E3901 SWITCHES
SECTION E3902 RECEPTACLES
486 TABLE E3902.1.2 RECEPTACLE RATINGS FOR VARIOUS SIZE MULTIOUTLET CIRCUITS
SECTION E3903 FIXTURES
487 FIGURE E3903.11 CLOSET STORAGE SPACE
488 SECTION E3904 LUMINAIRE INSTALLATION
SECTION E3905 TRACK LIGHTING
489 CHAPTER 40 APPLIANCE INSTALLATION
SECTION E4001 GENERAL
TABLE E4001.3 FLEXIBLE CORD LENGTH
490 TABLE E4001. 5DISCONNECTING MEANS
491 CHAPTER 41 SWIMMING POOLS
SECTION E4101 GENERAL
SECTION E4102 WIRING METHODS FOR POOLS, SPAS, HOT TUBS AND HYDROMASSAGE BATHTUBS
492 TABLE E4102.1 ALLOWABLE APPLICATIONS FOR WIRING METHODSa,b,c,d,e,f,g
493 SECTION E4103 EQUIPMENT LOCATION AND CLEARANCES
494 TABLE E4103.5 OVERHEAD CONDUCTOR CLEARANCES
TABLE E4103. 6MINIMUM BURIAL DEPTHS
SECTION E4104 BONDING
495 SECTION E4105 GROUNDING
496 SECTION E4106 EQUIPMENT INSTALLATION
498 SECTION E4107 STORABLE SWIMMING POOLS
SECTION E4108 SPAS AND HOT TUBS
499 SECTION E4109 HYDROMASSAGE BATHTUBS
501 CHAPTER 42 CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS
SECTION E4201 GENERAL
SECTION E4202 POWER SOURCES
SECTION E4203 WIRING METHODS
TABLE E4203.2 CABLE USES AND PERMITTED SUBSTITUTIONS
SECTION E4204 INSTALLATION REQUIREMENTS
503 PART IX – REFERENCED STANDARDS
CHAPTER 43 REFERENCED STANDARDS
AAMA
ACI
ACCA
AFPA
504 AHA
AISI
AITC
ANSI
505 APA
ASCE
506 ASHRAE
ASME
507 ASSE
ASTM
513 AWPA
AWWA
CDA
514 CGSB
CISPI
CPSC
CSA
515 CSSB
DOC
DOTn
FEMA
516 FM
GA
HUD
HPVA
IAS
ICC
517 MSS
NAIMA
NCMA
NCSBCS
NFPA
518 NFRC
NSF
NYSDEC
NYSDH
RMA
519 SAE
SMACNA
TMS
TPI
UL
520 ULC
WDMA
521 PART X – APPENDICES
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
522 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
523 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
524 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(21) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
526 USE OF SIZING EQUATION
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
527 TABLE A.5.2 COPPER TUBE STANDARD SIZES — CONTINUED
FIGURE A.6 (a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC)
528 FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above)
529 FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM
530 FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.7.4PIPING PLAN SHOWING A MODIFICATIONTO EXISTING PIPING SYSTEM
533 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
534 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
535 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT HOOD-EQUIPPED APPLIANCES
536 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
537 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
538 FIGURE B-17 (EXAMPLE 3) COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES
539 FIGURE B-18 (EXAMPLE 4) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
540 TABLE B-1MASONRY CHIMNEY LINER DIMENSIONSWITH CIRCULAR EQUIVALENTS
541 APPENDIX C PLUMBING SANITARY DRAINAGE FILTERS
FIGURE 706.3(1) COMPARISON OF DIFFERENT 11/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIALS
542 FIGURE 706.3(2) COMPARISON OF 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIALS
543 FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS
544 FIGURE 706.3(3)BDRAINAGE PATTERN FITTINGS
545 FIGURE 706.3(4) DIFFERENCE BETWEEN PVC PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT
FIGURE 706.3(5) BACK-TO-BACK BLOWOUT FIXTURES
FIGURE 706.3(6) HEEL INLET FITTINGS
546 FIGURE 706.3(7) COMBINATION TEES
FIGURE 706.3(8) FITTING USES
547 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
549 APPENDIX E MANUFACTURED HOUSING USED AS DWELLINGS
SECTION AE101 SCOPE
SECTION AE102 APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT
550 SECTION AE201 DEFINITIONS
SECTION AE301 RESERVED
SECTION AE302 RESERVED
SECTION AE303 RESERVED
SECTION AE304 RESERVED
SECTION AE305 RESERVED
SECTION AE306 RESERVED
SECTION AE307 RESERVED
SECTION AE401 OCCUPANCY CLASSIFICATION
551 SECTION AE402 LOCATION ON PROPERTY
SECTION AE501 DESIGN
SECTION AE502 FOUNDATION SYSTEMS
SECTION AE503 SKIRTING AND PERIMETER ENCLOSURES
552 SECTION AE504 STRUCTURAL ADDITIONS
SECTION AE505 BUILDING SERVICE EQUIPMENT
SECTION AE506 EXITS
SECTION AE507 OCCUPANCY, FIRE SAFETY AND ENERGY CONSERVATION STANDARDS
SECTION AE600 SPECIAL REQUIREMENTS FOR FOUNDATION SYSTEMS
SECTION AE601 FOOTINGS AND FOUNDATIONS
SECTION AE602 PIER CONSTRUCTION
SECTION AE603 HEIGHT OF PIERS
553 SECTION AE604 ANCHORAGE INSTALLATIONS
SECTION AE605 TIES, MATERIALS AND INSTALLATION
554 SECTION AE606 REFERENCED STANDARDS
555 APPENDIX F RESERVED
557 APPENDIX G SWIMMING POOLS, SPAS AND HOT TUB
SECTION AG101 GENERAL
SECTION AG102 DEFINITIONS
SECTION AG103 SWIMMING POOLS
SECTION AG104 SPAS AND HOT TUBS
SECTION AG105 BARRIER REQUIREMENTS
558 SECTION AG106 ENTRAPMENT PROTECTION FOR SWIMMING POOL AND SPA SUCTION OUTLETS
559 SECTION AG107 ABBREVIATIONS
SECTION AG108 STANDARDS
561 APPENDIX H PATIO COVERS
SECTION AH101 GENERAL
SECTION AH102 DEFINITION
SECTION AH103 PERMITTED USES
SECTION AH104 DESIGN LOADS
SECTION AH105 LIGHT AND VENTILATION/EMERGENCY EGRESS
SECTION AH106 FOOTINGS
SECTION AH107 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
562 TABLE AH107.4(1) DESIGN WIND PRESSURES FOR ALUMINUM SCREEN ENCLOSURE FRAMING WITH AN IMPORTANCE FACTOR OF 0.77a, b, c
TABLE AH107.4(2) HEIGHT ADJUSTMENT FACTORS
563 APPENDIX I RESERVED
565 APPENDIX J EXISTING BUILDINGS AND STRUCTURES
SECTION AJ1 ADMINISTRATION
SECTION AJ101 PURPOSE AND INTENT
SECTION AJ102 COMPLIANCE
SECTION AJ103 APPLICABILITY
566 SECTION AJ104 ENERGY EFFICIENCY
SECTION AJ105 PRELIMINARY MEETING
SECTION AJ106 BUILDING EVALUATION
SECTION AJ2 DEFINITIONS
SECTION AJ201 GENERAL
SECTION AJ202 GENERAL DEFINITIONS
567 SECTION AJ3 CLASSIFICATION OF WORK
SECTION AJ301 GENERAL
SECTION AJ302 REPAIRS
SECTION AJ303 ALTERATIONS – LEVEL 1
568 SECTION AJ304 ALTERATIONS – LEVEL 2
SECTION AJ305 CHANGE OF OCCUPANCY
SECTION AJ306 ADDITIONS
SECTION AJ307 HISTORIC BUILDINGS
SECTION AJ308 RELOCATED BUILDINGS
SECTION AJ309 REPLACEMENT
SECTION AJ4 REPAIRS
SECTION AJ401 GENERAL
SECTION AJ402 BUILDING ELEMENTS AND MATERIALS
SECTION AJ403 FIRE AND LIFE SAFETY PROTECTION
569 SECTION AJ404 STRUCTURAL
SECTION AJ405 MECHANICAL
SECTION AJ406 PLUMBING
SECTION AJ407 ELECTRICAL
570 SECTION AJ5 ALTERATIONS – LEVEL 1
SECTION AJ501 GENERAL
SECTION AJ502 BUILDING ELEMENTS AND MATERIALS
SECTION AJ503 MEANS OF EGRESS
571 SECTION AJ504 FIRE AND LIFE-SAFETY PROTECTION
SECTION AJ505 STRUCTURAL
AJ506 MECHANICAL
AJ507 PLUMBING
AJ508 ELECTRICAL
SECTION AJ6 ALTERATIONS – LEVEL 2
SECTION AJ601 GENERAL
572 SECTION AJ602 BUILDING ELEMENTS AND MATERIALS
SECTION AJ603 MEANS OF EGRESS
SECTION AJ604 FIRE AND LIFE-SAFETY PROTECTION
573 SECTION AJ605 STRUCTURAL
SECTION AJ606 MECHANICAL
SECTION AJ607 PLUMBING
SECTION AJ608 ELECTRICAL
574 SECTION AJ7 CHANGE OF OCCUPANCY
SECTION AJ701 GENERAL
SECTION AJ702 COMPLIANCE
SECTION AJ703 FIRE AND LIFE-SAFETY PROTECTION
SECTION AJ704 BED AND BREAKFAST DWELLINGS
575 SECTION AJ8 ADDITIONS
SECTION AJ801 GENERAL
SECTION AJ802 FIRE AND LIFE-SAFETY PROTECTION
SECTION AJ803 STRUCTURAL
576 SECTION AJ804 MECHANICAL
SECTION AJ805 PLUMBING
SECTION AJ806 ELECTRICAL
SECTION AJ9 HISTORIC BUILDINGS
SECTION AJ901 GENERAL
SECTION AJ902 FIRE AND-LIFE SAFETY PROTECTION
577 SECTION AJ903 BUILDING ELEMENTS AND MATERIALS
SECTION AJ904 STRUCTURAL
SECTION AJ905 REPAIRS
SECTION AJ906 ALTERATIONS
SECTION AJ907 CHANGE OF OCCUPANCY
SECTION AJ908 RELOCATED BUILDINGS
578 SECTION AJ10 RELOCATED OR MOVED BUILDINGS
SECTION AJ1001 GENERAL
SECTION AJ1002 BUILDING ELEMENTS AND MATERIALS
SECTION AJ1003 FIRE AND LIFE SAFETY PROTECTION
SECTION AJ1004 STRUCTURAL
SECTION AJ11 REPLACEMENT
SECTION AJ1101 GENERAL
579 APPENDIX K SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIRBORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
581 APPENDIX L ICC INTERNATIONAL RESIDENTIAL CODE ELECTRICAL PROVISIONS/NATIONAL ELECTRICAL CODE CROSS-REFERENCE
593 INDEX
NY ResidentialCode 07 2007
$43.06