NY ResidentialCode 07 2007
$43.06
Residential Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2007 | 604 |
Based on the 2003 International Residential Code®, This code has been updated to reflect the latest technological advances in building design and construction. This code also contains plumbing, mechanical and fuel gas provisions that coordinate with the Plumbing Code, Mechanical Code and Fuel Gas Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | RESIDENTIAL CODE OF NEW YORK STATE 2007 |
2 | COPYRIGHT © 2007 |
3 | ACKNOWLEDGMENTS |
5 | TABLE OF CONTENTS |
13 | PART I — ADMINISTRATIVE CHAPTER 1 GENERAL REQUIREMENTS SECTION R101 TITLE, SCOPE AND PURPOSE SECTION R102 APPLICABILITY SECTION R103 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION |
14 | SECTION R104 SERVICE UTILITIES SECTION R105 ADMINISTRATION AND ENFORCEMENT |
15 | PART II – DEFINITIONS CHAPTER 2 DEFINITIONS SECTION R201 GENERAL SECTION R202 DEFINITIONS |
35 | PART III – BUILDING PLANNING AND CONSTRUCTION CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA |
36 | TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA |
37 | FIGURE R301.2(1) COMPONENT AND CLADDING PRESSURE ZONES |
38 | TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf) |
39 | TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa,b,c |
40 | FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES – SITE CLASS D |
41 | FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE |
42 | FIGURE R301.2(4) BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL |
43 | FIGURE R301.2(5) GROUND SNOW LOADS, Pg FOR NEW YORK STATE |
44 | FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP |
45 | FIGURE R301.2(7) DECAY PROBABILITY MAP |
46 | TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION |
47 | TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa |
49 | TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION TABLE R301.7ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa,b,c |
50 | SECTION R302 LOCATION ON LOT SECTION R303 LIGHT, VENTILATION AND HEATING |
51 | SECTION R304 MINIMUM ROOM AREAS SECTION R305 CEILING HEIGHT |
52 | SECTION R306 SANITATION SECTION R307 TOILET, BATH AND SHOWER SPACES FIGURE R307.2 MINIMUM FIXTURE CLEARANCES |
53 | SECTION R308 GLAZING TABLE R308.3 MINIMUM CATEGORY CLASSIFICATION OF GLAZING |
55 | SECTION R309 GARAGES AND CARPORTS SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS |
56 | SECTION R311 MEANS OF EGRESS |
58 | SECTION R312 GUARDS SECTION R313 SMOKE ALARMS, AUTOMATIC SPRINKLER SYSTEMS AND CARBON MONOXIDE ALARMS |
59 | SECTION R314 FOAM PLASTIC |
60 | [B] SECTION R315 FLAME SPREAD AND SMOKE DENSITY [B] SECTION R316 INSULATION |
61 | SECTION R317 DWELLING UNIT SEPARATION |
62 | SECTION R318 MOISTURE VAPOR RETARDERS SECTION R319 PROTECTION AGAINST DECAY |
63 | SECTION R320 PROTECTION AGAINST TERMITES |
64 | [F] SECTION R321 SITE ADDRESS [B] SECTION R322 ACCESSIBILITY SECTION R323 FLOOD-RESISTANT CONSTRUCTION |
67 | CHAPTER 4 FOUNDATIONS SECTION R401 GENERAL TABLE R401.4.1 PRESUMPTIVE LOAD–BEARING VALUES OF FOUNDATION MATERIALSa SECTION R402 MATERIALS |
68 | TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SECTION R403 FOOTINGS TABLE R403.1 MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS (inches)a |
69 | FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS |
70 | FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION |
71 | FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION |
72 | FIGURE R403.1.5 STEPPED FOOTING |
73 | FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES |
75 | FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS SECTION R404 FOUNDATION WALLS |
76 | FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE |
77 | TABLE R403.3 MINIMUM INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa |
78 | TABLE R403.3(1) AIR FREEZING INDEX (BASE 32 FAHRENHEIT) RETURN PERIOD OF 100 YEAR (99% probability) |
79 | FIGURE R403.3(4)INSULATION PLACEMENT FOR FROST-PROTECTEDFOOTINGS ADJACENT TO HEATED STRUCTURE |
80 | TABLE R404.1.1(1) PLAIN CONCRETE AND PLAIN MASONRY FOUNDATION WALLS |
81 | TABLE R404.1.1(2) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS TABLE R404.1.1(3) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS |
82 | TABLE R404.1.1(4) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS |
83 | FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS |
84 | TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure) |
85 | TABLE R404.4(1) 5.5-INCH THICK FLAT ICF FOUNDATION WALLSa,b,c,d |
86 | TABLE R404.4(2) 7.5-INCH THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e TABLE R404.4(3) 9.5-INCH THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e |
87 | TABLE R404.4(4) WAFFLE GRID ICF FOUNDATION WALLSa, b, c, d, e |
88 | TABLE R404.4(5)SCREEN-GRID ICF FOUNDATION WALLSa, b c, d, e |
89 | SECTION R405 FOUNDATION DRAINAGE SECTION R406 FOUNDATION WATERPROOFINGAND DAMPPROOFING |
90 | TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM SECTION R407 COLUMNS |
91 | SECTION R408 UNDER-FLOOR SPACE |
93 | CHAPTER 5 FLOORS SECTION R501 GENERAL SECTION R502 WOOD FLOOR FRAMING |
94 | FIGURE R502.2 FLOOR CONSTRUCTION |
95 | TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360) |
96 | TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360) |
97 | TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load 40 psf, Roof Live Load 20 psf) TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f |
98 | TABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and North American spruce-pine-firb and required number of jack studs) |
100 | FIGURE R502.8 CUTTING, NOTCHING AND DRILLING |
101 | SECTION R503 FLOOR SHEATHING TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING |
102 | TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa,b,c |
103 | TABLE 503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND) SECTION R505 STEEL FLOOR FRAMING |
104 | TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS FIGURE R505.2(1) C-SECTION FIGURE R505.2(2) TRACK SECTION |
105 | FIGURE R505.2(3) FLOOR JOIST WEB HOLES TABLE R505.2(3) MAXIMUM HOLE DIMENSIONS AND SPACING IN JOIST WEBS |
106 | TABLE R505.2.4 SCREW SUBSTITUTION FACTOR FIGURE R505.3 STEEL FLOOR CONSTRUCTION |
107 | FIGURE R505.3—continued STEEL FLOOR CONSTRUCTION |
108 | TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS a,b TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa FIGURE R505.3.1(1) FLOOR TO LOAD-BEARING WALL STUD CONNECTION |
109 | FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION |
110 | FIGURE R505.3.1(4) FLOOR CANTILEVER TO LOAD-BEARING WALL CONNECTION FIGURE R505.3.1(5) FLOOR CANTILEVER TO WOOD SILL CONNECTION |
111 | FIGURE R505.3.1(6) FLOOR CANTILEVER TO FOUNDATION CONNECTION FIGURE R505.3.1(7) CONTINUOUS JOIST SPAN SUPPORTED ON STUD |
112 | TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTSa,b |
113 | FIGURE R505.3.4BEARING STIFFENER |
114 | FIGURE R505.3.6 HOLE PATCH FIGURE R505.3.8TRACK SPLICE |
115 | SECTION R506 CONCRETE FLOORS (ON GROUND) |
117 | CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL SECTION R602 WOOD WALL FRAMING |
118 | TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
119 | TABLE R602.3(1)—continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
120 | TABLE R602.3(2) ALTERNATE ATTACHMENTS |
121 | TABLE R602.3(3) ALLOWABLE STUD SPACING FOR WOOD STRUCTURAL PANEL WALL SHEATHING TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa |
122 | FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING |
123 | FIGURE R602.3(2) FRAMING DETAILS |
124 | TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C and D1b,c |
125 | TABLE R602.3.1—continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C and D1 |
126 | FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS |
127 | FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS |
128 | FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING |
129 | TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION |
131 | TABLE R602.10.1 WALL BRACING |
132 | TABLE R602.10.5 LENGTH REQUIREMENTS FOR BRACED WALL PANELS IN A CONTINUOUSLY SHEATHED WALLa,b FIGURE R602.10.5 EXTERIOR CORNER FRAMING |
134 | TABLE R602.10.11 ADJUSTMENT OF BRACING AMOUNTS FOR INTERIOR BRACED WALL LINES ACCORDING TO BRACED WALL LINE SPACINGa,b SECTION R603 STEEL WALL FRAMING |
135 | FIGURE R602.11.3STEPPED FOUNDATION CONSTRUCTION |
136 | TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL STUDS |
137 | FIGURE R603.2(1) C-SECTION FIGURE R603.2(2) TRACK-SECTION |
138 | FIGURE R603.2(3) WEB HOLES FIGURE R603.3 STEEL WALL CONSTRUCTION |
139 | TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b,c FIGURE R603.3.1(1) WALL TO FOUNDATION CONNECTION |
140 | FIGURE R603.3.1(2) WALL TO WOOD SILL CONNECTION TABLE R603.3.2(1) WALL FASTENING SCHEDULEa |
141 | TABLE R603.3.2(2) COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 33 ksi steel |
142 | TABLE R603.3.2(3) COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 33 ksi steel |
143 | TABLE R603.3.2(4) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 33 ksi steel |
144 | TABLE R603.3.2(5) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 33 ksi steel |
145 | TABLE R603.3.2(6) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 33 ksi steel |
146 | TABLE R603.3.2(7) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 33 ksi steel |
147 | TABLE R603.3.2(8) COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 50 ksi steel |
148 | TABLE R603.3.2(9)COLD-FORMED STEEL STUD THICKNESS FOR 8-FOOT WALLSStuds supporting one floor, roof and ceiling (first story of a two-story building) 50 ksi steel |
149 | TABLE R603.3.2(10) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 50 ksi steel |
150 | TABLE R603.3.2(11) COLD-FORMED STEEL STUD THICKNESS FOR 9-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 50 ksi steel |
151 | TABLE R603.3.2(12) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting roof and ceiling only (one-story building or second floor of a two-story building) 50 ksi steel |
152 | TABLE R603.3.2(13) COLD-FORMED STEEL STUD THICKNESS FOR 10-FOOT WALLS Studs supporting one floor, roof and ceiling (first story of a two-story building) 50 ksi steel |
153 | TABLE R603.2.4 SCREW SUBSTITUTION FACTOR |
154 | FIGURE R603.3.5 HOLE PATCH FIGURE R603.3.6 TRACK SPLICE |
155 | FIGURE R603.4 CORNER FRAMING |
156 | TABLE R603.6(1) ALLOWABLE HEADER SPANSa,b Headers supporting roof and ceiling only (33 ksi steel |
157 | TABLE R603.6(2) ALLOWABLE HEADER SPANSa,b Headers supporting one floor, roof and ceiling (33 ksi steel) |
158 | TABLE R603.6(3) ALLOWABLE HEADER SPANSa,b,c Headers supporting one floor, roof and ceiling first story of a two-story building with center load bearing beam (33 ksi steel) |
159 | TABLE R603.6(4) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING TABLE R603.6(5) HEADER TO KING STUD CONNECTION REQUIREMENTSa,b,c,d TABLE R603.7 MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b,c,d,e |
160 | FIGURE R603.6HEADER DETAIL |
161 | SECTION R604 WOOD STRUCTURAL PANELS SECTION R605 PARTICLEBOARD SECTION R606 GENERAL MASONRY CONSTRUCTION |
162 | TABLE R606.4 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY |
163 | TABLE R606.8 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS |
164 | FIGURE R606.10(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF |
165 | FIGURE R606.10(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C |
166 | FIGURE R606.10(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D1 OR D2 |
167 | TABLE R606.11.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D1 |
168 | TABLE R606.11.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 TABLE R606.11.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 |
169 | TABLE R606.14.1MINIMUM CORROSION PROTECTION SECTION R607 UNIT MASONRY TABLE R607.1 MORTAR PROPORTIONSa,b |
170 | SECTION R608 MULTIPLE WYTHE MASONRY |
171 | SECTION R609 GROUTED MASONRY TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS |
172 | FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE |
173 | SECTION R610 GLASS UNIT MASONRY |
174 | SECTION R611 INSULATING CONCRETE FORMWALL CONSTRUCTION TABLE R611.2 REQUIREMENTS FOR ICF WALLSa,b,c FIGURE R611.3 FLAT ICF WALL SYSTEM |
175 | TABLE R611.3(1) DESIGN WIND PRESSURE FOR USE WITH TABLES R611.3(2), R611.4(1), AND R611.5 FOR ABOVE GRADE WALLSa |
176 | TABLE R611.3(2) MINIMUM VERTICAL WALL REINFORCEMENT FOR FLAT ICF ABOVE-GRADE WALLSa,b,c,d |
177 | FIGURE R611.4 WAFFLE-GRID ICF WALL SYSTEM |
178 | TABLE R611.4(1) MINIMUM VERTICAL WALL REINFORCEMENT FOR WAFFLE-GRID ICF ABOVE-GRADE WALLSa, b, c TABLE R611.4(2) DIMENSIONAL REQUIREMENTS FOR CORES AND WEBS INWAFFLE-GRID AND SCREEN-GRID ICF WALLSa,b |
179 | TABLE R611.5 MINIMUM VERTICAL WALL REINFORCEMENT FOR SCREEN-GRID ICF ABOVE-GRADE WALLSa,b,c FIGURE R611.5 SCREEN-GRID IFC WALL SYSTEM |
180 | TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS |
181 | TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa,b,c,d,f NO. 4 BOTTOM BAR SIZE |
182 | TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa,b,c,d,f NO. 5 BOTTOM BAR SIZE |
183 | TABLE R611.7(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d,f NO. 4 BOTTOM BAR SIZE |
184 | TABLE R611.7(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d,f NO. 5 BOTTOM BAR SIZE |
185 | TABLE R611.7(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa,b,c,d,e,f,g NO. 4 BOTTOM BAR SIZE TABLE R611.7(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa,b,c,d,e,f,g NO. 5 BOTTOM BAR SIZE |
186 | TABLE R611.7(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS WITHOUT STIRRUPS IN LOAD-BEARING WALLSa,b,c,d,e,f,g,h (NO. 4 OR NO. 5) BOTTOM BAR SIZE |
187 | TABLE R611.7(9) MINIMUM BOTTOM BAR ICF LINTEL REINFORCEMENT FOR LARGE CLEAR SPANS IN LOAD-BEARING WALLSa,b,c,d,e,f,h |
188 | TABLE R611.7(9A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c |
189 | TABLE R611.7(9B) MINIMUM SOLID SIDEWALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PARALLEL TO RIDGE) a, b, c, d |
190 | TABLE R611.7(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS IN NON-LOAD-BEARING WALLS WITHOUT STIRRUPSa, b, c, d NO. 4 BOTTOM BAR |
191 | TABLE R611.7(10A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c |
192 | TABLE R611.7(10A)—continued MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c TABLE R611.7(10B) MINIMUM SOLID SIDE WALL LENGTH REQUIREMENTS FOR 6-INCH WAFFLE AND SCREEN-GRID ICF WALLS (WIND PARALLEL TO RIDGE)a,b,c,d |
193 | TABLE R611.7(11) MINIMUM PERCENTAGE OF SOLID WALL LENGTH ALONG EXTERIOR WALL LINES FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY Da,b FIGURE R611.7(1) ICF WALL CONSTRUCTION |
194 | FIGURE R611.7(2) REINFORCEMENT OF OPENINGS FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN-GRID WALLS |
195 | FIGURE R611.7(4) SINGLE FORM HEIGHT WAFFLE-GRID LINTEL FIGURE R611.7(5) DOUBLE FORM HEIGHT WAFFLE-GRID LINTEL |
196 | FIGURE R611.7(6) SINGLE FORM HEIGHT SCREEN-GRID LINTEL FIGURE R611.7(7) DOUBLE FORM HEIGHT SCREEN-GRID LINTEL |
197 | FIGURE R611.7.1.4 LAP SPLICES |
198 | FIGURE R611.7.4 MINIMUM SOLID WALL LENGTH |
199 | TABLE R611.7.4 WIND VELOCITY PRESSURE FOR DETERMINATION OF MINIMUM SOLID WALL LENGTHa |
200 | TABLE R611.8(1) FLOOR LEDGER-ICF WALL CONNECTION (SIDE-BEARING CONNECTION) REQUIREMENTSa,b,c TABLE R611.8(2) DESIGN VALUES (PLF) FOR FLOOR JOIST-TO-WALL ANCHORS REQUIRED FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY Da,b |
201 | FIGURE R611.8(1) SECTION CUT THROUGH FLAT WALL OR VERTICAL CORE OF WAFFLE- OR SCREEN-GRID WALL FIGURE R611.8(2) FLOOR LEDGER—ICF WALL CONNECTION (SIDE-BEARING CONNECTION) |
202 | FIGURE R611.8(3) FLOOR LEDGER—ICF WALL CONNECTION (LEDGE-BEARING CONNECTION) FIGURE R611.8(4) WOOD FLOOR LEDGER—ICF WALL SYSTEM CONNECTION (THROUGH-BOLT SIDE-BEARING CONNECTION) |
203 | FIGURE R611.8(5) FLOOR LEDGER—ICF WALL CONNECTION FIGURE R611.8(6) ANCHORAGE REQUIREMENTS FOR TOP BEARING WALLS FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY D FOR FLOOR FRAMING PARALLEL TO WALL |
204 | FIGURE R611.8(7) ANCHORAGE REQUIREMENTS FOR LEDGER BEARING WALLS FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORY D FOR FLOOR FRAMING PARALLEL TO WALL |
205 | TABLE R611.9 DESIGN TENSILE STRENGTH OF HEADED BOLTS CAST IN CONCRETEa FIGURE R611.9ROOF SILL PLATE—ICF WALL CONNECTION |
206 | SECTION R612 CONVENTIONALLY FORMED CONCRETE WALL CONSTRUCTION SECTION R613 EXTERIOR WINDOWS AND GLASS DOORS |
207 | FIGURE R613.5(1) THROUGH THE FRAME FIGURE R613.5(2) FRAME CLIP FIGURE R613.5(3) THROUGH THE FRAME FIGURE R613.5(4) FRAME CLIP |
208 | FIGURE R613.5(5) THROUGH THE FLANGE FIGURE R613.5(6) THROUGH THE FRAME FIGURE R613.5(7) FRAME CLIP FIGURE R613.5(8) THROUGH THE FLANGE |
209 | CHAPTER 7 WALL COVERING SECTION R701 GENERAL SECTION R702 INTERIOR COVERING TABLE R702.1(1) THICKNESS OF PLASTER TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa |
210 | TABLE R702.1(3) PORTLAND CEMENT PLASTER |
211 | TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD |
212 | SECTION R703 EXTERIOR COVERING |
213 | TABLE R703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS |
214 | TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa,b,c (Dimensions are in inches) |
216 | FIGURE R703.7 MASONRY VENEER WALL DETAILS |
217 | FIGURE R703.7—continued MASONRY VENEER WALL DETAILS |
218 | FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES |
219 | FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS TABLE R703.7.3 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa,b,c |
221 | CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL SECTION R802 WOOD ROOF FRAMING |
224 | TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240) |
225 | TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240) |
226 | TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240) |
227 | TABLE R802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240) |
228 | TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180) |
229 | TABLE R802.5.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180) |
230 | TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240) |
231 | TABLE R802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240) |
232 | TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180) |
233 | TABLE R802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180) |
234 | TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling not attached to rafters, L/Δ = 180) |
235 | TABLE R802.5.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling not attached to rafters, L/Δ = 180) |
236 | TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240) |
237 | TABLE R802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240) |
238 | TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling attached to rafters, L/Δ = 240) |
239 | TABLE R802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf or less, ceiling attached to rafters, L/Δ = 240) |
240 | TABLE R802.5.1(7) RAFTER SPANS COMMON LUMBER SPECIES (Ground snow load=70 psf or less, ceiling not attached to rafters, L/Δ = 180) |
241 | TABLE R802.5.1(7)—continued RAFTER SPANS COMMON LUMBER SPECIES(Ground snow load=70 psf or less, ceiling not attached to rafters, L/Δ = 180) |
242 | TABLE R802.5.1(8) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 70 psf or less, ceiling attached to rafters, L/D=240) |
243 | TABLE R802.5.1(8) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 70 psf or less, ceiling attached to rafters, L/D=240) |
244 | TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa,b,c,d,e,f |
245 | FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION |
246 | TABLE R802.11REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCESa,b,c,e,f(Pounds per connection) |
247 | SECTION R803 ROOF SHEATHING TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING SECTION R804 STEEL ROOF FRAMING |
248 | TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL ROOF FRAMING MEMBERS FIGURE R804.2(1) C-SECTION FIGURE R804.2(2) TRACK SECTION FIGURE R804.2(3) WEB HOLES |
249 | TABLE R804.2.4 SCREW SUBSTITUTION FACTOR |
250 | TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa,b FIGURE R804.3 STEEL ROOF CONSTRUCTION |
251 | TABLE R804.3.1(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL CEILING JOISTSa,b,c 10 psf live load (no attic storage) TABLE R804.3.1(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL CEILING JOISTSa,b,c 20 psf live load (Limited attic storage where development of future rooms is not possible) |
252 | TABLE R804.3.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO RAFTER CONNECTIONa FIGURE R804.3.1(1) JOIST TO RAFTER CONNECTION |
253 | TABLE R804.3.3(1) ALLOWABLE HORIZONTAL RAFTER SPANSa,b TABLE R804.3.3(2) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION TABLE R804.3.3.1 NUMBER OF SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR RAFTER TO RIDGE MEMBER CONNECTIONa |
254 | FIGURE R804.3.3.1 RIDGE BOARD CONNECTION |
255 | FIGURE R804.3.6 HOLE PATCHING FIGURE R804.3.7(1) SPLICED CEILING JOISTS |
256 | FIGURE R804.3.7(2) TRACK SPLICE FIGURE R804.3.8 BEARING STIFFENER |
257 | FIGURE R804.3.10(1) ROOF OPENING FIGURE R804.3.10(2)HEADER TO TRIMMER CONNECTION |
258 | SECTION R805 CEILING FINISHES SECTION R806 ROOF VENTILATION SECTION R807 ATTIC ACCESS SECTION R808 INSULATION CLEARANCE |
259 | CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL SECTION R902 ROOF CLASSIFICATION SECTION R903 WEATHER PROTECTION SECTION R904 MATERIALS SECTION R905 REQUIREMENTS FOR ROOF COVERINGS |
261 | TABLE R905.2.8.2 VALLEY LINING MATERIAL |
262 | TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT |
263 | TABLE R905.6.5 SLATE SHINGLE HEADLAP TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
264 | TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE |
265 | TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS |
266 | TABLE R905.10.3 METAL ROOF COVERINGS STANDARDS AND INSTALLATION TABLE R905.11.2MODIFIED BITUMEN ROOFING MATERIAL STANDARDS |
267 | SECTION R906 ROOF INSULATION SECTION R907 REROOFING |
269 | CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY CHIMNEYS |
270 | TABLE R1001.11(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZESa TABLE R1001.11(2) NET CROSS–SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZESa |
271 | FIGURE R1001.12.2 FLUE SIZES FOR MASONRY CHIMNEYS |
272 | FIGURE R1001.15 CLEARANCE FROM COMBUSTIBLES FIGURE R1001.17 CHIMNEY CRICKET |
273 | TABLE R1001.17 CRICKET DIMENSIONS SECTION R1002 FACTORY-BUILT CHIMNEYS SECTION R1003 MASONRY FIREPLACES |
274 | TABLE R1003.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS |
275 | FIGURE R1003.1 FIREPLACE AND CHIMNEY DETAILS |
277 | SECTION R1004 FACTORY-BUILT FIREPLACES SECTION R1005 EXTERIOR AIR SUPPLY SECTION R1006 MASONRY HEATERS |
278 | FIGURE R1003.12 CLEARANCE FROM COMBUSTIBLES |
279 | PART IV – ENERGY CONSERVATION CHAPTER 11 ENERGY EFFICIENCY SECTION N1101 GENERAL |
280 | TABLE N1101.2 NEW YORK STATE RESIDENTIAL CLIMATE ZONES |
281 | TABLE N1101.5(1) DEFAULT GLAZED FENESTRATION U-FACTOR TABLE N1101.5(2) DEFAULT DOOR U-FACTORS TABLE N1101.5(3) DEFAULT GLAZED FENESTRATION SHGC |
282 | SECTION N1102 BUILDING THERMAL ENVELOPE TABLE N1102.1(1) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa TABLE N1102.1(2) ALTERNATIVE INSULATION REQUIREMENTS BY COMPONENTa (See Section N1102.1 exception 3) TABLE N1102.1.2 EQUIVALENT U-FACTORSa |
283 | TABLE N1102.1.4 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT FOR RESIDENCES USING ELECTRIC RESISTANCE HEATING |
284 | TABLE N1102.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
285 | SECTION N1103 SYSTEMS |
286 | TABLE N1103.7 OPTIONAL MECHANICAL EQUIPMENT EFFICIENCY REQUIREMENTS |
287 | PART V – MECHANICAL CHAPTER 12 MECHANICAL SECTION M1201 GENERAL [EB] SECTION M1202 EXISTING MECHANICAL SYSTEMS |
289 | CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL SECTION M1302 APPROVAL SECTION M1303 LABELING OF APPLIANCES SECTION M1304 TYPE OF FUEL SECTION M1305 APPLIANCE ACCESS |
290 | SECTION M1306 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION FIGURE M1306.1 REDUCED CLEARANCE DIAGRAM |
291 | FIGURE M1306.2 WALL PROTECTOR CLEARANCE REDUCTION SYSTEM |
292 | TABLE M1306.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa,b,c,d,e,f,g,h,i,j,k |
293 | SECTION M1307 APPLIANCE INSTALLATION SECTION M1308 MECHANICAL SYSTEMS INSTALLATION |
295 | CHAPTER 14 HEATING AND COOLING EQUIPMENT SECTION M1401 GENERAL SECTION M1402 CENTRAL FURNACES SECTION M1403 HEAT PUMP EQUIPMENT SECTION M1404 REFRIGERATION COOLING EQUIPMENT SECTION M1405 BASEBOARD CONVECTORS SECTION M1406 RADIANT HEATING SYSTEMS |
296 | SECTION M1407 DUCT HEATERS SECTION M1408 VENTED FLOOR FURNACES SECTION M1409 VENTED WALL FURNACES |
297 | SECTION M1410 VENTED ROOM HEATERS SECTION M1411 REFRIGERATION COOLING EQUIPMENT |
298 | SECTION M1412 ABSORPTION COOLING EQUIPMENT SECTION M1413 EVAPORATIVE COOLING EQUIPMENT SECTION 1414 FIREPLACE (WOOD) STOVES SECTION M1415 MASONRY HEATERS SECTION 1416 KEROSENE AND OIL-FIRED STOVES ANDHEATERS |
299 | CHAPTER 15 EXHAUST SYSTEMS SECTION M1501 CLOTHES DRYERS EXHAUST SECTION M1502 RANGE HOODS SECTION M1503 INSTALLATION OF MICROWAVE OVENS SECTION M1504 OVERHEAD EXHAUST HOODS |
300 | SECTION M1505 EXHAUST DUCTS SECTION M1506 MECHANICAL VENTILATION TABLE M1506.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS |
301 | CHAPTER 16 DUCT SYSTEMS SECTION M1601 DUCT CONSTRUCTION TABLE M1601.1.1(1) CLASSIFICATION OF FACTORY-MADE AIR DUCTS TABLE M1601.1.1(2) GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING |
303 | SECTION M1602 RETURN AIR |
305 | CHAPTER 17 COMBUSTION AIR SECTION M1701 GENERAL SECTION M1702 ALL AIR FROM INSIDE THE BUILDING SECTION M1703 ALL AIR FROM OUTDOORS |
306 | FIGURE M1702.2 APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM ADJACENT SPACES WITHIN THE BUILDING |
307 | FIGURE M1703.2(1) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH TWO OPENINGS FIGURE M1703.2(2) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH HORIZONTAL DUCTS |
308 | FIGURE M1703.2(3) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH VENTILATED ATTIC FIGURE M1703.2(4) APPLIANCES LOCATED IN CONFINED SPACES—INLET AIR TAKEN FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC |
309 | FIGURE M1703.3 APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH VENTILATED ATTIC, INLET DUCT WITHIN OUTLET DUCT |
311 | CHAPTER 18 CHIMNEYS AND VENTS SECTION M1801 GENERAL SECTION M1802 VENT COMPONENTS |
312 | SECTION M1803 CHIMNEY AND VENT CONNECTORS TABLE M1803.2 THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS TABLE M1803.3.4 CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa |
313 | SECTION M1804 VENTS TABLE M1804.1 VENT SELECTION CHART SECTION M1805 MASONRY AND FACTORY-BUILT CHIMNEYS |
315 | CHAPTER 19 SPECIAL FUEL-BURNING EQUIPMENT SECTION M1901 COOKING APPLIANCES SECTION M1902 SAUNA HEATERS SECTION M1903 STATIONARY FUEL CELL POWER PLANTS |
317 | CHAPTER 20 BOILERS AND WATER HEATERS SECTION M2001 BOILERS SECTION M2002 OPERATING AND SAFETY CONTROLS SECTION M2003 EXPANSION TANKS SECTION M2004 WATER HEATERS USED FOR SPACE HEATING SECTION M2005 WATER HEATERS |
318 | TABLE M2003.2 EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT–WATER SYSTEMS SECTION M2006 POOL HEATERS |
319 | CHAPTER 21 HYDRONIC PIPING SECTION M2101 HYDRONIC PIPING SYSTEMS INSTALLATION TABLE M2101.1 HYDRONIC PIPING MATERIALS |
320 | TABLE M2101.9 HANGER SPACING INTERVALS SECTION M2102 BASEBOARD CONVECTORS SECTION M2103 FLOOR HEATING SYSTEMS |
321 | SECTION M2104 LOW TEMPERATURE PIPING SECTION M2105 GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING |
323 | CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS SECTION M2201 OIL TANKS SECTION M2202 OIL PIPING, FITTING AND CONNECTIONS SECTION M2203 INSTALLATION |
324 | SECTION M2204 OIL PUMPS AND VALVES |
325 | CHAPTER 23 SOLAR SYSTEMS SECTION M2301 SOLAR ENERGY SYSTEMS |
327 | PART VI – FUEL GAS CHAPTER 24 FUEL GAS SECTION G2401 (101) GENERAL SECTION G2402 (201) GENERAL SECTION G2403 (202) DEFINITIONS SECTION G2404 (301) GENERAL REGULATIONS |
328 | SECTION G2405 (302) STRUCTURAL SAFETY SECTION G2406 (303) APPLIANCE LOCATION SECTION G2407 (304) COMBUSTION, VENTILATION AND DILUTION AIR |
329 | (EQUATION 24-1) (EQUATION 24-2) FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING (see Section G2407.5.3) |
330 | FIGURE G2407.6.1(1) [304.6.1(1)] ALL AIR FROM OUTDOOR—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section G2407.6.1) |
331 | FIGURE G2407.6.1(2) [304.6.1(2) ]ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section G2407.6.1) FIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS (see Section G2407.6.1) |
332 | FIGURE G2407.6.2 (304.6.2) SINGLE COMBUSTION AIR OPENING—ALL AIR FROM OUTDOORS (see Section G2407.6.2.) |
333 | SECTION G2408 (305) INSTALLATION SECTION G2409 (308) CLEARANCE REDUCTION |
334 | TABLE G2409.2 (308.2) REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa,b,c,d,e,f,g,h,i,j,k |
335 | FIGURE G2409.2(1) [308.2(1)] EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTORS FIGURE G2409.2(2) [308.2(2)] WALL PROTECTOR CLEARANCE REDUCTION SYSTEM |
336 | SECTION G2410 (309) ELECTRICAL SECTION G2411 (310) ELECTRICAL BONDING SECTION G2412 (401) GAS PIPING SYSTEMS |
337 | SECTION G2413 (402) PIPE SIZING TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES |
338 | (EQUATION 24-3) (EQUATION 24-4) TABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS SECTION G2414 (403) PIPING MATERIALS |
339 | TABLE G2413.4(1) [402.4(2) ]SCHEDULE 40 METALLIC PIPE TABLE G2413.4(2) [402.4(3)] SCHEDULE 40 METALLIC PIPE |
340 | TABLE G2413.4(3) [402.4(8)] SEMI-RIGID COPPER TUBING |
341 | TABLE G2413.4(4) [402.4(11)] SEMI-RIGID COPPER TUBING |
342 | TABLE G2413.4(5) [402.4(14)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
343 | TABLE G2413.4(6) [402.4(17)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
344 | TABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE |
345 | SECTION G2415 (404) PIPING SYSTEM INSTALLATION |
346 | SECTION G2416 (405) PIPING BENDS AND CHANGES IN DIRECTION |
347 | SECTION G2417 (406) INSPECTION, TESTING AND PURGING |
348 | SECTION G2418 (407) PIPING SUPPORT SECTION G2419 (408) DRIPS AND SLOPED PIPING SECTION G2420 (409) GAS SHUTOFF VALVES |
349 | SECTION G2421 (410 )FLOW CONTROLS SECTION G2422 (411) APPLIANCE CONNECTIONS |
350 | SECTION G2423 (413) CNG GAS-DISPENSING SYSTEMS SECTION G2424 (415) PIPING SUPPORT INTERVALS TABLE G2424.1 SUPPORT OF PIPING SECTION G2425 (501) CHIMNEYS AND VENTS |
351 | SECTION G2426 (502) VENTS |
352 | SECTION G2427 (503) VENTING OF EQUIPMENT |
353 | TABLE G2427.4 (503.4) TYPE OF VENTING SYSTEM TO BE USED |
354 | FIGURE G2427.5.3 (503.5.4) TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES |
356 | FIGURE G2427.6.5 (503.6.6) GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL |
357 | TABLE G2427.7.7 (503.7.7) CLEARANCES FOR CONNECTORS |
358 | FIGURE G2427.8 |
359 | TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES |
361 | SECTION G2428 (504) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS |
363 | TABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT |
364 | TABLE G2428.2(1) [504.2(1)]—continued TYPE B DOUBLE-WALL GAS VENT |
365 | TABLE G2428.2(2) [504.2(2)] TYPE B DOUBLE-WALL GAS VENT |
366 | TABLE G2428.2(2) [504.2(2)—continued] TYPE B DOUBLE-WALL GAS VENT |
367 | TABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT |
368 | TABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL VENT |
369 | TABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY |
370 | TABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY |
371 | TABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH |
372 | SECTION G2429 (505) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING SECTION G2430 (506) FACTORY-BUILT CHIMNEYS |
373 | SECTION G2431 (601) SPECIFIC APPLIANCES SECTION G2432 (602) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES SECTION G2433 (603) LOG LIGHTERS SECTION G2434 (604) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS SECTION G2436 (608) VENTED WALL FURNACES SECTION G2437 (609) FLOOR FURNACES |
374 | SECTION G2438 (613) CLOTHES DRYERS SECTION G2439 (614) CLOTHES DRYER EXHAUST SECTION G2440 (615) SAUNA HEATERS |
375 | SECTION G2441 (617) POOL AND SPA HEATERS SECTION G2442 (618) FORCED-AIR WARM-AIR FURNACES |
376 | SECTION G2443 (619) CONVERSION BURNERS SECTION G2444 (620) UNIT HEATERS SECTION G2445 (621) UNVENTED ROOM HEATERS SECTION G2446 (622) VENTED ROOM HEATERS |
377 | SECTION G2447 (623) COOKING APPLIANCES SECTION G2448 (624) WATER HEATERS SECTION G2449 (627) AIR CONDITIONING EQUIPMENT SECTION G2450 (628) ILLUMINATING APPLIANCES SECTION G2451 (630) INFRARED RADIANT HEATERS |
378 | SECTION G2452 (631) BOILERS SECTION G2453 (634) CHIMNEY DAMPER OPENING AREA TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES SECTION G2454 (633) STATIONARY FUEL CELL POWER PLANTS |
379 | PART VII – PLUMBING CHAPTER 25 PLUMBING SECTION P2501 GENERAL [EB] SECTION P2502 EXISTING PLUMBING SYSTEMS SECTION P2503 INSPECTION AND TESTS |
381 | CHAPTER 26 GENERAL PLUMBING REQUIREMENTS SECTION P2601 GENERAL SECTION P2602 INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SECTION P2603 STRUCTURAL AND PIPING PROTECTION |
382 | SECTION P2604 TRENCHING AND BACKFILLING FIGURE P2604.4 PIPE LOCATION WITH RESPECT TO FOOTINGS SECTION P2605 SUPPORT SECTION P2606 WATERPROOFING OF OPENINGS |
383 | TABLE P2605.1 PIPING SUPPORT SECTION P2607 WORKMANSHIP SECTION P2608 MATERIALS EVALUATION AND LISTING |
384 | TABLE P2608.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION |
385 | CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS TABLE P2701.1 PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS |
386 | SECTION P2702 FIXTURE ACCESSORIES SECTION P2703 TAIL PIECES SECTION P2704 ACCESS TO CONNECTIONS SECTION P2705 INSTALLATION SECTION P2706 WASTE RECEPTORS SECTION P2707 DIRECTIONAL FITTINGS |
387 | SECTION P2708 SHOWERS SECTION P2709 SHOWER RECEPTORS SECTION P2710 SHOWER WALLS SECTION P2711 LAVATORIES |
388 | SECTION P2712 WATER CLOSETS SECTION P2713 BATHTUBS SECTION P2714 SINKS SECTION P2715 LAUNDRY TUBS SECTION P2716 FOOD WASTE GRINDER SECTION P2717 DISHWASHING MACHINES |
389 | SECTION P2718 CLOTHES WASHING MACHINE SECTION P2719 FLOOR DRAINS SECTION P2720 WHIRLPOOL BATHTUBS SECTION P2721 BIDET INSTALLATIONS SECTION P2722 FIXTURE FITTING SECTION P2723 MACERATING TOILET SYSTEMS SECTION P2724 SPECIALTY TEMPERATURE CONTROL DEVICES AND VALVES |
391 | CHAPTER 28 WATER HEATERS SECTION P2801 GENERAL SECTION P2802 WATER HEATERS USED FOR SPACE HEATING SECTION P2803 RELIEF VALVES |
393 | CHAPTER 29 WATER SUPPLY AND DISTRIBUTION SECTION P2901 GENERAL SECTION P2902 PROTECTION OF POTABLE WATER SUPPLY |
394 | TABLE P2902.2 APPLICATION FOR BACKFLOW PREVENTERS |
395 | SECTION P2903 WATER-SUPPLY SYSTEM TABLE P2903.1 REQUIRED CAPACITIES AT POINT OF OUTLET DISCHARGE TABLE P2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGSb |
396 | TABLE P2903.6 WATER-SUPPLY FIXTURE-UNIT VALUES FOR VARIOUS PLUMBING FIXTURES AND FIXTURE GROUPS |
397 | TABLE P2903.6(1) CONVERSIONS FROM WATER SUPPLY FIXTURE UNIT TO GALLON PER MINUTE FLOW RATES |
399 | TABLE P2903.7 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES |
400 | TABLE P2903.7—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES TABLE P2903.8.1 MANIFOLD SIZING |
401 | FIGURE P2903.10 TYPICAL FROST-PROOF HOSE BIBB INSTALLATION NOT REQUIRING SEPARATE VALUE SECTION P2904 MATERIALS, JOINTS AND CONNECTIONS |
402 | TABLE P2904.4.1 WATER SERVICE PIPEa |
403 | TABLE P2904.5 WATER DISTRIBUTION PIPE TABLE P2904.6 PIPE FITTINGS |
405 | SECTION P2905 CHANGES IN DIRECTION SECTION P2906 SUPPORT SECTION P2907 DRINKING WATER TREATMENT UNITS |
407 | CHAPTER 30 SANITARY DRAINAGE SECTION P3001 GENERAL SECTION P3002 MATERIALS SECTION P3003 JOINTS AND CONNECTIONS |
408 | TABLE P3002.1 DRAIN, WASTE AND VENT PIPING AND FITTING MATERIALS |
409 | TABLE P3002.2 BUILDING SEWER PIPING AND FITTINGS |
410 | SECTION P3004 DETERMINING DRAINAGE FIXTURE UNITS SECTION P3005 DRAINAGE SYSTEM |
411 | TABLE P3004.1 DRAINAGE FIXTURE UNIT (d.f.u.) VALUES FOR VARIOUS PLUMBING FIXTURES |
412 | TABLE P3005.1 FITTINGS FOR CHANGE IN DIRECTION |
413 | TABLE P3005.2.9 CLEANOUTS TABLE P3005.4.1 MAXIMUM FIXTURE UNITS ALLOWED TO BE CONNECTED TO BRANCHES AND STACKS TABLE P3005.4.2 MAXIMUM NUMBER OF FIXTURE UNITS ALLOWED TO BE CONNECTED TO THE BUILDING DRAIN, BUILDING DRAIN BRANCHES OR THE BUILDING SEWER |
414 | SECTION P3006 SIZING OF DRAIN PIPE OFFSETS SECTION P3007 SUMPS AND EJECTORS SECTION P3008 BACKWATER VALVES |
415 | CHAPTER 31 VENTS SECTION P3101 VENT SYSTEMS SECTION P3102 VENT STACKS AND STACK VENTS SECTION P3103 VENT TERMINALS SECTION P3104 VENT CONNECTIONS AND GRADES |
416 | SECTION P3105 FIXTURE VENTS TABLE P3105.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION P3106 INDIVIDUAL VENT SECTION P3107 COMMON VENT |
417 | TABLE P3107.3 COMMON VENT SIZES SECTION P3108 WET VENTING TABLE P3108.3 WET VENT SIZE SECTION P3109 WASTE STACK VENT TABLE P3109.4 WASTE STACK VENT SIZE SECTION P3110 CIRCUIT VENTING |
418 | SECTION P3111 COMBINATION WASTE AND VENT SYSTEM TABLE P3111.3 SIZE OF COMBINATION WASTE AND VENT PIPE SECTION P3112 ISLAND FIXTURE VENTING SECTION P3113 VENT PIPE SIZING |
419 | TABLE P3113.4.1 SIZE AND LENGTH OF SUMP VENTS SECTION P3114 AIR ADMITTANCE VALVES |
420 | FIGURE P3108.1(1) TYPICAL SINGLE-BATH WET-VENT ARRANGEMENTS |
421 | FIGURE P3108.1(2) TYPICAL DOUBLE-BATH WET-VENT ARRANGEMENTS |
422 | FIGURE P3108.1(3) TYPICAL HORIZONTAL WET VENTING |
423 | FIGURE P3108.1(4) TYPICAL METHODS OF WET VENTING |
424 | FIGURE P3108.1(5) SINGLE-STACK SYSTEM FOR A TWO-STORY DWELLING |
425 | FIGURE P3109.2 WET STACK VENTING |
426 | FIGURE P3110.4 CIRCUIT VENT WITH ADDITIONAL NONCIRCUIT VENTED BRANCHES |
427 | CHAPTER 32 TRAPS SECTION P3201 FIXTURE TRAPS TABLE P3201.7 SIZE OF TRAPS AND TRAP ARMS FOR PLUMBING FIXTURES |
429 | PART VIII – ELECTRICAL CHAPTER 33 GENERAL REQUIREMENTS SECTION E3301 GENERAL SECTION E3302 BUILDING STRUCTURE PROTECTION SECTION E3303 APPROVAL SECTION E3304 GENERAL EQUIPMENT REQUIREMENTS |
430 | SECTION E3305 EQUIPMENT LOCATION AND CLEARANCES |
431 | FIGURE E3305.1a,b,c,d,e WORKING SPACE AND CLEARANCES |
432 | SECTION E3306 ELECTRICAL CONDUCTORS AND CONNECTIONS SECTION E3307 CONDUCTOR AND TERMINAL IDENTIFICATION |
435 | CHAPTER 34 ELECTRICAL DEFINITIONS SECTION E3401 GENERAL |
439 | CHAPTER 35 SERVICES SECTION E3501 GENERAL SERVICES SECTION E3502 SERVICE SIZE AND RATING TABLE E3502.2 MINIMUM SERVICE LOAD CALCULATION |
440 | SECTION E3503 SERVICE, FEEDER AND GROUNDING ELECTRODE CONDUCTOR SIZING TABLE E3503.1 SERVICE CONDUCTOR AND GROUNDING ELECTRODE CONDUCTOR SIZING |
441 | SECTION E3504 OVERHEAD SERVICE-DROP AND SERVICE CONDUCTOR INSTALLATION FIGURE E3504.1 CLEARANCES FROM BUILDING OPENINGS |
442 | FIGURE E3504.2.1 CLEARANCES FROM ROOFS |
443 | SECTION E3505 SERVICE-ENTRANCE CONDUCTORS SECTION E3506 SERVICE EQUIPMENT—GENERAL |
444 | SECTION E3507 SYSTEM GROUNDING SECTION E3508 GROUNDING ELECTRODE SYSTEM |
445 | SECTION E3509 BONDING |
446 | SECTION E3510 GROUNDING ELECTRODE CONDUCTORS SECTION E3511 GROUNDING ELECTRODE CONDUCTOR CONNECTION TO THE GROUNDING ELECTRODES |
449 | CHAPTER 36 BRANCH CIRCUIT AND FEEDER REQUIREMENTS SECTION E3601 GENERAL SECTION E3602 BRANCH CIRCUIT RATINGS |
450 | TABLE E3602.13 BRANCH-CIRCUIT REQUIREMENTS—SUMMARYa,b SECTION E3603 REQUIRED BRANCH CIRCUITS |
451 | SECTION E3604 FEEDER REQUIREMENTS TABLE E3604.3(1) FEEDER LOAD CALCULATION |
452 | TABLE E3604.3(2) DEMAND LOADS FOR ELECTRIC RANGES, WALL-MOUNTED OVENS, COUNTER-MOUNTED COOKING UNITS AND OTHER COOKING APPLIANCES OVER 13/4 kVA RATINGa,b SECTION E3605 CONDUCTOR SIZING AND OVERCURRENT PROTECTION TABLE E3605.1 ALLOWABLE AMPACITIES |
453 | TABLE E3605.2 AMBIENT TEMPERATURE CORRECTION FACTORS TABLE E3605.3 CONDUCTOR PROXIMITY ADJUSTMENT FACTORS |
454 | TABLE E3605.5.3 OVERCURRENT-PROTECTION RATING |
455 | SECTION E3606 PANELBOARDS |
457 | CHAPTER 37 WIRING METHODS SECTION E3701 GENERAL REQUIREMENTS TABLE E3701.2 ALLOWABLE WIRING METHODS SECTION E3702 ABOVE-GROUND INSTALLATION REQUIREMENTS |
458 | TABLE E3701.4 ALLOWABLE APPLICATIONS FOR WIRING METHODSa,b,c,d,e,f,g,h,i |
459 | TABLE E3702.1 GENERAL INSTALLATION AND SUPPORT REQUIREMENTS FOR WIRING METHODSa,b,c,d,e,f,g,h,i |
460 | SECTION E3703 UNDERGROUND INSTALLATION REQUIREMENTS TABLE E3703.1 MINIMUM COVER REQUIREMENTS, BURIAL IN INCHESa,b,c,d |
463 | CHAPTER 38 POWER AND LIGHTING DISTRIBUTION SECTION E3801 RECEPTACLE OUTLETS FIGURE E3801.2 GENERAL USE RECEPTACLE DISTRIBUTION |
464 | FIGURE E3801.4 COUNTERTOP RECEPTACLES |
465 | SECTION E3802 GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION SECTION E3803 LIGHTING OUTLETS |
466 | SECTION E3804 GENERAL INSTALLATION REQUIREMENTS SECTION E3805 BOXES, CONDUIT BODIES AND FITTINGS |
467 | TABLE E3804.6(1) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METALLIC TUBING (EMT)a |
468 | TABLE E3804.6(2) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL NONMETALLIC TUBING (ENT)a |
469 | TABLE E3804.6(3) MAXIMUM NUMBER OF CONDUCTORS IN FLEXIBLE METALLIC CONDUIT (FMC)a |
470 | TABLE E3804.6(4) MAXIMUM NUMBER OF CONDUCTORS IN INTERMEDIATE METALLIC CONDUIT (IMC)a |
471 | TABLE E3804.6(5) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-B)a |
472 | TABLE E3804.6(6) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-A)a |
473 | TABLE E3804.6(7) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC)a |
474 | TABLE E3804.6(8) MAXIMUM NUMBER OF CONDUCTORS IN RIGID METAL CONDUIT (RMC)a |
475 | TABLE E3804.6(9) MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT, SCHEDULE 80 (PVC-80)a |
476 | TABLE E3804.6(10)MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT SCHEDULE 40 (PVC-40)a |
478 | TABLE E3805.12.1 MAXIMUM NUMBER OF CONDUCTORS IN METAL BOXESa TABLE E3805.12.2.1 VOLUME ALLOWANCE REQUIRED PER CONDUCTOR |
479 | SECTION E3806 INSTALLATION OF BOXES, CONDUITBODIES AND FITTINGS |
480 | SECTION E3807 CABINETS AND PANELBOARDS |
481 | SECTION E3808 GROUNDING |
482 | TABLE E3808.12 EQUIPMENT GROUNDING CONDUCTOR SIZING |
483 | SECTION E3809 FLEXIBLE CORDS |
484 | TABLE E3809.2 MAXIMUM AMPERE LOAD AND OVERCURRENT PROTECTION-DEVICE RATING FOR FLEXIBLE CORDS |
485 | CHAPTER 39 DEVICES AND LUMINAIRES SECTION E3901 SWITCHES SECTION E3902 RECEPTACLES |
486 | TABLE E3902.1.2 RECEPTACLE RATINGS FOR VARIOUS SIZE MULTIOUTLET CIRCUITS SECTION E3903 FIXTURES |
487 | FIGURE E3903.11 CLOSET STORAGE SPACE |
488 | SECTION E3904 LUMINAIRE INSTALLATION SECTION E3905 TRACK LIGHTING |
489 | CHAPTER 40 APPLIANCE INSTALLATION SECTION E4001 GENERAL TABLE E4001.3 FLEXIBLE CORD LENGTH |
490 | TABLE E4001. 5DISCONNECTING MEANS |
491 | CHAPTER 41 SWIMMING POOLS SECTION E4101 GENERAL SECTION E4102 WIRING METHODS FOR POOLS, SPAS, HOT TUBS AND HYDROMASSAGE BATHTUBS |
492 | TABLE E4102.1 ALLOWABLE APPLICATIONS FOR WIRING METHODSa,b,c,d,e,f,g |
493 | SECTION E4103 EQUIPMENT LOCATION AND CLEARANCES |
494 | TABLE E4103.5 OVERHEAD CONDUCTOR CLEARANCES TABLE E4103. 6MINIMUM BURIAL DEPTHS SECTION E4104 BONDING |
495 | SECTION E4105 GROUNDING |
496 | SECTION E4106 EQUIPMENT INSTALLATION |
498 | SECTION E4107 STORABLE SWIMMING POOLS SECTION E4108 SPAS AND HOT TUBS |
499 | SECTION E4109 HYDROMASSAGE BATHTUBS |
501 | CHAPTER 42 CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS SECTION E4201 GENERAL SECTION E4202 POWER SOURCES SECTION E4203 WIRING METHODS TABLE E4203.2 CABLE USES AND PERMITTED SUBSTITUTIONS SECTION E4204 INSTALLATION REQUIREMENTS |
503 | PART IX – REFERENCED STANDARDS CHAPTER 43 REFERENCED STANDARDS AAMA ACI ACCA AFPA |
504 | AHA AISI AITC ANSI |
505 | APA ASCE |
506 | ASHRAE ASME |
507 | ASSE ASTM |
513 | AWPA AWWA CDA |
514 | CGSB CISPI CPSC CSA |
515 | CSSB DOC DOTn FEMA |
516 | FM GA HUD HPVA IAS ICC |
517 | MSS NAIMA NCMA NCSBCS NFPA |
518 | NFRC NSF NYSDEC NYSDH RMA |
519 | SAE SMACNA TMS TPI UL |
520 | ULC WDMA |
521 | PART X – APPENDICES APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING |
522 | TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
523 | TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
524 | TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(21) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60 |
526 | USE OF SIZING EQUATION TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES TABLE A.5.2 COPPER TUBE STANDARD SIZES |
527 | TABLE A.5.2 COPPER TUBE STANDARD SIZES — CONTINUED FIGURE A.6 (a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC) |
528 | FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above) |
529 | FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM |
530 | FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM FIGURE A.7.4PIPING PLAN SHOWING A MODIFICATIONTO EXISTING PIPING SYSTEM |
533 | APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR |
534 | FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT HOOD-EQUIPPED APPLIANCE FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR |
535 | FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT HOOD-EQUIPPED APPLIANCES |
536 | FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR FIGURE B-12 USE OF OFFSET COMMON VENT FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM FIGURE B-14 MULTISTORY VENT SYSTEMS |
537 | FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT HOOD-EQUIPPED APPLIANCE FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE |
538 | FIGURE B-17 (EXAMPLE 3) COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES |
539 | FIGURE B-18 (EXAMPLE 4) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT |
540 | TABLE B-1MASONRY CHIMNEY LINER DIMENSIONSWITH CIRCULAR EQUIVALENTS |
541 | APPENDIX C PLUMBING SANITARY DRAINAGE FILTERS FIGURE 706.3(1) COMPARISON OF DIFFERENT 11/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIALS |
542 | FIGURE 706.3(2) COMPARISON OF 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIALS |
543 | FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS |
544 | FIGURE 706.3(3)BDRAINAGE PATTERN FITTINGS |
545 | FIGURE 706.3(4) DIFFERENCE BETWEEN PVC PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT FIGURE 706.3(5) BACK-TO-BACK BLOWOUT FIXTURES FIGURE 706.3(6) HEEL INLET FITTINGS |
546 | FIGURE 706.3(7) COMBINATION TEES FIGURE 706.3(8) FITTING USES |
547 | APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION |
549 | APPENDIX E MANUFACTURED HOUSING USED AS DWELLINGS SECTION AE101 SCOPE SECTION AE102 APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT |
550 | SECTION AE201 DEFINITIONS SECTION AE301 RESERVED SECTION AE302 RESERVED SECTION AE303 RESERVED SECTION AE304 RESERVED SECTION AE305 RESERVED SECTION AE306 RESERVED SECTION AE307 RESERVED SECTION AE401 OCCUPANCY CLASSIFICATION |
551 | SECTION AE402 LOCATION ON PROPERTY SECTION AE501 DESIGN SECTION AE502 FOUNDATION SYSTEMS SECTION AE503 SKIRTING AND PERIMETER ENCLOSURES |
552 | SECTION AE504 STRUCTURAL ADDITIONS SECTION AE505 BUILDING SERVICE EQUIPMENT SECTION AE506 EXITS SECTION AE507 OCCUPANCY, FIRE SAFETY AND ENERGY CONSERVATION STANDARDS SECTION AE600 SPECIAL REQUIREMENTS FOR FOUNDATION SYSTEMS SECTION AE601 FOOTINGS AND FOUNDATIONS SECTION AE602 PIER CONSTRUCTION SECTION AE603 HEIGHT OF PIERS |
553 | SECTION AE604 ANCHORAGE INSTALLATIONS SECTION AE605 TIES, MATERIALS AND INSTALLATION |
554 | SECTION AE606 REFERENCED STANDARDS |
555 | APPENDIX F RESERVED |
557 | APPENDIX G SWIMMING POOLS, SPAS AND HOT TUB SECTION AG101 GENERAL SECTION AG102 DEFINITIONS SECTION AG103 SWIMMING POOLS SECTION AG104 SPAS AND HOT TUBS SECTION AG105 BARRIER REQUIREMENTS |
558 | SECTION AG106 ENTRAPMENT PROTECTION FOR SWIMMING POOL AND SPA SUCTION OUTLETS |
559 | SECTION AG107 ABBREVIATIONS SECTION AG108 STANDARDS |
561 | APPENDIX H PATIO COVERS SECTION AH101 GENERAL SECTION AH102 DEFINITION SECTION AH103 PERMITTED USES SECTION AH104 DESIGN LOADS SECTION AH105 LIGHT AND VENTILATION/EMERGENCY EGRESS SECTION AH106 FOOTINGS SECTION AH107 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS |
562 | TABLE AH107.4(1) DESIGN WIND PRESSURES FOR ALUMINUM SCREEN ENCLOSURE FRAMING WITH AN IMPORTANCE FACTOR OF 0.77a, b, c TABLE AH107.4(2) HEIGHT ADJUSTMENT FACTORS |
563 | APPENDIX I RESERVED |
565 | APPENDIX J EXISTING BUILDINGS AND STRUCTURES SECTION AJ1 ADMINISTRATION SECTION AJ101 PURPOSE AND INTENT SECTION AJ102 COMPLIANCE SECTION AJ103 APPLICABILITY |
566 | SECTION AJ104 ENERGY EFFICIENCY SECTION AJ105 PRELIMINARY MEETING SECTION AJ106 BUILDING EVALUATION SECTION AJ2 DEFINITIONS SECTION AJ201 GENERAL SECTION AJ202 GENERAL DEFINITIONS |
567 | SECTION AJ3 CLASSIFICATION OF WORK SECTION AJ301 GENERAL SECTION AJ302 REPAIRS SECTION AJ303 ALTERATIONS – LEVEL 1 |
568 | SECTION AJ304 ALTERATIONS – LEVEL 2 SECTION AJ305 CHANGE OF OCCUPANCY SECTION AJ306 ADDITIONS SECTION AJ307 HISTORIC BUILDINGS SECTION AJ308 RELOCATED BUILDINGS SECTION AJ309 REPLACEMENT SECTION AJ4 REPAIRS SECTION AJ401 GENERAL SECTION AJ402 BUILDING ELEMENTS AND MATERIALS SECTION AJ403 FIRE AND LIFE SAFETY PROTECTION |
569 | SECTION AJ404 STRUCTURAL SECTION AJ405 MECHANICAL SECTION AJ406 PLUMBING SECTION AJ407 ELECTRICAL |
570 | SECTION AJ5 ALTERATIONS – LEVEL 1 SECTION AJ501 GENERAL SECTION AJ502 BUILDING ELEMENTS AND MATERIALS SECTION AJ503 MEANS OF EGRESS |
571 | SECTION AJ504 FIRE AND LIFE-SAFETY PROTECTION SECTION AJ505 STRUCTURAL AJ506 MECHANICAL AJ507 PLUMBING AJ508 ELECTRICAL SECTION AJ6 ALTERATIONS – LEVEL 2 SECTION AJ601 GENERAL |
572 | SECTION AJ602 BUILDING ELEMENTS AND MATERIALS SECTION AJ603 MEANS OF EGRESS SECTION AJ604 FIRE AND LIFE-SAFETY PROTECTION |
573 | SECTION AJ605 STRUCTURAL SECTION AJ606 MECHANICAL SECTION AJ607 PLUMBING SECTION AJ608 ELECTRICAL |
574 | SECTION AJ7 CHANGE OF OCCUPANCY SECTION AJ701 GENERAL SECTION AJ702 COMPLIANCE SECTION AJ703 FIRE AND LIFE-SAFETY PROTECTION SECTION AJ704 BED AND BREAKFAST DWELLINGS |
575 | SECTION AJ8 ADDITIONS SECTION AJ801 GENERAL SECTION AJ802 FIRE AND LIFE-SAFETY PROTECTION SECTION AJ803 STRUCTURAL |
576 | SECTION AJ804 MECHANICAL SECTION AJ805 PLUMBING SECTION AJ806 ELECTRICAL SECTION AJ9 HISTORIC BUILDINGS SECTION AJ901 GENERAL SECTION AJ902 FIRE AND-LIFE SAFETY PROTECTION |
577 | SECTION AJ903 BUILDING ELEMENTS AND MATERIALS SECTION AJ904 STRUCTURAL SECTION AJ905 REPAIRS SECTION AJ906 ALTERATIONS SECTION AJ907 CHANGE OF OCCUPANCY SECTION AJ908 RELOCATED BUILDINGS |
578 | SECTION AJ10 RELOCATED OR MOVED BUILDINGS SECTION AJ1001 GENERAL SECTION AJ1002 BUILDING ELEMENTS AND MATERIALS SECTION AJ1003 FIRE AND LIFE SAFETY PROTECTION SECTION AJ1004 STRUCTURAL SECTION AJ11 REPLACEMENT SECTION AJ1101 GENERAL |
579 | APPENDIX K SOUND TRANSMISSION SECTION AK101 GENERAL SECTION AK102 AIRBORNE SOUND SECTION AK103 STRUCTURAL-BORNE SOUND SECTION AK104 REFERENCED STANDARDS |
581 | APPENDIX L ICC INTERNATIONAL RESIDENTIAL CODE ELECTRICAL PROVISIONS/NATIONAL ELECTRICAL CODE CROSS-REFERENCE |
593 | INDEX |