Shopping Cart

No products in the cart.

NY StateEnergyCode 2020

$29.25

Energy Conservation Construction Code of New York State

Published By Publication Date Number of Pages
NY 2020 173
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2018 International Energy Conservation Code.

PDF Catalog

PDF Pages PDF Title
1 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE
2 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE TITLE PAGE
3 COPYRIGHT
4 ACKNOWLEDGMENTS
6 PREFACE
8 EFFECTIVE USE OF THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE
12 TABLE OF CONTENTS
14 ECCCNYS—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
16 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
[NY] SECTION C101 SCOPE AND GENERAL REQUIREMENTS
17 [NY] SECTION C102 APPLICABILITY
18 [NY] SECTION C103 INTERPRETATIONS OF ENERGY CODE REQUIREMENTS
19 [NY] SECTION C104 ALTERNATIVE MATERIALS, DESIGNS, METHODS OF CONSTRUCTION AND INSULATING SYSTEMS
SECTION C105 CONSTRUCTION DOCUMENTS
20 [NY] SECTION C106 INSPECTIONS
22 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
30 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
[NY] TABLE C301.1 NEW YORK STATE CLIMATE ZONES BY COUNTY
[NY] TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
31 TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
32 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
33 EQUATION 4-1
EQUATION 4-2
34 [NY] TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD
35 [NY] TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD
36 TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
37 EQUATION 4-3
38 TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
[NY] TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-4
39 EQUATION 4-5
41 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
42 SECTION C403 BUILDING MECHANICAL SYSTEMS
43 EQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY
TABLE C403.3.4 BOILER TURNDOWN
44 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
45 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
46 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
47 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
48 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
49 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
50 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
51 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
52 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
53 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT
55 [NY] TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS
56 [NY] TABLE C403.5(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
[NY] TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
57 TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
60 [NY] TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
[NY] TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
61 TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
62 TABLE C403.8.1(1) FAN POWER LIMITATION
63 TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
64 TABLE C403.8.5.1 COOLING SYSTEMS
66 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
67 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
68 TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
69 EQUATION 4-8
70 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a,
SECTION C404 SERVICE WATER HEATING (MANDATORY)
72 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
73 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
74 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
76 EQUATION 4-9
78 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
79 EQUATION 4-10
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
80 EQUATION 4-11
81 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
82 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
83 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
84 SECTION C406 ADDITIONAL EFFICIENCY PACKAGES
85 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
86 TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
87 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b
88 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
89 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C407 TOTAL BUILDING PERFORMANCE
91 SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
92 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
93 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
94 TABLE C407.5.1(2) HVAC SYSTEMS MAP
95 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
96 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
99 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST
100 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
101 SECTION C503 ALTERATIONS
102 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
104 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
105 AMCA
ANSI
APSP
ASHRAE
106 ASME
ASTM
107 CRRC
CSA
CTI
DASMA
DOE
108 ICC
IEEE
IES
109 ISO
NEMA
NFPA
NFRC
SMACNA
UL
110 US-FTC
WDMA
112 APPENDIX CA SOLAR-READY ZONE—COMMERCIAL
SECTION CA101 SCOPE
SECTION CA102 GENERAL DEFINITION
SECTION CA103 SOLAR-READY ZONE
114 INDEX
124 ECCCNYS—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
126 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION
[NY] SECTION R101 SCOPE AND GENERAL REQUIREMENTS
127 [NY] SECTION R102 APPLICABILITY
128 [NY] SECTION R103 INTERPRETATIONS OF ENERGY CODE REQUIREMENTS
[NY] SECTION R104 ALTERNATIVE MATERIALS, DESIGNS, METHODS OF CONSTRUCTION AND INSULATING SYSTEMS
129 [NY] SECTION R105 CONSTRUCTION DOCUMENTS
[NY] SECTION R106 INSPECTIONS
132 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
136 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
[NY] TABLE R301.1 NEW YORK STATE CLIMATE ZONES BY COUNTY
[NY] TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
137 TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
138 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
139 [NY] TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
[NY] TABLE R402.1.4 EQUIVALENT U-FACTORSa
140 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
143 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
144 SECTION R403 SYSTEMS
146 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYa
147 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
148 [NY] TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
149 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
150 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
152 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
EQUATION 4-1
[NY] TABLE R406.4 MAXIMUM ENERGY RATING INDEX
154 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
155 SECTION R503 ALTERATIONS
SECTION R504 REPAIRS
156 SECTION R505 CHANGE OF OCCUPANCY OR USE
158 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
APSP
ASHRAE
159 ASTM
BOMA
CSA
DASMA
HVI
160 ICC
IEEE
NFPA
161 NFRC
RESNET
UL
US-FTC
WDMA
162 APPENDIX RA SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION RA101 SCOPE
SECTION RA102 GENERAL DEFINITION
SECTION RA103 SOLAR-READY ZONE
164 INDEX
170 HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR ENERGY CODE
171 ICC EVALUATION SERVICE
172 ICC DIGITAL CODES LIBRARY
173 ICC ASSESSMENT CENTER
NY StateEnergyCode 2020
$29.25