NY StateEnergyCode 2020
$29.25
Energy Conservation Construction Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2020 | 173 |
This is a fully integrated custom code based on the 2018 International Energy Conservation Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE |
2 | 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE TITLE PAGE |
3 | COPYRIGHT |
4 | ACKNOWLEDGMENTS |
6 | PREFACE |
8 | EFFECTIVE USE OF THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE |
12 | TABLE OF CONTENTS |
14 | ECCCNYS—COMMERCIAL PROVISIONS TABLE OF CONTENTS |
16 | CHAPTER 1 [CE] SCOPE AND ADMINISTRATION [NY] SECTION C101 SCOPE AND GENERAL REQUIREMENTS |
17 | [NY] SECTION C102 APPLICABILITY |
18 | [NY] SECTION C103 INTERPRETATIONS OF ENERGY CODE REQUIREMENTS |
19 | [NY] SECTION C104 ALTERNATIVE MATERIALS, DESIGNS, METHODS OF CONSTRUCTION AND INSULATING SYSTEMS SECTION C105 CONSTRUCTION DOCUMENTS |
20 | [NY] SECTION C106 INSPECTIONS |
22 | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS |
30 | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONES [NY] TABLE C301.1 NEW YORK STATE CLIMATE ZONES BY COUNTY [NY] TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT |
31 | TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
32 | CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL SECTION C402 BUILDING ENVELOPE REQUIREMENTS |
33 | EQUATION 4-1 EQUATION 4-2 |
34 | [NY] TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD |
35 | [NY] TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD |
36 | TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES |
37 | EQUATION 4-3 |
38 | TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa [NY] TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS EQUATION 4-4 |
39 | EQUATION 4-5 |
41 | TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES |
42 | SECTION C403 BUILDING MECHANICAL SYSTEMS |
43 | EQUATION 4-6 EQUATION 4-7 TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY TABLE C403.3.4 BOILER TURNDOWN |
44 | TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
45 | TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
46 | TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
47 | TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
48 | TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
49 | TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
50 | TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED |
51 | TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS |
52 | TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT |
53 | TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT |
55 | [NY] TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS |
56 | [NY] TABLE C403.5(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS [NY] TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS |
57 | TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb |
60 | [NY] TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year) [NY] TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year) |
61 | TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH |
62 | TABLE C403.8.1(1) FAN POWER LIMITATION |
63 | TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT |
64 | TABLE C403.8.5.1 COOLING SYSTEMS |
66 | TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS |
67 | TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS |
68 | TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS |
69 | EQUATION 4-8 |
70 | TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a, SECTION C404 SERVICE WATER HEATING (MANDATORY) |
72 | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
73 | TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
74 | TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS |
76 | EQUATION 4-9 |
78 | FIGURE C405.2.3.2 SIDELIT ZONE FIGURE C405.2.3.3(1) TOPLIT ZONE |
79 | EQUATION 4-10 FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR |
80 | EQUATION 4-11 |
81 | TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
82 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
83 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES |
84 | SECTION C406 ADDITIONAL EFFICIENCY PACKAGES |
85 | TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
86 | TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS |
87 | TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b |
88 | TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa |
89 | TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa SECTION C407 TOTAL BUILDING PERFORMANCE |
91 | SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING |
92 | TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
93 | TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
94 | TABLE C407.5.1(2) HVAC SYSTEMS MAP |
95 | TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS |
96 | TABLE C407.5.1(4) NUMBER OF CHILLERS TABLE C407.5.1(5) WATER CHILLER TYPES |
99 | FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST |
100 | CHAPTER 5 [CE] EXISTING BUILDINGS SECTION C501 GENERAL SECTION C502 ADDITIONS |
101 | SECTION C503 ALTERATIONS |
102 | SECTION C504 REPAIRS SECTION C505 CHANGE OF OCCUPANCY OR USE |
104 | CHAPTER 6 [CE] REFERENCED STANDARDS AAMA AHAM AHRI |
105 | AMCA ANSI APSP ASHRAE |
106 | ASME ASTM |
107 | CRRC CSA CTI DASMA DOE |
108 | ICC IEEE IES |
109 | ISO NEMA NFPA NFRC SMACNA UL |
110 | US-FTC WDMA |
112 | APPENDIX CA SOLAR-READY ZONE—COMMERCIAL SECTION CA101 SCOPE SECTION CA102 GENERAL DEFINITION SECTION CA103 SOLAR-READY ZONE |
114 | INDEX |
124 | ECCCNYS—RESIDENTIAL PROVISIONS TABLE OF CONTENTS |
126 | CHAPTER 1 [RE] SCOPE AND ADMINISTRATION [NY] SECTION R101 SCOPE AND GENERAL REQUIREMENTS |
127 | [NY] SECTION R102 APPLICABILITY |
128 | [NY] SECTION R103 INTERPRETATIONS OF ENERGY CODE REQUIREMENTS [NY] SECTION R104 ALTERNATIVE MATERIALS, DESIGNS, METHODS OF CONSTRUCTION AND INSULATING SYSTEMS |
129 | [NY] SECTION R105 CONSTRUCTION DOCUMENTS [NY] SECTION R106 INSPECTIONS |
132 | CHAPTER 2 [RE] DEFINITIONS SECTION R201 GENERAL SECTION R202 GENERAL DEFINITIONS |
136 | CHAPTER 3 [RE] GENERAL REQUIREMENTS SECTION R301 CLIMATE ZONES [NY] TABLE R301.1 NEW YORK STATE CLIMATE ZONES BY COUNTY [NY] TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION R302 DESIGN CONDITIONS SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT |
137 | TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
138 | CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE |
139 | [NY] TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa [NY] TABLE R402.1.4 EQUIVALENT U-FACTORSa |
140 | TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES |
143 | TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa |
144 | SECTION R403 SYSTEMS |
146 | TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYa |
147 | SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) |
148 | [NY] TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
149 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
150 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
152 | SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE EQUATION 4-1 [NY] TABLE R406.4 MAXIMUM ENERGY RATING INDEX |
154 | CHAPTER 5 [RE] EXISTING BUILDINGS SECTION R501 GENERAL SECTION R502 ADDITIONS |
155 | SECTION R503 ALTERATIONS SECTION R504 REPAIRS |
156 | SECTION R505 CHANGE OF OCCUPANCY OR USE |
158 | CHAPTER 6 [RE] REFERENCED STANDARDS AAMA ACCA APSP ASHRAE |
159 | ASTM BOMA CSA DASMA HVI |
160 | ICC IEEE NFPA |
161 | NFRC RESNET UL US-FTC WDMA |
162 | APPENDIX RA SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES SECTION RA101 SCOPE SECTION RA102 GENERAL DEFINITION SECTION RA103 SOLAR-READY ZONE |
164 | INDEX |
170 | HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR ENERGY CODE |
171 | ICC EVALUATION SERVICE |
172 | ICC DIGITAL CODES LIBRARY |
173 | ICC ASSESSMENT CENTER |