Shopping Cart

No products in the cart.

NY StateFuelGasCode 2020

$53.35

Fuel Gas Code of New York State

Published By Publication Date Number of Pages
NY 2020 187
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2018 International Fuel Gas Code.

PDF Catalog

PDF Pages PDF Title
1 2020 FUEL GAS CODE OF NEW YORK STATE
2 2020 FUEL GAS CODE OF NEW YORK STATE TITLE PAGE
3 COPYRIGHT
4 ACKNOWLEDGMENTS
6 PREFACE
8 EFFECTIVE USE OF THE FUEL GAS CODE OF NEW YORK STATE
10 TABLE OF CONTENTS
12 [NY] CHAPTER 1 SCOPE AND ADMINISTRATION
[NY] SECTION 101 TITLE, SCOPE AND PURPOSE
SECTION 608 VENTED WALL FURNACES
13 [NY] SECTION 102 APPLICABILITY
14 [NY] SECTION 103 ADMINISTRATION AND ENFORCEMENT
15 [NY] SECTION 104 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION
16 [NY] SECTION 105 BUILDING PERMITS, CONSTRUCTION INSPECTIONS, STOP WORK ORDERS, AND CERTIFICATES OF OCCUPANCY
17 [NY] SECTION 106 SUBMITTAL DOCUMENTS
18 [NY] SECTION 107 SERVICE UTILITIES
20 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
28 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
29 SECTION 302 STRUCTURAL SAFETY
SECTION 303 APPLIANCE LOCATION
30 SECTION 304 COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 3-1
EQUATION 3-2
31 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
32 FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2)
33 SECTION 305 INSTALLATION
34 SECTION 306 ACCESS AND SERVICE SPACE
36 SECTION 307 CONDENSATE DISPOSAL
SECTION 308 CLEARANCE REDUCTION
37 TABLE 308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
SECTION 309 ELECTRICAL
SECTION 310 ELECTRICAL BONDING
38 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
40 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 GENERAL
SECTION 402 PIPE SIZING
EQUATION 4-1
41 EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
SECTION 403 PIPING MATERIALS
42 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
43 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
44 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
45 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
46 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
47 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
48 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
49 TABLE 402.4(8) SEMI RIGID COPPER TUBING
50 TABLE 402.4(9) SEMIRIGID COPPER TUBING
51 TABLE 402.4(10) SEMIRIGID COPPER TUBING
52 TABLE 402.4(11) SEMIRIGID COPPER TUBING
53 TABLE 402.4(12) SEMIRIGID COPPER TUBING
54 TABLE 402.4(13) SEMIRIGID COPPER TUBING
55 TABLE 402.4(14) SEMIRIGID COPPER TUBING
56 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
57 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
58 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
59 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
60 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
61 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
62 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
63 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
64 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
65 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
66 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
67 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
68 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
69 TABLE 402.4(29) SEMIRIGID COPPER TUBING
70 TABLE 402.4(30) SEMIRIGID COPPER TUBING
71 TABLE 402.4(31) SEMIRIGID COPPER TUBING
72 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
73 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
74 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
75 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
76 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
77 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
79 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
80 SECTION 404 PIPING SYSTEM INSTALLATION
82 SECTION 405 PIPING BENDS AND CHANGES IN DIRECTION
83 SECTION 406 INSPECTION, TESTING AND PURGING
84 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
85 SECTION 407 PIPING SUPPORT
SECTION 408 DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
86 SECTION 409 SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
SECTION 410 FLOW CONTROLS
87 SECTION 411 APPLIANCE AND MANUFACTURED HOME CONNECTIONS
88 SECTION 412 LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
90 SECTION 413 COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
91 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
92 SECTION 416 OVERPRESSURE PROTECTION DEVICES
94 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 GENERAL
95 SECTION 502 VENTS
96 SECTION 503 VENTING OF APPLIANCES
97 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
99 FIGURE 503.6.5 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE NOT LESS THAN 8 FEET FROM A VERTICAL WALL
102 TABLE 503.8 THROUGH-THE-WALL, DIRECT-VENT TERMINATION CLEARANCES
TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
103 TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
104 TABLE 503.10.5 CLEARANCES FOR CONNECTORSa
105 SECTION 504 SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
107 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
109 SECTION 505 DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
110 SECTION 506 FACTORY-BUILT CHIMNEYS
111 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
112 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
113 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
114 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
115 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
116 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
117 TABLE 504.2(3) MASONRY CHIMNEY
118 TABLE 504.2(3)—continued MASONRY CHIMNEY
119 TABLE 504.2(4) MASONRY CHIMNEY
120 TABLE 504.2(4)—continued MASONRY CHIMNEY
121 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
122 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
123 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
124 TABLE 504.3(1)—continued TYPE B DOUBLE-WALL VENT
125 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
126 TABLE 504.3(3) MASONRY CHIMNEY
127 TABLE 504.3(4) MASONRY CHIMNEY
128 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
129 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY—continued
130 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
132 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 GENERAL
SECTION 602 DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 LOG LIGHTERS
SECTION 604 VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 VENTED GAS FIREPLACE HEATERS
SECTION 606 INCINERATORS AND CREMATORIES
SECTION 607 COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 609 FLOOR FURNACES
133 SECTION 610 DUCT FURNACES
SECTION 611 NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
134 SECTION 612 RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 CLOTHES DRYERS
SECTION 614 CLOTHES DRYER EXHAUST
135 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
136 SECTION 615 SAUNA HEATERS
SECTION 616 ENGINE AND GAS TURBINE-POWERED EQUIPMENT
137 SECTION 617 POOL AND SPA HEATERS
SECTION 618 FORCED-AIR WARM-AIR FURNACES
SECTION 619 CONVERSION BURNERS
138 SECTION 620 UNIT HEATERS
SECTION 621 UNVENTED ROOM HEATERS
SECTION 622 VENTED ROOM HEATERS
SECTION 623 COOKING APPLIANCES
139 SECTION 624 WATER HEATERS
SECTION 625 REFRIGERATORS
SECTION 626 GAS-FIRED TOILETS
SECTION 627 AIR-CONDITIONING APPLIANCES
140 SECTION 628 ILLUMINATING APPLIANCES
SECTION 629 SMALL CERAMIC KILNS
SECTION 630 INFRARED RADIANT HEATERS
141 SECTION 631 BOILERS
SECTION 632 EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 GASEOUS HYDROGEN SYSTEMS
SECTION 636 OUTDOOR DECORATIVE APPLIANCES
142 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 GENERAL
SECTION 702 GENERAL DEFINITIONS
SECTION 703 GENERAL REQUIREMENTS
143 SECTION 704 PIPING, USE AND HANDLING
144 SECTION 705 TESTING OF HYDROGEN PIPING SYSTEMS
145 SECTION 706 LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION 707 OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
146 CHAPTER 8 REFERENCED STANDARDS
ANSI
147 ASME
148 ASTM
149 CGA
CSA
DOTn
ICC
150 MSS
NFPA
UL
152 APPENDIX A SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
153 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
154 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
155 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
157 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
158 TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
159 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
160 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
161 FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
162 APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
163 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE BDOUBLE-WALL VENT CONNECTOR
164 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
165 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
166 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
167 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
169 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
170 FIGURE B-19
172 APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
174 APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
175 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
176 D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
177 D.6 APPLIANCE-SPECIFIC INSPECTIONS
178 TABLE D.6 CO THRESHOLDS
179 TABLE D.6—continued CO THRESHOLDS
180 INDEX
184 VALUABLE GUIDES TO CHANGES IN THE 2018 I-CODES®
185 ICC MEMBERSHIP
186 ICC ASSESSMENT CENTER
187 ICC EVALUATION SERVICE
NY StateFuelGasCode 2020
$53.35