PDF Pages PDF Title
1 2020 PLUMBING CODE OF NEW YORK STATE
2 2020 PLUMBING CODE OF NEW YORK STATE TITLE PAGE
3 COPYRIGHT
4 ACKNOWLEDGMENTS
6 PREFACE
8 EFFECTIVE USE OF THE PLUMBING CODE OF NEW YORK STATE
12 TABLE OF CONTENTS
16 [NY] CHAPTER 1 SCOPE AND ADMINISTRATION
[NY] SECTION 101 TITLE, SCOPE AND PURPOSE
[NY] SECTION 102 APPLICABILITY
18 [NY] SECTION 103 ADMINISTRATION AND ENFORCEMENT
19 [NY] SECTION 104 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION
[NY] SECTION 105 BUILDING PERMITS, CONSTRUCTION INSPECTIONS, STOP WORK ORDERS, AND CERTIFICATES OF OCCUPANCY
21 [NY] SECTION 106 SUBMITTAL DOCUMENTS
22 [NY] SECTION 107 SERVICE UTILITIES
24 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
32 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION 303 MATERIALS
SECTION 304 RODENTPROOFING
33 SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
34 SECTION 307 STRUCTURAL SAFETY
SECTION 308 PIPING SUPPORT
SECTION 309 FLOOD HAZARD RESISTANCE
35 TABLE 308.5 HANGER SPACING
SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
37 SECTION 313 EQUIPMENT EFFICIENCIES
SECTION 314 CONDENSATE DISPOSAL
[M] TABLE 314.2.2 CONDENSATE DRAIN SIZING
38 SECTION 315 PENETRATIONS
SECTION 316 ALTERNATIVE ENGINEERED DESIGN
40 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILITIES
[NY] TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
41 [NY] TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
42 [NY] TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
44 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
SECTION 405 INSTALLATION OF FIXTURES
45 SECTION 406 AUTOMATIC CLOTHES WASHERS
46 SECTION 407 BATHTUBS
SECTION 408 BIDETS
SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
47 SECTION 412 FAUCETS AND FIXTURE FITTINGS
SECTION 413 FLOOR AND TRENCH DRAINS
SECTION 414 FLOOR SINKS
SECTION 415 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
48 SECTION 416 FOOD WASTE DISPOSER UNITS
SECTION 417 GARBAGE CAN WASHERS
SECTION 418 LAUNDRY TRAYS
SECTION 419 LAVATORIES
49 SECTION 420 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 421 SHOWERS
50 SECTION 422 SINKS
SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 URINALS
SECTION 425 WATER CLOSETS
SECTION 426 WHIRLPOOL BATHTUBS
52 CHAPTER 5 WATER HEATERS
SECTION 501 GENERAL
SECTION 502 INSTALLATION
SECTION 503 CONNECTIONS
53 SECTION 504 SAFETY DEVICES
54 SECTION 505 INSULATION
56 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
SECTION 603 WATER SERVICE
57 SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
[NY] TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
58 TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
TABLE 604.10.1 MANIFOLD SIZING
SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
59 TABLE 605.3 WATER SERVICE PIPE
60 TABLE 605.4 WATER DISTRIBUTION PIPE
TABLE 605.8 MANUFACTURED PIPE NIPPLES
61 TABLE 605.5 PIPE FITTINGS
TABLE 605.7 VALVES
64 SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
65 TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
66 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
67 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
68 FIGURE 608.9.1 PICTOGRAPH—DO NOT DRINK
TABLE 608.9.2.2 SIZE OF PIPE IDENTIFICATION
70 TABLE 608.16.1 MINIMUM REQUIRED AIR GAPS
71 SECTION 609 HEALTH CARE PLUMBING
SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
72 SECTION 611 DRINKING WATER TREATMENT UNITS
SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
74 CHAPTER 7 SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
75 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
SECTION 703 BUILDING SEWER
76 TABLE 702.4 PIPE FITTINGS
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
SECTION 705 JOINTS
79 TABLE 705.18 CAULKING FERRULE SPECIFICATIONS
TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
80 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION 708 CLEANOUTS
81 SECTION 709 FIXTURE UNITS
TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION 710 DRAINAGE SYSTEM SIZING
TABLE 710.1(1) BUILDING DRAINS AND SEWERS
82 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
83 TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
SECTION 712 SUMPS AND EJECTORS
84 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
SECTION 713 COMPUTERIZED DRAINAGE DESIGN
SECTION 714 BACKWATER VALVES
85 SECTION 715 VACUUM DRAINAGE SYSTEMS
SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS
86 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
87 SECTION 803 SPECIAL WASTES
88 CHAPTER 9 VENTS
SECTION 901 GENERAL
SECTION 902 MATERIALS
SECTION 903 VENT TERMINALS
SECTION 904 OUTDOOR VENT EXTENSIONS
89 SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 VENT PIPE SIZING
SECTION 907 VENTS FOR STACK OFFSETS
90 TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
91 TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS
SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
SECTION 909 FIXTURE VENTS
TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION 910 INDIVIDUAL VENT
SECTION 911 COMMON VENT
92 TABLE 911.3 COMMON VENT SIZES
SECTION 912 WET VENTING
TABLE 912.3 WET VENT SIZE
SECTION 913 WASTE STACK VENT
TABLE 913.4 WASTE STACK VENT SIZE
93 SECTION 914 CIRCUIT VENTING
SECTION 915 COMBINATION WASTE AND VENT SYSTEM
TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE
SECTION 916 ISLAND FIXTURE VENTING
94 SECTION 917 SINGLE-STACK VENT SYSTEM
TABLE 917.2 SINGLE STACK SIZE
95 SECTION 918 AIR ADMITTANCE VALVES
SECTION 919 ENGINEERED VENT SYSTEMS
EQUATION 9-1
96 TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
SECTION 920 COMPUTERIZED VENT DESIGN
98 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
99 SECTION 1003 INTERCEPTORS AND SEPARATORS
100 TABLE 1003.3.5.1 CAPACITY OF GREASE INTERCEPTORSa
101 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
102 CHAPTER 11 STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
103 TABLE 1102.5 SUBSOIL DRAIN PIPE
TABLE 1102.7 PIPE FITTINGS
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
104 [NY] FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
105 TABLE 1106.2 STORM DRAIN PIPE SIZING
TABLE 1106.3 VERTICAL LEADER SIZING
SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS
SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS
106 TABLE 1106.6 HORIZONTAL GUTTER SIZING
SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER
SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
107 SECTION 1113 SUMPS AND PUMPING SYSTEMS
108 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION 1201 GENERAL
SECTION 1202 MEDICAL GASES
SECTION 1203 OXYGEN SYSTEMS
110 CHAPTER 13 NONPOTABLE WATER SYSTEMS
SECTION 1301 GENERAL
FIGURE 1301.3 PICTOGRAPH—DO NOT DRINK
112 SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS
113 TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS
114 SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS
115 TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS
116 SECTION 1304 RECLAIMED WATER SYSTEMS
118 CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 SYSTEM DESIGN AND SIZING
EQUATION 14-1
119 TABLE 1402.3 LOCATION OF SUBSURFACE IRRIGATION SYSTEM
SECTION 1403 INSTALLATION
TABLE 1403.1.1 DESIGN LOADING RATE
120 TABLE 1403.2 DISTRIBUTION PIPE
122 CHAPTER 15 REFERENCED STANDARDS
ANSI
ASHRAE
ASME
124 ASPE
ASSE
127 ASTM
131 AWS
132 AWWA
CISPI
CSA
135 IAPMO
ICC
ISEA
136 MSS
NFPA
NGWA
NSF
137 PDI
PSAI
UL
138 [NY] APPENDIX A RESERVED
140 APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES
142 [NY] APPENDIX C STRUCTURAL SAFETY
SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
144 [NY] APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES
[NY] TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN NEW YORK STATE
146 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
150 TABLE E.1
TABLE E.2
151 FIGURE E103.3(1) EXAMPLE-SIZING
152 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
153 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
154 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
155 TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
156 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
157 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING)
158 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING)
159 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING)
160 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
161 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
162 FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa
163 SECTION E201 SELECTION OF PIPE SIZE
SECTION E202 DETERMINATION OF PIPE VOLUMES
164 TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
165 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
166 TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
168 INDEX
180 HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR PLUMBING CODE
181 ICC MEMBERSHIP
182 ICC ASSESSMENT CENTER
183 ICC EVALUATION SERVICE
NY StatePlumbingCode 2020