Shopping Cart

No products in the cart.

OH MechanicalCode 2024 1stptg

$66.63

Ohio Mechanical Code

Published By Publication Date Number of Pages
OH 2024 171
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2021 International Mechanical Code®.

PDF Catalog

PDF Pages PDF Title
1 2024 OHIO MECHANICAL CODE©
2 2024 OHIO MECHANICAL CODE©
3 COPYRIGHT
4 PREFACE
8 TABLE OF CONTENTS
12 CHAPTER 1 SCOPE AND ADMINISTRATION
SECTION 101 GENERAL
14 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
28 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
29 SECTION 302 PROTECTION OF STRUCTURE
30 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
32 SECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
34 SECTION 307 CONDENSATE DISPOSAL
TABLE 307.2.2 CONDENSATE DRAIN SIZING
35 SECTION 308 CLEARANCE REDUCTION
36 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
37 SECTION 309 TEMPERATURE CONTROL
SECTION 310 EXPLOSION CONTROL
SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
SECTION 313 WELDING AND BRAZING
38 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
SECTION 402 NATURAL VENTILATION
39 SECTION 403 MECHANICAL VENTILATION
40 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESSa, b, c, d
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
41 EQUATION 4-5
TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCYa, b
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
42 EQUATION 4-9
TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3 AND R-4 OCCUPANCIES
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
43 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
44 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
45 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
46 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
47 SECTION 502 REQUIRED SYSTEMS
EQUATION 5-1
54 SECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST
55 TABLE 504.9.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
56 SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT
57 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
62 SECTION 507 COMMERCIAL KITCHEN HOODS
64 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
65 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
66 SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
68 TABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
69 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
71 EQUATION 5-2
72 EQUATION 5-3
73 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
76 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
77 SECTION 602 PLENUMS
79 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
80 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
81 SECTION 604 INSULATION
82 SECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
83 SECTION 607 DUCT AND TRANSFER OPENINGS
84 TABLE 607.3.2.1 FIRE DAMPER RATING
89 SECTION 608 BALANCING
90 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
92 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
93 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
94 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
95 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCESa, b, c, d
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
96 TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
97 SECTION 805 FACTORY-BUILT CHIMNEYS
SECTION 806 METAL CHIMNEYS
98 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
99 SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
100 SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
SECTION 914 SAUNA HEATERS
101 SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES
SECTION 919 CONVERSION BURNERS
102 SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 RADIANT HEATING SYSTEMS
103 SECTION 928 EVAPORATIVE COOLING EQUIPMENT
SECTION 929 UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCES
SECTION 930 LARGE-DIAMETER CEILING FANS
104 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 PRESSURE VESSELS
105 SECTION 1004 BOILERS
TABLE 1004.3.1 BOILER TOP CLEARANCES
106 SECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF
SECTION 1008 BOTTOM BLOWOFF VALVE
107 SECTION 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
SECTION 1010 GAUGES
SECTION 1011 TESTS
108 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
TABLE 1101.2 FACTORY-BUILT EQUIPMENT AND APPLIANCES
SECTION 1102 SYSTEM REQUIREMENTS
109 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
110 SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
111 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
112 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
113 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
114 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
115 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
116 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
117 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
118 EQUATION 11-1
EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
119 TABLE 1106.4.2 MINIMUM EXHAUST RATES
SECTION 1107 PIPING MATERIAL
TABLE 1107.4 REFRIGERANT PIPE
120 TABLE 1107.5 REFRIGERANT PIPE FITTINGS
TABLE 1107.5.1 COPPER BRAZED SWAGED CUP DEPTHS
SECTION 1108 JOINTS AND CONNECTIONS
121 SECTION 1109 REFRIGERANT PIPE INSTALLATION
122 TABLE 1109.3.2 SHAFT VENTILATION VELOCITY
123 SECTION 1110 REFRIGERATION PIPING SYSTEM TEST
124 SECTION 1111 PERIODIC TESTING
126 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
127 SECTION 1203 JOINTS AND CONNECTIONS
TABLE 1202.5 HYDRONIC PIPE FITTINGS
129 SECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
130 SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
131 TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
134 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING AND FITTINGS
SECTION 1303 JOINTS AND CONNECTIONS
135 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
136 SECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 FUEL OIL AND DIESEL OIL STORAGE
137 SECTION 1309 TESTING
138 CHAPTER 14 SOLAR THERMAL SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 DESIGN AND INSTALLATION
140 SECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 LABELING
142 CHAPTER 15 REFERENCED STANDARDS
ACCA
AHRI
AMCA
ANSI
143 ASHRAE
ASME
144 ASSE
ASSP
ASTM
148 AWS
149 AWWA
CPSC
CSA
150 DOL
FDA
FS
ICC
151 IIAR
MSS
NAIMA
NBBI
NFPA
152 NSF
153 SMACNA
UL
158 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS DELETED
160 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULEDELETED
162 APPENDIX C BOARD OF APPEALS DELETED
164 INDEX
170 ICC EVALUATION SERVICE®
171 ICC DIGITAL CODES PREMIUM
OH MechanicalCode 2024 1stptg
$66.63