Shopping Cart

No products in the cart.

Residential Code of Ohio 2013

$61.10

Residential Code of Ohio

Published By Publication Date Number of Pages
OH 2013 644
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 2013 RESIDENTIAL CODE OF OHIO
2 COPYRIGHT
3 PREFACE
5 EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE
9 TABLE OF CONTENTS
13 PART I – ADMINISTRATION
CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
14 SECTION 102 APPLICABILITY AND JURISDICTIONAL AUTHORITY
17 SECTION 103 CERTIFIED RESIDENTIAL BUILDING DEPARTMENTS, PERSONNEL, AND APPEALS BOARDS
SECTION 104 DUTIES AND RESPONSIBILITIES
18 SECTION 105 APPROVALS
20 SECTION 106 CONSTRUCTION DOCUMENTS
22 SECTION 107 PLAN APPROVAL PROCESS
24 SECTION 108 INSPECTION PROCESS
26 SECTION 109 ORDERS, VIOLATIONS, AND UNSAFE BUILDINGS
27 SECTION 110 APPEALS
SECTION 111 CERTIFICATE OF OCCUPANCY
28 SECTION 112 CHANGES TO THE CODE
SECTION 113 EXISTING BUILDINGS AND STRUCTURES
29 SECTION 114 PRODUCTS AND MATERIALS
31 FIGURE 114.2 ORGANIZATION OF BOARD RECOGNIZED BODIES AND CERTIFICATION PROGRAMS
32 SECTION 115 BOARD ORGANIZATION
33 PART II – DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
49 PART III – BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION 301 DESIGN CRITERIA
50 TABLE 301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
51 TABLE 301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf)a, b, c, d, e
52 TABLE 301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
FIGURE 301.2(1) ISOLINES OF THE 971/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES ( F)
53 FIGURE 301.2(2) SEISMIC DESIGN CATEGORIES—SITE CLASS D
54 FIGURE 301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE
55 FIGURE 301.2(4) BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
56 FIGURE 301.2(5) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
57 FIGURE 301.2(6) TERMITE INFESTATION PROBABILITY MAP
58 FIGURE 301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
59 TABLE 301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa
60 TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
61 TABLE 301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa
63 TABLE 301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
TABLE 301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FOR CEPER SQUARE FOOT OF HORIZONTAL PROJECTION
64 TABLE 301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS
SECTION 302 FIRE-RESISTANT CONSTRUCTION
TABLE R302.1 EXTERIOR WALLS
67 TABLE R302.6 DWELLING/GARAGE SEPARATIONa
69 SECTION 303 LIGHT, VENTILATION AND HEATING
70 SECTION 304 MINIMUM ROOM AREAS
SECTION 305 CEILING HEIGHT
SECTION 306 SANITATION
SECTION 307 TOILET, BATH AND SHOWER SPACES
71 FIGURE 307.1 MINIMUM FIXTURE CLEARANCES
SECTION 308 GLAZING
72 TABLE 308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE 308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
74 SECTION 309 GARAGES AND CARPORTS
SECTION 310 EMERGENCY ESCAPE AND RESCUE OPENINGS
75 SECTION 311 MEANS OF EGRESS
77 SECTION 312 GUARDS
78 SECTION 313 AUTOMATIC FIRE SPRINKLER SYSTEMS
SECTION 314 SMOKE ALARMS
79 SECTION 315 CARBON MONOXIDE ALARMS
SECTION 316 FOAM PLASTIC
81 SECTION 317 PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY
82 SECTION 318 PROTECTION AGAINST SUBTERRANEAN TERMITES
83 SECTION 319 SITE ADDRESS
SECTION 320 ACCESSIBILITY
84 SECTION 321 ELEVATORS AND PLATFORM LIFTS
SECTION 322 FLOOD-RESISTANT CONSTRUCTION
87 SECTION 323 STORM SHELTERS
SECTION 324 POST FRAME ACCESSORY STRUCTURES
TABLE 324.3 POST FRAME PIER FOOTING DIAMETERS
88 FIGURE 324 POST AND FRAME WALL SECTION (NO SCALE)
FIGURE 324.1 COLUMN UPLIFT PROTECTION EXCEPTION (NO SCALE
89 TABLE 324.4.5 GABLE END HEADER SIZES
TABLE 324.4.7 BEAM OR TRUSS CONNECTION AT COLUMNS MINIMUM FASTENERS OR TOTAL SHEAR OR WITHDRAW VALUESa, b, c
TABLE 324.6 KNEE BRACE VERTICAL DISTANCE
90 TABLE 324.7 STRUCTURAL FASTENES
91 CHAPTER 4 FOUNDATIONS
SECTION 401 GENERAL
TABLE 401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
SECTION 402 MATERIALS
92 TABLE 402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION 403 FOOTINGS
93 TABLE 403.1 MINIMUM WIDTH OF CONCRETE, PRECAST OR MASONRY FOOTINGS (inches)a
94 FIGURE 403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS
95 FIGURE 403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
96 FIGURE 403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
97 FIGURE 403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
99 FIGURE 403.3(1) INSULATION PLACEMENT FOR FROST PROTECTED FOOTINGS IN HEATED BUILDINGS
TABLE 403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
100 FIGURE 403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
101 TABLE 403.3(2) AIR-FREEZING INDEX FOR OHIO LOCATIONS BY COUNTY
FIGURE 403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
102 FIGURE 403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
TABLE 403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (inches)
103 FIGURE 403.4(1) BASEMENT OR CRAWL SPACE WITH PRECASTFOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE 403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
TABLE 403.5 MINIMUM FOOTING SIZE FOR DECK FOOTINGS WITHOUT ROOF LOADS
SECTION 404 FOUNDATION AND RETAINING WALLS
104 TABLE 404.1.1(1) PLAIN MASONRY FOUNDATION WALLS
105 TABLE 404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHESa, c
106 TABLE 404.1.1(3) 10-INCH FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHESa,
107 TABLE 404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHESa, c
108 TABLE 404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLSa, b
109 TABLE 404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, g, h, i, j
110 TABLE 404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i
111 TABLE 404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i
112 TABLE 404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, g, h, i
113 TABLE 404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, f, h, i, j
114 TABLE 404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLSb, c, d, e, g, h, i,
115 TABLE 404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLSb, c, d, e, f, h, i, k, n
116 TABLE 404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEELa, b, c
117 TABLE 404.1.2(9)—continued MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEELa, b, c
120 FIGURE 404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
121 SECTION 405 FOUNDATION DRAINAGE
122 TABLE 404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION
123 TABLE 405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
SECTION 406 FOUNDATION WATERPROOFING AND DAMPPROOFING
124 SECTION 407 COLUMNS
125 SECTION 408 UNDER-FLOOR SPACE
SECTION 409 FOUNDATION INSULATION
127 CHAPTER 5 FLOORS
SECTION 501 GENERAL
SECTION 502 WOOD FLOOR FRAMING
128 FIGURE 502.2 FLOOR CONSTRUCTION
129 TABLE 502.2.2.1 FASTENER SPACING FOR A SOUTHERN PINE OR HEM-FIR DECK LEDGER AND A 2-INCH NOMINAL SOLID-SAWN SPRUCE-PINE-FIR BAND JOISTc, f, g
FIGURE 502.2.2.3 DECK ATTACHMENT FOR LATERAL LOADS
131 TABLE 502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
132 TABLE 502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
133 TABLE 502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf)
TABLE 502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f
134 TABLE 502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
135 TABLE 502.5(1)— continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
136 TABLE 502.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
137 FIGURE 502.8 CUTTING, NOTCHING AND DRILLING
138 SECTION 503 FLOOR SHEATHING
TABLE 503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
139 TABLE 503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa
140 TABLE 503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION 504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND)
SECTION 505 STEEL FLOOR FRAMING
141 FIGURE 505.1.2 IN-LINE FRAMING
142 FIGURE 505.2(1) C-SHAPED SECTION
FIGURE 505.2(2) TRACK SECTION
TABLE 505.2 (1) COLD-FORMED STEEL JOIST SIZES
TABLE 505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
143 TABLE 505.2.4 SCREW SUBSTITUTION FACTOR
FIGURE 505.2.5.1 FLOOR JOIST WEB HOLES
144 FIGURE 505.2.5.3 WEB HOLE PATCH
145 TABLE 505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTSa
FIGURE 505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION
146 TABLE 505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE 505.3.1(2) FLOOR TO WOOD SILL CONNECTION
147 FIGURE 505.3.1(3) FLOOR TO FOUNDATION CONNECTION
FIGURE 505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION
148 FIGURE 505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION
FIGURE 505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
149 FIGURE 505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
150 FIGURE 505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE 505.3.1(9) BEARING STIFFENERS FOR END JOISTS
151 TABLE 505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE SPANS
FIGURE 505.3.3.2(1) JOIST BLOCKING (SOLID)
152 TABLE 505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b, c, d, e, f 33 ksi STEEL
FIGURE 505.3.3.2(2) JOIST BLOCKING (STRAP)
153 TABLE 505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b, c, d, e, f 50 ksi STEEL
154 FIGURE 505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
TABLE 505.3.4(1) CLIP ANGLE BEARING STIFFENERS (20 psf equivalent snow load)
155 TABLE 505.3.4(2) CLIP ANGLE BEARING STIFFENERS (30 psf equivalent snow load)
FIGURE 505.3.4(2) BEARING STIFFENER
156 TABLE 505.3.4 (3) CLIP ANGLE BEARING STIFFENERS (50 psf equivalent snow load)
TABLE 505.3.4 (4) CLIP ANGLE BEARING STIFFENERS (70 psf equivalent snow load)
157 FIGURE 505.3.7 TRACK SPLICE
158 FIGURE 505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION: 6-FOOT FLOOR OPENING
FIGURE 505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION: 8-FOOT FLOOR OPENING
159 FIGURE 505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
FIGURE 505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
160 SECTION 506 CONCRETE FLOORS (ON GROUND)
161 CHAPTER 6 WALL CONSTRUCTION
SECTION 601 GENERAL
TABLE 601.3.1 CLASS III VAPOR RETARDERS
162 SECTION 602 WOOD WALL FRAMING
163 TABLE 602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
164 TABLE 602.3(1)—continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
165 TABLE 602.3(2) ALTERNATE ATTACHMENTS
166 TABLE 602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE 602.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING
TABLE 602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
167 FIGURE 602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
168 FIGURE 602.3(2) FRAMING DETAILS
169 TABLE 602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESSIN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2b, c
170 TABLE 602.3.1—continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESSIN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2
171 FIGURE 602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
172 FIGURE 602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
173 FIGURE 602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
174 TABLE 602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERS
FIGURE 602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
175 FIGURE 602.10.1.1 BRACED WALL LINES
TABLE 602.10.1.3 BRACED WALL LINE SPACING
176 FIGURE 602.10.1.4 ANGLED WALLS
177 FIGURE 602.10.2.2 LOCATION OF BRACED WALL PANELS
178 TABLE 602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
179 TABLE 602.10.3(1)— continued BRACING REQUIREMENTS BASED ON WIND SPEED
180 TABLE 602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
181 TABLE 602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
182 TABLE 602.10.3(3)— continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
183 TABLE 602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
184 TABLE 602.10.4 BRACING METHODS
185 TABLE 602.10.4—continued BRACING METHODS
186 FIGURE 602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
187 TABLE 602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
188 TABLE 602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
TABLE 602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
FIGURE 602.10.6.1 METHOD ABW: ALTERNATE BRACED WALL PANEL
189 FIGURE 602.10.6.2 METHOD PFH: PORTAL FRAME WITH HOLD-DOWNS
190 FIGURE 602.10.6.3 METHOD PFG: PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B, AND C
TABLE 602.10.6.4 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHOD PFH, PFG AND CS-PF BRACED WALL PANELS
191 FIGURE 602.10.6.4 METHOD CS-PF: CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
192 TABLE 602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS
193 FIGURE 602.10.6.5 METHOD BV-WSP: WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC CATEGORIES D0, D1, AND D2
194 FIGURE 602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
195 FIGURE 602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
FIGURE 602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
196 FIGURE 602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE 602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
197 FIGURE 602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
198 FIGURE 602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
199 FIGURE 602.11.2 STEPPED FOUNDATION CONSTRUCTION
200 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
201 TABLE 602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
SECTION 603 STEEL WALL FRAMING
202 FIGURE 603.1.2 IN-LINE FRAMING
203 TABLE 603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES
TABLE 603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
FIGURE 603.2(1) C-SHAPED SECTION
FIGURE 603.2(2) TRACK SECTION
204 TABLE 603.2.4 SCREW SUBSTITUTION FACTOR
FIGURE 603.2.5.1 WEB HOLES
205 FIGURE 603.2.5.3 STUD WEB HOLE PATCH
206 TABLE 603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b
FIGURE 603.3.1(1) WALL TO FLOOR CONNECTION
207 FIGURE 603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE 603.3.1(3) WALL TO WOOD SILL CONNECTION
208 TABLE 603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTSa,b,c
TABLE 603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTSa,b,c
TABLE 603.3.2(1) WALL FASTENING SCHEDULEa
209 TABLE 603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 ksi STEEL
210 TABLE 603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
211 TABLE 603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
212 TABLE 603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
213 TABLE 603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
214 TABLE 603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
215 TABLE 603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
216 TABLE 603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
217 TABLE 603.3.2 (10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
218 TABLE 603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
219 TABLE 603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
220 TABLE 603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
221 TABLE 603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
222 TABLE 603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
223 TABLE 603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
224 TABLE 603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
225 TABLE 603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
226 TABLE 603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
227 TABLE 603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
228 TABLE 603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
229 TABLE 603.3.2(22) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
230 TABLE 603.3.2(23) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
231 TABLE 603.3.2(24) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
232 TABLE 603.3.2(25) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
233 TABLE 603.3.2(26) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
234 TABLE 603.3.2(27) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
235 TABLE 603.3.2(28) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
236 TABLE 603.3.2(29) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
237 TABLE 603.3.2(30) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
238 TABLE 603.3.2(31) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
240 SECTION 604 WOOD STRUCTURAL PANELS
241 FIGURE 603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE 603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
242 FIGURE 603.3.5 TRACK SPLICE
FIGURE 603.4 CORNER FRAMING
243 TABLE 603.3.2.1 (1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa,b,c 33 ksi STEEL
244 TABLE 603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa,b,c 50 ksi STEE
245 TABLE 603.3.2.1(3) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa,b,c 33 ksi STEEL
246 TABLE 603.3.2.1(4) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa,b,c 50 ksi STEEL
247 FIGURE 603.6(1) BOX BEAM HEADER
FIGURE 603.6(2) BACK-TO-BACK HEADER
248 FIGURE 603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE 603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
249 TABLE 603.6(1) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b
250 TABLE 603.6(2) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b
251 TABLE 603.6(3) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b
252 TABLE 603.6(4) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b
253 TABLE 603.6(5) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
254 TABLE 603.6(6) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
255 TABLE 603.6(7) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
256 TABLE 603.6(8) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
257 TABLE 603.6(9) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a
258 TABLE 603.6(10) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b
259 TABLE 603.6(11) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a, b
260 TABLE 603.6(12) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a,b
261 TABLE 603.6(13) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a,b
262 TABLE 603.6(14) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a,b
263 TABLE 603.6(15) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b
264 TABLE 603.6(16) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b
265 TABLE 603.6(17) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
266 TABLE 603.6(18) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
267 TABLE 603.6(19) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
268 TABLE 603.6(20) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
269 TABLE 603.6(21) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a, b
270 TABLE 603.6(22) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b
271 TABLE 603.6(23) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and ceiling (33 ksi steel)a, b
272 TABLE 603.6(24) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b
273 TABLE 603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE 603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d
274 TABLE 603.8 HEAD AND SILL TRACK SPAN Fy = 33 ksi
FIGURE 603.9 STRUCTURAL SHEATHING FASTENING PATTERN
275 FIGURE 603.9.2 CORNER STUD HOLD DOWN DETAIL
TABLE 603.9.2(1) MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b
276 TABLE 603.9.2(2) FULL HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
SECTION 605 PARTICLEBOARD
SECTION 606 GENERAL MASONRY CONSTRUCTION
277 TABLE 606.5 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
TABLE 606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
279 FIGURE 606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
280 FIGURE 606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
281 FIGURE 606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1, OR D
282 TABLE 606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
283 TABLE 606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE 606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE 606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
284 TABLE 606.15.1 MINIMUM CORROSION PROTECTION
SECTION 607 UNIT MASONRY
285 TABLE 607.1 MORTAR PROPORTIONSa, b
SECTION 608 MULTIPLE WYTHE MASONRY
286 SECTION 609 GROUTED MASONRY
TABLE 609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
287 TABLE 609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
288 SECTION 610 GLASS UNIT MASONRY
FIGURE 610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
289 SECTION 611 EXTERIOR CONCRETE WALL CONSTRUCTION
290 TABLE 611.3 DIMENSIONAL REQUIREMENTS FOR WALLSa,b
291 FIGURE 611.3(1) FLAT WALL SYSTEM
FIGURE 611.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE 611.3(3) SCREEN-GRID WALL SYSTEM
292 TABLE 611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
293 FIGURE 611.5.4(1) LAP SPLICES
294 FIGURE 611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
FIGURE 611.5.4(3) STANDARD HOOKS
295 TABLE 611.5.4(2) MAXIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEELa, b, c
296 FIGURE 611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE
FIGURE 611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY
297 FIGURE 611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE 611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON GROUND FOOTING
298 TABLE 611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLSa, b, c, d, e
299 TABLE 611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLSa, b, c, d, e
300 TABLE 611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLSa, b, c, d, e
301 TABLE 611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l
302 EQUATION 611-1
EQUATION 611-2
303 TABLE 611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORYa,c,d,e,f,g
304 TABLE 611.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORYa,c,d,e,f,g
305 TABLE 611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g
306 TABLE 611.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g
307 TABLE 611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa,c,d,e,f,g
308 TABLE 611.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f
309 FIGURE 611.7(1) MINIMUM SOLID WALL LENGTH
310 FIGURE 611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
311 TABLE 611.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
FIGURE 611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
312 TABLE 611.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEETa,
313 TABLE 611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLSa,c
315 FIGURE 611.8(1) REINFORCEMENT OF OPENINGS
316 FIGURE 611.8(2) LINTEL FOR FLAT WALLS
FIGURE 611.8(3) LINTELS FOR WAFFLE-GRID WALLS
317 FIGURE 611.8(4) LINTELS FOR SCREEN-GRID WALLS
319 TABLE 611.8(1) LINTEL DESIGN LOADING CONDITIONSa, b, d
320 TABLE 611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
321 TABLE 611.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
322 TABLE 611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
323 TABLE 611.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
324 TABLE 611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
325 TABLE 611.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
326 TABLE 611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
327 TABLE 611.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
328 TABLE 611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
329 TABLE 611.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
330 TABLE 611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
331 TABLE 611.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
332 TABLE 611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
333 TABLE 611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
334 TABLE 611.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE 611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSc, d, e, f, g
336 FIGURE 611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
337 TABLE 611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c
338 FIGURE 611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL
339 TABLE 611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b
340 FIGURE 611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR
341 TABLE 611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
342 FIGURE 611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL
343 TABLE 611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
344 FIGURE 611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
345 TABLE 611.9(5) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d
346 FIGURE 611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
347 TABLE 611.9(6) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b, c, d
348 FIGURE 611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR
349 TABLE 611.9(7) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
350 FIGURE 611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
351 TABLE 611.9(8) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
352 FIGURE 611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
353 TABLE 611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
354 FIGURE 611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PARALLEL
355 TABLE 611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
356 FIGURE 611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
357 TABLE 611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
358 FIGURE 611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
359 TABLE 611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
360 SECTION 612 EXTERIOR WINDOWS AND DOORS
FIGURE 612.8(1) THROUGH THE FRAME
361 FIGURE 612.8(2) FRAME CLIP
FIGURE 612.8(3) THROUGH THE FRAME
FIGURE 612.8(4) FRAME CLIP
FIGURE 612.8(5) THROUGH THE FLANGE
362 FIGURE 612.8(6) THROUGH THE FLANGE
FIGURE 612.8(7) FRAME CLIP
FIGURE 612.8(8) THROUGH THE FLANGE
363 SECTION 613 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
TABLE 613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE
TABLE 613.3.2 MINIMUM PROPERTIESa FOR WOOD STRUCTURAL PANEL FACING MATERIAL USED IN SIP WALLS
364 FIGURE 613.4 SIP WALL PANEL
365 TABLE 613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP LIGHT-FRAME ROOF ONLY (inches)
366 TABLE 613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (inches)
367 FIGURE 613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE 613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
368 FIGURE 613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE 613.5(4) SIP WALL TO WALL PLATFORM FRAME CONNECTION
369 FIGURE 613.5(5) SIP WALL TO WALL BALLOON FRAME CONNECTION
FIGURE 613.5.1 SIP WALL FRAMING CONFIGURATION
370 FIGURE 613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE 613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS
371 FIGURE 613.9 SIP CORNER FRAMING DETAIL
TABLE 613.10 MAXIMUM SPANS FOR 117/8 INCH DEEP SIP HEADERS (feet)
373 CHAPTER 7 WALL COVERING
SECTION 701 GENERAL
SECTION 702 INTERIOR COVERING
TABLE 702.1(1) THICKNESS OF PLASTER
TABLE 702.1(2) GYPSUM PLASTER PROPORTIONSa
374 TABLE 702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
TABLE 702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
376 TABLE 702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 703 EXTERIOR COVERING
378 TABLE 703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
379 TABLE 703.4—continued WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
TABLE 703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c (Dimensions are in inches)
381 TABLE 703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE 703.7(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE-, TWO- AND THREE-FAMILY DETACHED DWELLINGS, WOOD FRAMING, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
382 FIGURE 703.7 MASONRY VENEER WALL DETAILS
383 FIGURE 703.7—continued MASONRY VENEER WALL DETAILS
384 FIGURE 703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
385 FIGURE 703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
TABLE 703.7.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d
TABLE 703.7.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
386 FIGURE 703.7.3.2 MASONRY VENEER OPENING
389 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION 801 GENERAL
SECTION 802 WOOD ROOF FRAMING
391 TABLE 802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
392 TABLE 802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
393 TABLE 802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
394 TABLE 802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
395 TABLE 802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
396 TABLE 802.5.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
397 TABLE 802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
398 TABLE 802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
399 TABLE 802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
400 TABLE 802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
401 TABLE 802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)
402 TABLE 802.5.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)
403 TABLE 802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
404 TABLE 802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
405 TABLE 802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)
406 TABLE 802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)
407 TABLE 802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
408 TABLE 802.5.1(7)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
409 TABLE 802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
410 TABLE 802.5.1(8)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOADa (Ceiling attached to rafters, L/Δ = 240)
411 TABLE 802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa, b, c, d, e, f, h
412 FIGURE 802.5.1 BRACED RAFTER CONSTRUCTION
414 TABLE 802.11 REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCESa, b, c, e, f (Pounds per connection)
SECTION 803 ROOF SHEATHING
TABLE 803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
415 SECTION 804 STEEL ROOF FRAMING
TABLE 804.2.4 SCREW SUBSTITUTION FACTOR
416 FIGURE 804.1.2 IN-LINE FRAMING
TABLE 804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES
TABLE 804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
417 FIGURE 804.2(1) C-SHAPED SECTION
FIGURE 804.2(2) TRACK SECTION
418 FIGURE 804.2.5.1 WEB HOLES
FIGURE 804.2.5.3 WEB HOLE PATCH
419 FIGURE 804.3 STEEL ROOF CONSTRUCTION
TABLE 804.3 ROOF FRAMING FASTENING SCHEDULEa, b
420 TABLE 804.3.1.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL
421 TABLE 804.3.1.1(2) CEILING JOIST SPANSTWO EQUAL SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL
422 TABLE 804.3.1.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL
423 TABLE 804.3.1.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL
424 TABLE 804.3.1.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL
425 TABLE 804.3.1.1(6) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL
426 TABLE 804.3.1.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL
427 TABLE 804.3.1.1(8) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL
428 FIGURE 804.3.1.1(1) JOIST TO RAFTER CONNECTION
TABLE 804.3.1.1(9) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
429 FIGURE 804.3.1.1(2) BEARING STIFFENER
430 FIGURE 804.3.1.4(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL
431 FIGURE 804.3.1.4(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
FIGURE 804.3.1.5 SPLICED CEILING JOISTS
432 TABLE 804.3.2.1(1) ROOF RAFTER SPANSa, b, c 33 ksi STEEL
433 TABLE 804.3.2.1(2) ROOF RAFTER SPANSa, b, c 50 ksi STEEL
434 TABLE 804.3.2.1(3) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
FIGURE 804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
FIGURE 804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
435 TABLE 804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTER TO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
FIGURE 804.3.2.4 HIP MEMBER OR RIDGE MEMBER CONNECTION
436 TABLE 804.3.3.2 HIP MEMBER SIZES, 33 ksi STEEL
TABLE 804.3.3.3 HIP SUPPORT COLUMN SIZES
437 TABLE 804.3.3.4(1) UPLIFT STRAP CONNECTION REQUIREMENTS HIP SUPPORT COLUMN AT CEILING LINE
FIGURE 804.3.3.4(1) JACK RAFTER CONNECTION AT EAVE
438 TABLE 804.3.3.4(2) CONNECTION REQUIREMENTSHIP MEMBER TO HIP SUPPORT COLUMN
FIGURE 804.3.3.4(2) HIP SUPPORT COLUMN
439 TABLE 804.3.3.4(3) UPLIFT STRAP CONNECTION REQUIREMENTS HIP MEMBER TO WALL
FIGURE 804.3.3.4(3) HIP CONNECTIONS AT RIDGE
440 FIGURE 804.3.3.4(4) HIP CONNECTIONS AT RIDGE AND BOX COLUMN
441 FIGURE 804.3.3.4(5) HIP MEMBER CONNECTION AT WALL CORNER
442 FIGURE 804.3.6(1) ROOF OR CEILING OPENING
FIGURE 804.3.6(2) HEADER TO TRIMMER CONNECTION
443 TABLE 804.3.8(1) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FT a, b, c, d, e, f
FIGURE 804.3.8(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
444 TABLE 804.3.8(2) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED CEILING HEIGHT = 9 OR 10 FTa, b, c, d, e, f
FIGURE 804.3.8(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
445 TABLE 804.3.8(3) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS WOOD STRUCTURAL PANEL SHEATHED CEILING HEIGHT = 8, 9 OR 10 FTa, b, c, d
446 FIGURE 804.3.8(3) ROOF BLOCKING DETAIL
SECTION 805 CEILING FINISHES
SECTION 806 ROOF VENTILATION
447 TABLE 806.4 INSULATION FOR CONDENSATION CONTROL
SECTION 807 ATTIC ACCESS
449 CHAPTER 9 ROOF ASSEMBLIES
SECTION 901 GENERAL
SECTION 902 ROOF CLASSIFICATION
SECTION 903 WEATHER PROTECTION
SECTION 904 MATERIALS
450 FIGURE 903.5 HAIL EXPOSURE MAP
451 SECTION 905 REQUIREMENTS FOR ROOF COVERINGS
TABLE 905.2.4.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158
TABLE 905.2.4.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
452 TABLE 905.2.8.2 VALLEY LINING MATERIAL
453 TABLE 905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
454 TABLE 905.6.5 SLATE SHINGLE HEADLAP
455 TABLE 905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
456 TABLE 905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
457 TABLE 905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 905.10.3(2) MINIMUM CORROSION RESISTANCE
458 TABLE 905.10.3(1) METAL ROOF COVERINGS STANDARDS
TABLE 905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
459 SECTION 906 ROOF INSULATION
TABLE 906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 907 REROOFING
461 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION 1001 MASONRY FIREPLACES
462 TABLE 1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
463 FIGURE 1001.1 FIREPLACE AND CHIMNEY DETAILS
464 FIGURE 1001.11 CLEARANCE FROM COMBUSTIBLES
465 SECTION 1002 MASONRY HEATERS
SECTION 1003 MASONRY CHIMNEYS
467 TABLE 1003.14(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 1003.14(2) NET CROSS–SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
468 FIGURE 1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
469 FIGURE 1003.18 CLEARANCE FROM COMBUSTIBLES
TABLE 1003.20 CRICKET DIMENSIONS
FIGURE 1003.20 CHIMNEY CRICKET
470 SECTION 1004 FACTORY-BUILT FIREPLACES
SECTION 1005 FACTORY-BUILT CHIMNEYS
SECTION 1006 EXTERIOR AIR SUPPLY
471 PART IV – ENERGY CONSERVATION
CHAPTER 11 ENERGY EFFICIENCY
SECTION 1101 GENERAL
FIGURE 1101.2 CLIMATE ZONES
TABLE 1101.2 CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY COUNTY AND TERRITORY
472 TABLE 1101.5(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE 1101.5(2) DEFAULT DOOR U-FACTORS
TABLE 1101.5(3) DEFAULT GLAZED FENESTRATION SHGC
SECTION 1102 BUILDING THERMAL ENVELOPE
473 TABLE 1102.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE 1102.1.2 EQUIVALENT U-FACTORSa
474 TABLE 1102.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
476 TABLE 1102.4.2 AIR BARRIER AND INSULATION INSPECTION
SECTION 1103 SYSTEMS
477 SECTION 1104 LIGHTING SYSTEMS
SECTION 1105 OHIO HOME BUILDERS ASSOCIATION (OHBA) ALTERNATIVE ENERGY CODE OPTION
478 TABLE 1105.1.5(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE 1105.1.5(2) DEFAULT DOOR U-FACTORS
TABLE 1105.1.5 (3) DEFAULT GLAZED FENESTRATION SHGC
479 TABLE 1105.2.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a
TABLE 1105.2.1.2 EQUIVALENT U-FACTORS
480 TABLE 1105.2.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE
482 TABLE 1105.3.2.2(a) POST-CONSTRUCTION DUCT TIGHTNESS TESTING
TABLE 1105.3.2.2(b) ROUGH-IN DUCT TIGHTNESS TESTING
485 PART V – MECHANICAL
CHAPTER 12 MECHANICAL ADMINISTRATION
SECTION 1201 GENERAL
SECTION 1202 EXISTING MECHANICAL SYSTEMS
487 CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS
SECTION 1301 GENERAL
SECTION 1302 APPROVAL
SECTION 1303 LABELING OF APPLIANCES
SECTION 1304 TYPE OF FUEL
SECTION 1305 APPLIANCE ACCESS
488 SECTION 1306 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
SECTION 1307 APPLIANCE INSTALLATION
489 TABLE 1306.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa, c, d, e, f, g, h, I, j, k, l
490 FIGURE 1306.1 REDUCED CLEARANCE DIAGRAM
FIGURE 1306.2 WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
491 SECTION 1308 MECHANICAL SYSTEMS INSTALLATION
493 CHAPTER 14 HEATING AND COOLING EQUIPMENT
SECTION 1401 GENERAL
SECTION 1402 CENTRAL FURNACES
SECTION 1403 HEAT PUMP EQUIPMENT
SECTION 1404 REFRIGERATION COOLING EQUIPMENT
SECTION 1405 BASEBOARD CONVECTORS
SECTION 1406 RADIANT HEATING SYSTEMS
494 SECTION 1407 DUCT HEATERS
SECTION 1408 VENTED FLOOR FURNACES
SECTION 1409 VENTED WALL FURNACES
495 SECTION 1410 VENTED ROOM HEATERS
SECTION 1411 HEATING AND COOLING EQUIPMENT
496 SECTION 1412 ABSORPTION COOLING EQUIPMENT
SECTION 1413 EVAPORATIVE COOLING EQUIPMENT
SECTION 1414 FIREPLACE STOVES
SECTION 1415 MASONRY HEATERS
497 CHAPTER 15 EXHAUST SYSTEMS
SECTION 1501 GENERAL
SECTION 1502 CLOTHES DRYER EXHAUST
TABLE 1502.4.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
498 SECTION 1503 RANGE HOODS
SECTION 1504 INSTALLATION OF MICROWAVE OVENS
SECTION 1505 OVERHEAD EXHAUST HOODS
SECTION 1506 EXHAUST DUCTS
SECTION 1507 MECHANICAL VENTILATION
TABLE 1507.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE-, TWO- AND THREE-FAMILY DWELLINGS
499 CHAPTER 16 DUCT SYSTEMS
SECTION 1601 DUCT CONSTRUCTION
TABLE 1601.1.1(1) CLASSIFICATION OF FACTORY-MADE AIR DUCTS
TABLE 1601.1.1(2) GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING
501 SECTION 1602 RETURN AIR
503 CHAPTER 17 COMBUSTION AIR
SECTION 1701 GENERAL
505 CHAPTER 18 CHIMNEYS AND VENTS
SECTION 1801 GENERAL
SECTION 1802 VENT COMPONENTS
506 SECTION 1803 CHIMNEY AND VENT CONNECTORS
TABLE 1803.2 THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS
TABLE 1803.3.4 CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa
507 SECTION 1804 VENTS
TABLE 1804.1 VENT SELECTION CHART
SECTION 1805 MASONRY AND FACTORY-BUILT CHIMNEYS
509 CHAPTER 19 SPECIAL FUEL-BURNING EQUIPMENT
SECTION 1901 RANGES AND OVENS
SECTION 1902 SAUNA HEATERS
SECTION 1903 STATIONARY FUEL CELL POWER PLANTS
SECTION 1904 GASEOUS HYDROGEN SYSTEMS
511 CHAPTER 20 BOILERS AND WATER HEATERS
SECTION 2001 BOILERS
SECTION 2002 OPERATING AND SAFETY CONTROLS
SECTION 2003 EXPANSION TANKS
SECTION 2004 WATER HEATERS USED FOR SPACE HEATING
SECTION 2005 WATER HEATERS
512 TABLE 2003.2 EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT-WATER SYSTEMS
SECTION 2006 POOL HEATERS
513 CHAPTER 21 HYDRONIC PIPING
SECTION 2101 HYDRONIC PIPING SYSTEMS INSTALLATION
SECTION 2102 BASEBOARD CONVECTORS
SECTION 2103 FLOOR HEATING SYSTEMS
514 TABLE 2101.1 HYDRONIC PIPING MATERIALS
515 TABLE 2101.9 HANGER SPACING INTERVALS
SECTION 2104 LOW TEMPERATURE PIPING
516 SECTION 2105 GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING
517 CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION 2201 OIL TANKS
SECTION 2202 OIL PIPING, FITTING AND CONNECTIONS
SECTION 2203 INSTALLATION
518 SECTION 2204 OIL PUMPS AND VALVES
519 CHAPTER 23 SOLAR SYSTEMS
SECTION 2301 SOLAR ENERGY SYSTEMS
521 PART VI – FUEL GAS
CHAPTER 24 FUEL GAS
SECTION 2401 GENERAL
SECTION 2402 GENERAL
SECTION 2403 GENERAL DEFINITIONS
527 SECTION 2404 GENERAL
SECTION 2405 STRUCTURAL SAFETY
SECTION 2406 APPLIANCE LOCATION
528 SECTION 2407 COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 24-1
EQUATION 24-2
529 FIGURE 2407.5.3 ALL AIR FROM INSIDE THE BUILDING
FIGURE 2407.6.2 SINGLE COMBUSTION AIR OPENING,ALL AIR FROM OUTDOORS
530 FIGURE 2407.6.1(1) ALL AIR FROM OUTDOOR-INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
FIGURE 2407.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
531 FIGURE 2407.6.1(3) ALL AIR FROM OUTDOORS
532 SECTION 2408 INSTALLATION
SECTION 2409 CLEARANCE REDUCTION
533 FIGURE 2409.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTORS
FIGURE 2409.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
534 FIGURE 2409.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
535 TABLE 2409.2 (308.2)a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
536 SECTION 2410 ELECTRICAL
SECTION 2411 ELECTRICAL BONDING
SECTION 2412 GENERAL
SECTION 2413 PIPE SIZING
537 TABLE 2413.2 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
EQUATION 24-3
TABLE 2413.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
EQUATION 24-4
538 TABLE 2413.4(1) SCHEDULE 40 METALLIC PIPE
539 TABLE 2413.4(2) SCHEDULE 40 METALLIC PIPE
540 TABLE 2413.4(3) SEMIRIGID COPPER TUBING
541 TABLE 2413.4(4) SEMIRIGID COPPER TUBING
542 TABLE 2413.4(5) CORRUGATED STAINLESS STEEL TUBING (CSST)
543 TABLE 2413.4(6) CORRUGATED STAINLESS STEEL TUBING (CSST)
544 TABLE 2413.4(7) POLYETHYLENE PLASTIC PIPE
545 TABLE 2413.4(8) POLYETHYLENE PLASTIC PIPE
546 TABLE 2413.4(9) SCHEDULE 40 METALLIC PIPE
547 TABLE 2413.4(10) SCHEDULE 40 METALLIC PIPE
548 TABLE 2413.4(11) SCHEDULE 40 METALLIC PIPE
549 TABLE 2413.4(12) SCHEDULE 40 METALLIC PIPE
550 TABLE 2413.4(13) SEMIRIGID COPPER TUBING
551 TABLE 2413.4(14) SEMIRIGID COPPER TUBING
552 TABLE 2413.4(15) SEMIRIGID COPPER TUBING
553 TABLE 2413.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
554 TABLE 2413.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
555 TABLE 2413.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
556 TABLE 2413.4(19) POLYETHYLENE PLASTIC PIPE
557 TABLE 2413.4(20) POLYETHYLENE PLASTIC PIPE
558 TABLE 2413.4(21) POLYETHYLENE PLASTIC TUBING
SECTION 2414 PIPING MATERIALS
559 TABLE 2414.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
560 SECTION 2415 PIPING SYSTEM INSTALLATION
562 SECTION 2416 PIPING BENDS AND CHANGES IN DIRECTION
SECTION 2417 INSPECTION, TESTING AND PURGING
563 TABLE 2417.7.1.1 SIZE AND LENGTH OF PIPING
564 SECTION 2418 PIPING SUPPORT
SECTION 2419 DRIPS AND SLOPED PIPING
SECTION 2420 GAS SHUTOFF VALVES
565 TABLE 2420.1.1 MANUAL GAS VALVE STANDARDS
SECTION 2421 FLOW CONTROLS
566 SECTION 2422 APPLIANCE CONNECTIONS
SECTION 2423 CNG GAS-DISPENSING SYSTEMS
SECTION 2424 PIPING SUPPORT INTERVALS
TABLE 2424.1 SUPPORT OF PIPING
567 SECTION 2425 GENERAL
568 SECTION 2426 VENTS
SECTION 2427 VENTING OF APPLIANCES
569 TABLE 2427.4 TYPE OF VENTING SYSTEM TO BE USED
570 FIGURE 2427.5.3 (503.5.4) TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT APPLIANCES
573 FIGURE 2427.6.3 GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
575 TABLE 2427.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
576 TABLE 2427.10.5a CLEARANCES FOR CONNECTORS
578 SECTION 2428 SIZING OF CATEGORY IAPPLIANCE VENTING SYSTEMS
579 TABLE 2428.2(1) TYPE B DOUBLE-WALL GAS VENT
580 TABLE 2428.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
581 TABLE 2428.2(2) TYPE B DOUBLE-WALL GAS VENT
582 TABLE 2428.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
584 TABLE 2428.3(1) TYPE B DOUBLE-WALL VENT
585 TABLE 2428.3(2) TYPE B DOUBLE-WALL VENT
586 TABLE 2428.3(3) MASONRY CHIMNEY
587 TABLE 2428.3(4) MASONRY CHIMNEY
588 TABLE 2428.3.2 MAXIMUM VENT CONNECTOR LENGTH
590 SECTION 2429 DIRECT-VENT, INTEGRAL VENT,MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 2430 FACTORY-BUILT CHIMNEYS
SECTION 2431 GENERAL
SECTION 2432 DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 2433 LOG LIGHTERS
SECTION 2434 VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 2435 VENTED GAS FIREPLACE HEATERS
SECTION 2436 VENTED WALL FURNACES
591 SECTION 2437 FLOOR FURNACES
SECTION 2438 CLOTHES DRYERS
SECTION 2439 CLOTHES DRYER EXHAUST
592 SECTION 2440 SAUNA HEATERS
TABLE 2439.5.5.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
593 SECTION 2441 POOL AND SPA HEATERS
SECTION 2442 FORCED-AIR WARM-AIR FURNACES
594 SECTION 2443 CONVERSION BURNERS
SECTION 2444 UNIT HEATERS
SECTION 2445 UNVENTED ROOM HEATERS
SECTION 2446 VENTED ROOM HEATERS
595 SECTION 2447 COOKING APPLIANCES
SECTION 2448 WATER HEATERS
SECTION 2449 AIR CONDITIONING APPLIANCES
SECTION 2450 ILLUMINATING APPLIANCES
SECTION 2451 INFRARED RADIANT HEATERS
596 SECTION 2452 BOILERS
SECTION 2453 CHIMNEY DAMPER OPENING AREA
TABLE 2453.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
597 PART VII – PLUMBING
CHAPTER 25 PLUMBING SYSTEMS
599 CHAPTERS 26 – 28 NOT USED. REFER TO CHAPTER 25
601 CHAPTER 29 WATER SUPPLY AND DISTRIBUTION
SECTION 2901 GENERAL
SECTION 2902 PROTECTION OF POTABLE WATER SUPPLY
SECTION 2903 WATER SUPPLY SYSTEM
SECTION 2904 DWELLING UNIT FIRE SPRINKLER SYSTEMS
TABLE 2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
602 FIGURE 2903.10 TYPICAL FROSTPROOF HOSE BIB INSTALATION NOT REQUIRING SEPARATE VALUE
603 EQUATION 29-1
604 SECTION 2905 MATERIALS, JOINTS AND CONNECTIONS
SECTION 2906 CHANGES IN DIRECTION
SECTION 2907 SUPPORT
SECTION 2908 DRINKING WATER TREATMENT UNITS
605 TABLE 2904.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a,b
606 TABLE 2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
TABLE 2904.6.2(3) ELEVATION LOSS (PLe)
607 TABLE 2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBI
608 TABLE 2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
609 TABLE 2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
610 TABLE 2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
611 TABLE 2904.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX TUBING
612 TABLE 2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX TUBING
613 CHAPTERS 30 – 33 NOT USED. REFER TO CHAPTER 25
615 CHAPTER 34 GENERAL REQUIREMENTS
SECTION 3401 ELECTRICAL
617 CHAPTER 35 – 43 NOT USED. REFER TO CHAPTER 34
619 PART IX – REFERENCED STANDARDS
CHAPTER 44 REFERENCED STANDARDS
AAMA
ACI
ACCA
620 AFPA
AISI
AITC
ANSI
621 APA
ASCE/SEI
ASHRAE
622 ASME
ASTM
626 AWPA
627 CGSB
CPA
CPSC
CSA
CSSB
628 DASMA
DOC
DOTn
FEMA
FM
GA
629 HPVA
ICC
ISO
MSS
NAIMA
NCMA
630 NFPA
NFRC
PCA
SMACNA
TMS
631 TPI
UL
632 ULC
US-FTC
WDMA
633 INDEX
643 SERVICES OF THE ICC
644 GET IMMEDIATE DOWNLOADS OF THE STANDARDS YOU NEED
HELPFUL LINKS
Residential Code of Ohio 2013
$61.10