Shopping Cart

No products in the cart.

OR OregonMechanicalCode 2019

$72.04

Oregon Mechanical Specialty Code

Published By Publication Date Number of Pages
OR 2019 325
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2018 International Mechanical Code®. Effective date: October 1, 2019.

PDF Catalog

PDF Pages PDF Title
1 2019 OREGON MECHANICAL SPECIALTY CODE
2 2019 OREGON MECHANICAL SPECIALTY CODE BASED ON THE 2018 INTERNATIONAL MECHANICAL CODE® AND THE 2018 INTERNATIONAL FUEL GAS CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE OREGON MECHANICAL SPECIALTY CODE
11 EFFECTIVE USE OF APPENDIX C—FUEL GAS
14 TABLE OF CONTENTS
18 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
20 PART 2–ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION
21 SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL
22 SECTION 105 APPROVAL
SECTION 106 PERMITS
26 SECTION 107 INSPECTIONS AND TESTING
27 SECTION 108 VIOLATIONS
29 SECTION 109 BOARD OF APPEALS
SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES
30 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
42 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
43 SECTION 302 PROTECTION OF STRUCTURE
44 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
46 FIGURE 304.1 ILLUSTRATIONS OF NORMAL VEHICLE PATH AND RECOMMENDED TYPES OF PROTECTION
47 SECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
49 SECTION 307 CONDENSATE DISPOSAL
TABLE 307.2.2 CONDENSATE DRAIN SIZING
50 SECTION 308 CLEARANCE REDUCTION
51 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
SECTION 309 TEMPERATURE CONTROL
SECTION 310 HEATING AND COOLING LOAD CALCULATIONS
52 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR IN TAKE OPENINGS
SECTION 402 NATURAL VENTILATION
53 SECTION 403 MECHANICAL VENTILATION
54 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
55 EQUATION 4-5
TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
56 EQUATION 4-9
TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3, AND R-4 OCCUPANCIES
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
57 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
58 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
59 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
60 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
62 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
63 SECTION 502 REQUIRED SYSTEMS
EQUATION 5-1
69 SECTION 503 MOTORS AND FANS
70 SECTION 504 CLOTHES DRYER EXHAUST
71 TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT
72 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
77 SECTION 507 COMMERCIAL KITCHEN HOODS
79 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
80 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
81 SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
83 TABLE 510.9 MINIMUM DUCT THICKNESS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
84 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
86 EQUATION 5-2
87 EQUATION 5-3
88 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
90 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
91 SECTION 602 PLENUMS
93 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITS
95 SECTION 604 INSULATION
SECTION 605 AIR FILTERS
96 SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
SECTION 607 DUCT AND TRANSFER OPENINGS
97 TABLE 607.3.2.1 FIRE DAMPER RATING
102 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
104 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
105 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
106 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
107 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
108 SECTION 805 FACTORY-BUILT CHIMNEYS
109 SECTION 806 METAL CHIMNEYS
110 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
111 SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
112 SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
113 SECTION 918 FORCED-AIR WARM-AIR FURNACES
SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
114 SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 EVAPORATIVE COOLING EQUIPMENT
SECTION 928 HIGH-VOLUME LARGE-DIAMETER FANS
SECTION 929 SOLID FUEL-BURNING DEVICES
116 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 BOILERS AND PRESSURE VESSELS
SECTION 1004 PERMITS REQUIRED
SECTION 1005 DETAILED REQUIREMENTS
117 SECTION 1006 EXPANSION TANKS
SECTION 1007 SAFETY OR RELIEF VALVE DISCHARGE
SECTION 1008 GAS PRESSURE REGULATORS
SECTION 1009 CLEARANCE FOR ACCESS
SECTION 1010 BOILER ROOM ENCLOSURES
SECTION 1011 FLOORS
SECTION 1012 CHIMNEYS OR VENTS
SECTION 1013 DRAINAGE
SECTION 1014 FUEL SUPPLY PIPING
SECTION 1015 AIR FOR COMBUSTION AND VENTILATION
SECTION 1016 STEAM AND HOT WATER PIPING
118 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS
119 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
120 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
121 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
122 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
123 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
124 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
126 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
127 EQUATION 11-1
EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
128 TABLE 1106.5.2 MINIMUM EXHAUST RATES
SECTION 1107 REFRIGERANT PIPING
129 SECTION 1108 FIELD TEST
132 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
133 TABLE 1202.5 HYDRONIC PIPE FITTINGS
SECTION 1203 JOINTS AND CONNECTIONS
135 SECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
136 SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
137 TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
140 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS
141 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
SECTION 1306 OIL GAUGING
142 SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
144 CHAPTER 14 SOLAR THERMAL SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 DESIGN AND INSTALLATION
146 SECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 LABELING
148 CHAPTER 15 REFERENCED STANDARDS
ACCA
AHRI
AMCA
ANSI
149 ASHRAE
ASME
150 ASSE
ASSE
ASTM
153 AWS
154 AWWA
CPSC
CSA
155 DOL
FDA
FS
ICC
IIAR
156 MSS
NAIMA
NFPA
157 NSF
SMACNA
UL
162 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
163 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
164 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
166 INDEX
172 APPENDIX C FUEL GAS
SECTION C101 SCOPE AND ADMINISTRATION
SECTION C102 INSPECTIONS AND TESTING
173 SECTION C103 TEMPORARY EQUIPMENT, SYSTEMS AND USES
174 SECTION C201 FUEL GAS DEFINITIONS
SECTION C202 DEFINITIONS
179 SECTION C301 GENERAL REGULATIONS
SECTION C302 STRUCTURAL SAFETY
SECTION C303 APPLIANCE LOCATION
180 SECTION C304 COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION C3-1
EQUATION C3-2
181 FIGURE C304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section C304.5.3)
FIGURE C304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section C304.6.1)
182 FIGURE C304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section C304.6.1)
FIGURE C304.6.1(3) ALL AIR FROM OUTDOORS (see Section C304.6.1)
FIGURE C304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section C304.6.2)
FIGURE C304.6.2 SINGLE COMBUSTION AIR OPENING,ALL AIR FROM THE OUTDOORS
183 SECTION C305 INSTALLATION
184 SECTION C306 ACCESS AND SERVICE SPACE
185 SECTION C307 CONDENSATE DISPOSAL
186 SECTION C308 CLEARANCE REDUCTION
SECTION C309 ELECTRICAL
SECTION C310 ELECTRICAL BONDING
187 TABLE C308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
188 FIGURE C308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE C308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE C308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
189 SECTION C401 GAS PIPING INSTALLATIONS
SECTION C402 PIPE SIZING
EQUATION C4-1
190 EQUATION C4-2
TABLE C402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
191 TABLE C402.4(1) SCHEDULE 40 METALLIC PIPE
192 TABLE C402.4(2) SCHEDULE 40 METALLIC PIPE
193 TABLE C402.4(3) SCHEDULE 40 METALLIC PIPE
194 TABLE C402.4(4) SCHEDULE 40 METALLIC PIPE
195 TABLE C402.4(5) SCHEDULE 40 METALLIC PIPE
196 TABLE C402.4(6) SCHEDULE 40 METALLIC PIPE
197 TABLE C402.4(7) SCHEDULE 40 METALLIC PIPE
198 TABLE C402.4(8) SEMIRIGID COPPER TUBING
199 TABLE C402.4(9) SEMIRIGID COPPER TUBING
200 TABLE C402.4(10) SEMIRIGID COPPER TUBING
201 TABLE C402.4(11) SEMIRIGID COPPER TUBING
202 TABLE C402.4(12) SEMIRIGID COPPER TUBING
203 TABLE C402.4(13) SEMIRIGID COPPER TUBING
204 TABLE C402.4(14) SEMIRIGID COPPER TUBING
205 TABLE C402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
206 TABLE C402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
207 TABLE C402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
208 TABLE C402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
209 TABLE C402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
210 TABLE C402.4(20) POLYETHYLENE PLASTIC PIPE
211 TABLE C402.4(21) POLYETHYLENE PLASTIC PIPE
212 TABLE C402.4(22) POLYETHYLENE PLASTIC PIPE
213 TABLE C402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE C402.4(24) POLYETHYLENE PLASTIC TUBING
214 TABLE C402.4(25) SCHEDULE 40 METALLIC PIPE
215 TABLE C402.4(26) SCHEDULE 40 METALLIC PIPE
216 TABLE C402.4(27) SCHEDULE 40 METALLIC PIPE
217 TABLE C402.4(28) SCHEDULE 40 METALLIC PIPE
218 TABLE C402.4(29) SEMIRIGID COPPER TUBING
219 TABLE C402.4(30) SEMIRIGID COPPER TUBING
220 TABLE C402.4(31) SEMIRIGID COPPER TUBING
221 TABLE C402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
222 TABLE C402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
223 TABLE C402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
224 TABLE C402.4(35) POLYETHYLENE PLASTIC PIPE
225 TABLE C402.4(36) POLYETHYLENE PLASTIC PIPE
226 TABLE C402.4(37) POLYETHYLENE PLASTIC TUBING
227 SECTION C403 PIPING MATERIALS
228 TABLE C403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
229 SECTION C404 PIPING SYSTEM INSTALLATION
231 SECTION C405 PIPING BENDS AND CHANGES IN DIRECTION
232 SECTION C406 INSPECTION, TESTING AND PURGING
233 SECTION C407 PIPING SUPPORT
SECTION C408 DRIPS AND SLOPED PIPING
FIGURE C408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION C409 SHUTOFF VALVES
234 TABLE C409.1.1 MANUAL GAS VALVE STANDARDS
SECTION C410 FLOW CONTROLS
235 SECTION C411 APPLIANCE AND MANUFACTURED HOME CONNECTIONS
236 SECTION C412 LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION C413 COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION C414 SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION C415 PIPING SUPPORT INTERVALS
237 TABLE C415.1 SUPPORT OF PIPING
SECTION C416 FUEL-GAS EQUIPMENT AND INSTALLATIONS IN MANUFACTURED STRUCTURE (MOBILE HOME OR RECREATIONAL VEHICLE) PARKS
SECTION C417 OVERPRESSURE PROTECTION DEVICES
239 SECTION C501 CHIMNEYS AND VENTS
240 SECTION C502 VENTS
SECTION C503 VENTING OF APPLIANCES
242 TABLE C503.4 TYPE OF VENTING SYSTEM TO BE USED
244 FIGURE C503.6.5 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE NOT LESS THAN 8 FEET FROM A VERTICAL WALL
246 TABLE C503.8 THROUGH-THE-WALL, DIRECT-VENT TERMINATION CLEARANCES
247 TABLE C503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE C503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
249 TABLE C503.10.5 CLEARANCES FOR CONNECTORSa
250 SECTION C504 SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
252 TABLE C504.3.2 MAXIMUM VENT CONNECTOR LENGTH
254 SECTION C505 DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION C506 FACTORY-BUILT CHIMNEYS
255 TABLE C504.2(1) TYPE B DOUBLE-WALL GAS VENT
256 TABLE C504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
257 TABLE C504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
258 TABLE C504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
259 TABLE C504.2(2) TYPE B DOUBLE-WALL GAS VENT
260 TABLE C504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
261 TABLE C504.2(3) MASONRY CHIMNEY
262 TABLE C504.2(3)—continued MASONRY CHIMNEY
263 TABLE C504.2(4) MASONRY CHIMNEY
264 TABLE C504.2(4)—continued MASONRY CHIMNEY
265 TABLE C504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
266 TABLE C504.2(6) EXTERIOR MASONRY CHIMNEY
267 TABLE C504.3(1) TYPE B DOUBLE-WALL VENT
268 TABLE C504.3(1)—continued TYPE B DOUBLE-WALL VENT
269 TABLE C504.3(2) TYPE B DOUBLE-WALL VENT
270 TABLE C504.3(3) MASONRY CHIMNEY
271 TABLE C504.3(4) MASONRY CHIMNEY
272 TABLE C504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
273 TABLE C504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(6b) EXTERIOR MASONRY CHIMNEY—continued
274 TABLE C504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
275 SECTION C601 SPECIFIC APPLIANCES
SECTION C602 DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION C603 LOG LIGHTERS
SECTION C604 VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION C605 VENTED GAS FIREPLACE HEATERS
SECTION C606 INCINERATORS AND CREMATORIES
SECTION C607 COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION C608 VENTED WALL FURNACES
SECTION C609 FLOOR FURNACES
276 SECTION C610 DUCT FURNACES
SECTION C611 NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
277 SECTION C612 RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION C613 CLOTHES DRYERS
SECTION C614 CLOTHES DRYER EXHAUST
SECTION C615 SAUNA HEATERS
SECTION C616 ENGINE AND GAS TURBINE-POWERED EQUIPMENT
278 SECTION C617 POOL AND SPA HEATERS
SECTION C618 FORCED-AIR WARM-AIR FURNACES
SECTION C619 CONVERSION BURNERS
279 SECTION C620 UNIT HEATERS
SECTION C621 UNVENTED ROOM HEATERS
SECTION C622 VENTED ROOM HEATERS
SECTION C623 COOKING APPLIANCES
280 SECTION C624 WATER HEATERS
SECTION C625 REFRIGERATORS
SECTION C626 GAS-FIRED TOILETS
SECTION C627 AIR-CONDITIONING APPLIANCES
281 SECTION C628 ILLUMINATING APPLIANCES
SECTION C629 SMALL CERAMIC KILNS
SECTION C630 INFRARED RADIANT HEATERS
282 SECTION C631 BOILERS
SECTION C632 RESERVED
SECTION C633 STATIONARY FUEL-CELL POWER SYSTEMS
SECTION C634 CHIMNEY DAMPER OPENING AREA
TABLE C634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION C635 GASEOUS HYDROGEN SYSTEMS
SECTION C636 OUTDOOR DECORATIVE APPLIANCES
283 SECTION C701 GASEOUS HYDROGEN STSYEMS
SECTION C702 GENERAL DEFINITIONS
SECTION C703 GENERAL REQUIREMENTS
284 SECTION C704 PIPING, USE AND HANDLING
285 SECTION C705 TESTING OF HYDROGEN PIPING SYSTEMS
286 SECTION C706 LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION C707 OPERATION OF GASEOUS HYDROGEN SYSTEMS
SECTION C708 DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
287 SECTION C801 REFERENCED STANDARDS
ANSI
288 ASME
289 ASTM
290 CGA
CSA
DOTn
MSS
NFPA
291 UL
292 APPENDIX C-A SIZING AND CAPACITIES OF GAS PIPING
C-A.1 GENERAL PIPING CONSIDERATIONS
C-A.2 DESCRIPTION OF TABLES
293 TABLE C-A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
294 TABLE C-A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
295 TABLE C-A.2.4 MULTIPLIERS TO BE USED WITH TABLES C402.4(1) THROUGH C402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
C-A.3 USE OF CAPACITY TABLES
297 TABLE C-A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
C-A.4 USE OF SIZING EQUATIONS
C-A.5 PIPE AND TUBE DIAMETERS
TABLE C-A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
298 TABLE C-A.5.2 COPPER TUBE STANDARD SIZES
C-A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
299 FIGURE C-A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE C-A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
300 FIGURE C-A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE C-A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
302 APPENDIX C-B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE C-B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE C-B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
303 FIGURE C-B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE C-B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE C-B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE C-B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
304 FIGURE C-B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE C-B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE C-B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT
FIGURE C-B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
305 FIGURE C-B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE C-B-12 USE OF OFFSET COMMON VENT
FIGURE C-B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE C-B-14 MULTISTORY VENT SYSTEMS
306 FIGURE C-B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE C-B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
307 EXAMPLES USING COMMON VENTING TABLES
FIGURE C-B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE C-B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
309 TABLE C-B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTS
310 FIGURE C-B-19
312 APPENDIX C-C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
FIGURE C-C-1 EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
314 APPENDIX C-D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
C-D.1 GENERAL
C-D.2 OCCUPANT AND INSPECTOR SAFETY
315 C-D.3 GAS PIPING AND CONNECTION INSPECTIONS
C-D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
316 C-D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
317 C-D.6 APPLIANCE-SPECIFIC INSPECTIONS
319 TABLE C-D.6 CO THRESHOLDS
320 APPENDIX C INDEX
324 ICC LEARNING CENTER
325 ICC ASSESSMENT CENTER
OR OregonMechanicalCode 2019
$72.04