Shopping Cart

No products in the cart.

OR PortlandFireCode 2016

$49.58

Portland Fire Code: Based on the 2012 International Fire Code and 2014 Oregon Fire Code – Amendments

Published By Publication Date Number of Pages
OR 2016 573
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The printed package includes the 2016 Portland Fire Code amendment pages for integration with the 2014 Oregon Fire Code.

PDF Catalog

PDF Pages PDF Title
1 2016 PORTLAND FIRE CODE BASED ON THE 2012 INTERNATIONAL FIRE CODE® & 2014 OREGON FIRE CODE
2 2016 PORTLAND FIRE CODE: BASED ON THE 2012 INTERNATIONA FIRE CODE® & 2014 OREGON FIRE CODE – AMENDMENTS TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL FIRE CODE
22 LEGISLATION
24 TABLE OF CONTENTS
34 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—GENERAL PROVISIONS
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 APPLICABILITY
36 PART 2—ADMINISTRATIVE PROVISIONS
SECTION 103 DEPARTMENT OF FIRE PREVENTION
SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES
39 SECTION 105 PERMITS
42 TABLE 105.6.8 PERMIT AMOUNTS FOR COMPRESSED GASES
TABLE 105.6.10 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
44 TABLE 105.6.20 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
TABLE 105.6.20—continued PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
46 SECTION 106 INSPECTIONS
47 SECTION 107 MAINTENANCE
SECTION 108 BOARD OF APPEALS
48 SECTION 109 VIOLATIONS
49 SECTION 110 UNSAFE BUILDINGS
SECTION 111 STOP WORK ORDER
SECTION 112 SERVICE UTILITIES
50 SECTION 113 FEES
52 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
84 PART II—GENERAL SAFETY PROVISIONS
CHAPTER 3 GENERAL REQUIREMENTS
SECTION 301 GENERAL
SECTION 302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
SECTION 304 COMBUSTIBLE WASTE MATERIAL
85 SECTION 305 IGNITION SOURCES
86 SECTION 306 MOTION PICTURE PROJECTION ROOMS AND MOTION PICTURE AND TELEVISION PRODUCTION STUDIO SOUNDSTAGES AND APPROVED PRODUCTION FACILITIES AND FILM
SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
SECTION 308 OPEN FLAMES
88 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
SECTION 310 SMOKING
89 SECTION 311 VACANT PREMISES
90 SECTION 312 VEHICLE IMPACT PROTECTION
SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS
91 SECTION 315 GENERAL STORAGE
SECTION 316 HAZARDS TO FIRE FIGHTERS
92 SECTION 317 ROOFTOP GARDENS AND LANDSCAPED ROOFS
SECTION 318 LAUNDRY CARTS
SECTION 319 COLLECTION AND STORAGE OF COMBUSTIBLE RECYCLABLE MATERIALS
94 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION 401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS
95 SECTION 404 FIRE SAFETY AND EVACUATION PLANS
96 SECTION 405 EMERGENCY EVACUATION DRILLS
TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
97 SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
SECTION 407 HAZARD COMMUNICATION
SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS
102 PART III—BUILDING AND EQUIPMENT DESIGN FEATURES
CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS
103 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
104 SECTION 505 PREMISES IDENTIFICATION
SECTION 506 KEY BOXES
SECTION 507 FIRE PROTECTION WATER SUPPLIES
105 SECTION 508 FIRE COMMAND CENTER
106 SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
107 SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE
110 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
SECTION 603 FUEL-FIRED APPLIANCES
113 SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS
115 SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
116 SECTION 606 MECHANICAL REFRIGERATION
118 SECTION 607 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
119 SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS
TABLE 608.1 BATTERY REQUIREMENTS
121 SECTION 609 COMMERCIAL KITCHEN HOODS
TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY
122 SECTION 610 COMMERCIAL KITCHEN COOKING OIL STORAGE
124 CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION
125 SECTION 704 FLOOR OPENINGS AND SHAFTS
126 CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS
127 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk, m
128 SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS
129 SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
132 SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
133 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
136 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
137 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
138 SECTION 902 DEFINITIONS
139 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
140 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
143 TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
145 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
148 SECTION 905 STANDPIPE SYSTEMS
150 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
151 SECTION 906 PORTABLE FIRE EXTINGUISHERS
TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
152 TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
161 TABLE 907.5.2.3.3 VISIBLE ALARMS
163 SECTION 908 EMERGENCY ALARM SYSTEMS
164 SECTION 909 SMOKE CONTROL SYSTEMS
165 EQUATION 9-1
166 EQUATION 9-2
EQUATION 9-3
170 SECTION 910 SMOKE AND HEAT REMOVAL
171 TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
EQUATION 9-4
172 SECTION 911 EXPLOSION CONTROL
TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS
173 SECTION 912 FIRE DEPARTMENT CONNECTIONS
174 SECTION 913 FIRE PUMPS
SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
177 TABLE 914.8.2 HANGAR FIRE SUPPRESSION REQUIREMENTSa,b,c
178 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
179 [B] SECTION 1003 GENERAL MEANS OF EGRESS
180 [B] SECTION 1004 OCCUPANT LOAD
TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
181 SECTION 1005 MEANS OF EGRESS SIZING
182 [B] SECTION 1006 MEANS OF EGRESS ILLUMINATION
[B] SECTION 1007 ACCESSIBLE MEANS OF EGRESS
185 SECTION 1008 DOORS, GATES AND TURNSTILES
186 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
192 SECTION 1009 STAIRWAYS
196 SECTION 1010 RAMPS
197 SECTION 1011 EXIT SIGNS
198 SECTION 1012 HANDRAILS
199 SECTION 1013 GUARDS
201 SECTION 1014 EXIT ACCESS
[B] TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
202 SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
[B] TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
203 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
[B] TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1017 AISLES
204 SECTION 1018 CORRIDORS
[B] TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
205 [B] TABLE 1018.2 MINIMUM CORRIDOR WIDTH
SECTION 1019 EGRESS BALCONIES
206 SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION
[B] TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
207 [B] TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
208 SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
209 SECTION 1023 EXIT PASSAGEWAYS
210 SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
211 SECTION 1025 HORIZONTAL EXITS
212 SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
213 SECTION 1027 EXIT DISCHARGE
214 SECTION 1028 ASSEMBLY
215 [B] TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
217 [B] TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
218 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
219 SECTION 1030 MAINTENANCE OF THE MEANS OF EGRESS
222 CHAPTER 11 FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
SECTION 1101 GENERAL
SECTION 1102 DEFINITION
SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
223 TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa
228 SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS
229 TABLE 1104.9 REVOLVING DOOR SPEEDS
231 TABLE 1104.17.2 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
234 CHAPTERS 12 THROUGH 19 RESERVED
236 PART IV—SPECIAL OCCUPANCIES AND OPERATIONS
CHAPTER 20 AVIATION FACILITIES
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 AIRCRAFT MAINTENANCE
237 SECTION 2005 PORTABLE FIRE EXTINGUISHERS
SECTION 2006 AIRCRAFT FUELING
242 SECTION 2007 HELISTOPS AND HELIPORTS
244 CHAPTER 21 DRY CLEANING
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 CLASSIFICATIONS
SECTION 2104 GENERAL REQUIREMENTS
SECTION 2105 OPERATING REQUIREMENTS
245 EQUATION 21-1
SECTION 2106 SPOTTING AND PRETREATING
246 SECTION 2107 DRY CLEANING SYSTEMS
SECTION 2108 FIRE PROTECTION
248 CHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 2201 GENERAL
SECTION 2202 DEFINITION
SECTION 2203 PRECAUTIONS
SECTION 2204 EXPLOSION PROTECTION
TABLE 2204.1 EXPLOSION PROTECTION STANDARDS
SECTION 2205 DUST COLLECTION
250 CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 LOCATION OF DISPENSING DEVICES
251 SECTION 2304 DISPENSING OPERATIONS
252 SECTION 2305 OPERATIONAL REQUIREMENTS
253 SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
257 SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
258 SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
259 TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
261 SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES
262 SECTION 2311 REPAIR GARAGES
266 CHAPTER 24 FLAMMABLE FINISHES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 PROTECTION OF OPERATIONS
268 SECTION 2404 SPRAY FINISHING
271 SECTION 2405 DIPPING OPERATIONS
273 SECTION 2406 POWDER COATING
SECTION 2407 ELECTROSTATIC APPARATUS
274 SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
275 SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS
276 CHAPTER 25 FRUIT AND CROP RIPENING
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 ETHYLENE GAS
SECTION 2504 SOURCES OF IGNITION
SECTION 2505 COMBUSTIBLE WASTE
SECTION 2506 ETHYLENE GENERATORS
SECTION 2507 WARNING SIGNS
278 CHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FIRE SAFETY REQUIREMENTS
280 CHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 2701 GENERAL
SECTION 2702 DEFINITIONS
SECTION 2703 GENERAL SAFETY PROVISIONS
284 SECTION 2704 STORAGE
285 TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
286 TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
SECTION 2705 USE AND HANDLING
287 TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
290 CHAPTER 28 LUMBER YARDS AND WOODWORKING FACILITIES
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 GENERAL REQUIREMENTS
SECTION 2804 FIRE PROTECTION
291 SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 2806 LOG STORAGE AREAS
SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOSTAND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES
292 SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS
294 CHAPTER 29 MANUFACTURE OF ORGANIC COATINGS
SECTION 2901 GENERAL
SECTION 2902 DEFINITION
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION
295 SECTION 2905 PROCESS STRUCTURES
SECTION 2906 PROCESS MILLS AND KETTLES
SECTION 2907 PROCESS PIPING
SECTION 2908 RAW MATERIALS IN PROCESS AREAS
296 SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS
298 CHAPTER 30 INDUSTRIAL OVENS
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
SECTION 3003 LOCATION
SECTION 3004 FUEL PIPING
SECTION 3005 INTERLOCKS
SECTION 3006 FIRE PROTECTION
SECTION 3007 OPERATION AND MAINTENANCE
300 CHAPTER 31 TENTS AND OTHER MEMBRANE STRUCTURES
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
301 TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
302 SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
306 CHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 3201 GENERAL
SECTION 3202 DEFINITIONS
SECTION 3203 COMMODITY CLASSIFICATION
308 SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS
309 FIGURE 3203.7.4 MIXED COMMODITIESa, b
310 SECTION 3205 HOUSEKEEPING AND MAINTENANCE
SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
311 TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
312 SECTION 3207 SOLID-PILED AND SHELF STORAGE
SECTION 3208 RACK STORAGE
313 TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 3209 AUTOMATED STORAGE
314 SECTION 3210 SPECIALTY STORAGE
316 CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 DEFINITIONS
SECTION 3303 TEMPORARY HEATING EQUIPMENT
SECTION 3304 PRECAUTIONS AGAINST FIRE
SECTION 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS
317 SECTION 3306 FLAMMABLE GASES
SECTION 3307 EXPLOSIVE MATERIALS
SECTION 3308 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 3309 FIRE REPORTING
SECTION 3310 ACCESS FOR FIRE FIGHTING
318 SECTION 3311 MEANS OF EGRESS
SECTION 3312 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3313 STANDPIPES
SECTION 3314 AUTOMATIC SPRINKLER SYSTEM
SECTION 3315 PORTABLE FIRE EXTINGUISHERS
SECTION 3316 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3317 SAFEGUARDING ROOFING OPERATIONS
319 SECTION 3318 COMBUSTIBLE TRASH CHUTES
320 CHAPTER 34 TIRE REBUILDING AND TIRE STORAGE
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 TIRE REBUILDING
SECTION 3404 PRECAUTIONS AGAINST FIRE
SECTION 3405 OUTDOOR STORAGE
321 SECTION 3406 FIRE DEPARTMENT ACCESS
SECTION 3407 FENCING
SECTION 3408 FIRE PROTECTION
SECTION 3409 INDOOR STORAGE ARRANGEMENT
322 CHAPTER 35 WELDING AND OTHER HOT WORK
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
SECTION 3504 FIRE SAFETY REQUIREMENTS
323 SECTION 3505 GAS WELDING AND CUTTING
324 SECTION 3506 ELECTRIC ARC HOT WORK
SECTION 3507 CALCIUM CARBIDE SYSTEMS
SECTION 3508 ACETYLENE GENERATORS
SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
326 CHAPTER 36 MARINAS
SECTION 3601 SCOPE
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL PRECAUTIONS
SECTION 3604 FIRE PROTECTION EQUIPMENT
SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES
328 CHAPTERS 37 THROUGH 49 RESERVED
330 PART V—HAZARDOUS MATERIALS
CHAPTER 50 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION 5001 GENERAL
333 SECTION 5002 DEFINITIONS
SECTION 5003 GENERAL REQUIREMENTS
335 TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
336 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
337 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
338 TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARDa, b, c, h, i
339 TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREAa, b, c, d
340 TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREAa, b, c, f
343 TABLE 5003.8.2 DETACHED BUILDING REQUIRED
TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
347 TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES—NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd, e, f
348 SECTION 5004 STORAGE
349 TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
351 SECTION 5005 USE, DISPENSING AND HANDLING
353 TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
356 CHAPTER 51 AEROSOLS
SECTION 5101 GENERAL
SECTION 5102 DEFINITIONS
SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS
TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb
357 TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
358 TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 5105 OUTSIDE STORAGE
TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
SECTION 5106 RETAIL DISPLAY
359 TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
360 TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
SECTION 5107 MANUFACTURING FACILITIES
362 CHAPTER 52 COMBUSTIBLE FIBERS
SECTION 5201 GENERAL
SECTION 5202 DEFINITIONS
SECTION 5203 GENERAL PRECAUTIONS
SECTION 5204 LOOSE FIBER STORAGE
363 SECTION 5205 BALED STORAGE
364 CHAPTER 53 COMPRESSED GASES
SECTION 5301 GENERAL
SECTION 5302 DEFINITIONS
SECTION 5303 GENERAL REQUIREMENTS
367 SECTION 5304 STORAGE OF COMPRESSED GASES
368 SECTION 5305 USE AND HANDLING OF COMPRESSED GASES
SECTION 5306 MEDICAL GAS SYSTEMS
369 SECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED
370 CHAPTER 54 CORROSIVE MATERIALS
SECTION 5401 GENERAL
SECTION 5402 DEFINITION
SECTION 5403 GENERAL REQUIREMENTS
SECTION 5404 STORAGE
SECTION 5405 USE
372 CHAPTER 55 CRYOGENIC FLUIDS
SECTION 5501 GENERAL
SECTION 5502 DEFINITIONS
SECTION 5503 GENERAL REQUIREMENTS
374 SECTION 5504 STORAGE
TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
375 TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 5505 USE AND HANDLING
378 CHAPTER 56 EXPLOSIVES AND FIREWORKS
SECTION 5601 GENERAL
380 TABLE 5601.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVESa, b, c
TABLE 5601.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVESa, b, c
TABLE 5601.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVESa, b, c, d
381 SECTION 5602 DEFINITIONS
382 SECTION 5603 RECORD KEEPING AND REPORTING
SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING
383 TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
384 TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
385 TABLE 5604.5.2(1)-continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
386 TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARDa, b, c
TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4c
388 SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS
389 TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa
391 SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS
393 SECTION 5607 BLASTING
SECTION 5608 FIREWORKS DISPLAY
394 SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS
396 CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 5701 GENERAL
SECTION 5702 DEFINITIONS
397 SECTION 5703 GENERAL REQUIREMENTS
398 TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
399 TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
400 TABLE 5703.6.2 PIPING STANDARDS
401 SECTION 5704 STORAGE
412 TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa
413 TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
414 TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
415 TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKSa
416 TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
417 TABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS OR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
418 TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa
419 TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESSa, b
420 TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
421 SECTION 5705 DISPENSING, USE, MIXING AND HANDLING
422 TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
423 TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1)
425 TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREASa, b
427 SECTION 5706 SPECIAL OPERATIONS
438 CHAPTER 58 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 5801 GENERAL
SECTION 5802 DEFINITIONS
SECTION 5803 GENERAL REQUIREMENTS
439 SECTION 5804 STORAGE
SECTION 5805 USE
SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS
440 SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS
442 CHAPTER 59 FLAMMABLE SOLIDS
SECTION 5901 GENERAL
SECTION 5902 DEFINITIONS
SECTION 5903 GENERAL REQUIREMENTS
SECTION 5904 STORAGE
SECTION 5905 USE
SECTION 5906 MAGNESIUM
444 CHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 6001 GENERAL
SECTION 6002 DEFINITIONS
SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
445 SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
448 TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
449 SECTION 6005 OZONE GAS GENERATORS
452 CHAPTER 61 LIQUEFIED PETROLEUM GASES
SECTION 6101 GENERAL
SECTION 6102 DEFINITIONS
SECTION 6103 INSTALLATION OF EQUIPMENT
453 SECTION 6104 LOCATION OF LP-GAS CONTAINERS
SECTION 6105 PROHIBITED USE OF LP-GAS
SECTION 6106 DISPENSING AND OVERFILLING
454 TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS
SECTION 6107 SAFETY PRECAUTIONS AND DEVICES
SECTION 6108 FIRE PROTECTION
455 SECTION 6109 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
456 TABLE 6109.1 2SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS
SECTION 6110 LP-GAS CONTAINERS NOT IN SERVICE
SECTION 6111 PARKING AND GARAGING OF LP-GAS TANK VEHICLES
458 CHAPTER 62 ORGANIC PEROXIDES
SECTION 6201 GENERAL
SECTION 6202 DEFINITION
SECTION 6203 GENERAL REQUIREMENTS
SECTION 6204 STORAGE
459 TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES
460 SECTION 6205 USE
462 CHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION 6301 GENERAL
SECTION 6302 DEFINITIONS
SECTION 6303 GENERAL REQUIREMENTS
463 SECTION 6304 STORAGE
TABLE 6304.1.2 OXIDIZER LIQUIDS AND SOLIDS—DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
TABLE 6304.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERSa
464 TABLE 6304.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDSa, b
TABLE 6304.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDSa, b
TABLE 6304.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.2.2 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa
465 SECTION 6305 USE
SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE
468 CHAPTER 64 PYROPHORIC MATERIALS
SECTION 6401 GENERAL
SECTION 6402 DEFINITION
SECTION 6403 GENERAL REQUIREMENTS
SECTION 6404 STORAGE
469 TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6405 USE
470 CHAPTER 65 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 6501 GENERAL
SECTION 6502 DEFINITIONS
SECTION 6503 GENERAL REQUIREMENTS
SECTION 6504 STORAGE AND HANDLING
472 CHAPTER 66 UNSTABLE (REACTIVE) MATERIALS
SECTION 6601 GENERAL
SECTION 6602 DEFINITION
SECTION 6603 GENERAL REQUIREMENTS
SECTION 6604 STORAGE
473 SECTION 6605 USE
474 CHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 6701 GENERAL
SECTION 6702 DEFINITION
SECTION 6703 GENERAL REQUIREMENTS
SECTION 6704 STORAGE
475 SECTION 6705 USE
476 CHAPTERS 68 THROUGH 79 RESERVED
478 PART VI—REFERENCED STANDARDS
CHAPTER 80 REFERENCED STANDARDS
AASHTO
AFSI
API
479 ASME
ASTM
480 BHMA
CA
CGA
481 CGR
CPSC
DOC
DOL
DOTn
482 DOTy
EN
EPA
FCC
483 ICC
ISO
484 NEMA
NFPA
486 UL
487 USC
488 PART VII—APPENDICES
APPENDIX A BOARD OF APPEALS
SECTION A101 GENERAL
490 APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
SECTION B104 FIRE-FLOW CALCULATION AREA
SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS IN PROTECTED AREAS WITH ADEQUATE AND RELIABLE WATER SYSTEMS
491 TABLE B105.2 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS
492 TABLE B105.4
SECTION B106 LIMITING FIRE-FLOW REQUIREMENTS FOR BUILDINGS IN PROTECTED AREAS WITH ADEQUATE AND RELIABLE WATER SYSTEMS
SECTION B107 FIRE-FLOW REQUIREMENTS FOR BUILDINGS IN PROTECTED AREAS WITHOUT ADEQUATE AND RELIABLE WATER SYSTEMS
SECTION B108 FIRE-FLOW REQUIREMENTS FOR BUILDINGS IN UNPROTECTED AREAS (RESERVED)
SECTION B109 REFERENCED STANDARDS
494 APPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 LOCATION
SECTION C103 NUMBER OF FIRE HYDRANTS
SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION C105 DISTRIBUTION OF FIRE HYDRANTS
TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS
496 APPENDIX D FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
SECTION D103 MINIMUM SPECIFICATIONS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
497 TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
FIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS
498 SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
D108 REFERENCED STANDARDS
500 APPENDIX E HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES
504 SECTION E103 EVALUATION OF HAZARDS
505 E104 REFERENCED STANDARDS
506 APPENDIX F HAZARD RANKING
SECTION F101 GENERAL
SECTION F102 REFERENCED STANDARDS
507 TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES
508 APPENDIX G CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL
509 TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS
510 APPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS
SECTION H101 HMMP
SECTION H102 HMIS
511 SECTION H103 EMERGENCY PLAN
SECTION H104 REFERENCED STANDARDS
512 FIGURE 1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
513 FIGURE 2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
514 FIGURE 3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C—FACILITY MAP
515 FIGURE 4 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS SUMMARY REPORTa (Storageb Conditions)c
516 FIGURE 5 SECTION II — HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS INVENTORY REPORT (Sort Products Alphabetically by Location of Product and then Alphabetically by Product Name)
518 APPENDIX I FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS
519 SECTION I102 REFERENCED STANDARDS
520 APPENDIX J BUILDING INFORMATION SIGN
SECTION J101 GENERAL
FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN
522 SECTION J102 REFERENCED STANDARDS
524 APPENDIX K FIRE PREVENTION GUIDELINES FOR HAUNTED HOUSES AND SIMILAR TEMPORARY INSTALLATIONS
SECTION K101 GENERAL
SECTION K102 PERMITS
SECTION K103 GENERAL REQUIREMENTS
526 APPENDIX L ADULT FOSTER HOMES
SECTION L101 GENERAL
SECTION L102 DEFINITIONS
SECTION L103 CONSTRUCTION
SECTION L104 EXITS AND EMERGENCY EGRESS
527 SECTION L105 FLAME SPREAD AND SMOKE DENSITY
SECTION L106 SMOKE ALARMS
SECTION L107 PORTABLE FIRE EXTINGUISHERS
SECTION L108 HEATING EQUIPMENT
SECTION L109 ELECTRICAL EQUIPMENT AND WIRING
SECTION L110 EMERGENCY PROCEDURES
528 SECTION L111 SPECIAL HAZARDS
530 APPENDIX M TANK VEHICLE TO TANK VEHICLE FUEL TRANSFER AT AIRPORTS
SECTION M101 GENERAL
SECTION M102 DEFINITIONS
SECTION M103 SITE REQUIREMENTS
SECTION M104 PERSONNEL REQUIREMENTS
SECTION M105 VEHICLE AND EQUIPMENT REQUIREMENTS
532 APPENDIX N FIRE WATCH
SECTION N101 GENERAL
SECTION N102 DEFINITIONS
SECTION N103 REQUIREMENTS
SECTION N104 DOCUMENTATION
533 FIGURE N104.1A FIRE WATCH NOTICE
534 FIGURE N104.1B
536 INDEX
572 NEW TOOLS FOR YOUR FIRE CODE
OR PortlandFireCode 2016
$49.58