Shopping Cart

No products in the cart.

PA PhiladelphiaFireCode 2007

$59.04

The City of Philadelphia Fire Code

Published By Publication Date Number of Pages
PA 2007 447
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
1 WELCOME PAGE
THE CITY OF PHILADELPHIA FIRE CODE 2007
2 THE CITY OF PHILADELPHIA FIRE CODE 2007 TITLE PAGE
3 COPYRIGHT © 2007
4 HISTORY
6 NOTE TO USERS OF THE PHILADELPHIA FIRE CODE
8 TABLE OF CONTENTS
14 CHAPTER 1 ADMINISTRATION
SECTION F-101 GENERAL
SECTION F-102 APPLICABILITY
SECTION F-103 UNSAFE CONDITIONS
SECTION F-104 GENERAL AUTHORITY AND RESPONSIBILITIES
15 SECTION F-105 PERMITS
16 TABLE F-105.6.9 PERMIT AMOUNTS FOR COMPRESSED GASES1
TABLE F-105.6.11 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
17 TABLE F-105.6.21 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS2
20 SECTION F-106 MAINTENANCE
21 SECTION F-107 BOARD OF SAFETY AND FIRE PREVENTIO
22 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION F-202 GENERAL DEFINITIONS
36 CHAPTER 3 GENERAL PRECAUTIONS AGAINST FIRE
SECTION 301 GENERAL
SECTION F-302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
SECTION 304 COMBUSTIBLE WASTE MATERIAL
37 SECTION F-305 IGNITION SOURCES
SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM
SECTION F-307 OPEN BURNING5
38 SECTION F-308 OPEN FLAMES
40 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
SECTION 310 SMOKING
SECTION F-311 VACANT PREMISES
41 SECTION 312 VEHICLE IMPACT PROTECTION
42 SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS
SECTION F-315 MISCELLANEOUS COMBUSTIBLE MATERIALS STORAGE
44 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION F-401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS
SECTION F-404 FIRE SAFETY AND EVACUATION PLANS
46 SECTION F-405 EMERGENCY EVACUATION DRILLS
TABLE F-405.28 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
SECTION F-406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
47 SECTION 407 HAZARD COMMUNICATION
SECTION F-408 USE AND OCCUPANCY-RELATED REQUIREMENTS
50 SECTION F-409 SHELTERING IN PLACE
SECTION F-410 FAMILY CHILD DAY CARE FACILITIES
52 CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION F-503 FIRE APPARATUS ACCESS ROADS
53 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
SECTION 505 PREMISES IDENTIFICATION
54 SECTION 506 KEY BOXES
SECTION 507 HAZARDS TO FIRE FIGHTERS
SECTION F-508 FIRE PROTECTION WATER SUPPLIES
55 SECTION 509 FIRE COMMAND CENTER
56 SECTION 510 FIRE DEPARTMENT ACCESS TO EQUIPMENT
58 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
SECTION F-603 FUEL-FIRED APPLIANCES
60 SECTION F-604 EMERGENCY AND STANDBY POWER SYSTEMS
63 SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
64 SECTION 606 MECHANICAL REFRIGERATION
66 SECTION F-607 ELEVATOR RECALL AND MAINTENANCE
SECTION F-608 STATIONARY STORAGE BATTERY SYSTEMS
67 TABLE 608.1 BATTERY REQUIREMENTS
68 SECTION 609 COMMERCIAL KITCHEN HOODS
70 CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION F-704 FLOOR OPENINGS AND SHAFTS
71 TABLE F-704.114 VERTICAL OPENING PROTECTION REQUIRED
72 CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS
73 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
74 SECTION 804 INTERIOR WALL AND CEILING TRIM IN NEW AND EXISTING BUILDINGS
SECTION F-805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
76 SECTION F-806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
77 SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
78 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
80 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION F-901 GENERAL
81 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
85 SECTION 902 DEFINITIONS
87 SECTION F-903 AUTOMATIC SPRINKLER SYSTEMS
88 TABLE 903.2.4.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
90 TABLE 903.2.13 ADDITIONAL REQUIRED FIRE-EXTINGUISHING SYSTEMS
TABLE 903.2.13—continued ADDITIONAL REQUIRED FIRE-EXTINGUISHING SYSTEMS
93 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
95 SECTION F-905 STANDPIPE SYSTEMS
98 SECTION F-906 PORTABLE FIRE EXTINGUISHERS
99 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
100 TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCH
SECTION F-907 FIRE ALARM AND DETECTION SYSTEMS
109 TABLE 907.10.1.3 VISIBLE AND AUDIBLE ALARMS
111 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
113 EQUATION 9-1
EQUATION 9-2
EQUATION 9-3
117 SECTION 910 SMOKE AND HEAT VENTS
TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
118 EQUATION 9-4
SECTION 911 EXPLOSION CONTROL
119 TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS
120 SECTION F-912 FIRE DEPARTMENT CONNECTIONS
SECTION F-913 FIRE PUMPS
121 SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
123 SECTION F-915 PERIODIC TESTING OF FIRE PROTECTION SYSTEMS
126 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[B] SECTION 1002 DEFINITIONS
127 [B] SECTION 1003 GENERAL MEANS OF EGRESS
128 [B] SECTION F-1004 OCCUPANT LOAD
129 TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
130 [B] SECTION 1005 EGRESS WIDTH
TABLE 1005.1 EGRESS WIDTH PER OCCUPANT SERVED
[B] SECTION 1006 MEANS OF EGRESS ILLUMINATION
[B] SECTION 1007 ACCESSIBLE MEANS OF EGRESS
132 [B] SECTION F-1008 DOORS, GATES AND TURNSTILES
133 TABLE 1008.1.3.1 REVOLVING DOOR SPEEDS
137 [B] SECTION 1009 STAIRWAYS
140 [B] SECTION 1010 RAMPS
141 [B] SECTION 1011 EXIT SIGNS
142 [B] SECTION 1012 HANDRAILS
[B] SECTION 1013 GUARDS
143 [B] SECTION 1014 EXIT ACCESS
145 [B] SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
TABLE 1015.1 SPACES WITH ONE MEANS OF EGRESS
146 [B] SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
147 TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCEa
[B] SECTION 1017 CORRIDORS
TABLE 1017.1 CORRIDOR FIRE-RESISTANCE RATING
148 [B] SECTION 1018 EXITS
[B] SECTION 1019 NUMBER OF EXITS AND CONTINUITY
TABLE 1019.1 MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
149 TABLE 1019.2 BUILDINGS WITH ONE EXIT
[B] SECTION F-1020 VERTICAL EXIT ENCLOSURES
151 [B] SECTION 1021 EXIT PASSAGEWAYS
152 [B] SECTION 1022 HORIZONTAL EXITS
[B] SECTION 1023 EXTERIOR EXIT RAMPS AND STAIRWAYS
153 [B] SECTION 1024 EXIT DISCHARGE
154 [B] SECTION 1025 ASSEMBLY
155 TABLE 1025.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
157 TABLE 1025.10.1 SMOKE-PROTECTEDASSEMBLY AISLE ACCESSWAYS
158 [B] SECTION 1026 EMERGENCY ESCAPE AND RESCUE
159 SECTION F-1027 MEANS OF EGRESS FOR EXISTING BUILDINGS
161 TABLE 1027.9 REVOLVING DOOR SPEEDS
163 TABLE 1027.17.2 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
164 SECTION F-1028 MAINTENANCE OF THE MEANS OF EGRESS
166 CHAPTER 11 AVIATION FACILITIES
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 GENERAL PRECAUTIONS
SECTION 1104 AIRCRAFT MAINTENANCE
167 SECTION 1105 PORTABLE FIRE EXTINGUISHERS
SECTION 1106 AIRCRAFT FUELING
172 SECTION 1107 HELISTOPS AND HELIPORTS
174 CHAPTER 12 DRY CLEANING
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 CLASSIFICATIONS
SECTION 1204 GENERAL REQUIREMENTS
175 SECTION 1205 OPERATING REQUIREMENTS
EQUATION 12-1
SECTION 1206 SPOTTING AND PRETREATING
176 SECTION 1207 DRY CLEANING SYSTEMS
SECTION 1208 FIRE PROTECTION
178 CHAPTER 13 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 1301 GENERAL
SECTION 1302 DEFINITIONS
SECTION 1303 PRECAUTIONS
SECTION 1304 EXPLOSION PROTECTION
TABLE 1304.1 EXPLOSION PROTECTION STANDARDS
180 CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 TEMPORARY HEATING EQUIPMENT
SECTION 1404 PRECAUTIONS AGAINST FIRE
SECTION 1405 FLAMMABLE AND COMBUSTIBLE LIQUIDS
181 SECTION 1406 FLAMMABLE GASES
SECTION 1407 EXPLOSIVE MATERIALS
SECTION 1408 OWNER’S RESPONSIBILITY FOR FIREPROTECTION
SECTION 1409 FIRE REPORTING
SECTION 1410 ACCESS FOR FIRE FIGHTING
SECTION 1411 MEANS OF EGRESS
SECTION 1412 WATER SUPPLY FOR FIRE PROTECTION
182 SECTION 1413 STANDPIPES
SECTION F-1414 AUTOMATIC SPRINKLER SYSTEM
SECTION 1415 PORTABLE FIRE EXTINGUISHERS
SECTION 1416 MOTORIZED EQUIPMENT
SECTION 1417 SAFEGUARDING ROOFING OPERATIONS
SECTION F-1418 ASBESTOS ABATEMENT
184 CHAPTER 15 FLAMMABLE FINISHES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
185 SECTION 1503 PROTECTION OF OPERATIONS
186 SECTION 1504 SPRAY FINISHING
190 SECTION 1505 DIPPING OPERATIONS
191 SECTION 1506 POWDER COATING
192 SECTION 1507 ELECTROSTATIC APPARATUS
SECTION 1508 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
193 SECTION 1509 INDOOR MANUFACTURING OF REINFORCED PLASTICS
SECTION 1510 FLOOR SURFACING AND FINISHING OPERATIONS
196 CHAPTER 16 FRUIT AND CROP RIPENING
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS
SECTION 1603 ETHYLENE GAS
SECTION 1604 SOURCES OF IGNITION
SECTION 1605 COMBUSTIBLE WASTE
SECTION 1606 ETHYLENE GENERATORS
SECTION 1607 WARNING SIGNS
198 CHAPTER 17 FUMIGATION AND THERMAL INSECTICIDAL FOGGING
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 FIRE SAFETY REQUIREMENTS
200 CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GENERAL SAFETY PROVISIONS
204 SECTION 1804 STORAGE
205 TABLE 1804.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
206 TABLE 1804.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
SECTION 1805 USE AND HANDLING
207 TABLE 1805.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONe
210 CHAPTER 19 LUMBER YARDS AND WOODWORKING FACILITIES
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 GENERAL REQUIREMENTS
SECTION 1904 FIRE PROTECTION
211 SECTION 1905 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 1906 LOG STORAGE AREAS
SECTION 1907 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 1908 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES
212 SECTION 1909 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS
214 CHAPTER 20 MANUFACTURE OF ORGANIC COATINGS
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 ELECTRICAL EQUIPMENT AND PROTECTION
215 SECTION 2005 PROCESS STRUCTURES
SECTION 2006 PROCESS MILLS AND KETTLES
SECTION 2007 PROCESS PIPING
216 SECTION 2008 RAW MATERIALS IN PROCESS AREAS
SECTION 2009 RAW MATERIALS AND FINISHED PRODUCTS
218 CHAPTER 21 INDUSTRIAL OVENS
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 LOCATION
SECTION 2104 FUEL PIPING
SECTION 2105 INTERLOCKS
219 SECTION 2106 FIRE PROTECTION
SECTION 2107 OPERATION AND MAINTENANCE
220 CHAPTER 22 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 LOCATION OF DISPENSING DEVICES
221 SECTION 2204 DISPENSING OPERATIONS
222 SECTION 2205 OPERATIONAL REQUIREMENTS
SECTION F-2206 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
223 TABLE 2206.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
226 SECTION 2207 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
227 SECTION F-2208 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
229 TABLE 2208.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 2209 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
230 TABLE 2209.3.1 MINIMUM SEPARATION FOR GASEOUS HYDROGEN DISPENSERS, COMPRESSORS, GENERATORS AND STORAGE VESSELS
232 FIGURE 2209.5.4.3.4 HYDROGEN VENT PIPE HEIGHT (H) VERSUS DISTANCE (D) REQUIREMENTS
SECTION 2210 MARINE MOTOR FUEL-DISPENSING FACILITIES
233 TABLE 2209.5.4.3.4 VENT PIPE HEIGHT AND SEPARATION DISTANCE VERSUS HYDROGEN FLOW RATE AND VENT PIPE DIAMETER a,b,c,d,e,f
TABLE 2209.5.4.3.6(1) MAXIMUM RADIANT HEAT EXPOSURE
TABLE 2209.5.4.3.6(2) MAXIMUM HYDROGEN CONCENTRATION EXPOSURE
234 SECTION 2211 REPAIR GARAGES
238 CHAPTER 23 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
239 SECTION 2303 COMMODITY CLASSIFICATION
241 SECTION 2304 DESIGNATION OF HIGH-PILED STORAGE AREAS
SECTION 2305 HOUSEKEEPING AND MAINTENANCE
SECTION 2306 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
242 FIGURE 2303.7.4 MIXED COMMODITIESa, b
243 TABLE 2306.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
245 SECTION 2307 SOLID-PILED AND SHELF STORAGE
SECTION 2308 RACK STORAGE
SECTION 2309 AUTOMATED STORAGE
246 TABLE 2308.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 2310 SPECIALTY STORAGE
248 CHAPTER 24 TENTS, CANOPIES AND OTHER MEMBRANE STRUCTURES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 TEMPORARY TENTS, CANOPIES AND MEMBRANE STRUCTURES
249 TABLE 2403.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES, TENTS AND CANOPIES
250 SECTION F-2404 TEMPORARY AND PERMANENT TENTS, CANOPIES AND MEMBRANE STRUCTURES
254 CHAPTER 25 TIRE REBUILDING AND TIRE STORAGE
SECTION F-2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 TIRE REBUILDING
SECTION 2504 PRECAUTIONS AGAINST FIRE
SECTION 2505 OUTDOOR STORAGE
255 SECTION 2506 FIRE DEPARTMENT ACCESS
SECTION 2507 FENCING
SECTION 2508 FIRE PROTECTION
SECTION 2509 INDOOR STORAGE ARRANGEMENT
SECTION F-2510 VEHICLE SALVAGE AND WRECKING FACILITIES
256 CHAPTER 26 WELDING AND OTHER HOT WORK
SECTION F-2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 GENERAL REQUIREMENTS
257 SECTION 2604 FIRE SAFETY REQUIREMENTS
258 SECTION 2605 GAS WELDING AND CUTTING
SECTION 2606 ELECTRIC ARC HOT WORK
SECTION 2607 CALCIUM CARBIDE SYSTEMS
SECTION 2608 ACETYLENE GENERATORS
259 SECTION 2609 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
260 CHAPTER 27 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION F-2701 GENERAL
265 SECTION F-2702 DEFINITIONS
268 SECTION F-2703 GENERAL REQUIREMENTS
269 TABLE 2703.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
270 TABLE 2703.1.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
271 TABLE 2703.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARDa,b,c,j
272 TABLE 2703.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREAa, b, c
273 TABLE 2703.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREAa,b,c
277 TABLE 2703.8.2 REQUIRED DETACHED STORAGE
TABLE 2703.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
280 TABLE 2703.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS d, e, f
281 SECTION 2704 STORAGE
282 TABLE 2704.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
284 SECTION 2705 USE, DISPENSING AND HANDLING
286 TABLE 2705.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
290 CHAPTER 28 AEROSOLS
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 2803.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 2804 INSIDE STORAGE OF AEROSOL PRODUCTS
291 TABLE 2804.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb
TABLE 2804.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 2804.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
292 TABLE 2804.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 2805 OUTSIDE STORAGE
TABLE 2805.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
293 SECTION 2806 RETAIL DISPLAY
TABLE 2806.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
294 TABLE 2806.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
SECTION 2807 MANUFACTURING FACILITIES
296 CHAPTER 29 COMBUSTIBLE FIBERS
SECTION 2901 GENERAL
SECTION 2902 DEFINITIONS
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 LOOSE FIBER STORAGE
297 SECTION 2905 BALED STORAGE
298 CHAPTER 30 COMPRESSED GASES
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
SECTION 3003 GENERAL REQUIREMENTS
302 SECTION 3004 STORAGE OF COMPRESSED GASES
SECTION 3005 USE AND HANDLING OF COMPRESSED GASES
SECTION 3006 MEDICAL GAS SYSTEMS
303 SECTION 3007 COMPRESSED GASES NOT OTHERWISE REGULATED
304 CHAPTER 31 CORROSIVE MATERIALS
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 GENERAL REQUIREMENTS
SECTION 3104 STORAGE
SECTION 3105 USE
306 CHAPTER 32 CRYOGENIC FLUIDS
SECTION 3201 GENERAL
SECTION 3202 DEFINITIONS
SECTION 3203 GENERAL REQUIREMENTS
308 TABLE 3203.6.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
TABLE 3203.6.2 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 3204 STORAGE
310 SECTION 3205 USE AND HANDLING
312 CHAPTER 33 EXPLOSIVES AND FIREWORKS
SECTION F-3301 GENERAL
314 TABLE 3301.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVESa,b,c
TABLE 3301.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVESa,b,c
TABLE 3301.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVESa,b,c
316 SECTION F-3302 DEFINITIONS
319 SECTION 3303 RECORD KEEPING AND REPORTING
SECTION 3304 EXPLOSIVE MATERIALS STORAGE AND HANDLING
320 TABLE 3304.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
322 TABLE 3304.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
323 TABLE 3304.5.2(1)–continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
324 TABLE 3304.5.2(1)–continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
TABLE 3304.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS CONTAINING EXPLOSIVES — DIVISION 1.3 MASS-FIRE HAZARDa, b, c
325 TABLE 3304.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS CONTAINING EXPLOSIVES —DIVISION 1.4 c
SECTION F-3305 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS
327 TABLE 3305.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES — DIVISION 1.1, 1.2 OR 1.5 — MASS EXPLOSION HAZARDa
328 SECTION 3306 SMALL ARMS AMMUNITION
330 SECTION 3307 BLASTING
SECTION F-3308 FIREWORKS DISPLAY
332 CHAPTER 34 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
333 SECTION F-3403 GENERAL REQUIREMENTS
334 TABLE 3403.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
335 TABLE 3403.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
337 SECTION F-3404 STORAGE
348 TABLE 3404.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa
350 TABLE 3404.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
TABLE 3404.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
351 TABLE 3404.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
352 TABLE 3404.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN CONTAINERS AND PORTABLE TANKSa
353 TABLE 3404.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
354 TABLE 3404.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN CONTAINERS GREATER THAN 5-GALLON CAPACITYa
355 TABLE 3404.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN CONTAINERS GREATER THAN 5-GALLON CAPACITYa,b
TABLE 3404.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa
356 TABLE 3404.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESSa,b
357 TABLE 3404.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
SECTION F-3405 DISPENSING, USE, MIXING AND HANDLING
358 TABLE 3405.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
359 TABLE 3405.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 3405.3.4(1)
361 TABLE 3405.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREASa,b
362 SECTION F-3406 SPECIAL OPERATIONS
372 CHAPTER 35 FLAMMABLE GASES
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
373 SECTION 3504 STORAGE
TABLE 3504.2.1 FLAMMABLE GASES— DISTANCE FROM STORAGE TO EXPOSURES
SECTION 3505 USE
374 CHAPTER 36 FLAMMABLE SOLIDS
SECTION 3601 GENERAL
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL REQUIREMENTS
SECTION 3604 STORAGE
SECTION 3605 USE
SECTION 3606 MAGNESIUM
378 CHAPTER 37 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 3701 GENERAL
SECTION 3702 DEFINITIONS
379 SECTION 3703 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
380 SECTION 3704 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
382 TABLE 3704.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
384 SECTION 3705 OZONE GAS GENERATORS
386 CHAPTER 38 LIQUEFIED PETROLEUM GASES
SECTION F-3801 GENERAL
SECTION 3802 DEFINITIONS
SECTION F-3803 INSTALLATION OF EQUIPMENT
387 SECTION F-3804 LOCATION OF CONTAINERS
TABLE 3804.3 LOCATION OF LP-GAS CONTAINERS
388 SECTION 3805 PROHIBITED USE OF LP-GAS
SECTION 3806 DISPENSING AND OVERFILLING
SECTION 3807 SAFETY PRECAUTIONS AND DEVICES
SECTION 3808 FIRE PROTECTION
SECTION 3809 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
389 TABLE 3809.12 SEPARATION FROM EXPOSURES OF CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS FROM EXPOSURES
390 SECTION 3810 CONTAINERS NOT IN SERVICE
SECTION 3811 PARKING AND GARAGING
392 CHAPTER 39 ORGANIC PEROXIDES
SECTION 3901 GENERAL
SECTION 3902 DEFINITIONS
SECTION 3903 GENERAL REQUIREMENTS
SECTION 3904 STORAGE
393 TABLE 3904.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
394 TABLE 3904.1.7 STORAGE OF ORGANIC PEROXIDES
SECTION 3905 USE
396 CHAPTER 40 OXIDIZERS
SECTION 4001 GENERAL
SECTION 4002 DEFINITIONS
SECTION 4003 GENERAL REQUIREMENTS
397 SECTION 4004 STORAGE
TABLE 4004.1.2 OXIDIZER LIQUIDS AND SOLIDS—DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
398 TABLE 4004.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERSa
TABLE 4004.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDSa,b
TABLE 4004.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDSa,b
TABLE 4004.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
SECTION 4005 USE
399 TABLE 4004.2.2 OXIDIZER GASES — DISTANCES FROM STORAGE TO EXPOSURESa
400 CHAPTER 41 PYROPHORIC MATERIALS
SECTION 4101 GENERAL
SECTION 4102 DEFINITIONS
SECTION 4103 GENERAL REQUIREMENTS
SECTION 4104 STORAGE
401 TABLE 4104.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 4105 USE
SECTION 4106 SILANE GAS
404 CHAPTER 42 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 4201 GENERAL
SECTION 4202 DEFINITIONS
SECTION 4203 GENERAL REQUIREMENTS
SECTION 4204 STORAGE AND HANDLING
406 CHAPTER 43 UNSTABLE (REACTIVE) MATERIALS
SECTION 4301 GENERAL
SECTION 4302 DEFINITIONS
SECTION 4303 GENERAL REQUIREMENTS
407 SECTION 4304 STORAGE
SECTION 4305 USE
408 CHAPTER 44 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 4401 GENERAL
SECTION 4402 DEFINITIONS
SECTION 4403 GENERAL REQUIREMENTS
SECTION 4404 STORAGE
409 SECTION 4405 USE
410 CHAPTER 45 REFERENCED STANDARDS
AASHTO
AFSI
API
ASME
411 ASTM
BHMA
CA
412 CGA
CGR
CPSC
DOC
413 DOL
DOTn
DOTy
ICC
414 ISO
NEMA
NFPA
416 UL
417 USC
418 APPENDIX A-G NOT ADOPTED
420 APPENDIX H
ELEVATOR CALL STATION PICTOGRAPH
HIGH-RISE BUILDING ELEVATOR CALL STATION FLOOR DIAGRAM
422 INDEX
446 ENDNOTES
PA PhiladelphiaFireCode 2007
$59.04