PA PhiladelphiaPlumbingCode 2018
$53.35
Philadelphia Plumbing Code
Published By | Publication Date | Number of Pages |
PA | 2018 | 304 |
This is a fully integrated code based on the 2018 International Plumbing Code
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2018 PHILADELPHIA PLUMBING CODE |
2 | COPYRIGHT |
3 | PREFACE |
5 | EFFECTIVE USE OF THE PHILADELPHIA PLUMBING CODE |
9 | TABLE OF CONTENTS |
13 | CHAPTER 1 SCOPE AND ADMINISTRATION SECTION P-101 GENERAL SECTION P-102 INSPECTIONS AND TESTING |
14 | SECTION P-103 PERMITS AND LICENSES |
15 | SECTION P-104 TEMPORARY EQUIPMENT, SYSTEMS AND USES SECTION P-105 REGULATIONS SECTION P-106 PLUMBING ADVISORY BOARD |
17 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
25 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS SECTION 304 RODENTPROOFING |
26 | SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS SECTION 306 TRENCHING, EXCAVATION AND BACKFILL |
27 | SECTION 307 STRUCTURAL SAFETY SECTION 308 PIPING SUPPORT TABLE P-308.5 HANGER SPACING |
28 | TABLE P-308.5—continued HANGER SPACING SECTION 309 FLOOD HAZARD RESISTANCE SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS SECTION 311 TOILET FACILITIES FOR WORKERS |
29 | TABLE P-311.1 MINIMUM NUMBER OF TOILET FACILITIES SECTION 312 TESTS AND INSPECTIONS |
30 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL |
31 | [M] TABLE 314.2.2 CONDENSATE DRAIN SIZING SECTION 315 PENETRATIONS SECTION 316 ALTERNATIVE ENGINEERED DESIGN |
33 | CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
34 | TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
35 | TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
37 | SECTION 404 ACCESSIBLE PLUMBING FACILITIES SECTION 405 INSTALLATION OF FIXTURES |
38 | SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 407 BATHTUBS SECTION 408 BIDETS SECTION 409 DISHWASHING MACHINES |
39 | SECTION 410 DRINKING FOUNTAINS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 412 FAUCETS AND FIXTURE FITTINGS |
40 | SECTION 413 FLOOR AND TRENCH DRAINS SECTION 414 FLOOR SINKS SECTION 415 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
41 | SECTION 416 FOOD WASTE DISPOSER UNITS SECTION 417 GARBAGE CAN WASHERS SECTION 418 LAUNDRY TRAYS SECTION 419 LAVATORIES SECTION 420 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 421 SHOWERS |
42 | SECTION 422 SINKS SECTION 423 SPECIALTY PLUMBING FIXTURES |
43 | SECTION 424 URINALS SECTION 425 WATER CLOSETS SECTION 426 WHIRLPOOL BATHTUBS |
45 | CHAPTER 5 WATER HEATERS SECTION 501 GENERAL SECTION 502 INSTALLATION |
46 | SECTION 503 CONNECTIONS SECTION 504 SAFETY DEVICES |
47 | SECTION 505 INSULATION |
49 | CHAPTER 6 WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL SECTION 602 WATER REQUIRED SECTION 603 WATER SERVICE |
50 | SECTION P-604 DESIGN OF BUILDING WATER SUPPLY SYSTEM TABLE P-604.3 WATER SUPPLY SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS |
51 | TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
52 | TABLE P-605.3 WATER DISTRIBUTION PIPE |
53 | TABLE P-605.4 WATER SUPPLY PIPE TABLE 605.8 MANUFACTURED PIPE NIPPLES |
54 | TABLE 605.5 PIPE FITTINGS TABLE 605.7 VALVES |
57 | SECTION P-606 INSTALLATION OF THE BUILDING WATER SUPPLY SYSTEM |
58 | TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS SECTION 607 HOT WATER SUPPLY SYSTEM |
59 | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
60 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
61 | FIGURE 608.9.1 PICTOGRAPH—DO NOT DRINK TABLE 608.9.2.2 SIZE OF PIPE IDENTIFICATION |
63 | TABLE 608.16.1 MINIMUM REQUIRED AIR GAPS |
64 | TABLE 608.18.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES |
65 | SECTION 609 HEALTH CARE PLUMBING SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 612 SOLAR SYSTEMS |
66 | SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES SECTION P-614 PRIVATE WATER INFRASTRUCTURE SECTION P-615 ABANDONED WATER SUPPLY SYSTEM AND COMPONENTS |
67 | CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL SECTION 702 MATERIALS TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
68 | TABLE P-702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE P-702.3 BUILDING SEWER PIPE |
69 | TABLE 702.4 PIPE FITTINGS SECTION 703 BUILDING SEWER SECTION 704 DRAINAGE PIPING INSTALLATION |
70 | TABLE P-704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE SECTION 705 JOINTS |
72 | TABLE 705.18 CAULKING FERRULE SPECIFICATIONS TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS |
73 | SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS |
74 | SECTION 709 FIXTURE UNITS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS |
75 | TABLE P-709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
76 | SECTION 710 DRAINAGE SYSTEM SIZING TABLE P-710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE |
77 | SECTION 712 SUMPS AND EJECTORS |
78 | TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION 713 COMPUTERIZED DRAINAGE DESIGN SECTION 714 BACKWATER VALVES SECTION 715 VACUUM DRAINAGE SYSTEMS SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS |
79 | SECTION P-717 PRIVATE SANITARY SEWER INFRASTRUCTURE |
81 | CHAPTER 8 INDIRECT/SPECIAL WASTE SECTION 801 GENERAL SECTION 802 INDIRECT WASTES |
82 | SECTION 803 SPECIAL WASTES |
83 | CHAPTER 9 VENTS SECTION 901 GENERAL SECTION 902 MATERIALS SECTION 903 VENT TERMINALS SECTION 904 OUTDOOR VENT EXTENSIONS |
84 | SECTION 905 VENT CONNECTIONS AND GRADES SECTION 906 VENT PIPE SIZING SECTION 907 VENTS FOR STACK OFFSETS |
85 | TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
86 | TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS SECTION 909 FIXTURE VENTS TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION 910 INDIVIDUAL VENT SECTION 911 COMMON VENT |
87 | TABLE 911.3 COMMON VENT SIZES SECTION 912 WET VENTING TABLE 912.3 WET VENT SIZE SECTION 913 WASTE STACK VENT TABLE 913.4 WASTE STACK VENT SIZE |
88 | SECTION 914 CIRCUIT VENTING SECTION 915 COMBINATION WASTE AND VENT SYSTEM TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE SECTION 916 ISLAND FIXTURE VENTING |
89 | SECTION 917 SINGLE-STACK VENT SYSTEM TABLE 917.2 SINGLE STACK SIZE |
90 | SECTION 918 AIR ADMITTANCE VALVES SECTION P-919 PHILADELPHIA SINGLE-STACK WASTE AND VENT SYSTEM |
91 | TABLE P-919.2(a) FIXTURE-UNIT VALUES |
92 | TABLE P-919.2(b) OTHER FIXTURE VALUES TABLE P-919.2(c) MINIMUM PIPE SIZES ACCORDING TO FIXTURE LOAD (Maximum Fixture Units that may be Connected) |
94 | TABLE P-919.9(a) SIZE AND LENGTH OF VENTS SECTION 920 RESERVED |
95 | CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS |
96 | SECTION 1003 INTERCEPTORS AND SEPARATORS |
97 | TABLE 1003.3.5.1 CAPACITY OF GREASE INTERCEPTORSa |
98 | SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS |
99 | CHAPTER 11 STORM DRAINAGE SECTION 1101 GENERAL SECTION 1102 MATERIALS |
100 | TABLE P-1102.4 BUILDING STORM SEWER PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE TABLE 1102.7 PIPE FITTINGS SECTION 1103 TRAPS |
101 | SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS TABLE 1106.2 STORM DRAIN PIPE SIZING TABLE 1106.3 VERTICAL LEADER SIZING |
102 | TABLE 1106.6 HORIZONTAL GUTTER SIZING SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS |
103 | SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER TABLE P-1109.4 SIZE OF HORIZONTAL STORM DRAINAGE PIPING |
104 | SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1111 SUBSOIL DRAINS SECTION 1112 BUILDING SUBDRAINS SECTION 1113 SUMPS AND PUMPING SYSTEMS SECTION P-1114 SUSTAINABLE GREEN ROOF DRAINAGE SYSTEMS SECTION P-1115 PRIVATE STORM SEWER INFRASTRUCTURE |
107 | CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES SECTION 1203 OXYGEN SYSTEMS |
109 | CHAPTER 13 NONPOTABLE WATER SYSTEMS SECTION 1301 GENERAL FIGURE 1301.3 PICTOGRAPH—DO NOT DRINK |
111 | SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS |
112 | TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS |
113 | SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS |
114 | TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS |
115 | SECTION 1304 RECLAIMED WATER SYSTEMS |
117 | CHAPTER 14 RESERVED |
119 | CHAPTER 15 REFERENCED STANDARDS ANSI ASHRAE ASME |
121 | ASPE ASSE |
123 | ASTM |
128 | AWS AWWA |
129 | CISPI CSA |
132 | IAPMO ICC ISEA MSS |
133 | NFPA NGWA NSF |
134 | PDI PSAI UL |
135 | APPENDICES A–D RESERVED |
137 | APPENDIX E SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL SECTION E102 INFORMATION REQUIRED SECTION E103 SELECTION OF PIPE SIZE |
141 | TABLE E.1 TABLE E.2 |
142 | FIGURE E103.3(1) EXAMPLE-SIZING |
143 | TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS |
144 | TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa |
145 | TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND |
146 | TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH |
147 | TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBE |
148 | FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING) |
149 | FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING) |
150 | FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING) |
151 | FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa |
152 | FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa |
153 | FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa |
154 | SECTION E201 SELECTION OF PIPE SIZE SECTION E202 DETERMINATION OF PIPE VOLUMES |
155 | TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES |
156 | TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES |
157 | TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING |
159 | APPENDIX F FIGURES FIGURE 202(4) AIR GAP, AIR BREAK FIGURE 202(5) DEFINITION OF BRANCH INTERVAL |
160 | FIGURE 202(6) BRANCH INTERVALS |
161 | FIGURE 202(7) BRANCH VENT FIGURE 202(8) DRAINAGE SYSTEM COMPONENTS |
162 | FIGURE 202(9) DEPTH OF TRAP SEAL FIGURE 202(16) PARTS OF A PLUMBING SYSTEM |
163 | FIGURE 305.2(4) “U” BEND FIGURE 305.2(3) “Z” BEND FIGURE 305.3(1) PIPE PROTECTION |
164 | FIGURE 305.4(4) TYPICAL FREEZEPROOF HOSE FAUCET INSTALLATION FIGURE 306.2 PIPE ON BOTTOM OF TRENCH |
165 | FIGURE 306.2.1 OVEREXCAVATED TRENCH FIGURE 306.3 TAMPING LOOSE FILL IN 6-INCH LAYERS FIGURE 307.2(10) REQUIRED TOP PLATE REINFORCEMENT |
166 | FIGURE 307.3(1) THROUGH PENETRATION OF ASSEMBLIES FIGURE 307.3(2) MEMBRANE PENETRATION OF ASSEMBLY |
167 | FIGURE 307.5 EXCAVATION IN RELATION TO FOOTING FIGURE 308.5(1) POINT OF MAXIMUM SAGE BETWEEN SUPPORTS FIGURE 308.5(2) LOCATION OF HANGERS |
168 | FIGURE 308.6 SWAY BRACING FIGURE 308.7 RESTRAINED COUPLING FIGURE 308.7.1 ANCHORAGE LOCATION |
169 | FIGURE 312.9 TESTING OF FIELD-FABRICATED SHOWER LINER FIGURE 405.4(1) WATER CLOSET FLOOR FLANGE FIGURE 405.4(2) GASKETED WASTE TUBE CONNECTION FOR WATER CLOSET |
170 | FIGURE 405.4.3 WALL-HUNG WATER CLOSET FIGURE 405.6(1) JOINTS BETWEEN FIXTURES AND WALLS OR FLOORS FIGURE 409.4 RESIDENTIAL DISHWASHER WASTE CONNECTIONS |
171 | FIGURE 412.4 DELIVERED WATER TEMPERATURE LIMITS AND TEMPERATURE CONTROL OR DEVICE FIGURE 416.3 COMMERCIAL FOOD WASTE DISPOSER |
172 | FIGURE P-418.1 LAUNDRY TRAY FIGURE 419.1 LAVATORY FIGURE P-422.1(1) COMBINATION SINK AND TRAY FIGURE P-422.1(2) DOUBLE BOWL SINK FIGURE P-422.1(3) KITCHEN SINK FIGURE P-422.1(4) KITCHEN SINK |
173 | FIGURE 425.4 ACCEPTABLE 4 × 3 CLOSET BENDS FIGURE 504.4.1 TEMPERATURE- AND PRESSURE-RELIEF FIGURE 504.6(1) RELIEF VALVE DISCHARGE FIGURE 504.6(3) RELIEF VALVE DISCHARGE DRAINAGE PIPING SYSTEM |
174 | FIGURE 603.1(1) WATER SERVICE SYSTEM, PUBLIC WATER MAIN FIGURE 603.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER |
175 | FIGURE 603.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER FIGURE 604.1(2) WATER SYSTEM SCHEMATIC, THREE-STORY COMPACT BUILDING |
176 | FIGURE 604.1(4) WATER SYSTEM SCHEMATIC, SINGLE-STORY, 16-UNIT MOTEL FIGURE 604.1(8) WATER SYSTEM SCHEMATIC, EIGHT-STORY, 96-UNIT APARTMENT BUILDING |
177 | FIGURE 604.5 WATER SUPPLY CONNECTION WITH REDUCED-SIZE FLEXIBLE SUPPLY FIGURE 604.9(1) EXAMPLE OF MECHANICAL WATER-HAMMER ARRESTORS FIGURE 605.3(1) TYPICAL WATER DISTRIBUTION PIPE ENTRY INTO BUILDING |
178 | FIGURE 605.3(2) WATER SERVICE EXTENDING INTO BUILDING FIGURE 605.12.1 HEAT APPLICATION OF BRAZED JOINT FIGURE 605.12.3 PREPARATION OF PIPE END |
179 | FIGURE 605.13.2(1) TYPICAL FLARED TUBE JOINT FIGURE 605.13.2(2) TYPICAL FLARED TUBE JOINT FIGURE 605.18.4 BENDING PE PLASTIC PIPE FIGURE 605.23.1(2) DIELECTRIC UNION FIGURE 605.23.1(3) DIELECTRIC FLANGE FITTING |
180 | FIGURE 606.1(1) CURB VALVE ON WATER SERVICE FIGURE 606.1(2) VALVE AT ENTRANCE TO BUILDING AND ON DISCHARGE SIDE OF METER FIGURE 606.1(3) VALVES FOR EACH RISER AND DOWNFEED |
181 | FIGURE 606.1(4) DWELLING UNIT VALVES FIGURE 606.1(5) VALVES ON SUPPLY TO EACH TANK FIGURE 606.1(6) WATER HEATER VALVE |
182 | FIGURE 606.2(1) SHUTOFF VALVE FOR EACH FIXTIRE FIGURE 606.2(2) SILL FAUCET VALVE FIGURE 607.2 TEMPERATURE MAINTENANCE SYSTEM FOR HOT WATER USING PUMPED CIRCULATION LOOP |
183 | FIGURE 607.2.2(1) PROPER ARRANGEMENT FOR TEMPERED WATER RECIRCULATION RETURN FIGURE 607.3 THERMAL EXPANSION CONTROL USING THERMAL FIGURE 608.1(3) PRESSURE EXERTED BY A COLUMN OF WATER |
184 | FIGURE 608.1(4) BASE PRESSURE FIGURE 608.1(5) COLUMN OF WATER EXPOSED TO ATMOSPHERE FIGURE 608.1(6) OPEN TUBE INSERTED IN CONTAINER OF WATER FIGURE 608.1(7) VACUUM APPLIED TO A SEALED TUBE INSERTED IN A CONTAINER OF WATER |
185 | FIGURE 608.1(8) EXAMPLE OF SIMPLE SIPHON FIGURE 608.1(9) EXAMPLE OF ASPIRATION, OR VENTURI PRINCIPLE FIGURE 608.1(10) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE |
186 | FIGURE 608.7.1 CONNECTION BETWEEN TWO SYSTEMS FIGURE 608.14.4 BAROMETRIC LOOP FIGURE 608.14.5 PRESSURE VACUUM BREAKER FIGURE 608.14.7 DOUBLE CHECK-VALVE ASSEMBLY |
187 | FIGURE 608.17.1.1 BEVERAGE DISPONSER FIGURE 608.17.2 FOR BOILER WITHOUT CONDITIONING CHEMICALS FIGURE 609.2 DUAL WATER SERVICE FOR HOSPITALS |
188 | FIGURE 704.3 ZONE FOR POTENTIAL HYDRAULIC JUMP FIGURE 705.3.1 CAULKED JOINT FOR HUB AND SPIGOT (CAST-IRON) FIGURE 705.3.2 CAST-IRON COMPRESSION GASKET JOINT FIGURE 705.3.3 HUBLESS CAST-IRON DRAINAGE PIPE JOINT FIGURE 705.4 CONCRETE PIPE AND FITTING JOINT |
189 | FIGURE 705.5.1 HEAT APPLICATION FOR BRAZING JOINT FIGURE 705.5.3 PREPARATION OF PIPE END FIGURE 705.16.3 CAST-IRON ADAPTER FITTING FIGURE 705.17(1) SLIP JOINT, FLAT-RING STYLE |
190 | FIGURE 705.17(2) SLIP JOINTS, V-SHAPE O-RING STYLE FIGURE 705.17(3) TYPICAL LOCATIONS FOR SLIP JOINTS FIGURE 706.3(1) COMPARISON OF DIFFERENT SWEEP PATTERNS FOR VARIOUS MATERIALS FIGURE 706.3(2) COMPARISON OF COMBINATION WYE AND EIGHTH-BEND PATTERNS FOR VARIOUS MATERIALS |
191 | FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS FIGURE 706.3(4) DIFFERENCE BETWEEN PVC AND ABS PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT |
192 | FIGURE 706.3(5) COMBINATION TEES FIGURE 706.3(6) FITTING USES |
193 | FIGURE 706.3(7) IMPROPER USE OF DWV-PVC/ABS 90-DEGREE FITTINGS FIGURE 706.3(8) PROPER USE OF DWV-PVC/ABS 90-DEGREE FITTINGS FIGURE 706.3(9) BACK-TO-BACK WATER CLOSETS CONNECTED TO DOUBLE SANITARY TEE FIGURE 706.3(10) WATER CLOSET FIXTURE DRAINS CONNECTED TO WYE OR COMBINATION FITTING FIGURE 706.4(1) HEEL- AND SIDE-INLET QUARTER BEND APPLICATION RESTRICTIONS |
194 | FIGURE 706.4(3) HEEL INLET FITTINGS FIGURE 708.1.3 CLEANOUTS AT BUILDING DRAIN TO BUILDING SEWER JUNCTION |
195 | FIGURE 708.1.4 CLEANOUTS FIGURE 708.1.5(1) ACCEPTABLE CLEANOUTS |
196 | FIGURE 708.1.8 TWO-WAY CLEANOUT FITTING FIGURE 708.1.9 CLEARANCE FOR CLEANOUTS FIGURE 708.1.10 CLEANOUT INSTALLATIONS FIGURE 708.1.10.1 CLEANOUTS ON CONCEALED PIPING |
197 | FIGURE 710.1(1) BUILDING DRAIN SIZING FIGURE 710.1(2) HORIZONTAL BRANCH SIZING |
198 | FIGURE 710.1(4) STACK SIZING FIGURE 710.1(5) STACK SIZING GREATER THAN THREE BRANCH INTERVALS FIGURE 710.1(6) SIZING OF STACK THREE BRANCH INTERVALS OR LESS |
199 | FIGURE 710.1(7) FLOW IN A STACK FIGURE 710.1(8) REDUCING SIZE OF DRAINAGE STACK FIGURE 711.1(1) VERTICAL STACK OFFSET WITHOUT BRANCH CONNECTIONS WITHIN 2 FEET ABOVE OR BELOW OFFSET FIGURE 711.1(2) VERTICAL STACK OFFSET WITH BRANCH CONNECTIONS WITHIN 2 FEET ABOVE OR BELOW OFFSET |
200 | FIGURE 711.2(1) HORIZONTAL STACK OFFSET WITH VENTING FIGURE 711.2(2) HORIZONTAL STACK OFFSET WITH VENTING EXAMPLE |
201 | FIGURE 711.2.1 HORIZONTAL STACK OFFSET—VENTING NOT REQUIRED FIGURE 711.3(1) VERTICAL OFFSET SIZING WHERE THERE ARE NO STACK CONNECTIONS BELOW OFFSET FIGURE 711.3(2) HORIZONTAL OFFSET SIZING WHERE THERE ARE NO STACK CONNECTIONS BELOW OFFSET |
202 | FIGURE 712.1(1) PNEUMATIC SEWAGE EJECTOR FIGURE 712.1(2) VERTICAL SUSPENDED WET PIT SEWAGE PUMP FIGURE 712.2 SEWAGE PUMP INSTALLATION |
203 | FIGURE 712.4.1(2) MACERATING TOILET SYSTEM GRINDER/PUMP FIGURE 714.1 BACKWATER VALVE INSTALLATION |
204 | FIGURE P-714.1 BACKWATER VALVE FIGURE 714.2 COMMON TYPES OF BACKWATER VALVES |
205 | FIGURE 802.1.1(1) INDIRECTLY CONNECTED THREE-COMPARTMENT FOOD PREPARATION SINK FIGURE 802.1.1(2) REFRIGERATED FOOD CASE DRAINS INDIRECTLY CONNECTING TO HUB DRAIN |
206 | FIGURE 802.1.1(3) COMMERCIAL KITCHEN INDIRECT WASTE FIGURE P-802.1.1(4) INDIRECTLY CONNECTED ICE BIN FIGURE P-802.1.1(5) INDIRECTLY CONNECTED ICE MAKER AND BAR SINK FIGURE P-802.1.1(6) REFRIGERATED FOOD CASE DRAINS INDIRECTLY CONNECTING TO HUB DRAIN |
207 | FIGURE P-802.1.1(7) INDIRECT CONNECTIONS |
208 | FIGURE P-1003.3.5(1) HYDROMECHANICAL GREASE INTERCEPTOR FIGURE P-1003.3.5(2) HYDROMECHANICAL GREASE INTERCEPTOR FIGURE P-802.1.1(8) INDIRECT CONNECTIONS FIGURE P-802.1.1(9) INDIRECT CONNECTIONS FIGURE P-802.1.1(10) INDIRECT CONNECTIONS |
209 | FIGURE 802.1.2(1) FLOOR DRAIN IN FOOD STORAGE REFRIGERATOR (NONFREEZING) FIGURE 802.1.2(2) FLOOR DRAIN IN FOOD STORAGE FREEZER, AIR BREAK TERMINATION |
210 | FIGURE 802.1.2(3) FLOOR DRAIN IN FOOD STORAGE FREEZER, AIR GAP TERMINATIONFIGURE 802.1.3INDIRECT CONNECTION FOR POTABLE CLEAR-WATER WASTEAIR GAPBACKWASH FROM FILTERVENT FOR WASTERECEPTOR FIXTURETRAPTODISPOSALPOINTFIGURE 802.1.4SWIMMING POOL FIGURE 802.1.3 INDIRECT CONNECTION FOR POTABLE CLEAR-WATER WASTE FIGURE 802.1.4 SWIMMING POOL WASTE DISCHARGE THROUGH AIR GAP |
211 | FIGURE 802.1.5 INDIRECT CONNECTION—NONPOTABLE CLEAR-WATER WASTE |
212 | FIGURE 802.1.6 COMMERCIAL DISHWASHER INDIRECT WASTE CONNECTIONS WASTE RECEPTORMIN. MIN.= DIAMETER OF THEEFFECTIVE OPENINGFIGURE 802.3.1AIR GAP FIGURE 802.3.1 AIR GAP |
213 | FIGURE 802.3 TRAP REQUIREMENTS FOR INDIRECT WASTE PIPING FIGURE 802.3.2 AIR BREAK |
214 | FIGURE 802.4(1) WASTE RECEPTORS FIGURE 802.4(2) WASTE RECEPTORS |
215 | FIGURE 802.4(3) PROHIBITED LOCATIONS FOR WASTE RECEPTORS FIGURE 802.4.1(1) SHALLOW, FLAT BOTTOM WASTE RECEPTOR FIGURE 802.4.1(2) DEEP, ROUNDED-BOTTOM WASTE RECEPTOR |
216 | FIGURE 802.4.2 CLEAR-WATER WASTE RECEPTOR FIGURE 802.4.3 STANDPIPES |
217 | FIGURE 901.2(1) LOSS OF TRAP SEAL FIGURE 901.2(2) MAXIMUM TRAP SEAL RESTSTANCE FIGURE 903.1 VENT TERMINAL |
218 | FIGURE 903.5 SEPARATION OF VENT TERMINAL FIGURE 903.6 SIDEWALL VENT |
219 | FIGURE 904.1(1) REDUCTION OF STACK VENT CONNECTION FIGURE 904.1(2) STACK VENT FIGURE 904.1(3) REQUIRED VENT OUTDOORS |
220 | FIGURE 904.4 VENT CONNECTION AT BASE OF STACK FIGURE 904.5 VENT HEADERS |
221 | FIGURE 905.2 GRADE OF VENTS FIGURE 905.3 VENT CONNECTIONS |
222 | FIGURE 905.4 VERTICAL RISE OF VENT |
223 | FIGURE 905.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN FIGURE 905.5(2) PROPERLY CONNECTED VENT SERVING A DRAIN FIGURE 905.5(3) HORIZONTAL BRANCH VENT ELEVATION |
224 | FIGURE 906.1(1) VENT STACK SIZING FIGURE 906.1(2) VENT STACK SIZING FIGURE 906.1(3) STACK VENT SIZING |
225 | FIGURE 906.2(1) VENT SIZING FIGURE 906.2(2) VENT SIZING |
226 | FIGURE 906.2(3) VENT SIZING FIGURE 906.2(4) VENT SIZING |
227 | FIGURE 906.3(1) DEVELOPED LENGTH VENTS FIGURE 906.3(2) DEVELOPED LENGTH OF VENTS |
228 | FIGURE 906.4 COMMON BRANCH VENT FIGURE 906.5.1 SUMP VENT |
229 | FIGURE 907.2 VENT CONNECTIONS FOR HORIZONTAL OFFSET FIGURE 908.1 RELIEF VENT CONNECTION |
230 | FIGURE 909.1(1) DISTANCE FROM TRAP TO VENT FIGURE 909.1(2) MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT |
231 | FIGURE 909.2(1) TRAP TO VENT DISTANCE FOR WATER CLOSETS FIGURE 909.2(2) VENT CONNECTION |
232 | FIGURE 909.2(3) SELF-SIPHONING PHENOMENON FIGURE 909.3(1) CROWN VENTING FIGURE 909.3(2) MINIMUM TRAP-TO-VENT DISTANCE |
233 | FIGURE 910.1(1) INDIVIDUAL VENTS FIGURE 910.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS FIGURE 911.1 COMMON VENTS |
234 | FIGURE 911.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL |
235 | FIGURE 911.3 COMMON VENT WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS |
236 | FIGURE 912.1(1) HORIZONTAL WET VENTING OF BATHROOM FIXTURES FIGURE 912.1(2) HORIZONTAL WET VENT WITH INDIVIDUAL VENT FIGURE 912.1(3) HORIZONTAL WET VENT WITH COMMON VENTED FIXTURES UPSTREAM FIGURE 912.1(4) PROHIBITED CONNECTION OF TWO FIGURES UPSTREAM OF DRY-VENT CONNECTION FIGURE 912.1(5) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENTED FIXTURE CONNECTION- -FIGURE 912.1(6)HORIZONTAL WET FIGURE 912.1(6) HORIZONTAL WET VENT WITH COMMON VENT WITH AN ADDITIONAL DRY-VENTED FIXTURE |
237 | FIGURE 912.1(7) HORIZONTAL WET VENT WITH THREE ADDITIONAL INDEPENDENTLY VENTED FIXTURES FIGURE 912.1(8) HORIZONTAL WET VENT SIZING (PRIVATE BATH GROUP) FIGURE 912.1(9) HORIZONTAL WET VENT (PUBLIC BATH GROUP) FIGURE 912.1(10) HORIZONTAL WET VENT |
238 | FIGURE 912.1(11) HORIZONTAL WET VENT FIGURE 912.1(12) HORIZONTAL WET VENT FIGURE 912.(13) NONCOMPLIANT HORIZONTAL WET VENT |
239 | FIGURE 912.1(14) NONCOMPLIANT HORIZONTAL WET VENT FIGURE 912.1(15) NONCOMPLIANT HORIZONTAL WET VENT FIGURE 912.1(16) NONCOMPLIANT HORIZONTAL WET VENT FIGURE 912.1(17) NONCOMPLIANT HORIZONTAL WET VENT FIGURE 912.1(18) NONCOMPLIANT HORIZONTAL WET VENT |
240 | FIGURE 912.1(19) MULTIFLOOR WET VENTING FIGURE 912.1(20) SINGLE BATHROOM GROUP (PRIVATE) WET VENT FIGURE 912.1(21) DOUBLE BATHROOM GROUP (PRIVATE) WET VENT FIGURE 912.1(22) WET VENT VARIATIONS FOR A SINGLE BATHROOM GROUP |
241 | FIGURE 912.1(23) HORIZONTAL WET VENTING FIGURE 912.1(24) MULTIPLE INDIVIDUAL VENTS |
242 | FIGURE 912.1.1(1) VERTICAL WET VENT OF SINGLE BATHROOM GROUP FIGURE 912.1.1(2) VERTICAL WET VENT OF TWO BATHROOM GROUPS FIGURE 912.1.1(3) VERTICAL WET VENT OF TWO BATHROOM GROUPS |
243 | FIGURE 912.1.1(4) VERTICAL WET VENTING FIGURE 913.2(1) WASTE STACK VENT |
244 | FIGURE 913.2(2) WASTE STACK VENT FIGURE 913.3 WASTE STACK VENT OFFSETS AND STACK VENT CONNECTIONS |
245 | FIGURE 914.1(1) CIRCUIT VENTING |
246 | FIGURE 914.1.1 MULTIPLE CIRCUIT-VENTED BRANCHES FIGURE 914.2 BACK-TO-BACK WATER CLOSETS CIRCUIT VENTED FIGURE 914.3 SIZING A CIRCUIT-VENT SYSTEM |
247 | FIGURE 914.3.1 SIZING MULTIPLE CIRCUIT-VENTED BRANCHES FIGURE 914.4.1 CIRCUIT VENT WITH RELIEF VENT CONNECTION FIGURE 914.5(1) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS |
248 | FIGURE 914.5(2) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS FIGURE 915.2(1) COMBINATION WASTE AND VENT |
249 | FIGURE 915.2(2) COMBINATION WASTE AND VENT FIGURE 915.2(3) COMBINATION WASTE AND VENT |
250 | FIGURE 915.2(4) COMBINATION WASTE AND VENT |
251 | FIGURE 915.2(5) VERTICAL FIXTURE DRAIN COMPONENT IN COMBINATION WASTE AND VENT SYSTEM 915.2.3(1) COMBINATION WASTE AND VENT |
252 | FIGURE 915.2.3(2) COMBINATION WASTE AND VENT FIGURE 915.2.3(3) COMBINATION WASTE AND VENT |
253 | FIGURE 915.2.3(4) COMBINATION WASTE AND VENT FIGURE 915.2.3(5) COMBINATION WASTE AND VENT |
254 | FIGURE 916.2 ISLAND FIXTURE VENT FIGURE 917.3(1) WATER CLOSET WITHIN 18 INCHES OF STACK AND 3-INCH HORIZONTAL BRANCH CONNECTING TO WYE ON STACK FIGURE 917.3(2) WATER CLOSET WITHIN 18 INCHES OF STACK AND 3-INCH HORIZONTAL BRANCH CONNECTING TO SANITARY TEE ON STACK |
255 | FIGURE 917.4.1(1) WATER CLOSETS NOT MORE THAN 4 FEET FROM STACK WHEN BRANCH CONNECTS THROUGH WYE TO STACK |
256 | FIGURE 917.4.1(2) WATER CLOSETS NOT MORE THAN 8 FEET FROM STACK WHEN BRANCH CONNECTS THROUGH SANITARY TEE TO STACK |
257 | FIGURE 917.4.2 MAXIMUM HORIZONTAL DEVELOPED LENGTH FROM STACK FOR FIXTURES OTHER THAN WATER CLOSETS FIGURE 917.7 OFFSET VENTING REQUIREMENT FOR SINGLE-STACK VENT SYSTEM |
258 | FIGURE 917.8 LOWER TWO FLOORS ON SEPARATE STACK FIGURE 918.3.1(1) AIR ADMITTANCE—INDIVIDUAL VENT |
259 | FIGURE 919.1(1) PHILADELPHIA SINGLE STACK AND HORIZONTAL BRANCH DRAINS VENTED BY BRANCH VENTS OR SOIL AND WASTE STACKS |
260 | FIGURE 919.1(2) PHILADELPHIA SOIL OR WASTE STACK SYSTEM AND HORIZONTAL BRANCH DRAIN AND BRANCH VENT |
261 | FIGURE 919.1(3) CIRCUIT AND LOOP VENTING FOR FLOOR MOUNTED WATER CLOSETS AND SMALL FIXTURES |
262 | FIGURE 919.1(4) CIRCUIT AND LOOP VENTING FOR WALL HUNG WATER CLOSETS AND SMALL FIXTURES |
263 | FIGURE P-919.2.10 RELIEF VENT SIZING |
264 | FIGURE P-919.4.1 VELOCITY BREAKS IN BUILDINGS OVER 30 STORIES |
265 | FIGURE P-919.5.1 CONTINUOUS, LOOP AND CIRCUIT VENT |
266 | FIGURE P-919.5.2(1) BATHROOM GROUP W/ IDEAL BEND FIGURE P-919.5.2(2) WATER CLOSET WITHIN 48″ OF EXISTING STACK FIGURE P-919.5.3 BATHROOM GROUP W/ MERION FITTING FIGURE P-919.5.4 WATER CLOSET IN EXCESS OF 48″ OF EXISTING STACK |
267 | FIGURE P-919.6.1 SINGLE WASTE BRANCHES IN EXCESS OF 8′-0″ AND 12′-0″ VENTING REQUIREMENTS |
268 | FIGURE P-919.7.12 YOKE VENTING OFFSETS FIGURE P-919.7.3 SEPARATE VENTING FIGURE P-919.7.4 OFFSET OF SOIL STACK IN BUILDINGS 3-STORIES and LESS FIGURE P-919.8.1 COMMON VENT HEADER |
269 | FIGURE P-919.9.3 VENT STACK SIZING |
270 | FIGURE 1002.1(1) TRAP REQUIREMENTS FIGURE 1002.2 SLIP JOINTS IN TRAPS |
271 | FIGURE 1002.3 PROHIBITED TRAPS FIGURE P-1002.4.1.1 TRAP PRIMERS IN RECEIVERS NOT RECEIVING CONSTANT WATER DISCHARGE |
272 | FIGURE P-1002.6 BUILDING (HOUSE) TRAPS |
273 | FIGURE 1002.7 INSTALLATION OF TRAP FIGURE 1003.2 INTERCEPTORS AND SEPARATORS FIGURE 1003.3(1) TYPICAL GRAVITY-TYPE GREASE INTERCEPTOR |
274 | FIGURE 1003.3.1(1) TYPICAL SINGLE-FIXTURE INSTALLATIONS FIGURE 1003.3.1(2) GREASE INTERCEPTOR FOR FIXTURES |
275 | FIGURE 1003.1(3) AUTOMATIC GREASE INTERCEPTOR FIGURE 1003.3.1(4) SENSOR-CONTROLLED GREASE RECOVERY DEVICE |
276 | FIGURE 1003.3.1(5) BIOREMEDIATION GREASE INTERCEPTOR FIGURE 1003.3.2 FOOD WASTE DISPOSER CONNECTING TO GREASE INTERCEPTOR |
277 | FIGURE 1003.3.5.2 FLOW CONTROL DEVICE FIGURE 1003.9 VENTING OF INTERCEPTORS AND SEPARATORS |
278 | FIGURE 1101.7 ROOF DRAIN WITH SCUPPER OVERFLOW |
279 | FIGURE P-1103.1(1) PARKING GARAGE DRAINAGE ONE-PIPE SYSTEM FIGURE P-1103.1(2) STORM WATER CATCH BASIN DETAIL |
280 | FIGURE 1103.1 TRAPS ON STORM DRAINS THAT CONNECT TO EXISTING COMBINED SANITARY AND STORM SEWER SYSTEMS FIGURE 1106.4 VERTICAL WALLS |
281 | FIGURE 1108.1 SECONDARY ROOF DRAINAGE NOT REQUIRED FIGURE 1108.2(1) SEPARATE PRIMARY AND SECONDARY ROOF DRAIN |
282 | FIGURE 1108.2(2) PROHIBITED SECONDARY ROOF DRAIN CONNECTION FIGURE 1110.4 MINIMUM NUMBER OF ROOF DRAINS FOR CONTROLLED FLOW |
283 | FIGURE 1111.1(2) SUBSOIL DRAIN |
285 | APPENDIX G LICENSING REQUIREMENTS SECTION G101 DEFINITIONS SECTION G102 GENERAL LICENSE REQUIREMENTS SECTION G103 MASTER PLUMBER |
286 | SECTION G104 JOURNEYMAN PLUMBER SECTION G105 APPRENTICE PLUMBER SECTION G106 FEES SECTION G107 RULES OF CONDUCT |
287 | SECTION G108 LICENSE SUSPENSION AND REVOCATION; OTHER REMEDIES SECTION G109 PENALTIES |
289 | INDEX |
301 | HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR PLUMBING CODE |
302 | ICC MEMBERSHIP |
303 | ICC ASSESSMENT CENTER |
304 | ICC EVALUATION SERVICE |