RI BuildingCode 2019 1stptg
$83.42
Rhode Island Building Code, 1st Printing
Published By | Publication Date | Number of Pages |
RI | 2019 | 751 |
This is a fully integrated code based on the 2015 IBC.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2019 RHODE ISLAND BUILDING CODE |
2 | 2019 RHODE ISLAND BUILDING CODE BASED ON THE 2015 INTERNATIONAL BUILDING CODE® TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
10 | EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE |
20 | LEGISLATION |
22 | RHODE ISLAND STATE BUILDING CODE SBC-1 STATE BUILDING CODE |
23 | REGULATION SBC-1 STATE BUILDING CODE AUGUST 1, 2019 |
24 | STATE OF RHODE ISLAND BUILDING CODE STANDARDS COMMITTEE |
25 | STATE BUILDING CODE REGULATIONS – 2019 |
26 | TABLE OF CONTENTS |
34 | CHAPTER 23–27.3 STATE BUILDING CODE § 23-27.3-100.0 SCOPE § 23-27.3-100.1 SHORT TITLE – APPLICABILITY § 23-27.3-100.1.1 CHAPTER TITLE – APPLICABILITY § 23-27.3-100.1.2 PURPOSE § 23-27.3-100.1.3 CREATION OF THE STATE BUILDING CODE STANDARDS COMMITTEE |
35 | § 23-27.3-100.1.4 APPOINTMENT AND QUALIFICATIONS OF THE COMMITTEE § 23-27.3-100.1.5 BUILDING CODE – ADOPTION AND PROMULGATION BY COMMITTEE |
36 | 23-27.3-100.1.5.1 HOUSING AND MAINTENANCE CODE § 23-27.3-100.1.5.2 EXISTING CODES § 23-27.3-100.1.5.3 STATE REHABILITATION BUILDING AND FIRE CODE FOR EXISTING BUILDINGS AND STRUCTURES § 23-27.3-100.1.5.4 STATE ENERGY CONSERVATION CODE |
37 | § 23-27.3-100.1.5.5 HURRICANE, STORM AND FLOOD STANDARDS § 23-27.3-100.1.6 COMMITTEE AS BOARD OF STANDARDS AND APPEALS – POWERS AND DUTIES – APPEALS § 23-27.3-100.1.7 EFFECT OF LOCAL CODES – REPEAL OF LOCAL AUTHORITY § 23-27.3-100.1.8 SEVERABILITY § 23-27.3-100.2 APPLICATION OF REFERENCES § 23-27.3-100.3 CONSTRUCTION § 23-27.3-100.4 SPECIALIZED CODES INCORPORATED |
38 | § 23-27.3-101.0 MATTERS COVERED § 23-27.3-101.1 EXEMPTION FOR ORDINARY REPAIRS § 23-27.3-101.2 MATTERS NOT COVERED § 23-27.3-101.2.1 PROPOSED BUILDINGS § 23-27.3-101.2.2 BUILDINGS AND STRUCTURES, EXISTING AND UNDER CONSTRUCTION § 23-27.3-101.3 ZONING RESTRICTIONS § 23-27.3-102.0 ORDINARY REPAIRS § 23-27.3-103.0 INSTALLATION OF SERVICE EQUIPMENT § 23-27.3-104.0 MAINTENANCE |
39 | § 23-27.3-104.1 OWNER RESPONSIBILITY § 23-27.3-105.0 CHANGE IN EXISTING USE § 23-27.3-105.1 CONTINUATION OF EXISTING USE § 23-27.3-105.2 CHANGE IN USE AND OCCUPANCY § 23-27.3-105.3 PART CHANGE IN USE § 23-27.3-105.4 REESTABLISHMENT OF A PRIOR USE § 23-27.3-106.0 EXISTING STRUCTURES § 23-27.3-106.1 SUBSTANTIAL IMPROVEMENTS § 23-27.3-106.2 SUBSTANTIAL DAMAGES EXCEEDING FIFTY PERCENT |
40 | § 23-27.3-106.3 IMPROVEMENTS AND DAMAGES BETWEEN TWENTY-FIVE AND FITY PERCENT OF VALUE § 23-27.3-106.4 IMPROVEMENTS OR DAMAGES UNDER TWENTY-FIVE PERCENT OF VALUE § 23-27.3-106.5 PHYSICAL VALUE § 23-27.3-107.0 DEPARTMENT OF BUILDING INSPECTION § 23-27.3-107.1 LOCAL BUILDING OFFICIAL – APPOINTMENT § 23-27.3-107.1.1 LOCAL INSPECTOR – § 23-27.3-107.2 ALTERNATE LOCAL BUILDING OFFICIAL |
41 | § 23-27.3-107.3 APPOINTMENT OF PERSONNEL BY STATE BUILDING COMMISSIONER § 23-27.3-107.4 QUALIFICATIONS AND DUTIES OF THE STATE BUILDING COMMISSIONER § 23-27.3-107.5 LOCAL BUILDING OFFICIAL – QUALIFICATIONS – POWERS AND DUTIES § 23-27.3-107.6 CERTIFICATION OF LOCAL BUILDING OFFICIALS – EDUCATIONAL PROGRAMS |
42 | § 23-27.3-107.7 RECERTIFICATION AND CONTINUING EDUCATION § 23-27.3-107.8 RESTRICTION ON EMPLOYEES’ ACTIVITIES § 23-27.3-107.9 RELIEF FROM PERSONAL RESPONSIBILITY § 23-27.3-108.0 DUTIES AND POWERS OF THE BUILDING OFFICIAL AND THE STATE BUILDING COMMISSIONER § 23-27.3-108.1 LOCAL BUILDING OFFICIAL – ENFORCEMENT DUTIES § 23-27.3-108.1.1 APPLICATIONS AND PERMITS § 23-27.3-108.1.3 NEW MATERIALS AND METHODS OF CONSTRUCTION |
43 | § 23-27.3-108.1.3.1 TEST RESULTS § 23-27.3-108.1.3.2 RETESTING § 23-27.3-108.1.4 INSPECTIONS § 23-27.3-108.1.5 REPEALED § 23-27.3-108.1.6 ADMINISTRATIVE PROCEDURES § 23-27.3-108.1.7 DEPARTMENT RECORDS § 23-27.3-108.1.8 REPORTS § 23-27.3-108.2 STATE BUILDING COMMISSIONER’S DUTIES |
44 | § 23-27.3-108.2.0.1 REPEALED § 23-27.3-108.2.1 DUTIES OF COMMITTEE § 23-27.3-108.2.2 COMPENSATION OF COMMITTEE MEMBERS § 23-27.3-108.2.3 EMERGENCY PROCEDURES § 23-27.3-108.2.4 MUNICIPAL ADVISORY COUNCIL ON STATEWIDE PERMITTING § 23-27.3-109.0 COMMITTEE § 23-27.3-109.1 COMMITTEE’S RULE MAKING AUTHORITY – LEGISLATIVE REPORT – LEGISLATIVE COMMITTEE |
45 | § 23-27.3-109.1.1 COMMITTEE – LICENSING OF LABORATORIES AND TEST PERSONNEL § 23-27.3-109.1.2 COMMITTEE – REGULATION OF MANUFACTURED BUILDINGS § 23-27.3-109.1.3 ADOPTION OF FEDERAL STANDARDS FOR MANUFACTURED HOMES § 23-27.3-109.1.3.1 INSPECTION OF MANUFACTURED HOMES MANUFACTURERS § 23-27.3-109.1.3.2 PENALTIES FOR VIOLATIONS AS TO MANUFACTURED HOMES |
46 | § 23-27.3-109.1.3.3 MONITORING INSPECTION FEE § 23-27.3-109.1.3.4 REPORTS OF MANUFACTURED HOME MANUFACTURERS, DISTRIBUTORS, AND DEALERS § 23-27.3-109.1.3.5 TEMPORARY GREENHOUSE DEFINED § 23-27.3-109.1.4 REPEALED § 23-27.3-109.2 ACCEPTED ENGINEERING PRACTICE § 23-27.3-109.3 PROPOSING AMENDMENTS TO RULES AND REGULATIONS § 23-27.3-110.0 MODIFICATIONS AND VARIANCES § 23-27.3-111.0 NEW AND ALTERED BUILDING AND STRUCTURE – INSPECTIONS § 23-27.3-111.1 PRELIMINARY INSPECTION § 23-27.3-111.2 INSPECTION |
47 | § 23-27.3-111.3 MANUFACTURING BUILDINGS § 23-27.3-111.3.1 PLANT INSPECTION § 23-27.3-111.3.2 INSTALLATION SITE INSPECTION § 23-27.3-111.4 EXISTING BUILDINGS § 23-27.3-111.4.1 PERIODIC INSPECTIONS § 23-27.3-111.4.2 REPEALED – § 23-27.3-111.5 FINAL INSPECTION § 23-27.3-111.6 INSPECTION SERVICES § 23-27.3-111.7 COORDINATION OF INSPECTIONS § 23-27.3-112.0 RIGHT OF ENTRY § 23-27.3-112.1 OFFICIAL IDENTIFICATION CARD |
48 | § 23-27.3-112.2 MUNICIPAL COOPERATION § 23-27.3-113.0 APPLICATION FOR PERMIT § 23-27.3-113.1 WHEN PERMIT IS REQUIRED § 23-27.3-113.1.1 ISSUANCE OF PERMITS FOR SIDING § 23-27.3-113.2 FORM OF APPLICATION – § 23-27.3-113.3 BY WHOM APPLICATION IS MADE – § 23-27.3-113.3.1 APPLICATIONS FOR WORK REQUIRING LICENSED WORKERS § 23-27.3-113.3.2 APPLICATIONS FOR WORK REQUIRING REGISTERED WORKERS |
49 | § 23-27.3-113.4 DESCRIPTION OF WORK § 23-27.3-113.5 PLANS AND SPECIFICATIONS § 23-27.3-113.5.1 REPEALED § 23-27.3-113.6 PLOT PLAN § 23-27.3-113.6.1 APPROVAL OF AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM § 23-27.3-113.7 ENGINEERING DETAILS § 23-27.3-113.8 AMENDMENTS TO APPLICATION § 23-27.3-113.9 TIME LIMITATION ON APPLICATION § 23-27.3-114.0 PERMITS § 23-27.3-114.1 ACTION ON APPLICATION |
50 | § 23-27.3-114.1.1 REPORTS TO ASSESSORS § 23-27.3-114.2 EXPIRATION OF PERMIT § 23-27.3-114.3 PREVIOUS APPROVALS |
51 | § 23-27.3-114.3.1 DRAWINGS AND SPECIFICATIONS § 23-27.3-114.4 BUILDING OFFICIAL TO SIGN PERMIT § 23-27.3-114.5 APPROVED PLANS § 23-27.3-114.6 REVOCATION OF PERMITS § 23-27.3-114.7 APPROVAL IN PART § 23-27.3-114.8 POSTING OF PERMIT § 23-27.3-114.9 NOTICE OF BUILDING START § 23-27.3-115.0 CONDITIONS OF PERMIT § 23-27.3-115.1 COMPLIANCE WITH CODE § 23-27.3-115.2 COMPLIANCE WITH PERMIT § 23-27.3-115.3 COMPLIANCE WITH PLOT PLAN § 23-27.3-115.4 CHANGE IN PLOT PLAN |
52 | § 23-27.3-115.5 DISMISSAL OF CONTRACTOR OR SUBCONTRACTOR § 23-27.3-116.0 MOVING, RAISING, SHORING, OR DEMOLITION OF BUILDINGS § 23-27.3-116.1 SERVICE CONNECTIONS § 23-27.3-116.2 BUILDINGS TO BE RODENT-ERADICATED PRIOR TO DEMOLITION § 23-27.3-116.3 DESCRIPTION AND INSPECTION OF BUILDINGS – TRAVEL ROUTE § 23-27.3-116.4 AGREEMENT CONDITION TO MOVING § 23-27.3-116.5 PUBLIC UTILITIES, WIRES, POLES, TREES AND SHRUBS § 23-27.3-116.6 MOVING TO BE CONTINUOUS § 23-27.3-116.7 WATCHPERSON AND LIGHTS DURING MOVING |
53 | § 23-27.3-116.8 BONDS AND LIABILITY INSURANCE § 23-27.3-116.9 SHORING § 23-27.3-117.0 REMOVAL OF STRUCTURES § 23-27.3-117.1 LOT REGULATION § 23-27.3-118.0 FEES § 23-27.3-118.1 SPECIAL FEES § 23-27.3-118.2 RAMPS FOR DISABLED PERSONS § 23-27.3-119.0 FEE COMPUTATION § 23-27.3-120.0 CERTIFICATE OF USE AND OCCUPANCY § 23-27.3-120.1 NEW BUILDINGS § 23-27.3-120.2 BUILDINGS HEREAFTER ALTERED |
54 | § 23-27.3-120.3 EXISTING BUILDINGS § 23-27.3-120.4 CHANGES IN USE AND OCCUPANCY § 23-27.3-120.5 TEMPORARY OCCUPANCY § 23-27.3-120.6 CONTENTS OF CERTIFICATE § 23-27.3-121.0 POSTING BUILDINGS § 23-27.3-121.1 POSTED USE AND OCCUPANCY |
55 | § 23-27.3-121.2 POSTED OCCUPANCY LOAD § 23-27.3-121.3 FURNISHING OF POSTED SIGNS § 23-27.3-121.4 PERIODIC INSPECTION FOR POSTING § 23-27.3-122.0 VIOLATIONS § 23-27.3-122.1 NOTICE OF VIOLATION § 23-27.3-122.1.2 NOTICE OR ORDERS – SERVICE AND CONTENT § 23-27.3-122.2 PROSECUTION OF VIOLATION § 23-27.3-122.3 PENALTIES § 23-27.3-122.4 ABATEMENT OF VIOLATIONS |
56 | § 23-27.3-123.0 STOP-WORK ORDER § 23-27.3-123.1 NOTICE TO OWNER § 23-27.3-123.1.1 POSTING OF ORDER § 23-27.3-123.2 UNLAWFUL CONTINUANCE § 23-27.3-124.0 UNSAFE STRUCTURES – GENERAL PROVISIONS § 23-27.3-124.1 UNSAFE CONDITIONS § 23-27.3-124.2 NOTICE OF UNSAFE CONDITION |
57 | § 23-27.3-124.3 APPEALS § 23-27.3-124.4 RESTORATION OF UNSAFE BUILDINGS § 23-27.3-124.4.1 COMPLIANCE § 23-27.3-124.5 DISREGARD OF UNSAFE NOTICE § 23-27.3-124.6 BOARDING |
58 | § 23-27.3-124.6.1 DISCONNECTION OF UTILITIES § 23-27.3-124.6.2 REMOVAL OF DEBRIS AND RUBBISH § 23-27.3-125.0 EMERGENCY MEASURES § 23-27.3-125.1 VACATING BUILDINGS § 23-27.3-125.2 TEMPORARY SAFEGUARDS § 23-27.3-125.3 CLOSING STREETS § 23-27.3-125.4 EMERGENCY REPAIRS § 23-27.3-125.5 HAZARDOUS BUILDINGS § 23-27.3-125.6 COSTS OF EMERGENCY REPAIRS § 23-27.3-125.7 LIEN FOR EMERGENCY REPAIRS § 23-27.3-126.0 APPEALS FROM ORDERS IN REGARD TO UNSAFE BUILDINGS |
59 | § 23-27.3-126.1 APPLICATION FOR REVIEW § 23-27.3-126.2 PROCEDURE § 23-27.3-126.3 FINDINGS § 23-27.3-127.0 STATE AND LOCAL BOARDS OF APPEALS § 23-27.3-127.1 COMMITTEE TO SERVE AS A BOARD OF STANDARDS AND APPEALS |
60 | § 23-27.3-127.1.1 STAY OF PROCEEDINGS § 23-27.3-127.1.2 GRANTING VARIANCE § 23-27.3-127.1.3 ADDITIONAL POWERS § 23-27.3-127.1.4 PROCEDURES – RECORD OF VARIANCES |
61 | § 23-27.3-127.2 LOCAL BOARD OF APPEALS § 23-27.3-127.2.1 MEMBERSHIP AND LOCAL BOARD § 23-27.3-127.2.2 STAY OF PROCEEDINGS § 23-27.3-127.2.3 GRANTING VARIANCE § 23-27.3-127.2.4 ADDITIONAL POWERS § 23-27.3-127.2.5 PROCEDURES |
62 | § 23-27.3-127.2.6 LOCAL DECISION TRANSMITTED TO STATE BOARD § 23-27.3-128.0 DESIGN AND CONSTRUCTION PROCEDURES § 23-27.3-128.1 SCOPE § 23-27.3-128.1.1 OWNER’S RESPONSIBILITIES § 23-27.3-128.1.2 – 23-27.3-128.1.5 REPEALED § 23-27.3-128.2 REPEALED § 23-27.3-128.2.1 DRAWINGS AND SPECIFICATIONS § 23-27.3-128.2.2 RESPONSIBILITIES |
63 | § 23-27.3-128.2.3 REPORTING § 23-27.3-128.3 CONSTRUCTION CONTRACTOR RESPONSIBILITIES § 23-27.3-128.4 TESTING REQUIRED § 23-27.3-128.5 BUILDING OFFICIAL’S RESPONSIBILITIES § 23-27.3-128.5.1 WAIVER OF PLAN EXAMINATION § 23-27.3-128.5.2 WAIVER OF DETAILED FIELD INSPECTION |
64 | § 23-27.3-128.5.3 INSPECTION WAIVER – UTILIZATION § 23-27.3-128.5.4 BUILDING PERMIT ISSUANCE OR REQUIREMENTS § 23-27.3-128.6 SPECIAL TECHNICAL SERVICES § 23-27.3-128.7 FEES AND COSTS § 23-27.3-129.0, 23-27.3-129.1 REPEALED § 23-27.3-129.2 REPEALED § 23-27.3-129.3 REPEALED § 23-27.3-200.0 SAVINGS CLAUSE § 23-27.3-300.0 PUBLICATION OF CODE § 23-27.3-400.0 SEVERABILITY |
65 | § 23-27.3-401.0 SALE OF PRESSURE VESSEL § 23-27.3-500.0 EFFECTIVE DATE OF CODE § 23-27.3-501.0, 23-27.3-502.0 REPEALED § 23-27.3-503.0, 23-27.3-504.0 [OBSOLETE] § 23-27.3-505.0 REPEALED § 23-27.3-506.0 [OBSOLETE] § 23-27.3-600.0 FRESH WATER WETLANDS § 23-27.3-700.0 REPEALED § 23-27.3-701.0 BABY CHANGING TABLES |
66 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL |
67 | SECTION 102 APPLICABILITY PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL |
68 | SECTION 105 PERMITS |
70 | SECTION 106 FLOOR AND ROOF DESIGN LOADS SECTION 107 SUBMITTAL DOCUMENTS |
71 | SECTION 108 TEMPORARY STRUCTURES AND USES SECTION 109 FEES |
72 | SECTION 110 INSPECTIONS |
73 | SECTION 111 CERTIFICATE OF OCCUPANCY SECTION 112 SERVICE UTILITIES SECTION 113 BOARD OF APPEALS SECTION 114 VIOLATIONS |
74 | SECTION 115 STOP WORK ORDER SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT |
76 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINITIONS |
106 | CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION SECTION 301 GENERAL SECTION 302 CLASSIFICATION SECTION 303 ASSEMBLY GROUP A |
107 | SECTION 304 BUSINESS GROUP B SECTION 305 EDUCATIONAL GROUP E SECTION 306 FACTORY GROUP F |
108 | SECTION 307 HIGH-HAZARD GROUP H |
110 | TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
111 | TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
112 | [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD |
113 | SECTION 308 INSTITUTIONAL GROUP I |
115 | SECTION 309 MERCANTILE GROUP M SECTION 310 RESIDENTIAL GROUP R |
116 | SECTION 311 STORAGE GROUP S SECTION 312 UTILITY AND MISCELLANEOUS GROUP U |
118 | CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS |
122 | SECTION 403 HIGH-RISE BUILDINGS |
123 | TABLE 403.2.4 MINIMUM BOND STRENGTH |
125 | SECTION 404 ATRIUMS |
126 | SECTION 405 UNDERGROUND BUILDINGS |
127 | SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES |
129 | TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT |
131 | SECTION 407 GROUP I-2 |
134 | SECTION 408 GROUP I-3 |
136 | SECTION 409 MOTION PICTURE PROJECTION ROOMS |
137 | SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS |
139 | SECTION 411 SPECIAL AMUSEMENT BUILDINGS SECTION 412 AIRCRAFT-RELATED OCCUPANCIES |
140 | TABLE 412.3.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS |
141 | [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS |
142 | TABLE 412.7 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE SECTION 413 COMBUSTIBLE STORAGE |
143 | SECTION 414 HAZARDOUS MATERIALS |
144 | [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS |
145 | [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA |
146 | [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5 |
148 | [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED |
151 | [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5 |
156 | SECTION 416 APPLICATION OF FLAMMABLE FINISHES SECTION 417 DRYING ROOMS SECTION 418 ORGANIC COATINGS SECTION 419 LIVE/WORK UNITS |
157 | SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4 |
158 | SECTION 421 HYDROGEN FUEL GAS ROOMS SECTION 422 AMBULATORY CARE FACIILITIES |
159 | SECTION 423 STORM SHELTERS SECTION 424 CHILDREN’S PLAY STRUCTURES |
160 | SECTION 425 HYPERBARIC FACILITIES SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE SECTION 427 MANUFACTURED HOMES SECTION 428 MODULAR CONSTRUCTION |
162 | CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS SECTION 501 GENERAL SECTION 502 DEFINITIONS SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES |
163 | TABLE 504.3a ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS |
164 | TABLE 504.4a, b ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE |
165 | TABLE 504.4a, b—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE |
166 | SECTION 506 BUILDING AREA EQUATION 5-1 |
167 | TABLE 506.2a, b ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET |
168 | TABLE 506.2a, b—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET |
169 | TABLE 506.2a,b—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET EQUATION 5-2 EQUATION 5-3 |
170 | EQUATION 5-4 EQUATION 5-5 SECTION 507 UNLIMITED AREA BUILDINGS |
172 | SECTION 508 MIXED USE AND OCCUPANCY |
173 | TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) SECTION 509 INCIDENTAL USES |
174 | TABLE 509 INCIDENTAL USES |
175 | SECTION 510 SPECIAL PROVISIONS |
178 | CHAPTER 6 TYPES OF CONSTRUCTION SECTION 601 GENERAL TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) SECTION 602 CONSTRUCTION CLASSIFICATION |
179 | TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES |
180 | SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION |
182 | CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 701 GENERAL SECTION 702 DEFINITIONS SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS |
183 | SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS |
185 | SECTION 705 EXTERIOR WALLS TABLE 705.2 MINIMUM DISTANCE OF PROJECTION |
186 | EQUATION 7-1 |
187 | FIGURE 705.7 EQUIVALENT OPENING FACTOR EQUATION 7-2 |
188 | TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION |
189 | SECTION 706 FIRE WALLS |
190 | TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS |
192 | SECTION 707 FIRE BARRIERS TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS |
193 | SECTION 708 FIRE PARTITIONS |
194 | SECTION 709 SMOKE BARRIERS |
195 | SECTION 710 SMOKE PARTITIONS SECTION 711 FLOOR AND ROOF ASSEMBLIES |
196 | SECTION 712 VERTICAL OPENINGS |
197 | SECTION 713 SHAFT ENCLOSURES |
199 | SECTION 714 PENETRATIONS |
202 | SECTION 715 FIRE-RESISTANT JOINT SYSTEMS SECTION 716 OPENING PROTECTIVES |
203 | TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES |
205 | TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
206 | TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
208 | TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS SECTION 717 DUCTS AND AIR TRANSFER OPENINGS |
209 | TABLE 717.3.2.1 FIRE DAMPER RATING |
213 | SECTION 718 CONCEALED SPACES |
215 | SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS |
216 | SECTION 721 PRESCRIPTIVE FIRE RESISTANCE |
217 | SECTION 722 CALCULATED FIRE RESISTANCE TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING |
218 | TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
219 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
220 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
221 | TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
222 | TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
223 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
224 | TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
225 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
226 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
227 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
228 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
229 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
230 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
231 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
232 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
233 | TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
234 | TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
235 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
236 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
237 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
238 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
239 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
240 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
241 | EQUATION 7-3 EQUATION 7-4 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS |
242 | TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4 TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION |
243 | TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL |
244 | TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches) FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS EQUATION 7-5 FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS |
245 | FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES |
246 | FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches) TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches) |
247 | TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE) TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS |
248 | TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS EQUATION 7-6 |
249 | EQUATION 7-7 TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches) TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches) EQUATION 7-8 |
250 | EQUATION 7-9 TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS |
251 | TABLE 722.4.1(3) VALUES OF Rn 0.59 TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a TABLE 722.4.1(5) REINFORCED MASONRY LINTELS TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS EQUATION 7-10 EQUATION 7-11 |
252 | FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS EQUATION 7-12 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS |
253 | FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS |
254 | FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS EQUATION 7-13 |
255 | EQUATION 7-14 EQUATION 7-15 EQUATION 7-16 |
256 | FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS EQUATION 7-17 |
257 | TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS TABLE 722.5.1(2) PROPERTIES OF CONCRETE |
258 | TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
259 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
260 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
261 | TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
262 | TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
263 | TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS |
264 | TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] |
265 | TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] |
266 | TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES |
267 | TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION |
268 | CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL SECTION 802 DEFINITIONS SECTION 803 WALL AND CEILING FINISHES |
270 | TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY |
271 | SECTION 804 INTERIOR FLOOR FINISH SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION SECTION 806 DECORATIVE MATERIALS AND TRIM |
272 | SECTION 807 INSULATION SECTION 808 ACOUSTICAL CEILING SYSTEMS |
274 | CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL |
275 | SECTION 902 DEFINITIONS SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
277 | [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA |
279 | [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS |
281 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS |
284 | SECTION 905 STANDPIPE SYSTEMS |
286 | SECTION 906 PORTABLE FIRE EXTINGUISHERS SECTION 907 FIRE ALARM AND DETECTION SYSTEMS SECTION 908 EMERGENCY ALARM SYSTEMS |
287 | SECTION 909 SMOKE CONTROL SYSTEMS |
289 | EQUATION 9-1 EQUATION 9-2 |
295 | SECTION 910 SMOKE AND HEAT REMOVAL |
296 | EQUATION 9-3 EQUATION 9-4 SECTION 911 FIRE COMMAND CENTER |
297 | SECTION 912 FIRE DEPARTMENT CONNECTIONS |
298 | SECTION 913 FIRE PUMPS |
299 | SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES SECTION 915 CARBON MONOXIDE DETECTION SECTION 916 EMERGENCY RESPONDER RADIO COVERAGE |
300 | CHAPTER 10 MEANS OF EGRESS SECTION 1001 ADMINISTRATION SECTION 1002 DEFINITIONS |
301 | SECTION 1003 GENERAL MEANS OF EGRESS |
302 | SECTION 1004 OCCUPANT LOAD TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT |
303 | SECTION 1005 MEANS OF EGRESS SIZING |
304 | SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS |
305 | TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY |
306 | TABLE 1006.3.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY TABLE 1006.3.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION |
307 | 1006.3.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES SECTION 1008 MEANS OF EGRESS ILLUMINATION |
308 | SECTION 1009 ACCESSIBLE MEANS OF EGRESS |
311 | SECTION 1010 DOORS, GATES AND TURNSTILES |
312 | TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS |
318 | SECTION 1011 STAIRWAYS |
321 | SECTION 1012 RAMPS |
322 | SECTION 1013 EXIT SIGNS |
323 | SECTION 1014 HANDRAILS |
325 | SECTION 1015 GUARDS |
326 | SECTION 1016 EXIT ACCESS |
327 | SECTION 1017 EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa |
328 | SECTION 1018 AISLES SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS |
329 | SECTION 1020 CORRIDORS TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING TABLE 1020.2 MINIMUM CORRIDOR WIDTH |
330 | SECTION 1021 EGRESS BALCONIES |
331 | SECTION 1022 EXITS SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS |
333 | SECTION 1024 EXIT PASSAGEWAYS SECTION 1025 LUMINOUS EGRESS PATH MARKINGS |
335 | SECTION 1026 HORIZONTAL EXITS SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS |
336 | SECTION 1028 EXIT DISCHARGE |
337 | SECTION 1029 ASSEMBLY |
338 | TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY |
341 | TABLE 1029.12.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS |
344 | SECTION 1030 EMERGENCY ESCAPE AND RESCUE |
346 | CHAPTER 11 ACCESSIBILITY SECTION 1101 GENERAL SECTION 1102 DEFINITIONS SECTION 1103 SCOPING REQUIREMENTS |
347 | SECTION 1104 ACCESSIBLE ROUTE |
348 | SECTION 1105 ACCESSIBLE ENTRANCES SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES |
349 | TABLE 1106.1 ACCESSIBLE PARKING SPACES SECTION 1107 DWELLING UNITS AND SLEEPING UNITS |
351 | TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS |
353 | SECTION 1108 SPECIAL OCCUPANCIES |
354 | TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS |
355 | TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES |
356 | SECTION 1109 OTHER FEATURES AND FACILITIES |
358 | TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES |
359 | SECTION 1110 RECREATIONAL FACILITIES |
360 | TABLE 1110.4.9.1 BOAT SLIPS |
361 | SECTION 1111 SIGNAGE |
362 | SECTION 1112 CHILDREN’S FEATURES |
364 | CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1201 GENERAL SECTION 1202 DEFINITIONS SECTION 1203 VENTILATION |
365 | TABLE 1203.3 INSULATION FOR CONDENSATION CONTROL |
366 | SECTION 1204 TEMPERATURE CONTROL SECTION 1205 LIGHTING |
367 | SECTION 1206 YARDS OR COURTS SECTION 1207 SOUND TRANSMISSION SECTION 1208 INTERIOR SPACE DIMENSIONS |
368 | SECTION 1209 ACCESS TO UNOCCUPIED SPACES SECTION 1210 TOILET AND BATHROOM REQUIREMENTS |
370 | CHAPTER 13 ENERGY EFFICIENCY SECTION 1301 GENERAL |
372 | CHAPTER 14 EXTERIOR WALLS SECTION 1401 GENERAL SECTION 1402 DEFINITIONS SECTION 1403 PERFORMANCE REQUIREMENTS |
373 | SECTION 1404 MATERIALS |
374 | SECTION 1405 INSTALLATION OF WALL COVERINGS TABLE 1405.3.2 CLASS III VAPOR RETARDERS |
375 | TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS |
379 | SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS |
380 | TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS SECTION 1407 METAL COMPOSITE MATERIALS (MCM) |
382 | TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS |
383 | SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL) |
384 | SECTION 1410 PLASTIC COMPOSITE DECKING |
386 | CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL SECTION 1502 DEFINITIONS SECTION 1503 WEATHER PROTECTION |
387 | SECTION 1504 PERFORMANCE REQUIREMENTS TABLE 1504.1.1 CLASSIFICATION OF ASPHALT SHINGLES |
388 | TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION SECTION 1505 FIRE CLASSIFICATION TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION |
389 | SECTION 1506 MATERIALS SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS |
391 | TABLE 1507.2.9.2 VALLEY LINING MATERIAL |
392 | TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT |
393 | TABLE 1507.4.3(1) METAL ROOF COVERINGS TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE |
395 | TABLE 1507.7.6 SLATE SHINGLE HEADLAP |
396 | TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
397 | TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION |
398 | TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS |
399 | TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS |
400 | TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS |
401 | SECTION 1508 ROOF INSULATION [BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK SECTION 1510 ROOFTOP STRUCTURES |
404 | SECTION 1511 REROOFING SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES |
406 | CHAPTER 16 STRUCTURAL DESIGN SECTION 1601 GENERAL SECTION 1602 DEFINITIONS AND NOTATIONS SECTION 1603 CONSTRUCTION DOCUMENTS |
407 | SECTION 1604 GENERAL DESIGN REQUIREMENTS |
408 | TABLE 1604.3 DEFLECTION LIMITS |
410 | TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES SECTION 1605 LOAD COMBINATIONS |
411 | EQUATION 16-1 EQUATION 16-2 EQUATION 16-3 EQUATION 16-4 EQUATION 16-5 EQUATION 16-6 EQUATION 16-7 EQUATION 16-8 EQUATION 16-9 EQUATION 16-10 EQUATION 16-11 EQUATION 16-12 EQUATION 16-13 EQUATION 16-14 EQUATION 16-15 EQUATION 16-16 |
412 | EQUATION 16-17 EQUATION 16-18 EQUATION 16-19 EQUATION 16-20 EQUATION 16-21 EQUATION 16-22 SECTION 1606 DEAD LOADS SECTION 1607 LIVE LOADS |
413 | TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg |
414 | TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg |
416 | EQUATION 16-23 TABLE 1607.10.1 LIVE LOAD ELEMENT FACTOR, KLL |
417 | EQUATION 16-24 EQUATION 16-25 EQUATION 16-26 EQUATION 16-27 EQUATION 16-28 EQUATION 16-29 EQUATION 16-30 EQUATION 16-31 EQUATION 16-32 |
419 | SECTION 1608 SNOW LOADS SECTION 1609 WIND LOADS |
420 | TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS |
421 | TABLE 1608.1 BASIC WIND SPEEDS |
422 | FIGURE 1608.2 GROUND SNOW LOADS, Pg, FOR THE UNITED STATES |
423 | FIGURE 1608.2—continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES |
424 | FIGURE 1609(A) STATE OF RHODE ISLAND WIND-BORNE DEBRIS COASTAL REGION OFFSET |
425 | FIGURE 1609(B) FROST PROTECTION |
426 | EQUATION 16-34 |
427 | EQUATION 16-35 |
428 | TABLE 1609.6.2 NET PRESSURE COEFFICIENTS, Cneta, b |
429 | TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cneta, b |
430 | TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cneta, b |
431 | TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cnet a, b SECTION 1610 SOIL LATERAL LOADS SECTION 1611 RAIN LOADS EQUATION 16-36 |
432 | TABLE 1610.1 LATERAL SOIL LOAD |
433 | [P] FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
434 | SECTION 1612 FLOOD LOADS |
435 | SECTION 1613 EARTHQUAKE LOADS EQUATION 16-37 EQUATION 16-38 EQUATION 16-39 EQUATION 16-40 |
436 | TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT Fa a TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT FV a |
437 | TABLE 1613.3.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION SECTION 1614 ATMOSPHERIC ICE LOADS SECTION 1615 STRUCTURAL INTEGRITY |
438 | EQUATION 16-41 EQUATION 16-42 |
439 | FIGURE 1615.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES |
440 | CHAPTER 17 SPECIAL INSPECTIONS AND TESTS SECTION 1701 GENERAL SECTION 1702 DEFINITIONS SECTION 1703 APPROVALS |
441 | SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION |
443 | SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS |
444 | TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS |
445 | TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION |
446 | TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS |
447 | TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS |
451 | SECTION 1706 DESIGN STRENGTHS OF MATERIALS SECTION 1707 ALTERNATIVE TEST PROCEDURE SECTION 1708 IN-SITU LOAD TESTS |
452 | SECTION 1709 PRECONSTRUCTION LOAD TESTS |
454 | CHAPTER 18 SOILS AND FOUNDATIONS SECTION 1801 GENERAL SECTION 1802 DEFINITIONS SECTION 1803 GEOTECHNICAL INVESTIGATIONS |
456 | SECTION 1804 EXCAVATION, GRADING AND FILL |
457 | SECTION 1805 DAMPPROOFING AND WATERPROOFING |
459 | SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES |
460 | TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLS |
461 | TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS |
462 | TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHES |
463 | TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES |
464 | TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES |
465 | EQUATION 18-1 EQUATION 18-2 EQUATION 18-3 SECTION 1808 FOUNDATIONS |
466 | FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES |
467 | TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ʹ C OF CONCRETE OR GROUT |
468 | TABLE 1808.8.2 MINIMUM CONCRETE COVER SECTION 1809 SHALLOW FOUNDATIONS |
469 | TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION |
470 | SECTION 1810 DEEP FOUNDATIONS |
472 | TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS |
474 | EQUATION 18-4 |
476 | EQUATION 18-5 EQUATION 18-6 EQUATION 18-7 EQUATION 18-8 |
477 | EQUATION 18-9 EQUATION 18-10 EQUATION 18-11 |
484 | CHAPTER 19 CONCRETE SECTION 1901 GENERAL SECTION 1902 DEFINITIONS SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS SECTION 1904 DURABILITY REQUIREMENTS |
485 | SECTION 1905 MODIFICATIONS TO ACI 318 |
487 | SECTION 1906 STRUCTURAL PLAIN CONCRETE SECTION 1907 MINIMUM SLAB PROVISIONS |
488 | SECTION 1908 SHOTCRETE |
490 | CHAPTER 20 ALUMINUM SECTION 2001 GENERAL SECTION 2002 MATERIALS |
492 | CHAPTER 21 MASONRY SECTION 2101 GENERAL SECTION 2102 DEFINITIONS AND NOTATIONS |
493 | SECTION 2103 MASONRY CONSTRUCTION MATERIALS TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS |
494 | SECTION 2104 CONSTRUCTION SECTION 2105 QUALITY ASSURANCE SECTION 2106 SEISMIC DESIGN SECTION 2107 ALLOWABLE STRESS DESIGN EQUATION 21-1 SECTION 2108 STRENGTH DESIGN OF MASONRY |
495 | SECTION 2109 EMPIRICAL DESIGN OF MASONRY TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS EQUATION 21-2 |
496 | TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY |
497 | SECTION 2110 GLASS UNIT MASONRY SECTION 2111 MASONRY FIREPLACES |
499 | FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION SECTION 2112 MASONRY HEATERS |
500 | SECTION 2113 MASONRY CHIMNEYS |
503 | FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS |
504 | TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZES TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION |
506 | CHAPTER 22 STEEL SECTION 2201 GENERAL SECTION 2202 DEFINITIONS SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES SECTION 2204 CONNECTIONS SECTION 2205 STRUCTURAL STEEL |
507 | SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES SECTION 2207 STEEL JOISTS |
508 | SECTION 2208 STEEL CABLE STRUCTURES SECTION 2209 STEEL STORAGE RACKS SECTION 2210 COLD-FORMED STEEL SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION |
510 | CHAPTER 23 WOOD SECTION 2301 GENERAL SECTION 2302 DEFINITIONS SECTION 2303 MINIMUM STANDARDS AND QUALITY |
514 | SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS |
515 | TABLE 2304.6.1 MAXIMUM NOMINAL DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES |
516 | TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS |
517 | TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a, b (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports) TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)a, b |
520 | TABLE 2304.10.1 FASTENING SCHEDULE |
521 | TABLE 2304.10.1—continued FASTENING SCHEDULE |
522 | TABLE 2304.10.1—continued FASTENING SCHEDULE |
523 | TABLE 2304.10.1—continued FASTENING SCHEDULE |
524 | TABLE 2304.10.1—continued FASTENING SCHEDULE |
525 | SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS EQUATION 23-1 |
526 | TABLE 2305.2(1)en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c EQUATION 23-2 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS |
527 | SECTION 2306 ALLOWABLE STRESS DESIGN |
528 | TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION TABLE 2308.2.1 ALLOWABLE STORY HEIGHT |
529 | TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf |
530 | TABLE 2306.2(1)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf |
531 | TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING |
532 | TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING |
533 | TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY |
534 | TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES |
536 | TABLE 2308.4.1.1 (1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and required number of jack studs) |
537 | TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and required number of jack studs) TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS (Maximum spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and required number of jack studs) |
538 | TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360) |
539 | TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360) |
540 | TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360) |
541 | TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360) |
542 | FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS |
543 | FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY |
544 | TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS |
545 | TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING |
546 | FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM |
547 | TABLE 2308.6.1a WALL BRACING REQUIREMENTS |
548 | TABLE 2308.6.3(1) BRACING METHODS |
549 | TABLE 2308.6.3(1)—continued BRACING METHODS TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING |
550 | TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHING (Not Exposed to the Weather, Strength Axis Parallel or Perpendicular to Studs Except as Indicated Below) TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (Not Exposed to the Weather, Long Dimension of the Panel Parallel or Perpendicular to Studs) TABLE 2308.6.3(5) HARDBOARD SIDING |
551 | FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW) |
552 | FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH) |
553 | FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION |
554 | FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION |
555 | FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE |
556 | FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS |
558 | TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds) |
559 | TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 psf, L/Δ = 240) |
560 | TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 psf, L/Δ = 240) |
561 | TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 psf, L/Δ = 240) |
562 | TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 psf, L/Δ = 240) |
563 | TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Not Attached to Rafters, L/Δ = 180) |
564 | TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Not Attached to Rafters, L/Δ = 180) |
565 | TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Attached to Rafters, L/Δ = 240) |
566 | TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Attached to Rafters, L/Δ = 240) |
567 | TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Not Attached to Rafters, L/Δ = 180) |
568 | TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Not Attached to Rafters, L/Δ = 180) |
569 | TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Not Attached to Rafters, L/Δ = 180) |
570 | TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Not Attached to Rafters, L/Δ = 180) |
571 | TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Attached to Rafters, L/Δ = 240) |
572 | TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Attached to Rafters, L/Δ = 240) |
573 | TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Attached to Rafters, L/Δ = 240) |
574 | TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Attached to Rafters, L/Δ = 240) |
575 | TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSg |
576 | TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL |
577 | TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING SECTION 2310 NATIVE LUMBER |
578 | TABLE 2310 NATIVE LUMBER ALLOWABLE STRESS |
580 | CHAPTER 24 GLASS AND GLAZING SECTION 2401 GENERAL SECTION 2402 DEFINITIONS SECTION 2403 GENERAL REQUIREMENTS FOR GLASS SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS EQUATION 24-1 EQUATION 24-2 EQUATION 24-3 |
581 | EQUATION 24-4 EQUATION 24-5 EQUATION 24-6 EQUATION 24-7 EQUATION 24-8 EQUATION 24-9 EQUATION 24-10 EQUATION 24-11 EQUATION 24-12 |
582 | SECTION 2405 SLOPED GLAZING AND SKYLIGHTS |
583 | EQUATION 24-13 EQUATION 24-14 EQUATION 24-15 SECTION 2406 SAFETY GLAZING |
584 | TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201 TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1 |
585 | SECTION 2407 GLASS IN HANDRAILS AND GUARDS SECTION 2408 GLAZING IN ATHLETIC FACILITIES |
586 | SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS |
588 | CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER SECTION 2501 GENERAL SECTION 2502 DEFINITIONS SECTION 2503 INSPECTION SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES SECTION 2505 SHEAR WALL CONSTRUCTION SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS |
589 | TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES SECTION 2507 LATHING AND PLASTERING TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES |
590 | SECTION 2508 GYPSUM CONSTRUCTION TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES |
591 | SECTION 2509 SHOWERS AND WATER CLOSETS TABLE 2509.2 BACKERBOARD MATERIALS SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO) |
592 | SECTION 2511 INTERIOR PLASTER TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION SECTION 2512 EXTERIOR PLASTER |
593 | TABLE 2512.6 CEMENT PLASTERS SECTION 2513 EXPOSED AGGREGATE PLASTER SECTION 2514 REINFORCED GYPSUM CONCRETE |
594 | CHAPTER 26 PLASTIC SECTION 2601 GENERAL SECTION 2602 DEFINITIONS SECTION 2603 FOAM PLASTIC INSULATION |
598 | FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP SECTION 2604 INTERIOR FINISH AND TRIM |
599 | TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT |
600 | SECTION 2605 PLASTIC VENEER SECTION 2606 LIGHT-TRANSMITTING PLASTICS |
601 | SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS |
602 | TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS |
603 | TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING |
604 | SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS SECTION 2612 PLASTIC COMPOSITES SECTION 2613 FIBER-REINFORCED POLYMER |
605 | SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION |
606 | CHAPTER 27 ELECTRICAL SECTION 2701 GENERAL SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS |
608 | CHAPTER 28 MECHANICAL SYSTEMS SECTION 2801 GENERAL |
610 | CHAPTER 29 PLUMBING SYSTEMS SECTION 2901 GENERAL SECTION 2902 MINIMUM PLUMBING FACILITIES [P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2) |
611 | [P] TABLE 2902.1—(continued) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2) |
612 | [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2) |
614 | CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS SECTION 3001 GENERAL SECTION 3002 HOISTWAY ENCLOSURES |
615 | SECTION 3003 EMERGENCY OPERATIONS SECTION 3004 CONVEYING SYSTEMS SECTION 3005 MACHINE ROOMS |
616 | SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION |
617 | SECTION 3007 FIRE SERVICE ACCESS ELEVATOR |
618 | FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL SECTION 3008 OCCUPANT EVACUATION ELEVATORS |
622 | CHAPTER 31 SPECIAL CONSTRUCTION SECTION 3101 GENERAL SECTION 3102 MEMBRANE STRUCTURES |
623 | SECTION 3103 TEMPORARY STRUCTURES SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS |
625 | SECTION 3105 AWNINGS AND CANOPIES SECTION 3106 MARQUEES SECTION 3107 SIGNS SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS |
626 | SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS SECTION 3110 AUTOMATIC VEHICULAR GATES SECTION 3111 PHOTOVOLTAIC PANELS AND MODULES SECTION 3112 FABRIC STRUCTURES |
628 | CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY SECTION 3201 GENERAL SECTION 3202 ENCROACHMENTS |
630 | CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION SECTION 3301 GENERAL SECTION 3302 CONSTRUCTION SAFEGUARDS SECTION 3303 DEMOLITION SECTION 3304 SITE WORK |
631 | SECTION 3305 SANITARY SECTION 3306 PROTECTION OF PEDESTRIANS TABLE 3306.1 PROTECTION OF PEDESTRIANS |
632 | SECTION 3307 PROTECTION OF ADJOINING PROPERTY SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY SECTION 3309 FIRE EXTINGUISHERS SECTION 3310 MEANS OF EGRESS |
633 | SECTION 3311 STANDPIPES SECTION 3312 AUTOMATIC SPRINKLER SYSTEM SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION |
634 | CHAPTER 34 EXISTING STRUCTURES SECTION 3401 GENERAL SECTION 3402 DEFINITIONS SECTION 3403 ADDITIONS |
635 | SECTION 3404 ALTERATIONS |
636 | SECTION 3405 REPAIRS |
637 | SECTION 3406 FIRE ESCAPES SECTION 3407 GLASS REPLACEMENT SECTION 3408 CHANGE OF OCCUPANCY |
638 | SECTION 3409 HISTORIC BUILDINGS SECTION 3410 MOVED STRUCTURES SECTION 3411 ACCESSIBILITY FOR EXISTING BUILDINGS |
639 | TABLE 3411.8.5 RAMPS |
640 | SECTION 3412 COMPLIANCE ALTERNATIVES |
641 | EQUATION 34-1 EQUATION 34-2 |
642 | EQUAITON 34-3 EQUATION 34-4 TABLE 3412.6.3 COMPARTMENTATION VALUES TABLE 3412.6.4 SEPARATION VALUES |
643 | TABLE 3412.6.5 CORRIDOR WALL VALUES TABLE 3412.6.6(1) VERTICAL OPENING PROTECTION VALUE TABLE 3412.6(2) CONSTRUCTION-TYPE FACTOR EQUATION 34-5 |
644 | TABLE 3412.6.8 AUTOMATIC FIRE DETECTION VALUES TABLE 3412.6.9 FIRE ALARM SYSTEM VALUES TABLE 3412.6.10 SMOKE CONTROL VALUES |
645 | TABLE 3412.6.11 MEANS OF EGRESS VALUES TABLE 3412.6.12 DEAD-END VALUES EQUATION 34-6 |
646 | TABLE 3412.6.14 ELEVATOR CONTROL VALUES TABLE 3412.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES TABLE 3412.6.16 MIXED OCCUPANCY VALUESa TABLE 3412.6.17 SPRINKLER SYSTEM VALUES |
647 | TABLE 3412.6.18 STANDPIPE SYSTEM VALUES TABLE 3412.6.19 INCIDENTAL USE AREA VALUESa |
648 | TABLE 3412.7 SUMMARY SHEET—BUILDING CODE |
649 | TABLE 3412.8 MANDATORY SAFETY SCORESa TABLE 3412.9 EVALUATION FORMULASa |
650 | CHAPTER 35 REFERENCED STANDARDS AA AAMA ACI |
651 | AISC AISI ALI |
652 | AMCA ANSI APA |
653 | ASABE ASCE/SEI |
654 | ASME ASSE ASTM |
660 | AWC |
661 | AWCI AWPA AWS BHMA CEN |
662 | CGSB CPA CPSC CSA |
663 | CSSB DASMA DOC DOL |
664 | DOTn FEMA FM GA |
665 | HPVA ICC |
666 | ISO MHI NAAMM NCMA NFPA |
668 | PCI PTI RMI |
669 | SBCA SDI SJI SPRI TIA |
670 | TMS TPI UL |
671 | ULC |
672 | USC WCLIB WDMA WRI |
674 | APPENDIX A EMPLOYEE QUALIFICATIONS |
676 | APPENDIX B BOARD OF APPEALS |
678 | APPENDIX C GROUP U—AGRICULTURAL BUILDINGS SECTION C101 GENERAL SECTION C102 ALLOWABLE HEIGHT AND AREA TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY SECTION C103 MIXED OCCUPANCIES SECTION C104 EXITS |
680 | APPENDIX D FIRE DISTRICTS |
682 | APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS SECTION E101 GENERAL SECTION E102 DEFINITIONS SECTION E103 ACCESSIBLE ROUTE SECTION E104 SPECIAL OCCUPANCIES TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES |
683 | SECTION E105 OTHER FEATURES AND FACILITIES SECTION E106 TELEPHONES TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES |
684 | SECTION E107 SIGNAGE SECTION E108 BUS STOPS |
685 | SECTION E109 TRANSPORTATION FACILITIES AND STATIONS SECTION E110 AIRPORTS |
686 | SECTION E111 REFERENCED STANDARDS |
688 | APPENDIX F RODENTPROOFING SECTION F101 GENERAL |
690 | APPENDIX G FLOOD-RESISTANT CONSTRUCTION SECTION G101 ADMINISTRATION SECTION G102 APPLICABILITY SECTION G103 POWERS AND DUTIES |
691 | SECTION G104 PERMITS |
692 | SECTION G105 VARIANCES |
693 | SECTION G201 DEFINITIONS SECTION G301 SUBDIVISIONS SECTION G401 SITE IMPROVEMENT |
694 | SECTION G501 MANUFACTURED HOMES SECTION G601 RECREATIONAL VEHICLES SECTION G701 TANKS SECTION G801 OTHER BUILDING WORK |
695 | SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U SECTION G1101 REFERENCED STANDARDS |
696 | APPENDIX H SIGNS SECTION H101 GENERAL SECTION H102 DEFINITIONS SECTION H103 LOCATION SECTION H104 IDENTIFICATION |
697 | SECTION H105 DESIGN AND CONSTRUCTION SECTION H106 ELECTRICAL SECTION H107 COMBUSTIBLE MATERIALS SECTION H108 ANIMATED DEVICES SECTION H109 GROUND SIGNS |
698 | SECTION H110 ROOF SIGNS SECTION H111 WALL SIGNS SECTION H112 PROJECTING SIGNS |
699 | SECTION H113 MARQUEE SIGNS SECTION H114 PORTABLE SIGNS TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS TABLE 4-B THICKNESS OF PROJECTION SIGN SECTION H115 REFERENCED STANDARDS |
700 | APPENDIX I PATIO COVERS SECTION I101 GENERAL SECTION I102 DEFINITION SECTION I103 EXTERIOR WALLS AND OPENINGS SECTION I104 HEIGHT SECTION I105 STRUCTURAL PROVISIONS |
702 | APPENDIX J GRADING |
704 | APPENDIX K ADMINISTRATIVE PROVISIONS |
706 | APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION SECTION L101 GENERAL |
708 | APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD SECTION M101 TSUNAMI-GENERATED FLOOD HAZARD SECTION M102 REFERENCED STANDARDS |
710 | INDEX |
748 | ICC EVALUATION SERVICE |
749 | ICC MEMBERSHIP |
750 | ICC ASSESSMENT CENTER |
751 | ICC premiumACCESS |