Shopping Cart

No products in the cart.

RI EnergyCode 2019 1stptg

$28.44

Rhode Island Energy Conservation Code, 1st Printing

Published By Publication Date Number of Pages
RI 2019 193
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2015 IECC.

PDF Catalog

PDF Pages PDF Title
1 2019 RHODE ISLAND ENERGY CONSERVATION CODE
2 2019 RHODE ISLAND ENERGY CONSERVATION CODE BASED ON THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE
12 LEGISLATION
14 RHODE ISLAND STATE BUILDING CODE SBC-8 STATE ENERGY CONSERVATION CODE
15 REGULATION SBC-8 STATE ENERGY CONSERVATION CODE AUGUST 1, 2019
16 STATE OF RHODE ISLAND BUILDING CODE STANDARDS COMMITTEE
17 STATE BUILDING CODE REGULATIONS – 2019
18 TABLE OF CONTENTS
20 CHAPTER 23–27.3 STATE BUILDING CODE
§ 23-27.3-100.0 SCOPE
23-27.3-100.1 SHORT TITLE – APPLICABILITY
§ 23-27.3-100.1.1 CHAPTER TITLE – APPLICABILITY
§ 23-27.3-100.1.2 PURPOSE
§ 23-27.3-100.1.3 CREATION OF THE STATE BUILDING CODE STANDARDS COMMITTEE
21 § 23-27.3-100.1.4 APPOINTMENT AND QUALIFICATIONS OF THE COMMITTEE
§ 23-27.3-100.1.5 BUILDING CODE – ADOPTION AND PROMULGATION BY COMMITTEE
22 § 23-27.3-100.1.5.1 HOUSING AND MAINTENANCE CODE
§ 23-27.3-100.1.5.2 EXISTING CODES
§ 23-27.3-100.1.5.3 STATE REHABILITATION BUILDING AND FIRE CODE FOR EXISTING BUILDINGS AND STRUCTURES
§ 23-27.3-100.1.5.4 STATE ENERGY CONSERVATION CODE
23 § 23-27.3-100.1.5.5 HURRICANE, STORM AND FLOOD STANDARDS
§ 23-27.3-100.1.6 COMMITTEE AS BOARD OF STANDARDS AND APPEALS – POWERS AND DUTIES – APPEALS
§ 23-27.3-100.1.7 EFFECT OF LOCAL CODES – REPEAL OF LOCAL AUTHORITY
§ 23-27.3-100.1.8 SEVERABILITY
§ 23-27.3-100.2 APPLICATION OF REFERENCES
§ 23-27.3-100.3 CONSTRUCTION
§ 23-27.3-100.4 SPECIALIZED CODES INCORPORATED
24 § 23-27.3-101.0 MATTERS COVERED
§ 23-27.3-101.1 EXEMPTION FOR ORDINARY REPAIRS
§ 23-27.3-101.2 MATTERS NOT COVERED
§ 23-27.3-101.2.1 PROPOSED BUILDINGS
§ 23-27.3-101.2.2 BUILDINGS AND STRUCTURES, EXISTING AND UNDER CONSTRUCTION
§ 23-27.3-101.3 ZONING RESTRICTIONS
23-27.3-102.0 ORDINARY REPAIRS
§ 23-27.3-103.0 INSTALLATION OF SERVICE EQUIPMENT
§ 23-27.3-104.0 MAINTENANCE
25 § 23-27.3-104.1 OWNER RESPONSIBILITY
§ 23-27.3-105.0 CHANGE IN EXISTING USE
§ 23-27.3-105.1 CONTINUATION OF EXISTING USE
§ 23-27.3-105.2 CHANGE IN USE AND OCCUPANCY
§ 23-27.3-105.3 PART CHANGE IN USE
§ 23-27.3-105.4 REESTABLISHMENT OF A PRIOR USE
§ 23-27.3-106.0 EXISTING STRUCTURES
§ 23-27.3-106.1 SUBSTANTIAL IMPROVEMENTS
§ 23-27.3-106.2 SUBSTANTIAL DAMAGES EXCEEDING FIFTY PERCENT
26 § 23-27.3-106.3 IMPROVEMENTS AND DAMAGES BETWEEN TWENTY-FIVE AND FIFTY PERCENT OF VALUE
§ 23-27.3-106.4 IMPROVEMENTS OR DAMAGES UNDER TWENTY-FIVE PERCENT OF VALUE
§ 23-27.3-106.5 PHYSICAL VALUE
§ 23-27.3-107.0 DEPARTMENT OF BUILDING INSPECTION
§ 23-27.3-107.1 LOCAL BUILDING OFFICIAL – APPOINTMENT
§ 23-27.3-107.1.1 LOCAL INSPECTOR
§ 23-27.3-107.2 ALTERNATE LOCAL BUILDING OFFICIAL
27 § 23-27.3-107.3 APPOINTMENT OF PERSONNEL BY STATE BUILDING COMMISSIONER
§ 23-27.3-107.4 QUALIFICATIONS AND DUTIES OF THE STATE BUILDING COMMISSIONER
§ 23-27.3-107.5 LOCAL BUILDING OFFICIAL – QUALIFICATIONS – POWERS AND DUTIES
§ 23-27.3-107.6 CERTIFICATION OF LOCAL BUILDING OFFICIALS – EDUCATIONAL PROGRAMS
28 § 23-27.3-107.7 RECERTIFICATION AND CONTINUING EDUCATION
§ 23-27.3-107.8 RESTRICTION ON EMPLOYEES’ ACTIVITIES
§ 23-27.3-107.9 RELIEF FROM PERSONAL RESPONSIBILITY
§ 23-27.3-108.0 DUTIES AND POWERS OF THE BUILDING OFFICIAL AND THE STATE BUILDING COMMISSIONER
§ 23-27.3-108.1 LOCAL BUILDING OFFICIAL – ENFORCEMENT DUTIES
§ 23-27.3-108.1.1 APPLICATIONS AND PERMITS
§ 23-27.3-108.1.3 NEW MATERIALS AND METHODS OF CONSTRUCTION
29 § 23-27.3-108.1.3.1 TEST RESULTS
§ 23-27.3-108.1.3.2 RETESTING
§ 23-27.3-108.1.4 INSPECTIONS
§ 23-27.3-108.1.5 REPEALED
§ 23-27.3-108.1.6 ADMINISTRATIVE PROCEDURES
§ 23-27.3-108.1.7 DEPARTMENT RECORDS
§ 23-27.3-108.1.8 REPORTS
§ 23-27.3-108.2 STATE BUILDING COMMISSIONER’S DUTIES
30 § 23-27.3-108.2.0.1 REPEALED
§ 23-27.3-108.2.1 DUTIES OF COMMITTEE
§ 23-27.3-108.2.2 COMPENSATION OF COMMITTEE MEMBERS
§ 23-27.3-108.2.3 EMERGENCY PROCEDURES
§ 23-27.3-108.2.4 MUNICIPAL ADVISORY COUNCIL ON STATEWIDE PERMITTING
§ 23-27.3-109.0 COMMITTEE
§ 23-27.3-109.1 COMMITTEE’S RULE MAKING AUTHORITY – LEGISLATIVE REPORT – LEGISLATIVE COMMITTEE
31 § 23-27.3-109.1.1 COMMITTEE – LICENSING OF LABORATORIES AND TEST PERSONNEL
§ 23-27.3-109.1.2 COMMITTEE – REGULATION OF MANUFACTURED BUILDINGS
§ 23-27.3-109.1.3 ADOPTION OF FEDERAL STANDARDS FOR MANUFACTURED HOMES
§ 23-27.3-109.1.3.1 INSPECTION OF MANUFACTURED HOMES MANUFACTURERS
§ 23-27.3-109.1.3.2 PENALTIES FOR VIOLATION AS TO MANUFACTURED HOMES
32 § 23-27.3-109.1.3.3 MONITORING INSPECTION FEE
§ 23-27.3-109.1.3.4 REPORTS OF MANUFACTURED HOME MANUFACTURERS, DISTRIBUTORS, AND DEALERS
§ 23-27.3-109.1.3.5 TEMPORARY GREENHOUSE DEFINED
§ 23-27.3-109.1.4 REPEALED
§ 23-27.3-109.2 ACCEPTED ENGINEERING PRACTICE
§ 23-27.3-109.3 PROPOSING AMENDMENTS TO RULES AND REGULATIONS
§ 23-27.3-110.0 MODIFICATIONS AND VARIANCES
§ 23-27.3-111.0 NEW AND ALTERED BUILDING AND STRUCTURE – INSPECTIONS
§ 23-27.3-111.1 PRELIMINARY INSPECTION
§ 23-27.3-111.2 INSPECTION
33 § 23-27.3-111.3 MANUFACTURING BUILDINGS
§ 23-27.3-111.3.1 PLANT INSPECTION
§ 23-27.3-111.3.2 INSTALLATION SITE INSPECTION
§ 23-27.3-111.4 EXISTING BUILDINGS
§ 23-27.3-111.4.1 PERIODIC INSPECTIONS
§ 23-27.3-111.4.2 REPEALED
§ 23-27.3-111.5 FINAL INSPECTION
§ 23-27.3-111.6 INSPECTION SERVICES
§ 23-27.3-111.7 COORDINATION OF INSPECTIONS
§ 23-27.3-112.0 RIGHT OF ENTRY
§ 23-27.3-112.1 OFFICIAL IDENTIFICATION CARD
34 § 23-27.3-112.2 MUNICIPAL COOPERATION
§ 23-27.3-113.0 APPLICATION FOR PERMIT
§ 23-27.3-113.1 WHEN PERMIT IS REQUIRED
§ 23-27.3-113.1.1 ISSUANCE OF PERMITS FOR SIDING
§ 23-27.3-113.2 FORM OF APPLICATION
§ 23-27.3-113.3 BY WHOM APPLICATION IS MADE
§ 23-27.3-113.3.1 APPLICATIONS FOR WORK REQUIRING LICENSED WORKERS
§ 23-27.3-113.3.2 APPLICATIONS FOR WORK REQUIRING REGISTERED WORKERS
35 § 23-27.3-113.4 DESCRIPTION OF WORK
§ 23-27.3-113.5 PLANS AND SPECIFICATIONS
§ 23-27.3-113.5.1 REPEALED
§ 23-27.3-113.6 PLOT PLAN
§ 23-27.3-113.6.1 APPROVAL OF AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM
§ 23-27.3-113.7 ENGINEERING DETAILS
§ 23-27.3-113.8 AMENDMENTS TO APPLICATION
§ 23-27.3-113.9 TIME LIMITATION ON APPLICATION
§ 23-27.3-114.0 PERMITS
§ 23-27.3-114.1 ACTION ON APPLICATION
36 § 23-27.3-114.1.1 REPORTS TO ASSESSORS
§ 23-27.3-114.2 EXPIRATION OF PERMIT
§ 23-27.3-114.3 PREVIOUS APPROVALS
37 § 23-27.3-114.3.1 DRAWINGS AND SPECIFICATIONS
§ 23-27.3-114.4 BUILDING OFFICIAL TO SIGN PERMIT
§ 23-27.3-114.5 APPROVED PLANS
§ 23-27.3-114.6 REVOCATION OF PERMITS
§ 23-27.3-114.7 APPROVAL IN PART
23-27.3-114.8 POSTING OF PERMIT
§ 23-27.3-114.9 NOTICE OF BUILDING START
§ 23-27.3-115.0 CONDITIONS OF PERMIT
§ 23-27.3-115.1 COMPLIANCE WITH CODE
§ 23-27.3-115.2 COMPLIANCE WITH PERMIT
23-27.3-115.3 COMPLIANCE WITH PLOT PLAN
§ 23-27.3-115.4 CHANGE IN PLOT PLAN
38 § 23-27.3-115.5 DISMISSAL OF CONTRACTOR OR SUBCONTRACTOR
§ 23-27.3-116.0 MOVING, RAISING, SHORING OR DEMOLITION OF BUILDINGS
§ 23-27.3-116.1 SERVICE CONNECTIONS
§ 23-27.3-116.2 BUILDINGS TO BE RODENT-ERADICATED PRIOR TO DEMOLITION
§ 23-27.3-116.3 DESCRIPTION AND INSPECTION OF BUILDINGS – TRAVEL ROUTE
§ 23-27.3-116.4 AGREEMENT CONDITION TO MOVING
§ 23-27.3-116.5 PUBLIC UTILITIES, WIRES, POLES, TREES, AND SHRUBS
§ 23-27.3-116.6 MOVING TO BE CONTINUOUS
§ 23-27.3-116.7 WATCHPERSON AND LIGHTS DURING MOVING
39 § 23-27.3-116.8 BONDS AND LIABILITY INSURANCE
§ 23-27.3-116.9 SHORING
§ 23-27.3-117.0 REMOVAL OF STRUCTURES
§ 23-27.3-117.1 LOT REGULATION
§ 23-27.3-118.0 FEES
§ 23-27.3-118.1 SPECIAL FEES
§ 23-27.3-118.2 RAMPS FOR DISABLED PERSONS
§ 23-27.3-119.0 FEE COMPUTATION
§ 23-27.3-120.0 CERTIFICATE OF USE AND OCCUPANCY
§ 23-27.3-120.1 NEW BUILDINGS
23-27.3-120.2 BUILDINGS HEREAFTER ALTERED
40 § 23-27.3-120.3 EXISTING BUILDINGS
§ 23-27.3-120.4 CHANGES IN USE AND OCCUPANCY
§ 23-27.3-120.5 TEMPORARY OCCUPANCY
§ 23-27.3-120.6 CONTENTS OF CERTIFICATE
§ 23-27.3-121.0 POSTING BUILDINGS
§ 23-27.3-121.1 POSTED USE AND OCCUPANCY
41 § 23-27.3-121.2 POSTED OCCUPANCY LOAD
§ 23-27.3-121.3 FURNISHING OF POSTED SIGNS
§ 23-27.3-121.4 PERIODIC INSPECTION FOR POSTING
§ 23-27.3-122.0 VIOLATIONS
§ 23-27.3-122.1 NOTICE OF VIOLATION
§ 23-27.3-122.1.2 NOTICE OR ORDERS – SERVICES AND CONTENT
§ 23-27.3-122.2 PROSECUTION OF VIOLATION
§ 23-27.3-122.3 PENALTIES
§ 23-27.3-122.4 ABATEMENT OF VIOLATIONS
42 § 23-27.3-123.0 STOP-WORK ORDER
§ 23-27.3-123.1 NOTICE TO OWNER
§ 23-27.3-123.1.1 POSTING OF ORDER
§ 23-27.3-123.2 UNLAWFUL CONTINUANCE
§ 23-27.3-124.0 UNSAFE STRUCTURES – GENERAL PROVISIONS
§ 23-27.3-124.1 UNSAFE CONDITIONS
§ 23-27.3-124.2 NOTICE OF UNSAFE CONDITION
43 § 23-27.3-124.3 APPEALS
§ 23-27.3-124.4 RESTORATION OF UNSAFE BUILDINGS
§ 23-27.3-124.4.1 COMPLIANCE
§ 23-27.3-124.5 DISREGARD OF UNSAFE NOTICE
§ 23-27.3-124.6 BOARDING
44 § 23-27.3-124.6.1 DISCONNECTION OF UTILITIES
23-27.3-124.6.2 REMOVAL OF DEBRIS AND RUBBISH
§ 23-27.3-125.0 EMERGENCY MEASURES
§ 23-27.3-125.1 VACATING BUILDINGS
§ 23-27.3-125.2 TEMPORARY SAFEGUARDS
§ 23-27.3-125.3 CLOSING STREETS
§ 23-27.3-125.4 EMERGENCY REPAIRS
§ 23-27.3-125.5 HAZARDOUS BUILDINGS
§ 23-27.3-125.6 COSTS OF EMERGENCY REPAIRS
§ 23-27.3-125.7 LIEN FOR EMERGENCY REPAIRS
§ 23-27.3-126.0 APPEALS FROM ORDERS IN REGARD TO UNSAFE BUILDINGS
45 § 23-27.3-126.1 APPLICATION FOR REVIEW
§ 23-27.3-126.2 PROCEDURE
§ 23-27.3-126.3 FINDINGS
§ 23-27.3-127.0 STATE AND LOCAL BOARDS OF APPEALS
§ 23-27.3-127.1 COMMITTEE TO SERVE AS A BOARD OF STANDARDS AND APPEALS
46 § 23-27.3-127.1.1 STAY OF PROCEEDINGS
§ 23-27.3-127.1.2 GRANTING VARIANCE
§ 23-27.3-127.1.3 ADDITIONAL POWERS
§ 23-27.3-127.1.4 PROCEDURES – RECORD OF VARIANCES
47 § 23-27.3-127.2 LOCAL BOARD OF APPEALS
§ 23-27.3-127.2.1 MEMBERSHIP AND LOCAL BOARD
§ 23-27.3-127.2.2 STAY OF PROCEEDINGS
§ 23-27.3-127.2.3 GRANTING VARIANCE
§ 23-27.3-127.2.4 ADDITIONAL POWERS
§ 23-27.3-127.2.5 PROCEDURES
48 § 23-27.3-127.2.6 LOCAL DECISION TRANSMITTED TO STATE BOARD
§ 23-27.3-128.0 DESIGN AND CONSTRUCTION PROCEDURES
§ 23-27.3-128.1 SCOPE
§ 23-27.3-128.1.1 OWNER’S RESPONSIBILIES
§ 23-27.3-128.1.2 – 23-27.3-128.1.5 REPEALED
§ 23-27.3-128.2 REPEALED
§ 23-27.3-128.2.1 DRAWINGS AND SPECIFICATIONS
§ 23-27.3-128.2.2 RESPONSIBILITIES
49 § 23-27.3-128.2.3 REPORTING
§ 23-27.3-128.3 CONSTRUCTION CONTRACTOR RESPONSIBILITIES
§ 23-27.3-128.4 TESTING REQUIRED
§ 23-27.3-128.5 BUILDING OFFICIAL’S RESPONSIBILITIES
§ 23-27.3-128.5.1 WAIVER OF PLAN EXAMINATION
§ 23-27.3-128.5.2 WAIVER OF DETAILED FIELD INSPECTION
50 § 23-27.3-128.5.3 INSPECTION WAIVER – UTILIZATION
§ 23-27.3-128.5.4 BUILDING PERMIT ISSUANCE OR REQUIREMENTS
§ 23-27.3-128.6 SPECIAL TECHNICAL SERVICES
§ 23-27.3-128.7 FEES AND COSTS
§ 23-27.3-129.0, 23-27.3-129.1 REPEALED
§ 23-27.3-129.2 REPEALED
§ 23-27.3-129.3 REPEALED
§ 23-27.3-200.0 SAVINGS CLAUSE
§ 23-27.3-300.0 PUBLICATION OF CODE
§ 23-27.3-400.0 SEVERABILITY
51 23-27.3-401.0 SALE OF PRESSURE VESSEL
§ 23-27.3-500.0 EFFECTIVE DATE OF CODE
§ 23-27.3-501.0, 23-27.3-502.0 REPEALED
§ 23-27.3-503.0, 23-27.3-504.0 [OBSOLETE]
§ 23-27.3-505.0 REPEALED
§ 23-27.3-506.0 [OBSOLETE]
§ 23-27.3-600.0 FRESH WATER WETLANDS
§ 23-27.3-700.0 REPEALED
§ 23-27.3-701.0 BABY CHANGING TABLES
52 IECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
54 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
55 SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS
56 SECTION C104 INSPECTIONS
SECTION C105 VALIDITY
SECTION C106 REFERENCED STANDARDS
57 SECTION C107 FEES
SECTION C108 STOP WORK ORDER
SECTION C109 BOARD OF APPEALS
58 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
64 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
TABLE C301.1 CLIMATE ZONE VALUES
TABLE C301.3(2) RHODE ISLAND CLIMATE ZONE DEFINITION
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
65 FIGURE C301.1 CLIMATE ZONES
66 TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
68 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
69 TABLE C402.1.3 OPAQUE THERMAL ENVELOPE ASSEMBLY REQUIREMENTS
EQUATION 4-1
TABLE C402.1.4 OPAQUE THERMAL ENVELOPE REQUIREMENTS
TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
70 EQUATION 4-2
71 EQUATION 4-3
72 TABLE C402.4 BUILDING ENVELOPE REQUIREMENT FENESTRATION
EQUATION 4-4
73 EQUATION 4-5
74 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
75 SECTION C403 BUILDING MECHANICAL SYSTEMS
76 EQUATION 4-6
EQUATION 4-7
77 TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
78 TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
79 TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
80 TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
81 TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
82 TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE 403.2.3(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
83 TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
84 TABLE C403.2.3(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTSa, b, d
85 TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
86 TABLE C403.2.3(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.2.3(10) HEAT TRANSFER EQUIPMENT
89 TABLE C403.2.7 ENERGY RECOVERY REQUIREMENT
TABLE C403.2.8 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
90 EQUATION 4-8
91 TABLE C403.2.10 MINIMUM PIPE INSULATION THICKNESS (in inches)a,c
TABLE C403.2.12.1(1) FAN POWER LIMITATION
92 TABLE C403.2.12.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
93 TABLE C403.2.14(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
TABLE C403.2.14(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
94 TABLE C403.2.14(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
96 TABLE C403.3(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.3(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
TABLE C403.3.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
97 TABLE C403.3.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
98 TABLE C403.4.1.1 EFFECTIVE DATES FOR FAN CONTROL
99 TABLE C403.4.2.5 BOILER TURNDOWN
101 TABLE C403.4.6 MAXIMUM HOT GAS BYPASS CAPACITY
102 SECTION C404 SERVICE WATER HEATING (MANDATORY)
103 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
104 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
105 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
108 FIGURE C405.2.3.2(1) DAYLIGHT ZONE ADJACENT TO FENESTRATION IN A WALL
109 FIGURE C405.2.3.2(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
FIGURE C405.2.3.2(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
FIGURE C405.2.3.3 DAYLIGHT ZONE UNDER A ROOF FENESTRATION ASSEMBLY
110 EQUATION 4-9
111 TABLE C405.4.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
EQUATION 4-10
112 TABLE C405.4.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.4.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
113 TABLE C405.4.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.5.1(1) EXTERIOR LIGHTING ZONES
114 TABLE C405.7 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
115 TABLE C405.5.1(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
116 TABLE C405.8(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR 60 HZ NEMA GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE I) RATED 600 VOLTS OR LESS (Random Wound)a
117 TABLE C405.8(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY OF GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE II) AND ALL DESIGN B MOTORS GREATER THAN 200 HORSEPOWERa
TABLE C405.8(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
118 TABLE C405.8(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C407 TOTAL BUILDING PERFORMANCE
119 SECTION C408 SYSTEM COMMISSIONING
122 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
123 SECTION C503 ALTERATIONS
SECTION C504 REPAIRS
124 SECTION C505 CHANGE OF OCCUPANCY OR USE
126 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
127 AMCA
ANSI
APSP
ASHRAE
128 ASME
ASTM
129 CRRC
CSA
CTI
DASMA
DOE
130 ICC
IEEE
IES
131 ISO
NEMA
NFPA
NFRC
SMACNA
132 UL
US-FTC
WDMA
134 INDEX
144 IECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
146 CHAPTER 1 [RE] ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
147 SECTION R102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 CONSTRUCTION DOCUMENTS
148 SECTION R104 INSPECTIONS
SECTION R105 VALIDITY
SECTION R106 REFERENCED STANDARDS
149 SECTION R107 FEES
SECTION R108 STOP WORK ORDER
SECTION R109 BOARD OF APPEALS
150 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
154 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
TABLE R301.1 CLIMATE ZONE VALUES
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
155 FIGURE R301.1 CLIMATE ZONES
156 TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
158 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
159 FIGURE R401.3 A CERTIFICATE SIMILAR TO THIS SHALL BE ATTACHED TO OR NEAR THE ELECTRICAL PANEL BOARD
TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
160 TABLE R402.1.4 EQUIVALENT U-FACTORSa
161 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
163 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION
164 SECTION R403 SYSTEMS
166 TABLE R403.6.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY
SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
167 SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
168 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
TABLE R406.4 MAXIMUM ENERGY RATING INDEX
169 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
170 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
171 TABLE R405.5.2(1)—continued
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
174 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
175 SECTION R503 ALTERATIONS
SECTION R504 REPAIRS
SECTION R505 CHANGE OF OCCUPANCY OR USE
176 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
APSP
ASHRAE
177 ASTM
CSA
DASMA
ICC
178 IEEE
NFPA
NFRC
UL
US-FTC
179 WDMA
180 APPENDIX RA RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER R402.4 OR R405 CONDITIONS ≤ 5ACH50
SECTION RA101 SCOPE
SECTION RA201 GENERAL DEFINITIONS
SECTION RA301 TESTING PROCEDURE
181 TABLE RA301.1(1) CAZ DEPRESSURIZATION LIMITS
TABLE RA301.1(2) ACCEPTABLE DRAFT TEST CORRECTION
TABLE RA301.1(3) ACCEPTABLE DRAFT TEST CORRECTION
182 APPENDIX RB SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS, MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES)
SECTION RB101 SCOPE
SECTION RB102 GENERAL DEFINITION
SECTION RB103 SOLAR-READY ZONE
184 INDEX
190 ICC-SRCC SOLAR RATING & CERTIFICATION CORPORATION
191 ICC premiumACCESS
192 ICC ASSESSMENT CENTER
193 ICC MEMBERSHIP
RI EnergyCode 2019 1stptg
$28.44