Shopping Cart

No products in the cart.

RI FuelGasCode 2019 1stptg

$51.73

Rhode Island Fuel Gas Code, 1st Printing

Published By Publication Date Number of Pages
RI 2019 227
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weโ€™re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2015 IFGC.

PDF Catalog

PDF Pages PDF Title
1 2019 RHODE ISLAND FUEL GAS CODE
2 2019 RHODE ISLAND FUEL GAS CODE BASED ON THE 2015 INTERNATIONAL FUEL GAS CODEยฎ TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL FUEL GAS CODE
10 LEGISLATION
12 RHODE ISLAND STATE BUILDING CODE SBC-19 STATE FUEL GAS CODE
13 REGULATION SBC-19 STATE FUEL GAS CODE AUGUST 1, 2019
14 STATE OF RHODE ISLAND BUILDING CODE STANDARDS COMMITTEE
15 STATE BUILDING CODE REGULATIONS โ€“ 2019
16 TABLE OF CONTENTS
18 CHAPTER 23โ€“27.3 STATE BUILDING CODE
ยง 23-27.3-100.0 SCOPE
ยง 23-27.3-100.1 SHORT TITLE – APPLICABILITY
ยง 23-27.3-100.1.1 CHAPTER TITLE – APPLICABILITY
ยง 23-27.3-100.1.2 PURPOSE
ยง 23-27.3-100.1.3 CREATION OF THE STATE BUILDING CODE STANDARDS COMMITTEE
19 ยง 23-27.3-100.1.4 APPOINTMENT AND QUALIFICATIONS OF THE COMMITTEE
ยง 23-27.3-100.1.5 BUILDING CODE – ADOPTION AND PROMULGATION BY COMMITTEE
20 ยง 23-27.3-100.1.5.1 HOUSING AND MAINTENANCE CODE
ยง 23-27.3-100.1.5.2 EXISTING CODES
ยง 23-27.3-100.1.5.3 STATE REHABILITATION BUILDING AND FIRE CODE FOR EXISTING BUILDINGS AND STRUCTURES
ยง 23-27.3-100.1.5.4 STATE ENERGY CONSERVATION CODE
21 ยง 23-27.3-100.1.5.5 HURRICANE, STORM, AND FLOOD STANDARDS
ยง 23-27.3-100.1.6 COMMITTEE AS BOARD OF STANDARDS AND APPEALS – POWERS AND DUTIES – APPEALS
ยง 23-27.3-100.1.7 EFFECT OF LOCAL CODES – REPEAL OF LOCAL AUTHORITY
ยง 23-27.3-100.1.8 SEVERABILITY
ยง 23-27.3-100.2 APPLICATION OF REFERENCES
ยง 23-27.3-100.3 CONSTRUCTION
ยง 23-27.3-100.4 SPECIALIZED CODES INCORPORATED
22 ยง 23-27.3-101.0 MATTERS COVERED
ยง 23-27.3-101.1 EXEMPTION FOR ORDINARY REPAIRS
ยง 23-27.3-101.2 MATTERS NOT COVERED
ยง 23-27.3-101.2.1 PROPOSED BUILDINGS
ยง 23-27.3-101.2.2 BUILDINGS AND STRUCTURES, EXISTING AND UNDER CONSTRUCTION
ยง 23-27.3-101.3 ZONING RESTRICTIONS
ยง 23-27.3-102.0 ORDINARY REPAIRS
ยง 23-27.3-103.0 INSTALLATION OF SERVICE EQUIPMENT
ยง 23-27.3-104.0 MAINTENANCE
23 ยง 23-27.3-104.1 OWNER RESPONSIBILITY
ยง 23-27.3-105.0 CHANGE IN EXISTING USE
23-27.3-105.1 CONTINUATION OF EXISTING USE
ยง 23-27.3-105.2 CHANGE IN USE AND OCCUPANCY
ยง 23-27.3-105.3 PART CHANGE IN USE
ยง 23-27.3-105.4 REESTABLISHMENT OF A PRIOR USE
ยง 23-27.3-106.0 EXISTING STRUCTURES
ยง 23-27.3-106.1 SUBSTANTIAL IMPROVEMENTS
ยง 23-27.3-106.2 SUBSTANTIAL DAMAGES EXCEEDING FIFTY PERCENT
24 ยง 23-27.3-106.3 IMPROVEMENTS AND DAMAGES BETWEEN TWENTY-FIVE AND FIFTY PERCENT OF VALUE
ยง 23-27.3-106.4 IMPROVEMENTS OR DAMAGES UNDER TWENTY-FIVE PERCENT OF VALUE
ยง 23-27.3-106.5 PHYSICAL VALUE
ยง 23-27.3-107.0 DEPARTMENT OF BUILDING INSPECTION
ยง 23-27.3-107.1 LOCAL BUILDING OFFICIAL – APPOINTMENT
ยง 23-27.3-107.1.1 LOCAL INSPECTOR
ยง 23-27.3-107.2 ALTERNATE LOCAL BUILDING OFFICIAL
25 ยง 23-27.3-107.3 APPOINTMENT OF PERSONNEL BY STATE BUILDING COMMISSIONER
ยง 23-27.3-107.4 QUALIFICATIONS AND DUTIES OF THE STATE BUILDING COMMISSIONER
ยง 23-27.3-107.5 LOCAL BUILDING OFFICIAL – QUALIFICATIONS – POWERS AND DUTIES
ยง 23-27.3-107.6 CERTIFICATION OF LOCAL BUILDING OFFICIALS – EDUCATIONAL PROGRAMS
26 ยง 23-27.3-107.7 RECERTIFICATION AND CONTINUING EDUCATION
ยง 23-27.3-107.8 RESTRICTION ON EMPLOYEES’ ACTIVITIES
ยง 23-27.3-107.9 RELIEF FROM PERSONAL RESPONSIBILITY
ยง 23-27.3-108.0 DUTIES AND POWERS OF THE BUILDING OFFICIAL AND THE STATE BUILDING COMMISSIONER
ยง 23-27.3-108.1 LOCAL BUILDING OFFICIAL – ENFORCEMENT DUTIES
ยง 23-27.3-108.1.1 APPLICATIONS AND PERMITS
ยง 23-27.3-108.1.3 NEW MATERIALS AND METHODS OF CONSTRUCTION
27 ยง 23-27.3-108.1.3.1 TEST RESULTS
ยง 23-27.3-108.1.3.2 RETESTING
ยง 23-27.3-108.1.4 INSPECTIONS
ยง 23-27.3-108.1.5 REPLEALED
ยง 23-27.3-108.1.6 ADMINISTRATIVE PROCEDURES
ยง 23-27.3-108.1.7 DEPARTMENT RECORDS
ยง 23-27.3-108.1.8 REPORTS
ยง 23-27.3-108.2 STATE BUILDING COMMISSIONER’S DUTIES
28 ยง 23-27.3-108.2.0.1 REPEALED
ยง 23-27.3-108.2.1 DUTIES OF COMMITTEE
23-27.3-108.2.2 COMPENSATION OF COMMITTEE MEMBERS
ยง 23-27.3-108.2.3 EMERGENCY PROCEDURES
ยง 23-27.3-108.2.4 MUNICIPAL ADVISORY COUNCIL ON STATEWIDE PERMITTING
ยง 23-27.3-109.0 COMMITTEE
ยง 23-27.3-109.1 COMMITTEE’S RULE MAKING AUTHORITY – LEGISLATIVE REPORT – LEGISLATIVE COMMITTEE
29 ยง 23-27.3-109.1.1 COMMITTEE – LICENSING OF LABORATORIES AND TEST PERSONNEL
ยง 23-27.3-109.1.2 COMMITTEE – REGULATION OF MANUFACTURED BUILDINGS
ยง 23-27.3-109.1.3 ADOPTION OF FEDERAL STANDARDS FOR MANUFACTURED HOMES
ยง 23-27.3-109.1.3.1 INSPECTION OF MANUFACTURED HOMES MANUFACTURERS
ยง 23-27.3-109.1.3.2 PENALTIES FOR VIOLATION AS TO MANUFACTURED HOMES
30 ยง 23-27.3-109.1.3.3 MONITORING INSPECTION FEE
ยง 23-27.3-109.1.3.4 REPORTS OF MANUFACTURED HOME MANUFACTURERS, DISTRIBUTORS, AND DEALERS
ยง 23-27.3-109.1.3.5 TEMPORARY GREENHOUSE DEFINED
ยง 23-27.3-109.1.4 REPEALED
ยง 23-27.3-109.2 ACCEPTED ENGINEERING PRACTICE
ยง 23-27.3-109.3 PROPOSING AMENDMENTS TO RULES AND REGULATIONS
ยง 23-27.3-110.0 MODIFICATIONS AND VARIANCES
ยง 23-27.3-111.0 NEW AND ALTERED BUILDING AND STRUCTURE – INSPECTIONS
ยง 23-27.3-111.1 PRELIMINARY INSPECTION
ยง 23-27.3-111.2 INSPECTION
31 ยง 23-27.3-111.3 MANUFACTURING BUILDINGS
23-27.3-111.3.1 PLANT INSPECTION
ยง 23-27.3-111.3.2 INSTALLATION SITE INSPECTION
ยง 23-27.3-111.4 EXISTING BUILDINGS
ยง 23-27.3-111.4.1 PERIODIC INSPECTIONS
ยง 23-27.3-111.4.2 REPLEALED
ยง 23-27.3-111.5 FINAL INSPECTION
23-27.3-111.6 INSPECTION SERVICES
ยง 23-27.3-111.7 COORDINATION OF INSPECTIONS
ยง 23-27.3-112.0 RIGHT OF ENTRY
ยง 23-27.3-112.1 OFFICIAL IDENTIFICATION CARD
32 ยง 23-27.3-112.2 MUNICIPAL COOPERATION
ยง 23-27.3-113.0 APPLICATION FOR PERMIT
ยง 23-27.3-113.1 WHEN PERMIT IS REQUIRED
ยง 23-27.3-113.1.1 ISSUANCE OF PERMITS FOR SIDING
ยง 23-27.3-113.2 FORM OF APPLICATION
ยง 23-27.3-113.3 BY WHOM APPLICATION IS MADE
ยง 23-27.3-113.3.1 APPLICATIONS FOR WORK REQUIRING LICENSED WORKERS
ยง 23-27.3-113.3.2 APPLICATIONS FOR WORK REQUIRING REGISTERED WORKERS
33 ยง 23-27.3-113.4 DESCRIPTION OF WORK
ยง 23-27.3-113.5 PLANS AND SPECIFICATIONS
ยง 23-27.3-113.5.1 REPLEALED
ยง 23-27.3-113.6 PLOT PLAN
ยง 23-27.3-113.6.1 APPROVAL OF AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM
ยง 23-27.3-113.7 ENGINEERING DETAILS
ยง 23-27.3-113.8 AMENDMENTS TO APPLICATION
ยง 23-27.3-113.9 TIME LIMITATION ON APPLICATION
ยง 23-27.3-114.0 PERMITS
ยง 23-27.3-114.1 ACTION ON APPLICATION
34 ยง 23-27.3-114.1.1 REPORTS TO ASSESSORS
ยง 23-27.3-114.2 EXPIRATION OF PERMIT
ยง 23-27.3-114.3 PREVIOUS APPROVALS
35 ยง 23-27.3-114.3.1 DRAWINGS AND SPECIFICATIONS
ยง 23-27.3-114.4 BUILDING OFFICIAL TO SIGN PERMIT
ยง 23-27.3-114.5 APPROVED PLANS
ยง 23-27.3-114.6 REVOCATION OF PERMITS
ยง 23-27.3-114.7 APPROVAL IN PART
ยง 23-27.3-114.8 POSTING OF PERMIT
ยง 23-27.3-114.9 NOTICE OF BUILDING START
ยง 23-27.3-115.0 CONDITIONS OF PERMIT
ยง 23-27.3-115.1 COMPLIANCE WITH CODE
ยง 23-27.3-115.2 COMPLIANCE WITH PERMIT
ยง 23-27.3-115.3 COMPLIANCE WITH PLOT PLAN
ยง 23-27.3-115.4 CHANGE IN PLOT PLAN
36 ยง 23-27.3-115.5 DISMISSAL OF CONTRACTOR OR SUBCONTRACTOR
ยง 23-27.3-116.0 MOVING, RAISING, SHORING, OR DEMOLITION OF BUILDINGS
ยง 23-27.3-116.1 SERVICE CONNECTIONS
ยง 23-27.3-116.2 BUILDINGS TO BE RODENT-ERADICATED PRIOR TO DEMOLITION
ยง 23-27.3-116.3 DESCRIPTION AND INSPECTION OF BUILDINGS – TRAVEL ROUTE
ยง 23-27.3-116.4 AGREEMENT CONDITION TO MOVING
ยง 23-27.3-116.5 PUBLIC UTILITIES, WIRES, POLES, TREES, AND SHRUBS
ยง 23-27.3-116.6 MOVING TO BE CONTINUOUS
ยง 23-27.3-116.7 WATCHPERSON AND LIGHTS DURING MOVING
37 ยง 23-27.3-116.8 BONDS AND LIABILITY INSURANCE
ยง 23-27.3-116.9 SHORING
ยง 23-27.3-117.0 REMOVAL OF STRUCTURES
ยง 23-27.3-117.1 LOT REGULATION
ยง 23-27.3-118.0 FEES
ยง 23-27.3-118.1 SPECIAL FEES
ยง 23-27.3-118.2 RAMPS FOR DISABLED PERSONS
ยง 23-27.3-119.0 FEE COMPUTATION
ยง 23-27.3-120.0 CERTIFICATE OF USE AND OCCUPANCY
ยง 23-27.3-120.1 NEW BUILDINGS
ยง 23-27.3-120.2 BUILDINGS HEREAFTER ALTERED
38 ยง 23-27.3-120.3 EXISTING BUILDINGS
ยง 23-27.3-120.4 CHANGES IN USE AND OCCUPANCY
ยง 23-27.3-120.5 TEMPORARY OCCUPANCY
ยง 23-27.3-120.6 CONTENTS OF CERTIFICATE
ยง 23-27.3-121.0 POSTING BUILDINGS
ยง 23-27.3-121.1 POSTED USE AND OCCUPANCY
39 ยง 23-27.3-121.2 POSTED OCCUPANCY LOAD
ยง 23-27.3-121.3 FURNISHING OF POSTED SIGNS
ยง 23-27.3-121.4 PERIODIC INSPECTION FOR POSTING
ยง 23-27.3-122.0 VIOLATIONS
ยง 23-27.3-122.1 NOTICE OF VIOLATION
ยง 23-27.3-122.1.2 NOTICE OR ORDERS – SERVICE AND CONTENT
23-27.3-122.2 PROSECUTION OF VIOLATION
ยง 23-27.3-122.3 PENALTIES
ยง 23-27.3-122.4 ABATEMENT OF VIOLATIONS
40 ยง 23-27.3-123.0 STOP-WORK ORDER
ยง 23-27.3-123.1 NOTICE TO OWNER
ยง 23-27.3-123.1.1 POSTING OF ORDER
ยง 23-27.3-123.2 UNLAWFUL CONTINUANCE
ยง 23-27.3-124.0 UNSAFE STRUCTURES – GENERAL PROVISIONS
ยง 23-27.3-124.1 UNSAFE CONDITIONS
ยง 23-27.3-124.2 NOTICE OF UNSAFE CONDITION
41 ยง 23-27.3-124.3 APPEALS
ยง 23-27.3-124.4 RESTORATION OF UNSAFE BUILDINGS
ยง 23-27.3-124.4.1 COMPLIANCE
ยง 23-27.3-124.5 DISREGARD OF UNSAFE NOTICE
ยง 23-27.3-124.6 BOARDING
42 ยง 23-27.3-124.6.1 DISCONNECTION OF UTILITIES
ยง 23-27.3-124.6.2 REMOVAL OF DEBRIS AND RUBBISH
ยง 23-27.3-125.0 ENERGENCY MEASURES
ยง 23-27.3-125.1 VACATING BUILDINGS
ยง 23-27.3-125.2 TEMPORARY SAFEGUARDS
ยง 23-27.3-125.3 CLOSING STREETS
ยง 23-27.3-125.4 EMERGENCY REPAIRS
ยง 23-27.3-125.5 HAZARDOUS BUILDINGS
ยง 23-27.3-125.6 COSTS OF EMERGENCY REPAIRS
ยง 23-27.3-125.7 LIEN FOR EMERGENCY REPAIRS
ยง 23-27.3-126.0 APPEALS FROM ORDERS IN REGARD TO UNSAFE BUILDINGS
43 ยง 23-27.3-126.1 APPLICATION FOR REVIEW
ยง 23-27.3-126.2 PROCEDURE
ยง 23-27.3-126.3 FINDINGS
ยง 23-27.3-127.0 STATE AND LOCAL BOARDS OF APPEALS
ยง 23-27.3-127.1 COMMITTEE TO SERVE AS A BOARD OF STANDARDS AND APPEALS
44 ยง 23-27.3-127.1.1 STAY OF PROCEEDINGS
ยง 23-27.3-127.1.2 GRANTING VARIANCE
ยง 23-27.3-127.1.3 ADDITIONAL POWERS
ยง 23-27.3-127.1.4 PROCEDURES – RECORD OF VARIANCES
45 ยง 23-27.3-127.2 LOCAL BOARD OF APPEALS
ยง 23-27.3-127.2.1 MEMBERSHIP AND LOCAL BOARD
ยง 23-27.3-127.2.2 STAY OF PROCEEDINGS
ยง 23-27.3-127.2.3 GRANTING VARIANCE
ยง 23-27.3-127.2.4 ADDITIONAL POWERS
ยง 23-27.3-127.2.5 PROCEDURES
46 ยง 23-27.3-127.2.6 LOCAL DECISION TRANSMITTED TO STATE BOARD
ยง 23-27.3-128.0 DESIGN AND CONSTRUCTION PROCEDURES
ยง 23-27.3-128.1 SCOPE
ยง 23-27.3-128.1.1 OWNER’S RESPONSIBILITIES
ยง 23-27.3-128.1.2 โ€“ 23-27.3-128.1.5 REPEALED
ยง 23-27.3-128.2 REPEALED
ยง 23-27.3-128.2.1 DRAWINGS AND SPECIFICATIONS
ยง 23-27.3-128.2.2 RESPONSIBILITIES
47 ยง 23-27.3-128.2.3 REPORTING
ยง 23-27.3-128.3 CONSTRUCTION CONTRACTOR RESPONSIBILITIES
ยง 23-27.3-128.4 TESTING REQUIRED
ยง 23-27.3-128.5 BUILDING OFFICIAL’S RESPONSIBILITIES
ยง 23-27.3-128.5.1 WAIVER OF PLAN EXAMINATION
ยง 23-27.3-128.5.2 WAIVER OF DETAILED FIELD INSPECTION
48 ยง 23-27.3-128.5.3 INSPECTION WAIVER – UTILIZATION
ยง 23-27.3-128.5.4 BUILDING PERMIT ISSUANCE OR REQUIREMENTS
ยง 23-27.3-128.6 SPECIAL TECHNICAL SERVICES
ยง 23-27.3-128.7 FEES AND COSTS
ยง 23-27.3-129.0, 23-27.3-129.1 REPEALED
ยง 23-27.3-129.2 REPEALED
ยง 23-27.3-129.3 REPEALED
ยง 23-27.3-200.0 SAVINGS CLAUSE
ยง 23-27.3-300.0 PUBLICATION OF CODE
ยง 23-27.3-400.0 SEVERABILITY
49 ยง 23-27.3-401.0 SALE OF PRESSURE VESSEL
ยง 23-27.3-500.0 EFFECTIVE DATE OF CODE
ยง 23-27.3-501.0, 23-27.3-502.0 REPEALED
ยง 23-27.3-503.0, 23-27.3-504.0 [OBSOLETE]
ยง 23-27.3-505.0 REPEALED
ยง 23-27.3-506.0 [OBSOLETE]
ยง 23-27.3-600.0 FRESH WATER WETLANDS
ยง 23-27.3-700.0 REPEALED
ยง 23-27.3-701.0 BABY CHANGING TABLES
50 CHAPTER 1 ADMINISTRATION
PART 1โ€”SCOPE AND APPLICATION
SECTION 101 (IFGC) GENERAL
51 SECTION 102 (IFGC) APPLICABILITY
52 PART 2โ€”ADMINISTRATION AND ENFORCEMENT
SECTION 103 (IFGC) DEPARTMENT OF INSPECTION
SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 (IFGC) APPROVAL
SECTION 106 (IFGC) PERMITS
SECTION 107 (IFGC) INSPECTIONS AND TESTING
53 SECTION 108 (IFGC) VIOLATIONS
SECTION 109 (IFGC) MEANS OF APPEAL
54 SECTION 110 (IFGC) TEMPORARY EQUIPMENT, SYSTEMS AND USES
56 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
66 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
67 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
68 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 3-1
EQUATION 3-2
69 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORSโ€”INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
70 FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2)
71 SECTION 305 (IFGC) INSTALLATION
72 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
74 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
75 TABLE 308.2 a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
76 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
77 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
SECTION 311 TEMPERATURE CONTROL
78 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
79 EQUATION 4-1
EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
80 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
81 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
82 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
83 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
84 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
85 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
86 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
87 TABLE 402.4(8) SEMIRIGID COPPER TUBING
88 TABLE 402.4(9) SEMIRIGID COPPER TUBING
89 TABLE 402.4(10) SEMIRIGID COPPER TUBING
90 TABLE 402.4(11) SEMIRIGID COPPER TUBING
91 TABLE 402.4(12) SEMIRIGID COPPER TUBING
92 TABLE 402.4(13) SEMIRIGID COPPER TUBING
93 TABLE 402.4(14) SEMIRIGID COPPER TUBING
94 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
95 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
96 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
97 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
98 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
99 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
100 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
101 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
102 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
103 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
104 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
105 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
106 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
107 TABLE 402.4(29) SEMIRIGID COPPER TUBING
108 TABLE 402.4(30) SEMIRIGID COPPER TUBING
109 TABLE 402.4(31) SEMIRIGID COPPER TUBING
110 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
111 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
112 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
113 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
114 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
115 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
116 SECTION 403 (IFGS) PIPING MATERIALS
117 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
118 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
120 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
121 SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
122 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
123 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION 409 (IFGC) SHUTOFF VALVES
124 TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
SECTION 410 (IFGC) FLOW CONTROLS
125 SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
126 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
127 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
129 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
132 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
133 SECTION 502 (IFGC) VENTS
134 SECTION 503 (IFGS) VENTING OF APPLIANCES
135 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
137 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
140 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
141 TABLE 503.10.5a CLEARANCES FOR CONNECTORS
143 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
145 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
147 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
148 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
149 TABLE 504.2(1)โ€”continued TYPE B DOUBLE-WALL GAS VENT
150 TABLE 504.2(1)โ€”continued TYPE B DOUBLE-WALL GAS VENT
151 TABLE 504.2(1)โ€”continued TYPE B DOUBLE-WALL GAS VENT
152 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
153 TABLE 504.2(2)-continued TYPE B DOUBLE-WALL GAS VENT
154 TABLE 504.2(3) MASONRY CHIMNEY
155 TABLE 504.2(3)โ€”continued MASONRY CHIMNEY
156 TABLE 504.2(4) MASONRY CHIMNEY
157 TABLE 504.2(4)โ€”continued MASONRY CHIMNEY
158 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
159 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
160 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
161 TABLE 504.3(1)-continued TYPE B DOUBLE-WALL VENT
162 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
163 TABLE 504.3(3) MASONRY CHIMNEY
164 TABLE 504.3(4) MASONRY CHIMNEY
165 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
166 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY-continued
167 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEYโ€”continued
168 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
169 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
170 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
171 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
172 SECTION 615 (IFGC) SAUNA HEATERS
173 SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
174 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
175 SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
176 SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
SECTION 628 (IFGC) ILLUMINATING APPLIANCES
177 SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
178 SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
180 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
181 SECTION 704 (IFGC) PIPING, USE AND HANDLING
182 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
183 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
184 SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
186 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
187 ASME
ASTM
CGA
188 CSA
DOTn
ICC
MSS
189 NFPA
UL
190 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
191 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
192 TABLE A.2.2โ€”continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
193 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
195 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
196 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
197 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
198 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
199 FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
202 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
203 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
204 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
205 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
206 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
207 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
209 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
210 FIGURE B-19
212 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
214 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
215 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
216 D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
217 D.6 APPLIANCE-SPECIFIC INSPECTIONS
219 TABLE D.6 CO THRESHOLDS
220 INDEX
224 ICC EVALUATION SERVICE
225 ICC LEARNING CENTER
226 ICC ASSESSMENT CENTER
227 ICC MEMBERSHIP