RI PlumbingCode 2019 1stptg
$51.73
Rhode Island Plumbing Code, 1st Printing
Published By | Publication Date | Number of Pages |
RI | 2019 | 219 |
This is a fully integrated code based on the 2015 IPC.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2019 RHODE ISLAND PLUMBING CODE |
2 | 2019 RHODE ISLAND PLUMBING CODE BASED ON THE 2015 INTERNATIONAL PLUMBING CODEยฎ TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
8 | EFFECTIVE USE OF THE INTERNATIONAL PLUMBING CODE |
12 | LEGISLATION |
14 | RHODE ISLAND STATE BUILDING CODE SBC-3 STATE PLUMBING CODE |
15 | REGULATION SBC-3 STATE PLUMBING CODE AUGUST 1, 2019 |
16 | STATE OF RHODE ISLAND BUILDING CODE STANDARDS COMMITTEE |
17 | STATE BUILDING CODE REGULATIONS โ 2019 |
18 | TABLE OF CONTENTS |
22 | CHAPTER 23โ27.3 STATE BUILDING CODE ยง 23-27.3-100.0 SCOPE ยง 23-27.3-100.1 SHORT TITLE – APPLICABILITY ยง 23-27.3-100.1.1 CHAPTER TITLE – APPLICABILITY ยง 23-27.3-100.1.2 PURPOSE ยง 23-27.3-100.1.3 CREATION OF THE STATE BULDING CODE STANDARDS COMMITTEE |
23 | ยง 23-27.3-100.1.4 APPOINTMENT AND QUALIFICATIONS OF THE COMMITTEE ยง 23-27.3-100.1.5 BUILDING CODE – ADOPTION AND PROMULGATION BY COMMITTEE |
24 | ยง 23-27.3-100.1.5.1 HOUSING AND MAINTENANCE CODE ยง 23-27.3-100.1.5.2 EXISTING CODES ยง 23-27.3-100.1.5.3 STATE REHABILITATION BUILDING AND FIRE CODE FOR EXISTING BUILDINGS AND STRUCTURES ยง 23-27.3-100.1.5.4 STATE ENERGY CONSERVATION CODE |
25 | ยง 23-27.3-100.1.5.5 HURRICANE, STORM, AND FLOOD STANDARDS ยง 23-27.3-100.1.6 COMMITTEE AS BOARD OF STANDARDS AND APPEALS – POWERS AND DUTIES – APPEALS ยง 23-27.3-100.1.7 EFFECT OF LOCAL CODES – REPEAL OF LOCAL AUTHORITY ยง 23-27.3-100.1.8 SEVERABILITY ยง 23-27.3-100.2 APPLICATION OF REFERENCES ยง 23-27.3-100.3 CONSTRUCTION ยง 23-27.3-100.4 SPECIALIZED CODES INCORPORATED |
26 | ยง 23-27.3-101.0 MATTERS COVERED ยง 23-27.3-101.1 EXEMPTION FOR ORDINARY REPAIRS ยง 23-27.3-101.2 MATTERS NOT COVERED ยง 23-27.3-101.2.1 PROPOSED BUILDINGS ยง 23-27.3-101.2.2 BUILDINGS AND STRUCTURES, EXISTING AND UNDER CONSTRUCTION ยง 23-27.3-101.3 ZONING RESTRICTIONS ยง 23-27.3-102.0 ORDINARY REPAIRS ยง 23-27.3-103.0 INSTALLATION OF SERVICE EQUIPMENT ยง 23-27.3-104.0 MAINTENANCE |
27 | ยง 23-27.3-104.1 OWNER RESPONSIBILITY ยง 23-27.3-105.0 CHANGE IN EXISTING USE ยง 23-27.3-105.1 CONTINUATION OF EXISTING USE ยง 23-27.3-105.2 CHANGE IN USE AND OCCUPANCY ยง 23-27.3-105.3 PART CHANGE IN USE ยง 23-27.3-105.4 REESTABLISHMENT OF A PRIOR USE ยง 23-27.3-106.0 EXISTING STRUCTURES ยง 23-27.3-106.1 SUBSTANTIAL IMPROVEMENTS ยง 23-27.3-106.2 SUBSTANTIAL DAMAGES EXCEEDING FIFTY PERCENT |
28 | ยง 23-27.3-106.3 IMPROVEMENTS AND DAMAGES BETWEEN TWENTY-FIVE AND FIFTY PERCENT OF VALUE ยง 23-27.3-106.4 IMPROVEMENTS OR DAMAGES UNDER TWENTY-FIVE PERCENT OF VALUE ยง 23-27.3-106.5 PHYSICAL VALUE ยง 23-27.3-107.0 DEPARTMENT OF BUILDING INSPECTION ยง 23-27.3-107.1 LOCAL BUILDING OFFICIAL – APPOINTMENT ยง 23-27.3-107.1.1 LOCAL INSPECTOR – ยง 23-27.3-107.2 ALTERNATE LOCAL BUILDING OFFICIAL |
29 | ยง 23-27.3-107.3 APPOINTMENT OF PERSONNEL BY STATE BUILDING COMMISSIONER ยง 23-27.3-107.4 QUALIFICATIONS AND DUTIES OF THE STATE BUILDING COMMISSIONER ยง 23-27.3-107.5 LOCAL BUILDING OFFICIAL – QUALIFICATIONS – POWERS AND DUTIES ยง 23-27.3-107.6 CERTIFICATION OF LOCAL BUILDING OFFICIALS – EDUCATIONAL PROGRAMS |
30 | ยง 23-27.3-107.7 RECERTIFICATION AND CONTINUING EDUCATION ยง 23-27.3-107.8 RESTRICTION ON EMPLOYEES’ ACTIVITIES ยง 23-27.3-107.9 RELIEF FROM PERSONAL RESPONSIBILITY ยง 23-27.3-108.0 DUTIES AND POWERS OF THE BUILDING OFFICIAL AND THE STATE BUILDING COMMISSIONER ยง 23-27.3-108.1 LOCAL BUILDING OFFICIAL – ENFORCEMENT DUTIES ยง 23-27.3-108.1.1 APPLICATIONS AND PERMITS ยง 23-27.3-108.1.3 NEW MATERIALS AND METHODS OF CONSTRUCTION |
31 | ยง 23-27.3-108.1.3.1 TEST RESULTS ยง 23-27.3-108.1.3.2 RETESTING ยง 23-27.3-108.1.4 INSPECTIONS ยง 23-27.3-108.1.5 REPEALED ยง 23-27.3-108.1.6 ADMINISTRATIVE PROCEDURES ยง 23-27.3-108.1.7 DEPARTMENT RECORDS ยง 23-27.3-108.1.8 REPORTS ยง 23-27.3-108.2 STATE BUILDING COMMISSIONER’S DUTIES |
32 | ยง 23-27.3-108.2.0.1 REPEALED ยง 23-27.3-108.2.1 DUTIES OF COMMITTEE ยง 23-27.3-108.2.2 COMPENSATION OF COMMITTEE MEMBERS ยง 23-27.3-108.2.3 EMERGENCY PROCEDURES ยง 23-27.3-108.2.4 MUNICIPAL ADVISORY COUNCIL ON STATEWIDE PERMITTING ยง 23-27.3-109.0 COMMITTEE ยง 23-27.3-109.1 COMMITTEE’S RULE MAKING AUTHORITY – LEGISLATIVE REPORT – LEGISLATIVE COMMITTEE |
33 | ยง 23-27.3-109.1.1 COMMITTEE – LICENSING OF LABORATORIES AND TEST PERSONNEL ยง 23-27.3-109.1.2 COMMITTEE – REGULATION OF MANUFACTURED BUILDINGS ยง 23-27.3-109.1.3 ADOPTION OF FEDERAL STANDARDS FOR MANUFACTURED HOMES ยง 23-27.3-109.1.3.1 INSPECTION OF MANUFACTURED HOMES MANUFACTURERS ยง 23-27.3-109.1.3.2 PENALTIES FOR VIOLATION AS TO MANUFACTURED HOMES |
34 | ยง 23-27.3-109.1.3.3 MONITORING INSPECTION FEE ยง 23-27.3-109.1.3.4 REPORTS OF MANUFACTURED HOME MANUFACTURERS, DISTRIBUTORS, AND DEALERS ยง 23-27.3-109.1.3.5 TEMPORARY GREENHOUSE DEFINED ยง 23-27.3-109.1.4 REPEALED ยง 23-27.3-109.2 ACCEPTED ENGINEERING PRACTICE ยง 23-27.3-109.3 PROPOSING AMENDMENTS TO RULES AND REGULATIONS ยง 23-27.3-110.0 MODIFICATIONS AND VARIANCES ยง 23-27.3-111.0 NEW AND ALTERED BUILDING AND STRUCTURE – INSPECTIONS ยง 23-27.3-111.1 PRELIMINARY INSPECTION ยง 23-27.3-111.2 INSPECTION |
35 | ยง 23-27.3-111.3 MANUFACTURING BUILDINGS ยง 23-27.3-111.3.1 PLANT INSPECTION ยง 23-27.3-111.3.2 INSTALLATION SITE INSPECTION ยง 23-27.3-111.4 EXISTING BUILDINGS ยง 23-27.3-111.4.1 PERIODIC INSPECTIONS ยง 23-27.3-111.4.2 REPEALED ยง 23-27.3-111.5 FINAL INSPECTION ยง 23-27.3-111.6 INSPECTION SERVICES ยง 23-27.3-111.7 COORDINATION OF INSPECTIONS ยง 23-27.3-112.0 RIGHT OF ENTRY ยง 23-27.3-112.1 OFFICIAL IDENTIFICATION CARD |
36 | ยง 23-27.3-112.2 MUNICIPAL COOPERATION ยง 23-27.3-113.0 APPLICATION FOR PERMIT ยง 23-27.3-113.1 WHEN PERMIT IS REQUIRED ยง 23-27.3-113.1.1 ISSUANCE OF PERMITS FOR SIDING ยง 23-27.3-113.2 FORM OF APPLICATION – ยง 23-27.3-113.3 BY WHOM APPLICATION IS MADE – ยง 23-27.3-113.3.1 APPLICATIONS FOR WORK REQUIRING LICENSED WORKERS ยง 23-27.3-113.3.2 APPLICATIONS FOR WORK REQUIRING REGISTERED WORKERS |
37 | ยง 23-27.3-113.4 DESCRIPTION OF WORK ยง 23-27.3-113.5 PLANS AND SPECIFICATIONS ยง 23-27.3-113.5.1 REPEALED ยง 23-27.3-113.6 PLOT PLAN ยง 23-27.3-113.6.1 APPROVAL OF AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM ยง 23-27.3-113.7 ENGINEERING DETAILS ยง 23-27.3-113.8 AMENDMENTS TO APPLICATION ยง 23-27.3-113.9 TIME LIMITATION ON APPLICATION ยง 23-27.3-114.0 PERMITS ยง 23-27.3-114.1 ACTION ON APPLICATION |
38 | ยง 23-27.3-114.1.1 REPORTS TO ASSESSORS ยง 23-27.3-114.2 EXPIRATION OF PERMIT ยง 23-27.3-114.3 PERVIOUS APPROVALS |
39 | ยง 23-27.3-114.3.1 DRAWINGS AND SPECIFICATIONS ยง 23-27.3-114.4 BUILDING OFFICIAL TO SIGN PERMIT ยง 23-27.3-114.5 APPROVED PLANS ยง 23-27.3-114.6 REVOCATION OF PERMITS ยง 23-27.3-114.7 APPROVAL IN PART ยง 23-27.3-114.8 POSTING OF PERMIT ยง 23-27.3-114.9 NOTICE OF BUILDING START ยง 23-27.3-115.0 CONDITIONS OF PERMIT ยง 23-27.3-115.1 COMPLIANCE WITH CODE ยง 23-27.3-115.2 COMPLIANCE WITH PERMIT ยง 23-27.3-115.3 COMPLIANCE WITH PLOT PLAN ยง 23-27.3-115.4 CHANGE IN PLOT PLAN |
40 | ยง 23-27.3-115.5 DISMISSAL OF CONTRACTOR OR SUBCONTRACTOR ยง 23-27.3-116.0 MOVING, RAISING, SHORING, OR DEMOLITION OF BUILDINGS ยง 23-27.3-116.1 SERVICE CONNECTIONS ยง 23-27.3-116.2 BUILDINGS TO BE RODENT-ERADICATED PRIOR TO DEMOLITION ยง 23-27.3-116.3 DESCRIPTION AND INSPECTION OF BUILDINGS – TRAVEL ROUTE ยง 23-27.3-116.4 AGREEMENT CONDITION TO MOVING ยง 23-27.3-116.5 PUBLIC UTILITIES, WIRES, POLES, TREES AND SHRUBS ยง 23-27.3-116.6 MOVING TO BE CONTINUOUS ยง 23-27.3-116.7 WATCHPERSON AND LIGHTS DURING MOVING |
41 | ยง 23-27.3-116.8 BONDS AND LIABILITY INSURANCE ยง 23-27.3-116.9 SHORING ยง 23-27.3-117.0 REMOVAL OF STRUCTURES ยง 23-27.3-117.1 LOT REGULATION ยง 23-27.3-118.0 FEES ยง 23-27.3-118.1 SPECIAL FEES ยง 23-27.3-118.2 RAMPS FOR DISABLED PERSONS ยง 23-27.3-119.0 FEE COMPUTATION ยง 23-27.3-120.0 CERTIFICATE OF USE AND OCCUPANCY ยง 23-27.3-120.1 NEW BUILDINGS ยง 23-27.3-120.2 BUILDINGS HEREAFTER ALTERED |
42 | ยง 23-27.3-120.3 EXISTING BUILDINGS ยง 23-27.3-120.4 CHANGES IN USE AND OCCUPANCY ยง 23-27.3-120.5 TEMPORARY OCCUPANCY ยง 23-27.3-120.6 CONTENTS OF CERTIFICATE ยง 23-27.3-121.0 POSTING BUILDINGS ยง 23-27.3-121.1 POSTED USE AND OCCUPANCY |
43 | ยง 23-27.3-121.2 POSTED OCCUPANCY LOAD ยง 23-27.3-121.3 FURNISHING OF POSTED SIGNS ยง 23-27.3-121.4 PERIODIC INSPECTION FOR POSTING ยง 23-27.3-122.0 VIOLATIONS ยง 23-27.3-122.1 NOTICE OF VIOLATION ยง 23-27.3-122.1.2 NOTICE OR ORDERS – SERVICE AND CONTENT ยง 23-27.3-122.2 PROSECUTION OF VIOLATION ยง 23-27.3-122.3 PENALTIES ยง 23-27.3-122.4 ABATEMENT OF VIOLATIONS |
44 | ยง 23-27.3-123.0 STOP-WORK ORDER ยง 23-27.3-123.1 NOTICE TO OWNER ยง 23-27.3-123.1.1 POSTING OF ORDER ยง 23-27.3-123.2 UNLAWFUL CONTINUANCE ยง 23-27.3-124.0 UNSAFE STRUCTURES – GENERAL PROVISIONS ยง 23-27.3-124.1 UNSAFE CONDITIONS ยง 23-27.3-124.2 NOTICE OF UNSAFE CONDITION |
45 | ยง 23-27.3-124.3 APPEALS ยง 23-27.3-124.4 RESTORATION OF UNSAFE BUILDINGS ยง 23-27.3-124.4.1 COMPLIANCE ยง 23-27.3-124.5 DISREGARD OF UNSAFE NOTICE ยง 23-27.3-124.6 BOARDING |
46 | ยง 23-27.3-124.6.1 DISCONNECTION OF UTILITIES ยง 23-27.3-124.6.2 REMOVAL OF DEBRIS AND RUBBISH ยง 23-27.3-125.0 EMERGENCY MEASURES ยง 23-27.3-125.1 VACATING BUILDINGS ยง 23-27.3-125.2 TEMPORARY SAFEGUARDS ยง 23-27.3-125.3 CLOSING STREETS ยง 23-27.3-125.4 EMERGENCY REPAIRS ยง 23-27.3-125.5 HAZARDOUS BUILDINGS ยง 23-27.3-125.6 COSTS OF EMERGENCY REPAIRS ยง 23-27.3-125.7 LIEN FOR EMERGENCY REPAIRS ยง 23-27.3-126.0 APPEALS FROM ORDERS IN REGARD TO UNSAFE BUILDINGS |
47 | ยง 23-27.3-126.1 APPLICATION FOR REIVEW ยง 23-27.3-126.2 PROCEDURE ยง 23-27.3-126.3 FINDINGS ยง 23-27.3-127.0 STATE AND LOCAL BOARDS OF APPEALS ยง 23-27.3-127.1 COMMITTEE TO SERVE AS A BOARD OF STANDARDS AND APPEALS |
48 | ยง 23-27.3-127.1.1 STAY OF PROCEEDINGS ยง 23-27.3-127.1.2 GRANTING VARIANCE ยง 23-27.3-127.1.3 ADDITIONAL POWERS ยง 23-27.3-127.1.4 PROCEDURES – RECORD OF VARIANCES |
49 | ยง 23-27.3-127.2 LOCAL BOARD OF APPEALS ยง 23-27.3-127.2.1 MEMBERSHIP AND LOCAL BOARD ยง 23-27.3-127.2.2 STAY OF PROCEEDINGS ยง 23-27.3-127.2.3 GRANTING VARIANCE ยง 23-27.3-127.2.4 ADDITIONAL POWERS ยง 23-27.3-127.2.5 PROCEDURES |
50 | ยง 23-27.3-127.2.6 LOCAL DECISION TRANSMITTED TO STATE BOARD ยง 23-27.3-128.0 DESIGN AND CONSTRUCTION PROCEDURES ยง 23-27.3-128.1 SCOPE ยง 23-27.3-128.1.1 OWNER’S RESPONSIBILITIES ยง 23-27.3-128.1.2 โ 23-27.3-128.1.5 REPEALED ยง 23-27.3-128.2 REPEALED ยง 23-27.3-128.2.1 DRAWINGS AND SPECIFICATIONS ยง 23-27.3-128.2.2 RESPONSIBILITIES |
51 | ยง 23-27.3-128.2.3 REPORTING ยง 23-27.3-128.3 CONTRUCTION CONTRACTOR RESPONSIBILITIES ยง 23-27.3-128.4 TESTING REQUIRED ยง 23-27.3-128.5 BUILDING OFFICIAL’S RESPONSIBILITIES ยง 23-27.3-128.5.1 WAIVER OF PLAN EXAMINATION ยง 23-27.3-128.5.2 WAIVER OF DETAILED FIELD INSPECTION |
52 | ยง 23-27.3-128.5.3 INSPECTOIN WAIVER – UTILIZATION ยง 23-27.3-128.5.4 BUILDING PERMIT ISSUANCE OR REQUIREMENTS ยง 23-27.3-128.6 SPECIAL TECHNICAL SERVICES ยง 23-27.3-128.7 FEES AND COSTS ยง 23-27.3-129.0, 23-27.3-129.1 REPEALED ยง 23-27.3-129.2 REPEALED ยง 23-27.3-129.3 REPEALED ยง 23-27.3-200.0 SAVINGS CLAUSE ยง 23-27.3-300.0 PUBLICATION OF CODE ยง 23-27.3-400.0 SEVERABILITY |
53 | ยง 23-27.3-401.0 SALE OF PRESSURE VESSEL ยง 23-27.3-500.0 EFFECTIVE DATE OF CODE ยง 23-27.3-501.0, 23-27.3-502.0 REPEALED ยง 23-27.3-503.0, 23-27.3-504.0 [OBSOLETE] ยง 23-27.3-505.0 REPEALED ยง 23-27.3-506.0 [OBSOLETE] ยง 23-27.3-600.0 FRESH WATER WETLANDS ยง 23-27.3-700.0 REPEALED ยง 23-27.3-701.0 BABY CHANGING TABLES |
54 | CHAPTER 1 ADMINISTRATION PART 1โSCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
55 | PART 2โADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF PLUMBING INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 APPROVAL |
56 | SECTION 106 PERMITS |
57 | SECTION 107 INSPECTIONS AND TESTING |
58 | SECTION 108 VIOLATIONS SECTION 109 MEANS OF APPEAL SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
60 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
68 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS SECTION 304 RODENTPROOFING |
69 | SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS SECTION 306 TRENCHING, EXCAVATION AND BACKFILL |
70 | SECTION 307 STRUCTURAL SAFETY SECTION 308 PIPING SUPPORT TABLE 308.5 HANGER SPACING |
71 | SECTION 309 FLOOD HAZARD RESISTANCE SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 312 TESTS AND INSPECTIONS |
72 | SECTION 313 EQUIPMENT EFFICIENCIES |
73 | SECTION 314 CONDENSATE DISPOSAL [M] TABLE 314.2.2 CONDENSATE DRAIN SIZING |
74 | SECTION 315 PENETRATIONS SECTION 316 ALTERNATIVE ENGINEERED DESIGN |
76 | CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
77 | TABLE 403.1 โcontinued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
78 | TABLE 403.1 โcontinued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
80 | SECTION 404 ACCESSIBLE PLUMBING FACILITIES SECTION 405 INSTALLATION OF FIXTURES |
81 | SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 407 BATHTUBS SECTION 408 BIDETS SECTION 409 DISHWASHING MACHINES SECTION 410 DRINKING FOUNTAINS |
82 | SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 412 FLOOR AND TRENCH DRAINS SECTION 413 FOOD WASTE DISPOSER UNITS SECTION 414 GARBAGE CAN WASHERS SECTION 415 LAUNDRY TRAYS SECTION 416 LAVATORIES |
83 | SECTION 417 SHOWERS |
84 | SECTION 418 SINKS SECTION 419 URINALS SECTION 420 WATER CLOSETS SECTION 421 WHIRLPOOL BATHTUBS |
85 | SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT SECTION 423 SPECIALTY PLUMBING FIXTURES SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS |
86 | SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
87 | SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 427 FLOOR SINKS |
88 | CHAPTER 5 WATER HEATERS SECTION 501 GENERAL SECTION 502 INSTALLATION SECTION 503 CONNECTIONS |
89 | SECTION 504 SAFETY DEVICES SECTION 505 INSULATION |
90 | CHAPTER 6 WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL SECTION 602 WATER REQUIRED |
91 | SECTION 603 WATER SERVICE SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS |
92 | TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES |
93 | TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
94 | TABLE 605.3 WATER SERVICE PIPE TABLE 605.4 WATER DISTRIBUTION PIPE |
95 | TABLE 605.5 PIPE FITTINGS |
96 | TABLE 605.7 VALVES TABLE 605.8 MANUFACTURED PIPE NIPPLES |
99 | SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS |
100 | TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS SECTION 607 HOT WATER SUPPLY SYSTEM |
101 | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
102 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
103 | FIGURE 608.8.1 PICTOGRAPHโDO NOT DRINK TABLE 608.8.2.2 SIZE OF PIPE IDENTIFICATION |
104 | TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS |
106 | TABLE 608.17.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES |
107 | SECTION 609 HEALTH CARE PLUMBING SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM SECTION 611 DRINKING WATER TREATMENT UNITS |
108 | SECTION 612 SOLAR SYSTEMS SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES |
110 | CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL SECTION 702 MATERIALS TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
111 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.3 BUILDING SEWER PIPE |
112 | TABLE 702.4 PIPE FITTINGS SECTION 703 BUILDING SEWER SECTION 704 DRAINAGE PIPING INSTALLATION TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE |
113 | SECTION 705 JOINTS |
115 | TABLE 705.18 CAULKING FERRULE SPECIFICATIONS TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS |
116 | TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS |
117 | SECTION 709 FIXTURE UNITS |
118 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
119 | TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS SECTION 710 DRAINAGE SYSTEM SIZING TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa |
120 | SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE SECTION 712 SUMPS AND EJECTORS |
121 | TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION 713 HEALTH CARE PLUMBING |
122 | TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS (Number of Connections of Various Sizes Permitted to Various-sized Sterilizer Vent Stacks) TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS (Number of Connections of Various Sizes Permitted To Various-sized Vent Stacks) SECTION 714 COMPUTERIZED DRAINAGE DESIGN |
123 | SECTION 715 BACKWATER VALVES SECTION 716 VACUUM DRAINAGE SYSTEMS SECTION 717 REPLACEMENT OF UNDERGROUND SEWERS BY PIPE-BURSTING METHODS |
124 | CHAPTER 8 INDIRECT/SPECIAL WASTE SECTION 801 GENERAL SECTION 802 INDIRECT WASTES |
125 | SECTION 803 SPECIAL WASTES SECTION 804 MATERIALS, JOINTS AND CONNECTIONS |
126 | CHAPTER 9 VENTS SECTION 901 GENERAL SECTION 902 MATERIALS SECTION 903 VENT TERMINALS SECTION 904 OUTDOOR VENT EXTENSIONS |
127 | SECTION 905 VENT CONNECTIONS AND GRADES SECTION 906 VENT PIPE SIZING SECTION 907 VENTS FOR STACK OFFSETS |
128 | TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
129 | TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS SECTION 908 RELIEF VENTSโSTACKS OF MORE THAN 10 BRANCH INTERVALS SECTION 909 FIXTURE VENTS TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION 910 INDIVIDUAL VENT SECTION 911 COMMON VENT |
130 | TABLE 911.3 COMMON VENT SIZES SECTION 912 WET VENTING TABLE 912.3 WET VENT SIZE SECTION 913 WASTE STACK VENT TABLE 913.4 WASTE STACK VENT SIZE |
131 | SECTION 914 CIRCUIT VENTING SECTION 915 COMBINATION WASTE AND VENT SYSTEM TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE SECTION 916 ISLAND FIXTURE VENTING |
132 | SECTION 917 SINGLE STACK VENT SYSTEM TABLE 917.2 SINGLE STACK SIZE |
133 | SECTION 918 AIR ADMITTANCE VALVES SECTION 919 ENGINEERED VENT SYSTEMS EQUATION 9-1 |
134 | TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES SECTION 920 COMPUTERIZED VENT DESIGN |
136 | CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS |
137 | SECTION 1003 INTERCEPTORS AND SEPARATORS TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORSa |
138 | SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS |
140 | CHAPTER 11 STORM DRAINAGE SECTION 1101 GENERAL SECTION 1102 MATERIALS TABLE 1102.4 BUILDING STORM SEWER PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE |
141 | TABLE 1102.7 PIPE FITTING SECTION 1103 TRAPS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS |
142 | FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
143 | FIGURE 1106.1โcontinued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES |
144 | FIGURE 1106.1โcontinued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES |
145 | FIGURE 1106.1โcontinued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA |
146 | FIGURE 1106.1โcontinued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII |
147 | TABLE 1106.2 STORM DRAIN PIPE SIZING TABLE 1106.3 VERTICAL LEADER SIZING SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS |
148 | TABLE 1106.6 HORIZONTAL GUTTER SIZING SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1111 SUBSOIL DRAINS |
149 | SECTION 1112 BUILDING SUBDRAINS SECTION 1113 SUMPS AND PUMPING SYSTEMS |
150 | CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES SECTION 1203 OXYGEN SYSTEMS |
152 | CHAPTER 13 NONPOTABLE WATER SYSTEMS SECTION 1301 GENERAL FIGURE 1301.3 PICTOGRAPHโDO NOT DRINK |
154 | SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS |
155 | TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS |
156 | SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS |
157 | TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS |
158 | TABLE 1303.15.8 RAINWATER QUALITY SECTION 1304 RECLAIMED WATER SYSTEMS |
160 | CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS SECTION 1401 GENERAL SECTION 1402 SYSTEM DESIGN AND SIZING EQUATION 14-1 |
161 | TABLE 1402.3 LOCATION OF SUBSURFACE IRRIGATION SYSTEM SECTION 1403 INSTALLATION TABLE 1403.1.1 DESIGN LOADING RATE |
162 | TABLE 1403.2 DISTRIBUTION PIPE |
164 | CHAPTER 15 REFERENCED STANDARDS ANSI AHRI API ASME |
166 | ASPE ASSE |
167 | ASTM |
170 | AWS AWWA |
171 | CISPI CSA |
172 | IAPMO ICC |
173 | ISEA MSS NFPA NSF |
174 | PDI UL |
176 | APPENDIX A PLUMBING PERMIT FEE SCHEDULE |
178 | APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES |
180 | APPENDIX C STRUCTURAL SAFETY SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS |
182 | APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES |
184 | APPENDIX E SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL SECTION E102 INFORMATION REQUIRED SECTION E103 SELECTION OF PIPE SIZE |
188 | TABLE E.1 TABLE E.2 |
189 | FIGURE E103.3(1) EXAMPLE-SIZING |
190 | TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS |
191 | TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa |
192 | TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND |
193 | TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) |
194 | TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet) |
195 | FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING) |
196 | FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING) |
197 | FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING) |
198 | FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa |
199 | FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa |
200 | FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa |
201 | SECTION E201 SELECTION OF PIPE SIZE SECTION E202 DETERMINATION OF PIPE VOLUMES |
202 | TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
203 | TABLE E201.1โcontinued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
204 | TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING |
206 | INDEX |
216 | ICC EVALUATION SERVICE |
217 | ICC LEARNING CENTER |
218 | ICC ASSESSMENT CENTER |
219 | ICC MEMBERSHIP |