RI State 2 N/A
$53.30
Rhode Island State Building Code SBC-2 Rhode Island One and Two Family Dwelling Code Effective July 1, 2010
Published By | Publication Date | Number of Pages |
RI | N/A | 67 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | RHODE ISLAND STATE BUILDING CODE SBC-2 Rhode Island One and Two Family Dwelling Code Effective July 1, 2010 Replaces SBC-2 Dated January 1, 2007 www.ribcc.ri.gov |
4 | STATE BUILDING CODE REGULATIONS |
5 | Chapter 1 R101.1 Title. R101.2 Scope. R101.3 Intent. R102.5 Appendices R102.7 Existing structures. |
6 | R105.2 Work exempt from permit. |
7 | R105.3.1.1 Substantially improved or substantially damaged existing buildings or structures. Section R107 Fabric Structures R107.1 Fabric Structures: |
8 | R110.2 Change of Use. R115 Other R115.1 Other Administrative issues. |
9 | Chapter 2 |
12 | Chapter 3 R301.2 Climatic and geographic designs criteria. |
13 | R301.2.1 Wind limitations. R301.2.1.1 Design criteria. |
14 | 301.2.1.2 Protection of openings. R303.6 Stairway illumination. |
15 | R305.1 Minimum Height. R-307.3 Privacy required. |
16 | R309.1 Floor Surface: |
17 | R310.1 Emergency escape and rescue required. R310.1.1 Minimum opening area. R310.6 Basement or Cellar Windows: |
18 | R311.3 Landings at doors. R311.6 Hallways. R311.7.4.1 Riser height. R311.7.4.2 Tread depth. |
19 | 311.7.4.3 Profile. R311.7.9.3 Attic and other Pull-Down Types of Stairs R311.8.1 Maximum Slope R312.5 Seat or Bench Elements. R 313.1 General. R 314 Provisions for Fire Detection Systems |
20 | R317.1.3 Geographical areas. R321.1 Elevators. R321.2 Platform Lifts. R322.3.6.1 Flood Hazard Certificates |
21 | R322.4 Variances and appeals. (A) Board of Appeals (B) Conditions of Acceptance: |
23 | Chapter 4 R401.3 Drainage. |
25 | R403.1.4.1 Frost Protection. R403.1.6 General Foundation Anchorage. R403.1.6.1 Braced Panel Anchorage. |
26 | R403.3 Frost protected shallow foundations. R403.3.2 Protection of vertical and horizontal insulation. |
27 | Chapter 6 R602.10 Wall bracing. |
28 | Chapter 7 R 703.13 Re-siding Exterior Walls. |
29 | Chapter 8 Exception: R802.11.2 Rafters: |
30 | Chapter 9 R905.2.6 Attachment. R905.2.8.2 #3 |
31 | Chapter 10 R-1007.0 Room Heaters (Wood/Coal/Pellet Stoves) 1007.1 General: 1007.2 Multiple fuel-flue installations 1007.3 Used or antique stoves and room heaters: |
32 | Chapter 11 N1101.2 Compliance Methods |
36 | Chapter 14 M 1401.3 Sizing. |
37 | Chapter 15 M 1502.4.5 Length identification. |
38 | Chapter 16 Exceptions |
39 | Chapter 18 Exception: |
40 | Chapter 22 Exception: M2201.2 Above ground tanks. M2203.8 Emergency Disconnect Switch. |
41 | Chapter 24 G2411.1.1 (310.1.1) CSST Corrugated stainless steel tubing G2415.1 (401.1) Prohibited locations. G2415.4 (404.4) Piping through foundation wall. Exception: |
42 | G2439.5.6 Length identification. |
43 | Chapter 25 P2501.1 Scope. P2503.5.2 Finished Plumbing. |
44 | Chapter 26 Exception: Exception: P2603.6.1 Sewer Depth. |
45 | Chapter 29 P2903.3 Minimum Pressure. |
46 | Chapter 30 P3008.1 Mandatory installation of check valves. |
47 | Chapter 32 Traps P3201.2 Trap seals and trap seal protection. |
48 | Chapter 34 |
49 | Appendices APPENDIX R – RESIDENTIAL SPRINKLERS SECTION R-P2904 DWELLING UNIT FIRE SPRINKLER SYSTEMS R-P2904.1 General. R-P2904.1.1 Required sprinkler locations. R-P2904.2 Sprinklers. R-P2904.2.1 Temperature rating and separation from heat sources. R-P2904.2.2 Intermediate temperature sprinklers. |
50 | R-P2904.2.3 Freezing areas. R-P2904.2.4 Sprinkler coverage. R-P2904.2.4.1 Coverage area limit. R-P2904.2.4.2 Obstructions to coverage. R-P2904.2.4.2.1 Additional requirements for pendent sprinklers. |
51 | R-P2904.2.4.2.2 Additional requirements for sidewall sprinklers. R-P2904.2.5 Sprinkler installation on systems assembled with solvent cement. R-P2904.2.6 Sprinkler modifications prohibited. R-P2904.3 Sprinkler piping system. R-P2904.3.1 Nonmetallic pipe and tubing. R-P2904.3.1.1 Nonmetallic pipe protection. Exceptions: R-P2904.3.2 Shutoff valves prohibited. R-P2904.3.3 Single dwelling limit. R-P2904.3.4 Drain. |
52 | R-P2904.4 Determining system design flow. R-P2904.4.1 Determining required flow rate for each sprinkler. R-P2904.4.2 System design flow rate. R-P2904.5Water supply. R-P2904.5.1Water supply from individual sources. R-P2904.5.2 Required capacity. |
53 | R-P2904.6 Pipe sizing. R-P2904.6.1Method of sizing pipe. R-P2904.6.2 Prescriptive pipe sizing method. R-P2904.6.2.1 Available pressure equation. R-P2904.6.2.2 Calculation procedure. |
54 | R-P2904.7 Instructions and signs. |
55 | R-P2904.8 Inspections. R-P2904.8.1 Pre-concealment inspection. R-P2904.8.2 Final inspection. |
64 | Appendix AA AA 100 HIGH WIND PRESCRIPTIVE DESIGN AA 101.1 General. AA 101.2 Conditions of use. AA 202 Roofs AA 202.1 Scope. AA 202.2 Roof Sheathing. AA 202.3 Roof nailing. Exception: AA 202.4 Ridge Straps. |
65 | Exceptions: AA 202.5 Rake and eave overhangs. AA 202.6 Roof assembly to wall assembly. Exception: AA 203 Walls AA 203.1 Wall sheathing. |
66 | AA 203.2.1 Shear wall hold-downs. Exceptions AA 203.3 Foundation anchor bolts. Alternate Exception. |
67 | AA 203.4 Wall Framing. AA203.4.1. Wind Zone AA203.4.2 Garage doors. AA204 Deviations. AA204.1 Deviations. |