Shopping Cart

No products in the cart.

TAPPI TIP 0402-18:2015

$14.95

Ultrasonic Testing (Ut) for Tube Thickness in Black Liquor Recovery Boilers: Part I – Guidelines for Accurate Tube Thickness Testing; Part II – Default Layouts for Tube Thickness Surveys in Various Boiler Zones

Published By Publication Date Number of Pages
TAPPI 2015-04-10 19
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This TIP is a review of general considerations related to UT thickness testing of black liquor recovery boiler tubes:

  • Part I of this TIP provides guidelines and procedures for acquiring accurate ultrasonic thickness readings on boiler tubes, where the tube material and condition are conductive to such non-destructive testing.
  • Part II describes how tube thickness surveys are commonly laid out for different zones of a typical recovery boiler. It also stresses that a customized survey is essential for each boiler.