Shopping Cart

No products in the cart.

TX Houston 2012 ibc amendments:2015 Edition

$54.60

Houston Amendments to the 2012 International Building Code – Effective Date: 02/01/2016

Published By Publication Date Number of Pages
TX 2015 160
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
1 Houston Amendments to
the 2012 International
Building Code
Adopted by Ord. No. 2015-1108
Passed 11/10/2015
Effective 02/01/2016
2 CHAPTER 1
38 CHAPTER 2
SECTION 202*
DEFINITIONS
UCITY CODE. The Code of Ordinances, Houston, Texas.
UCITY FEE SCHEDULE. The schedule of fees charged by the city for various permits, licenses, authorizations and services, which schedule is maintained on the city’s website.
UCONSTRUCTION CODE. The City of Houston Construction Code, consisting of the Building Code, Electrical Code, Mechanical Code, Plumbing Code, Residential Code, Commercial Energy Conservation Code, and Residential Energy Conservation Code.
39 UFIRE CODE. The City of Houston Fire Code, as adopted by this jurisdiction. See Section 101.4.5.
40 USIGN CODE. The Houston Sign Code, Chapter 46 of this code, which is published as a separate document.
41 SWHEELCHAIR SPACE. A space for a single wheelchair and its occupant.
42 CHAPTER 3
43 UNOTES:
47 CHAPTER 4
48 USECTION 426
UREUSE OF BUILDING MATERIALS
U426.1 Reuse of building materials. Reuse of building materials shall be allowed in accordance with Appendix R.
49 CHAPTER 5
50 USECTION 512
UException: Buildings located in annexed subdivisions where the following conditions exist:
UNOTE: When a greater elevation is required by Chapter 19 of the City Code, then Chapter 19 shall govern.
53 CHAPTER 6
55 CHAPTER 7
57 CHAPTER 9
66 CHAPTER 10
70 CHAPTER 11
72 CHAPTER 12
74 CHAPTER 14
76 CHAPTER 15
80 CHAPTER 23
82 CHAPTER 29
113 UCHAPTER 46
UThe Houston Sign Code, which is published as a separate document, constitutes Chapter 46 of this code.
115 UCHAPTER 62
USECTION 6201
UCOMMERCIAL PIER. One or more piers, any part of which is used for any of the following:
UJETTY. A permanent structure built into a body of water to direct the current or protect a harbor.
116 UPRIVATE PIER. A pier other than a commercial pier.
USECTION 6202
117 U6202.2 Private piers. In lieu of the design requirements in Section 6202.1.6, private piers may be constructed as follows:
USECTION 6203
118 USECTION 6204
U6204.1 Bulkhead construction. Bulkheads shall be constructed of wood, steel, concrete or aluminum. All wood used in construction of bulkheads shall be pressure treated with an approved preservative.
120 USECTION 6205
122 UEXCAVATION AND GRADING
USECTION E101
USECTION E102
USECTION E103
UE103.2 Exempted work. A grading permit is not required for the following:
123 USECTION E104
USECTION E105
UAS-GRADED. The extent of surface conditions on completion of grading.
UBEDROCK. In-place solid rock.
UBENCH. A relatively level step excavated into earth material on which fill is to be placed.
UBORROW. Earth material acquired from an off-site location for use in grading on a site.
124 UCOMPACTION. The densification of a fill by mechanical means.
UEARTH MATERIAL. Any rock, natural soil or fill or any combination thereof.
UENGINEERING GEOLOGIST. A geologist experienced and knowledgeable in engineering geology.
UEROSION. The wearing away of the ground surface as a result of the movement of wind, water or ice.
UEXCAVATION. The mechanical removal of earth material.
UFILL. A deposit of earth material placed by artificial means.
UGEOTECHNICAL ENGINEER. See “soils engineer.”
UGRADE. The vertical location of the ground surface.
UExisting Grade. The grade prior to grading
UFinish Grade. The final grade of the site that conforms to the approved plan.
URough Grade. The stage at which the grade approximately conforms to the approved plan.
UGRADING. Any excavating or filling or combination thereof.
USOIL. Naturally occurring superficial deposits overlying bedrock.
125 USECTION E106
USpecifications shall contain information covering construction and material requirements.
UThe plans shall include the following information:
126 UThe report of the investigation shall address the potential for liquefaction.
127 USECTION E107
USECTION E108
USECTION E109
USECTION E110
128 UE110.4 Compaction. All fills shall be compacted to a minimum of 90 percent of maximum density.
USECTION E111
129 USECTION E112
UDRAINAGE AND TERRACING
130 USECTION E113
UEROSION CONTROL
USECTION E114
131 USECTION E115
133 UFigure E111.1 – Setback Dimensions
135 UAPPENDIX K
USECTION K101
UGENERAL
USECTION K102
USECTION K103
136 USECTION K104
137 USECTION K105
UELEVATED FOUNDATION
139 UAPPENDIX L
USECTION L101
UHazard categories (from highest to lowest group):
140 USECTION L102
141 UException: Fire escapes as provided for in this section.
UExterior stairs shall be of noncombustible construction.
UL102.4 Fire escapes.
UL102.4.2 General requirements. Fire escapes shall comply with the following:
142 UL102.5 Exit and fire escape signs. Exit signs shall be provided as required by this code.
143 UAll doors or windows providing access to a fire escape shall be provided with fire escape signs.
UL102.6 Exit illumination. Exits shall be illuminated as required by Section 1006.
USECTION L103
UExceptions:
USECTION L104
144 USECTION L105
USECTION L106
USECTION L107
145 USECTION L108
UException: Systems that are connected to a central, proprietary, or remote station service.
USECTION L109
UThe application shall be accompanied by documents (examples of which include affidavits, photographs, receipts, loan applications, and contracts with third parties) demonstrating that the owner has made substantial and timely attempts to bring the b…
UThe owner of the building shall swear to the accuracy of all facts stated in the application.
USECTION L110
146 UAn application shall be sworn to by the owner of the building.
148 UAPPENDIX M
UMINIMUM PROVISIONS FOR CHANGE OF OCCUPANCY
155 UN601.1 General. Roof/ceiling assemblies shall be constructed in accordance with the requirements of N601.2 or N601.3.
UException: Roof/ceiling assemblies or materials that have been tested or listed with a minimum STC rating of 40.
UN601.2 Ceilings with unconditioned attic space above. Ceilings with unconditioned attic space above shall be insulated with a minimum of ½ inch gypsum drywall on the interior ceiling side covered with a minimum of 12 inches of blown in fiberglass ins…
UN601.3 Ceilings without attic space above. Ceilings without attic space above shall be insulated with a minimum of 5/8 inch gypsum drywall on the interior side filled with a minimum of 9 inches of fiberglass batt insulation with a 1 inch air space be…
TX Houston 2012 ibc amendments