Shopping Cart

No products in the cart.

VA ConstructionCode 2018 1stptg

$68.33

Virginia Construction Code

Published By Publication Date Number of Pages
VA 2018 761
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2018 International Building Code®.

PDF Catalog

PDF Pages PDF Title
1 2018 VIRGINIA CONSTRUCTION CODE
2018 VIRGINIA CONSTRUCTION CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
14 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
15 SECTION 102 PURPOSE AND SCOPE
16 SECTION 103 APPLICATION OF CODE
18 SECTION 104 ENFORCEMENT, GENERALLY
SECTION 105 LOCAL BUILDING DEPARTMENT
19 SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
20 SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMIT
22 SECTION 109 CONSTRUCTION DOCUMENTS
23 SECTION 110 PERMITS
24 SECTION 111 REGISTERED DESIGN PROFESSIONAL SERVICES
SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT
27 SECTION 113 INSPECTIONS
29 SECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS
SECTION 116 CERTIFICATES OF OCCUPANCY
30 SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION
31 SECTION 118 UNSAFE BUILDINGS OR STRUCTURES
32 SECTION 119 APPEALS
34 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
66 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
67 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
68 SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
69 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
70 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
71 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
73 SECTION 308 INSTITUTIONAL GROUP I
75 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
76 SECTION 311 STORAGE GROUP S
SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
77 SECTION 313 STATE REGULATED CARE FACILITIES (SRCF)
78 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
81 EQUATION 4-1
82 SECTION 403 HIGH-RISE BUILDINGS
83 TABLE 403.2.4 MINIMUM BOND STRENGTH
85 SECTION 404 ATRIUMS
86 SECTION 405 UNDERGROUND BUILDINGS
87 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
89 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
91 SECTION 407 GROUP I-2
94 SECTION 408 GROUP I-3
96 SECTION 409 MOTION PICTURE PROJECTION ROOMS
97 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
99 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
100 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
102 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
103 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
104 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
105 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
106 [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
107 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
109 [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED
111 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
116 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
117 SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE/WORK UNITS
118 SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
119 SECTION 421 HYDROGEN FUEL GAS ROOMS
SECTION 422 AMBULATORY CARE FACIILITIES
120 SECTION 423 STORM SHELTERS
121 SECTION 424 CHILDREN’S PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
122 SECTION 427 MEDICAL GAS SYSTEMS
SECTION 428 HIGHER EDUCATION LABORATORIES
123 [F] TABLE 428.3 DESIGN AND NUMBER OF LABORATORY SUITES PER FLOOR
124 SECTION 429 MANUFACTURED HOMES AND INDUSTRIALIZED BUILDINGS
125 SECTION 430 ABOVEGROUND LIQUID FERTILIZER TANKS
SECTION 431 SHORT-TERM HOLDING AREAS
126 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
127 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
129 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
130 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
SECTION 506 BUILDING AREA
131 EQUATION 5-1
EQUATION 5-2
EQUATION 5-3
132 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
133 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
134 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
EQUATION 5-4
EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
136 SECTION 508 MIXED USE AND OCCUPANCY
137 SECTION 509 INCIDENTAL USES
138 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 510 SPECIAL PROVISIONS
139 [F] TABLE 509 INCIDENTAL USES
142 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
143 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
146 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
147 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
149 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
150 EQUATION 7-1
EQUATION 7-2
151 FIGURE 705.7 EQUIVALENT OPENING FACTOR
152 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
153 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
155 SECTION 707 FIRE BARRIERS
156 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
157 SECTION 708 FIRE PARTITIONS
158 SECTION 709 SMOKE BARRIERS
159 SECTION 710 SMOKE PARTITIONS
SECTION 711 FLOOR AND ROOF ASSEMBLIES
160 SECTION 712 VERTICAL OPENINGS
161 SECTION 713 SHAFT ENCLOSURES
163 SECTION 714 PENETRATIONS
165 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
166 SECTION 716 OPENING PROTECTIVES
167 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
168 TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
169 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
173 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
TABLE 717.3.2.1 FIRE DAMPER RATING
177 SECTION 718 CONCEALED SPACES
179 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
180 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
181 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
182 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
183 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
184 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
185 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
186 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
187 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
188 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
189 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
190 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
191 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
192 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
193 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
194 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
195 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
196 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
197 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
198 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
199 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
200 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
201 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
202 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
203 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
204 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
205 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
206 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
207 TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
208 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
209 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
210 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc(APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
211 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
EQUATION 7-6
212 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
EQUATION 7-7
213 TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
214 EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
215 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
EQUATION 7-13
216 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
217 EQUATION 7-14
EQUATION 7-15
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
218 EQUATION 7-16
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
219 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
221 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
222 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
223 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
224 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
225 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
226 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
227 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
228 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
229 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
230 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
231 TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
232 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
234 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
235 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
236 SECTION 806 DECORATIVE MATERIALS AND TRIM
237 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
238 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
239 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
240 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
243 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
245 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
248 SECTION 905 STANDPIPE SYSTEMS
250 SECTION 906 PORTABLE FIRE EXTINGUISHERS
251 [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
252 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
261 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
262 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
264 EQUATION 9-1
265 EQUATION 9-2
270 SECTION 910 SMOKE AND HEAT REMOVAL
271 EQUATION 9-3
EQUATION 9-4
272 SECTION 911 FIRE COMMAND CENTER
273 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
274 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
275 SECTION 916 GAS DETECTION SYSTEMS
SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 IN-BUILDING EMERGENCY COMMUNICATIONS COVERAGE
278 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
279 SECTION 1004 OCCUPANT LOAD
280 TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SECTION 1005 MEANS OF EGRESS SIZING
282 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
283 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
284 TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1006.3.3(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
285 SECTION 1008 MEANS OF EGRESS ILLUMINATION
286 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
289 SECTION 1010 DOORS, GATES AND TURNSTILES
290 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
297 SECTION 1011 STAIRWAYS
301 SECTION 1012 RAMPS
302 SECTION 1013 EXIT SIGNS
303 SECTION 1014 HANDRAILS
304 SECTION 1015 GUARDS
305 SECTION 1016 EXIT ACCESS
306 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
307 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
308 SECTION 1020 CORRIDORS
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
309 SECTION 1021 EGRESS BALCONIES
310 SECTION 1022 EXITS
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
312 SECTION 1024 EXIT PASSAGEWAYS
313 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
314 SECTION 1026 HORIZONTAL EXITS
315 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
316 SECTION 1028 EXIT DISCHARGE
317 SECTION 1029 ASSEMBLY
TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
321 TABLE 1029.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
323 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
326 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 COMPLIANCE
SECTION 1103 SCOPING REQUIREMENTS
327 SECTION 1104 ACCESSIBLE ROUTE
328 SECTION 1105 ACCESSIBLE ENTRANCES
SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.1(1) ACCESSIBLE PARKING SPACES FOR GROUPS A, B, E, M, R-1, R-2, and Ia
329 TABLE 1106.1(2) ACCESSIBLE PARKING SPACES FOR GROUPS F, S, H, R-3, R-4, AND U
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
331 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
333 SECTION 1108 SPECIAL OCCUPANCIES
TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
334 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
335 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
SECTION 1109 OTHER FEATURES AND FACILITIES
338 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
339 SECTION 1110 RECREATIONAL FACILITIES
340 TABLE 1110.4.9.1 BOAT SLIPS
SECTION 1111 SIGNAGE
342 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
343 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
345 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
SECTION 1205 YARDS OR COURTS
SECTION 1206 SOUND TRANSMISSION
346 TABLE 1206.4 AIRPORT NOISE ATTENUATION STANDARDS
SECTION 1207 INTERIOR SPACE DIMENSIONS
347 SECTION 1208 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
350 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
351 EQUATION 4-5
TABLE C402.4.3 SHGC ADJUSTMENT MULTIPLIERS
352 TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE R402.1.4 EQUIVALENT U-FACTORSa
TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
356 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
SECTION 1403 MATERIALS
357 SECTION 1404 INSTALLATION OF WALL COVERINGS
358 TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
TABLE 1404.3.2 CLASS III VAPOR RETARDERS
362 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
363 TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
365 TABLE 1406.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
366 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
367 SECTION 1409 PLASTIC COMPOSITE DECKING
368 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
SECTION 1504 PERFORMANCE REQUIREMENTS
369 TABLE 1504.1.1 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161 OR D7158
370 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
371 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.1.1(1) UNDERLAYMENT TYPES
372 TABLE 1507.1.1(2) INDERLAYMENT APPLICATION
373 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
374 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
375 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
376 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
377 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
378 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
379 TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
380 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
381 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
382 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
383 SECTION 1510 ROOFTOP STRUCTURES
385 SECTION 1511 ROOFING AND ROOFING REPAIR
SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES
386 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
387 SECTION 1604 GENERAL DESIGN REQUIREMENTS
388 TABLE 1604.3 DEFLECTION LIMITS
389 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
390 SECTION 1605 LOAD COMBINATIONS
391 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
392 EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
393 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
394 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
396 EQUATION 16-23
TABLE 1607.11.1 LIVE LOAD ELEMENT FACTOR, KLL
EQUATION 16-24
397 EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
399 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
400 TABLE 1609.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
401 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
402 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
403 EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONS
404 FIGURE 1609.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
405 FIGURE 1609.3(2 )BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
406 FIGURE 1609.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
407 FIGURE 1609.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
408 FIGURE 1609.3(5) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII
409 FIGURE 1609.3(5)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII
410 FIGURE 1609.3(6) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
411 FIGURE 1609.3(6)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
412 FIGURE 1609.3(7) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
413 FIGURE 1609.3(7)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
414 FIGURE 1609.3(8) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
415 FIGURE 1609.3(8)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
416 EQUATION 16-34
SECTION 1610 SOIL LATERAL LOADS
SECTION 1611 RAIN LOADS
EQUATION 16-35
417 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1612 FLOOD LOADS
418 [P] FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
419 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
420 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
421 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
422 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HA
423 SECTION 1613 EARTHQUAKE LOADS
424 EQUATION 16-36
EQUATION 16-37
EQUATION 16-38
EQUATION 16-39
TABLE 1613.2.3(1) VALUES OF SITE COEFFICIENT Fa a
425 TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT FV a
TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
426 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
SECTION 1616 STRUCTURAL INTEGRITY
427 EQUATION 16-40
EQUATION 16-41
429 FIGURE 1613.2.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)(continued)
430 FIGURE 1613.2.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
431 FIGURE 1613.2.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
432 FIGURE 1613.2.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
433 FIGURE 1613.2.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
434 FIGURE 1613.2.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
435 FIGURE 1613.2.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
436 FIGURE 1613.2.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
437 FIGURE 1613.2.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
438 FIGURE 1613.2.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
439 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
440 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
441 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
443 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
444 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
445 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
446 TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
451 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
452 SECTION 1709 PRECONSTRUCTION LOAD TESTS
454 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
456 SECTION 1804 EXCAVATION, GRADING AND FILL
457 SECTION 1805 DAMPPROOFING AND WATERPROOFING
458 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
459 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
461 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb,
462 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c
463 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c
EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
464 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
SECTION 1808 FOUNDATIONS
465 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHESa, b, c
466 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
467 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′C OF CONCRETE OR GROUT
468 TABLE 1808.8.2 MINIMUM CONCRETE COVER
SECTION 1809 SHALLOW FOUNDATIONS
469 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
470 SECTION 1810 DEEP FOUNDATIONS
472 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
474 EQUATION 18-4
476 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
477 EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
484 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
485 SECTION 1905 MODIFICATIONS TO ACI 318
487 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
SECTION 1908 SHOTCRETE
490 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
492 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
493 SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
494 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
EQUATION 21-2
495 TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
496 SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
498 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
499 SECTION 2113 MASONRY CHIMNEYS
501 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
502 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
503 SECTION 2114 DRY-STACK MASONRY
TABLE 2114.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
504 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
505 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
506 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
508 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
512 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
513 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
514 TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
515 TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa
TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)
516 TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS
TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICK
518 TABLE 2304.10.1 FASTENING SCHEDULE
519 TABLE 2304.10.1—continued FASTENING SCHEDULE
520 TABLE 2304.10.1—continued FASTENING SCHEDULE
521 TABLE 2304.10.1—continued FASTENING SCHEDULE
522 TABLE 2304.10.1—continued FASTENING SCHEDULE
523 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
525 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP
EQUATION 23-2
526 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
527 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
528 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
529 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
530 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
531 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
532 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
533 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
535 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS
536 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS
537 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS
538 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
539 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
540 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
541 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
542 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
543 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
545 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
546 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
547 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
548 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
549 TABLE 2308.6.3(1) BRACING METHODS
550 TABLE 2308.6.3(1)—continued BRACING METHODS
TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
551 TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
TABLE 2308.6.3(5) HARDBOARD SIDING
552 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
554 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
556 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
557 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
558 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)
559 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
560 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
561 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
562 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
563 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
564 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES
565 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
566 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES
567 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
568 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES
569 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
570 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES
571 TABLE 2308.7.2(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
572 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES
573 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
574 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES
575 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
576 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSg
577 TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
578 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
580 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
581 EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
582 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
583 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
584 TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
585 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
586 SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
588 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
SECTION 2507 LATHING AND PLASTERING
589 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
590 TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2509 SHOWERS AND WATER CLOSETS
591 TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
592 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
593 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2514 REINFORCED GYPSUM CONCRETE
594 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
597 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
599 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
600 TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
SECTION 2605 PLASTIC VENEER
601 TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
602 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
603 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
604 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
605 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
606 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
608 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
612 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
613 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
616 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
617 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
618 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
619 TABLE 403.1.4 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES FOR MARINAS
622 TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS
623 TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS
624 TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING
FIGURE 1301.4 PICTOGRAPH—DO NOT DRINK
625 TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS
629 TABLE 1302.5.1 LOCATION OF NONPOTABLE GRAYWATER REUSE STORAGE TANKS
630 TABLE 1303.8.1 LOCATION OF RAINWATER STORAGE TANKS
631 SECTION 2902 MINIMUM PLUMBING FACILITIES
632 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.3 ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
SECTION 3002 HOISTWAY ENCLOSURES
633 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
634 SECTION 3005 MACHINE ROOMS
SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING- PROTECTION
SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
635 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
636 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
640 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
641 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
643 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOLS, SWIMMING POOL ENCLOSURES, AND AQUATIC RECREATIONAL FACILITIES
644 SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 GREENHOUSES
645 SECTION 3113 RELOCATABLE BUILDINGS
646 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
648 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
649 TABLE 3306.1 PROTECTION OF PEDESTRIANS
650 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
651 SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3314 FIRE WATCH DURING CONSTRUCTON
652 CHAPTER 34 RESERVED
654 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
AISC
AISI
655 ALI
AMCA
ANSI
656 APA
657 API
ASABE
ASCE/SEI
658 ASME
ASSE
ASTM
669 AWC
AWCI
670 AWPA
AWS
BHMA
CEN
CPA
671 CPSC
CSA
CSSB
DASMA
672 DOC
DOL
DOTn
FEMA
FM
673 GA
HPVA
ICC
674 ISO
675 MHI
NAAMM
NCMA
NFPA
678 PCI
PTI
RMI
SBCA
SDI
SJI
679 SPRI
SRCC
TFI
TIA
TMS
680 TPI
UL
682 ULC
USC
WCLIB
WDMA
WRI
684 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
SECTION E105 OTHER FEATURES AND FACILITIES
685 TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
686 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
687 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
688 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
690 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
692 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
693 SECTION G104 PERMITS
694 SECTION G105 VARIANCES
695 SECTION G201 DEFINITIONS
SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
696 SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
697 SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
SECTION G1101 REFERENCED STANDARDS
698 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
699 SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
700 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
701 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
702 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
704 APPENDIX N REPLICABLE BUILDINGS
SECTION N101 ADMINISTRATION
SECTION N102 DEFINITIONS
SECTION N103 REPLICABLE DESIGN REQUIREMENTS
SECTION N104 REPLICABLE DESIGN SUBMITTAL REQUIREMENTS
705 SECTION N105 REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N106 SITE-SPECIFIC APPLICATION OF APPROVED REPLICABLE DESIGN
SECTION N107 SITE-SPECIFIC REVIEW AND APPROVAL OF REPLICABLE DESIGN
706 SUPPLEMENTAL MASS TIMBER INFORMATION2021 I-CODE PROVISIONS FOR MASS TIMBER
CHAPTER 2 DEFINITIONS
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
707 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANEa
708 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
709 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
710 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
711 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
712 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
CHAPTER 6 TYPES OF CONSTRUCTION
713 EQUATION 6-1
714 TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
715 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
716 TABLE 705.5 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
TABLE 722.7.1(1) PROTECTION REQUIRED FROM NONCOMBUSTIBLE COVERING MATERIAL
TABLE 722.7.1(2) PROTECTION PROVIDED BY NONCOMBUSTIBLE COVERING MATERIAL
717 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
TABLE 1705.5.3 REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
CHAPTER 23 WOOD
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
718 CHAPTER 35 REFERENCED STANDARDS
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
720 INDEX
758 HELPFUL TOOLS FOR YOUR BUILDING CODE
759 GENERAL CODE, LLC
760 TELEWORK WITH ICC DIGITAL CODES PREMIUM
761 ICC EVALUATION SERVICE
VA ConstructionCode 2018 1stptg
$68.33