Shopping Cart

No products in the cart.

VA FuelGasCode 2018 1stptg

$54.71

Virginia Fuel Gas Code

Published By Publication Date Number of Pages
VA 2018
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

his is a fully integrated code based on the 2018 International Fuel Gas Code®.

PDF Catalog

PDF Pages PDF Title
1 2018 VIRGINIA FUEL GAS CODE
2 2018 VIRGINIA FUEL GAS CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
8 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
9 SECTION 102 PURPOSE AND SCOPE
10 SECTION 103 APPLICATION OF CODE
12 SECTION 104 ENFORCEMENT, GENERALLY
SECTION 105 LOCAL BUILDING DEPARTMENT
13 SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
14 SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMIT
16 SECTION 109 CONSTRUCTION DOCUMENTS
17 SECTION 110 PERMITS
18 SECTION 111 REGISTERED DESIGN PROFESSIONAL SERVICES
19 SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT
21 SECTION 113 INSPECTIONS
23 SECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS
SECTION 116 CERTIFICATES OF OCCUPANCY
24 SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION
25 SECTION 118 UNSAFE BUILDINGS OR STRUCTURES
26 SECTION 119 APPEALS
28 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
36 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
37 SECTION 302 (IFGC) STRUCTURAL SAFETY
38 SECTION 303 (IFGC) APPLIANCE LOCATION
SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
39 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING
EQUATION 3-1
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
40 EQUATION 3-2
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS
42 SECTION 305 (IFGC) INSTALLATION
SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
44 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
45 TABLE 308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
46 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
47 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
48 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
49 EQUATION 4-1
EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
50 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
51 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
52 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
53 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
54 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
55 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
56 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
57 TABLE 402.4(8) SEMIRIGID COPPER TUBING
58 TABLE 402.4(9) SEMIRIGID COPPER TUBING
59 TABLE 402.4(10) SEMIRIGID COPPER TUBING
60 TABLE 402.4(11) SEMIRIGID COPPER TUBING
61 TABLE 402.4(12) SEMIRIGID COPPER TUBING
62 TABLE 402.4(13) SEMIRIGID COPPER TUBING
63 TABLE 402.4(14) SEMIRIGID COPPER TUBING
64 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
65 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
66 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
67 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
68 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
69 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
70 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
71 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
72 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
73 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
74 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
75 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
76 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
77 TABLE 402.4(29) SEMIRIGID COPPER TUBING
78 TABLE 402.4(30) SEMIRIGID COPPER TUBING
79 TABLE 402.4(31) SEMIRIGID COPPER TUBING
80 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
81 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
82 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
83 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
84 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
85 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
86 SECTION 403 (IFGS) PIPING MATERIALS
87 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
88 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
90 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
91 SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
92 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
93 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
94 SECTION 409 (IFGC) SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
SECTION 410 (IFGC) FLOW CONTROLS
95 SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
96 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
98 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
99 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
100 SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
102 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
103 SECTION 502 (IFGC) VENTS
104 SECTION 503 (IFGS) VENTING OF APPLIANCES
105 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
107 FIGURE 503.6.5 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE NOT LESS THAN 8 FEET FROM A VERTICAL WALL
110 TABLE 503.8 THROUGH-THE-WALL, DIRECT-VENT TERMINATION CLEARANCES
TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
111 TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
112 TABLE 503.10.5 CLEARANCES FOR CONNECTORSa
113 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
115 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
117 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
118 SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
119 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
120 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
121 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
122 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
123 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
124 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
125 TABLE 504.2(3) MASONRY CHIMNEY
126 TABLE 504.2(3)—continued MASONRY CHIMNEY
127 TABLE 504.2(4) MASONRY CHIMNEY
128 TABLE 504.2(4)—continued MASONRY CHIMNEY
129 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
130 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
131 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
132 TABLE 504.3(1)—continued TYPE B DOUBLE-WALL VENT
133 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
134 TABLE 504.3(3) MASONRY CHIMNEY
135 TABLE 504.3(4) MASONRY CHIMNEY
136 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
137 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY—continued
138 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
140 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
141 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
142 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
143 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
144 SECTION 615 (IFGC) SAUNA HEATERS
145 SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
146 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
147 SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
148 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
149 SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
150 SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
152 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
153 SECTION 704 (IFGC) PIPING, USE AND HANDLING
154 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
155 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
156 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
157 ASME
158 ASTM
159 CGA
CSA
DOTn
ICC
160 MSS
NFPA
UL
162 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
163 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
164 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
165 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
167 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
168 TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
169 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
170 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
172 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
173 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
174 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
175 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
176 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
177 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
179 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
180 FIGURE B-19
182 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
184 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
185 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
186 D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
187 D.6 APPLIANCE-SPECIFIC INSPECTIONS
188 TABLE D.6 CO THRESHOLDS
190 INDEX
194 ICC LEARNING CENTER
195 PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™)
196 ICC EVALUATION SERVICE
197 TELEWORK WITH ICC DIGITAL CODES PREMIUM
VA FuelGasCode 2018 1stptg
$54.71