Shopping Cart

No products in the cart.

VA MechanicalCode 2015 1stEdition

$51.46

Virginia Mechanical Code

Published By Publication Date Number of Pages
VA 2015 167
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2015 International Mechanical Code

PDF Catalog

PDF Pages PDF Title
1 2015 VIRGINIA MECHANICAL CODE
2 2015 VIRGINIA MECHANICAL CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
10 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 PURPOSE AND SCOPE
SECTION 103 APPLICATION OF CODE
12 SECTION 104 ENFORCEMENT, GENERALLY
SECTION 105 LOCAL BUILDING DEPARTMENT
13 SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
14 SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMITS
16 SECTION 109 CONSTRUCTION DOCUMENTS
17 SECTION 110 PERMITS
18 SECTION 111 RDP SERVICES
SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT
21 SECTION 113 INSPECTIONS
22 SECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS
23 SECTION 116 CERTIFICATES OF OCCUPANCY
24 SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION
SECTION 118 UNSAFE BUILDINGS OR STRUCTURES
25 SECTION 119 APPEALS
28 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
40 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
41 SECTION 302 PROTECTION OF STRUCTURE
42 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
44 SECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
46 SECTION 307 CONDENSATE DISPOSAL
TABLE 307.2.2 CONDENSATE DRAIN SIZING
47 SECTION 308 CLEARANCE REDUCTION
48 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
SECTION 309 TEMPERATURE CONTROL
SECTION 310 EXPLOSION CONTROL
49 SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
50 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
SECTION 402 NATURAL VENTILATION
51 SECTION 403 MECHANICAL VENTILATION
52 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESSa,b,c,d
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
53 TABLE 403.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCYa,b
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9
54 TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3, AND R-4 OCCUPANCIES
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
55 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
56 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
57 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
58 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
60 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
61 SECTION 502 REQUIRED SYSTEMS
EQUATION 5-1
68 SECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST
69 TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
70 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
75 SECTION 507 COMMERCIAL KITCHEN HOODS
77 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
78 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
79 SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
81 TABLE 510.9 MINIMUM DUCT THICKNESS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
82 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
84 EQUATION 5-2
85 EQUATION 5-3
86 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
88 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
89 SECTION 602 PLENUMS
90 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
91 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
93 SECTION 604 INSULATION
SECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
94 SECTION 607 DUCT AND TRANSFER OPENINGS
95 [BF] TABLE 607.3.2.1 FIRE DAMPER RATING
100 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
102 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
103 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
104 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
105 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCESa, b, c, d
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
106 SECTION 805 FACTORY-BUILT CHIMNEYS
107 SECTION 806 METAL CHIMNEYS
108 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
109 SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
110 SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
111 SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES
SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
112 SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 RADIANT HEATING SYSTEMS
SECTION 928 EVAPORATIVE COOLING EQUIPMENT
114 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS
115 TABLE 1004.3.1 BOILER TOP CLEARANCES
SECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
116 SECTION 1007 BOILER LOW-WATER CUTOFF
SECTION 1008 BOTTOM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
117 SECTION 1010 GAUGES
SECTION 1011 TESTS
118 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS
119 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
120 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
121 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
122 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
123 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
124 SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
125 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
EQUATION 11-1
126 EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
127 SECTION 1107 REFRIGERANT PIPING
128 SECTION 1108 FIELD TEST
[F] SECTION 1109 PERIODIC TESTING
130 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4—continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS
131 SECTION 1203 JOINTS AND CONNECTIONS
132 SECTION 1204 PIPE INSULATION
133 SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
134 SECTION 1209 EMBEDDED PIPING
SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
TABLE 1210.4 GROUND-SOURCE LOOP PIPE
135 TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
138 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS
139 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
SECTION 1306 OIL GAUGING
140 SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
142 CHAPTER 14 SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION
143 SECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 MATERIALS
144 CHAPTER 15 REFERENCED STANDARDS
ACCA
AHRI
AMCA
ANSI
145 ASHRAE
ASME
ASSE
ASSE
146 ASTM
148 AWS
AWWA
CSA
149 DOL
FS
ICC
150 IIAR
MSS
NAIMA
NBBI
NFPA
151 NSF
SMACNA
UL
154 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
155 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
156 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
158 INDEX
164 ICC ASSESSMENT CENTER
165 ICC’S DIGITAL LIBRARY
166 ICC EVALUATION SERVICE
167 TURN TO ICC FOR YOUR GO-TO CODE RESOURCES
VA MechanicalCode 2015 1stEdition
$51.46